| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹27.3 L+₹1.8 L (7.14%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹27.4 L+₹1.9 L (7.42%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L3 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
8 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (CENTRAL) KOLKATA
GE (CENTRAL) KOLKATA T-37 NAPIER ROAD HASTING KOLKATA 700022
8451/E8
2022_MES_513366_1
8451/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (CENTRAL) KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (CENTRAL) KOLKATA
₹52,000
Yes
1 Nov 2022
12 Mar 2022
9 Apr 2022
12 Mar 2022
8 Apr 2022
27 Mar 2022
12 Mar 2022 - 26 Mar 2022
60 days
Amount
Taking out of Existing unserviceable compressor sealed unit from window/split type Air conditioner of capacity 1.0/ 1.5/ 2.0 TR capacity and allied components complete all as specified and directed by Engr-in-Charge.
Repairing and fixing only reconditioned sealed compressor suitable for 2.0 TR (6000 Kcal/hr)/1.5 TR (4500 Kcal/hr window/split type Air conditioner including vacumminishing, initial charging of oil and complete all as directed by Engr-in-Charge. Make: As per existing.
Supply and Fixing of new sealed rotary type compressor suitable for 1/1.5/ 2.0TR (3000/4500/6000 Kcal/hr) window type/split type Air conditioner including vacumminishing, commissioning ,testing and initial charging of oil complete all as directed by Engr-in-Charge. Make : Highly, Voltas, Hitachi
Repairing and Fixing of bush bearing of blower fan motor for window/split type AC, including taking down old U/S one complete all as specified and directed .
S&F of capacitor 4 /6 MFD of blower fan motor for window/split type AC's including taking down old U/S one complete all as specified and directed by Engr-in-charge.
Taking out worn-out copper capillary tube of any type and size of split/window type 1/1.5/2.0 TR AC complete all as specified and directed .
S&F copper capillary tube of appropriate quality and size to match in existing including jointing, brazing and testing suitable for window/split type AC's of 1/1.5/2.0 TR capacity including taking down old U/S one complete all as directed.
Dismantling of unserviceable fan motor from the Air conditioner of 2.0/1.5/1.0 Tonne capacity and re-winding of fan motor with appropriate gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing the same complete all as specified and directed by Engr-in-Charge.
S&F of starting capacitor of 80/100 MFD capacity, AC 240 volts and 50 Hz including taking down of old unserviceable capacitor for 1.5/2.0/1.0 Tonne AC complete all as specified and directed by Engr-in-Charge. Make : Universal/sarada/power.
S&F of running capacitor of 36 MFD capacity AC 240 volt and 50 Hz including taking down of old unserviceable capacitor for 1.0/1.5/2.0 Tonne AC complete all as specified and directed by Engr-in-Charge. Make : Universal/sarada/power.
S&F of running capacitor of 40,MFD capacity AC 240 volt and 50 Hz including taking down of old unserviceable capacitor for 1.0/1.5/2.0 Tonne AC complete all as specified and directed by Engr-in-Charge. Make : Universal/sarada/power.
S&F of running capacitor of 45,MFD capacity AC 240 volt and 50 Hz including taking down of old unserviceable capacitor for 1.0/1.5/2.0 Tonne AC complete all as specified and directed by Engr-in-Charge. Make : Universal/sarada/power.
S&F of running capacitor of 50+ 6,MFD capacity AC 240 volt and 50 Hz including taking down of old unserviceable capacitor for 1.0/1.5/2.0 Tonne AC complete all as specified and directed by Engr-in-Charge. Make : Universal/sarada/power.
S&F of running capacitor of 55+ 6,MFD capacity AC 240 volt and 50 Hz including taking down of old unserviceable capacitor for 1.0/1.5/2.0 Tonne AC complete all as specified and directed by Engr-in-Charge. Make : Universal/sarada/power.
S & F of thermostat switch to match with the existing Window type Air conditioner of capacity 1.5 /1.0/2.0 Tonne including taking out of old u/s one complete all as specified and directed by Engr-in-Charge. Make : Infoss/Ranutrol.
Taking out of old unserviceable relay of any type & supply and fixing of relay AC 230 volt single phase for window/split type 1 TR/1.5 TR AC complete all as specified and directed by Engr-in-Charge. Make : Ranutrol/Sriram/AE/Microtech.
S&F of drain pipe with drain cap of window& split type AC 230 volt, single phase for (1/1.5/2.0 TR ) including taking down old U/S one complete all as specified and directed by Engr-in-Charge.
Taking out of old unserviceable strainer and supply & fixing of new strainer including testing complete all as specified and directed by Engr-in-Charge.
S&F of Air filter for 2.0/ 1.5/1.0 Tonne AC including taking down old U/S one complete all as specified and directed by Engr-in-Charge.
Taking out of worn-out blower fan from Window & split type of AC like 1/1.5/2.0 TR capacity & S/F new Blower Fan all as specified and directed by Engr-in-charge.
Taking out & S&F of blower Runner suitable for window & split 1/1.5 / 2.0TR capacity complete all as specified and directed by Engr-in- charge.
S&F of front grill to match with the existing Window type , including taking down old U/S one complete all as specified and directed by Engr-in-charge.
Scrapping of old painted surface of window type AC 1.5/1.0 /2.0 tonne capacity dusting cleaning thoroughly and spray painting with two coats of synthetic enameled paint over a coat of red oxide primer to match with the existing colour complete all as directed by Engr-in-Charge.
Taking out of choked condenser coil/ cooling coil unit from 1.5/1.0 /2.0 tonne capacity of Window and Split type Air conditioner, servicing cleaning thoroughly with Nytrozen & chemicals and air pressure and re-fixing/brazing in existing position all as specified and directed. Note :- Refrigerant as required to be measured & paid separately.
Taking out of worn-out and corroded portion of Window type Air conditioner body/base pan and fabricating by cutting, bending, welding, machining etc of existing PGI/MS sheets of thickness not less than 1.2mm to bring back the original shape as and where necessary suitable for existing design conditions including painting by two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply only compressor oil complete all as specified and directed. Make: Freezol/bajaj (D-catillery).
Supply and filling refrigerant gas R-22 for AC Plant complete including testing all as specified and directedby Engr-in-Charge.
Charging only refrigerant R-22 to Window / Split type Airconditioner after vaccumaziming the system thoroughly, sealing and leak testing complete all as specified and directed. Note : Refrigerant shall be measured and paid separately.
S&F of contactor assembly for 2.0 /1.5/1TR split type AC single phase 230 volt condensing unit of any make including taking down old U/S one complete all as specified and directedby Engr-in-Charge.
S&F of relay assembly for 1.5/2 TR split type AC of any make including taking down old U/S one complete all as specified and directedby Engr-in-Charge.
Repairing of electronic control circuit board of blower unit of split type AC 1.5/2.0 TR capacity of suitable for split AC including taking down old U/S one complete all as specified and directed.
Taking out window type AC from the existing place for complete servicing and minor repair to minor circuital wiring, oiling and greasing, cleaning (condenser, blower motor, evaporator, etc. externaly) and also cleaning with air pressure using chemical with fresh water and dry up properly and refixing in original position including testing complete.(Each unit Once in every three months )
Taking out split type AC from the existing surface for complete servicing, cleaning with minor repair cooling coil, electric circuit, oiling, greasing, cleaning with air pressure, cleaning with chemical and wash with fresh water and dry up proper and refixing the same of any make and capacity complete all as specified and directed. (Each unit Once in every three months )
Fixing only window /split type AC of any make/capacity including removing existing unserviceable wooden frame and providing new ply wood frame of 6mm thick and reinstalled with New wooden frame ,screw and with electrical connection including painting with two coats of synthetic enamelled paint over a coat of pink primer on one side of ply wood complete all as specified and directedby Engr-in-Charge. Note: window type/split type AC will be provided/supplied by the department.
Taking out window type AC from site after disconnecting all electrical connection and supply & fix of new cabinet cover as per same size and fasten with proper nuts, bolts as per specified including taking down old u/s one and re-installation the same in position with electrical connection and commissioning, testing complete all as specified and directed by Engr-in-charge.
S&F of power supply unit consisting of starter with 11-18 Amp over load protection, MCB of 25 Amp with socket complete for AC 240 Volt single phase including taking down old U/S one complete all as specified and directedby Engr-in-Charge. Make: North west /Crabtree.
Taking out Water cooler from the existing place for repairing of compressor, servicing, and refixing the repaired compressor, leakage testing, vaccummision the system gas charging completely complete all as specified and directedby Engr-in-Charge. . Note: Refrigerant measured separately.
S&F Bush of fan motor for water cooler of capacity 40/80 Lts including taking down old U/S one complete all as specified and directed by Engr-in-charge.
M&L for fan capacitor for water cooler with suitable rating including taking down old U/S one complete all as specified and directed by Engr-in-charge.
Dismantling of unserviceable fan motor from water cooler of any capacity and re-winding of fan motor with appropriate gauge of super enameled copper conductor to match with the existing design including overhauling, testing and re-fixing the same complete all as specified and directed by Engr-in-charge.
Taking out of U/S starting capacitor for water cooler of 80/40 capacity and S/F of new starting capacitor to match with the existing complete all as specified and directed by Engr-in-charge.
Taking out of U/S running capacitor from 80/40 Ltrs cap water cooler and S/F of new capacitor of capacity 10 MFD (suitable for 1/3 HP) complete all as specified and directed by Engr-in-charge.
Taking out unserviceable relay from water cooler of capacity 80/40 Ltrs capacity (for 1/3 HP compressor) and S&F of new relay to match with the existing complete all as specified and directed by Engr-in-Charge.
Taking out of unserviceable OLP & S/F new OLP to water cooler of capacitor 80/40 Ltrs complete all as specified and directed by Engr-in-charge.
Taking out of unserviceable thermostat switch & S/F of new thermostat switch to the water cooler of any capacity complete all as specified and directed by Engr-in-charge.
Flashing of choked/condenser thoroughly with nitrogen pressure refixing the same with proper brazing & leak testing complete all as specified and directed by Engr-in-charge.
S & F copper capillary tube for water coolers including taking out of old u/s tubes complete all as specified and directed by Engr-in-charge.
Dismantling of worn out outer body of water cooler and repairing by replacement to worn out portion of the sheet metal body by welding/fabricating with approved quality and 1.6mm thick of MS Sheet to match with the existing shape including, refixing of all the dismantled enclosures of the water cooler in position including testing, painting and commissioning complete all as specified and directed by Engr-in-charge.
Taking out of existing worn out and perished rubber gasket of water cooler tank cover and S & F of new gasket as per existing sample for any capacity of water cooler complete all as specified and directed by Engr-in-charge.
Taking out of existing worn out and unserviceable water faucets of any type 15 mm bore and S & F of cast copper alloy chromium plated push type / lift tap water faucets of 15mm bore complete all as specified and directed by Engr-in-charge.
Taking out of existing worn out and U/S float valve 15mm bore of any type and S & F of ball valve of 15mm dia including inlet nipple and connecting unions etc complete all as specified and directed by Engr-in-charge.
Taking out of worn out drain pipe including drain tray and repair the same and drain pipes to match with the existing for any capacity of water coolers complete all as specified and directed by Engr-in-charge.
Taking out of old unserviceable top cover lock of water cooler of any capacity and S&F of new top cover lock to match with the existing complete all as specified and directed by Engr-in-charge.
Taking out of existing unserviceable compressor sealed unit from refrigerator of 165/190 (Ltrs) 1/8th capacity and Repairing of compressor for Refrigerator, servicing, flashing refixing the after leakage testing, vaccummision the system gas charging complete all as specified and directed by Engr-in-Charge. Note: Refrigerant measured separately
Taking out of unserviceable compressor sealed unit from refrigerator of capacity 286/300/310 ltrs (1/6th HP) and Repairing of compressor for Refrigerator, servicing, flashing refixing the repaired compressor after leakage testing, vaccummision the system gas charging complete all as specified and directed by Engr-in-Charge. Note: Refrigerant measured separetly. complete all as specified and directed by Engr-in-Charge.
S&F of new compressor of capacity 165/190 ltrs ( 1/8 HP) for refrigerator after testing complete all as specified and directed by Engr-in-Charge. Make: Kelvinator/Voltas/LG.
S&F of new compressor of capacity 286/310 ltrs ( 1/6 HP) for refrigerator after testing complete all as specified and directed by Engr-in-Charge. Make: Kelvinator/Voltas/LG.
Removing of open type relay and supply and fixing of new open type relay suitable for 165/185Ltr capacity refrigerator complete all as specified and directed by Engr-in-Charge.
All as per item No. 59 here in before but capacity 286/300/310 ltrs.
Taking out of unserviceable thermostat switch & supply and fixing of thermostat for refrigerator of 165 to 310 Lts capacity complete all as specified and directed by Engr-in-Charge.
Taking out of old unserviceable over load protector and S/F of new overload protector suitable for 165/310 Lts capacity of refrigerator to match with the existing design complete all as directed by Engr - in - charge.
Taking out of unserviceable lamp holder including lamp case and S & F of new pigmy lamp holder and lamp case to match with the existing, suitable for refrigerators of any capacity complete all as specified and directed by Engr-in-Charge.
Taking out of unserviceable compact box type relay with OLP from refrigerators of capacity 165/310 ltrs and S & F new compact box type relay for refrigerators of 165 to310 Lts capacity complete all as specified and directed by Engr-in-Charge.
Supply only Refrigerant - (R-134A) OR R32a complete all as specified and directed by Engr-in-Charge.
Taking out of old unserviceable strainer of refrigerators of any capacity including supplying and fixing of new strainer of approved quality to match with the existing complete all as specified and directed by Engr-in-Charge.
Cutting of choked/ worn-out condenser/ vaporator and cleaning thoroughly cooling coils including evaporatoring coils etc. with using chemicals & air pressure including flashing the system & re-fixing/ brazing and replacement of required quantity tubes of appropriate size & quality complete all as specified and directed by Engr-in-Charge. NOTE: capillary tubes & refrigerent to be measured& paid separately.
Taking out of old unserviceable door lock of refrigerator of any capacity & S/F of new door lock to match with the existing size complete all as specified and directed.
Taking out u/s cooling coil and Supply and Fixing cooling coil with condenser assembly for refrigerator of any capacity as per existing samples complete all as specified and directed.
S&F Adjustable shelves for refrigerator of any capacity as per existing samples complete all as specified and directed by Engr-in-Charge.
S&F Bottle retainer/shelves for refrigerator of any capacity as per existing samples including taking down old U/S one complete all as specified and directed.
S&F door handle for refrigerator of any capacity as per existing samples including taking down old U/S one complete all as specified and directed.
S&F freezer door as per sample including taking down old U/S one complete all as specified and directed.
S&F chill tray of any type/ capacity/ make as per sample including taking down old U/S one complete all as specified and directed.
S&F vegetable tray of any type/ capacity/ make as per sample including taking down old U/S one complete all as specified and directed.
S&F Egg tray of any type/ capacity/ make as per sample including taking down old U/S one complete all as specified and directed.
S&F ICE tray of any type/ capacity/ make as per sample including taking down old U/S one complete all as specified and directed.
S&F Capillary tube size 0.36" dia to any type of refrigerators complete all as specified and directed by Engr-in-Charge. .
S&F in repalcement of blower motor by taking down of the outer unit of split AC of capacity 1/1.5 TR testing complete all as specified and directed by Engr-in-charge.
S&F in repalcement of blower fan by taking down of the outer unit of split AC of capacity 1/1.5 TR testing complete all as specified and directed by Engr-in-charge .
Repairing of compressor 2.5 TR to 5 TR. Capacity for 3 phase Tower Ac.
Cooper pipe with insulation kits 1/2"
Cooper pipe with insulation kits 3/8""
Cooper pipe with insulation kits 5/8"
Cooper pipe with insulation kits 1/4"
Replacement of Inner runner Motor by taking down the inner unit of split AC of capacity 1/1.5 TR.
Replacement of Remote Control Circuit by taking down the inner unit of split AC of capacity 1/1.5 TR.
S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 4 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 4sqm as earth lead drawing into rigid non metalic PVC conduit of size 20mm dia including taking down old unsv. Note: Two run of 4 sqmm cable and one run of 4 sqmm cable will be measured as single length.
All as per item No. 88.00 but with two run of single core 6 sqmm and one run of 6 sqmm cable complete.
Taking down the Outer Unit of Split AC. Of capacity 1/1.5 TR. Dismentaling the same and repalce the following parts as directed by Eng - in-charge. (a) Replacement of base plate
(b) Replacement of cabinet
(c) Replacement of condenser
Taking down the Inner Unit of Split AC. Of capacity 1/1.5 TR. Dismentling the same and replace the following parts of Inner Unit. (a) Replacement of Cooling coil of Inner Unit.
(b)Replacement of Front Cabinet
(c) Replacement of Runner of Inner unit.
Dismantling of existting 1 X 18TR compressor unit complete after disconnecting all the electrical connection of central type AC Plant (Compressor model 4-65 SMC), thoroughly checking of defective parts and overhauling the complete compressor unit with replacement of unserviceable spare with a new one suitable for compressor model 4-65 SMC, re-assembling of the same and testing complete on load complete all as specified and as directed. Note : (i) Any minor parts like gasket, screws, nuts, bolts etc required to be replaced shall be provided by the contractor and the rates for the same is deemed to be included in the rates quoted. (2) Major spare parts like as piston, connecting rod, oil stainer, D Valve etc will be meausred and paid separately s "Supply only" items under following:-
(a) Piston complete with ring and gudgen pin.
(b) Connecting rod with big end bush.
(c) Cylinder linear with suction valve.
(d) Guide for discharge valve.
(e) Discharge valve assembly.
(f) Shaft seal.
(g) Oil stainer.
(h) Suction pipe for oil pump.
(j) Dischagre pipe for oil pump.
(k) Suction strainer.
(l) Sealing ring set.
(m) Suction Discharge reed.
(n) Piston ring.
(o) Front & rear bush (main bush).
(p) Oil pump pinion & shaft.
(q) Bottom end Bush.
Supply only compressor oil capilar 'D' grade 68. Make : Power / Bajaj.
Supply only refrigerant gas F-22 complete all as directed. Make: Mafron/Floron .
Repairing of control pannel board of 2 X 18 TR capacity central AC plant by replacement or worn out wiring with new cables of existing sizes including taking down old rusted / unserviceable electric fittings/ accessories and testing complete all as specified and as directed. Note:- Spare shall be measured and paid separately as "Supply only ' items as following:-
(a) TP contactor MN-16 Make- L&T.
(b) TP contactor MN-25 Make- L&T.
(c) Indicator lamp.
(d) Push switch.
(e) Toggle switch.
(f) 2NO+2NC Make- L&T.
(g) Overload relay 20-40A Make- L&T.
(h) Overload relay 13.2-20A Make- L&T.
(j) Overload relay 6 - 9.3A. Make-L&T.
(k) FF type fuse link 32 A. Make- Cuttler hammer / L&T.
(l) MCCB (DPX X 160 ) 100 Amp , Make-L&T
(m) Single phase preventer
(n) DP DT switch 10 amp
(o) Star delta timer ,Make-L&T
(p) Connector 100A
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volt grade 6sqmm 3 core complete all as specified and as directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volt grade 10sqmm 4 core complete all as specified and as directed.
Disconnecting all electrical cables from air handling unit of capacity 2 x 18TR, dismantling the side covers or AHU, taking out the blower motor from its position, cleaning the cooling coil initially with hand blower, spraying soap solution and finally with fresh water, refixing the blower motor in position including checking of alignment and re-connection of all the cables including testing complete all as specified and as directed. Note : Repairing / Servicing of blower motor shall be measured and paid separately as per the relevant items of this schedule.
Dismantling the blower motor of capacity 10HP suitable for 415V 3 Phase supply system,cleaning completely all the parts, taken out burnt out winding and fresh winding with super enamelled copper wire of existing sizes including varnishing, re-assembling of the motor by replacement of ball bearings including painting of one coat synthetic enamel paint of approved colour and testing complete all as specified and as directed. Note:- (i) Rates are inclusive of transportation charges for to and fro, cost of petty items like oil, grease, packing materials etc. (ii) Bearing will be measured and paid separately under relevant item of this schedule as "Supply only" Items.
Dismantling of suction & discharge valve assembly complete and overhauling including adjustment and replacment of tafflon seal and replacement of suction and dischagre reeds complete and refix in original position and testing on load complete all as specified and as directed.
Materials and Labour Pressure testing of compressor including liquid line after pump down the whole gas charging system and collecting the refrigerant in empty cylinder, taken out compressor oil, checking of liquid line, necessary repairing of liquid line by soldering / brazing if necessary, charged N2 gas and kept for 12hrs under pressure, then taken out N2 gas, vacuum test caried out for another 12hrs to obtain satisfactory result, refilling of compressor oil upto desired level and recharging of refrigerant in the system untill the desired working presure achieved complete all as specified and as directed. Note : Compressor oil, refrigerant, MS liquid pipe line and controlling valve will be measured and paid separately under the relevant item of this schedule.
De-scaling of shell and tube of the condensers (Make : ACCEL or equivalent) by providing necessary acid and other allied cleaning materials and cleaning with nylon brush to remove the scale formed inside the copper tube including replacement of unserviceable safety valve, all gland packing, gasket etc and testing complete after de-scaling complete all as specified and as directed.
Dismantling the unserviceable / broken copper tube of existing suction and discharge end of compressor to high / low pressure cut out switches, oil and water pressure cut off switches including flare nuts and replacement of the same with new copper tube of existing size including flare nut and refixing the same and testing complete all as specified and as directed.
Supply and Replacement of cooling tower pump motor V-belt of size A - 120 complete all as specified and directed by Engr- in- charge. Make: Dunlop/Fenner/Falcon Mexik
Supply and Replacement of blower motor V-belt of size B - 92, including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make: Dunlop/ Fenner/ or Equivalent
Supply and Fix High pressure cut out switch, Model : MP-5, including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make : Danfoss/ indfoss.
Supply and fix Low pressure cut out switch, model : MP-1 including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make : Danfoss/ Indfoss.
Supply and Fix Oil pressure cut out switch, including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make : Danfoss/ indfoss.
Supply and Fix Water pressure cut off switch, including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make : Danfoss/ indfoss.
Supply and Fix Solenoid valve of existing capacity and model of including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make: Danfoss/Honeywell/indfoss.
Supply and Fix Humidistate of existing size and type of including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make: Danfoss/Honeywell/indfoss.
Supply and Fix High pressure gauge 4" dia of existing range including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make : Fibig /Guru / Gluck .
Supply and Fix Low pressure gauge 4" dia of existing range of including taking out the old unserviceable one complete all as specified and directed by Engr- in- charge. Make : Fibig /Guru / Gluck .
Material and labour Repairing of monoblock pump set, three phase of capacity 5HP opening out from foundation, shifting to workshop for repair, reassembling complete after repair, returning back to existing place /position, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Note: (i) Spares for pump and motorshall be measured and paid separately under relevant items of these schedule as "Supply only" items. (ii) Rates are inclusive of transportation charges for to and fro, cost of petty item like grease, packing materials etc.
Supply only Gun metal bush suitable for three phase 5HP capacity monoblock pump set complete all as specified and as directed.
Supply only impeller(GM) suitable for 3 Phase 5HP capacity monoblock pump set complete all as specified and as directed.
Supply only Bearing 6310 complete all as specified and as directed. Make : SKF or equivalent.
Supply only Bearing 6309, complete all as specified and as directed. Make : SKF or equivalent.
Dismentaling of cooling tower of 2X18 TR capacity & repairing / replacement of following items complete all as specified and as directed. (a) Replacement of bearing (b) Motor repaire/Heat varnishing (c ) V Belt replace (d) Gear repairing (e) Nozel Repalce/Service (f) Fill repaire/repalcement (g) Repalce of float valve (h) Repalce of pulley (j) Cleaning & Servicing
Material and labour for removing and taking out of U/S Air filter from AHU,supply and fixing of new air filter by 5 micron washable net with size of 25"(Height)x28"(length)x2"(Breadth) complete all as specified and as directed.
Material and labour for repairing of AHU body by fabricating the bottom portion of AHU (Two side) after taking out of u/s GI sheet ,fabricating and fixing in the same place made by 22 gauge GI sheet size:14"(height)x72"(length) with nut , bolts and washers and painting the AHU properly complete all as specified and as directed.
Material and labour for taking out u/s canvasof AHU by cutting of nuts and bolts,making and fixing the same by canvas cloth,size :18"(Height)x24"(length)x4 side complete all as specified and as directed.
Material and labour for taking out u/s fresh air damper ,fabricating and fixing the same by 22 gauge GI sheet ,size :42"(height)x42"(length)x2"(Breadth)with louvers and on/off handle complete all as specified and as directed.
Material and labour for taking out of u/s fresh air duct,fabricating and fixing the same by 22 gauge GI sheet,size:28"x36"x25"(HxLxB) with necessary allignment and complete all as specified and as directed.
Material and labour for taking out u/s return air damper ,fabricating and fixing the same by 22 gauge GI sheet, size :28"x25"x4"(HxLxB) with louvers and on/off handle complete all as specified and as directed.
Material and labour for taking out of u/s return air duct,fabricating and fixing the same by 22 gauge GI sheet,size:54"x192"x42"(HxLxB) with necessary allignment and complete all as specified and as directed.
RADHA ENTERPRISE
KWALITY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .