Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | ₹15.7 L Quoted ₹16.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹16.7 L+₹19,494 (1.18%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | ₹16.7 L+₹19,494 (1.18%) | L2 | Rejected-AOC L2 |
| 3 | L3₹17.9 L+₹1.4 L (8.72%)Rejected-AOC | ₹17.9 L+₹1.4 L (8.72%) | L3 | Rejected-AOC L3 |
| 4 | L4₹21.5 L+₹5.1 L (30.7%)Rejected-AOC | ₹21.5 L+₹5.1 L (30.7%) | L4 | Rejected-AOC L4 |
| 5 | L5₹22.2 L+₹5.8 L (34.9%)Rejected-AOC 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹22.2 L+₹5.8 L (34.9%) | L5 | Rejected-AOC L5 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
17 Aug 2023, 6:00 pmClosed
GE Bharatpur
GE Kanjoli line Bharatpur-321026
COMPREHENSIVE REPAIR AND MAINT OF CEILING FAN WATER HEATER BLDG LIGHTS EXHAUST FAN INTERNAL ELECTRIFICATION WITH FIXTURE/FITTINGS, SUBMAIN WIRING, MCB/DB EARTHING LED LIGHT FITTING AND ALLIED WORK AT PARADE GROUND UNDER GE BHARATPUR
2023_MES_606629_1
8292/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹54,000
Yes
25 Sept 2023
28 Jun 2023
19 Aug 2023
28 Jun 2023
17 Aug 2023
4 Aug 2023
29 Jun 2023 - 20 Jul 2023
Amount
Disconnecting & taking down the ceiling fan of any sweep for carried out preventive maintenance and re hanging the same after cleaning the dust etc with air pressure, cotton cloth & brush, taking out ball bearing and bush, cleaning with kerosine oil, lubricating greasing, oiling, cleaning to winding including supply and replacement of nuts, bolts, rubber seal, split pin, connector and copper cable PVC size 3 core 0.5 Sqmm upto required lenght from ceiling rose to connector of ceiling fan including hanging, connecting up and testing all as directed.
M&L for spray painting of ceiling fan of any sweep complete with blades, down rod etc with synthetic enamel paint of approved colour by spraying including filling cavaties with filler, preparation of surfaces cleaning all dust etc and writing of MES No of size not exc 5cm thick using black enamelled paint all as directed.
M&L for cutting and dismantling the existing winding of ceiling fan of 1200/1400mm sweep and rewinding with super enamelled copper winding wire of suitable gauge including varnishing, lubricating, greasing, oiling and testing including replacement of ball bearing-02 Nos complete all as directed by Engr-in-charge.
Supply and replacement of following parts/components suitable for ceiling fan 1200/1400mm sweep :-
Capacitor 2.5/3.5 mfd, oil filled, 400V AC, 50 HZ, 85 degree C ISI marked Make : Asian/Unistar/Usha.
Hanging clamp complete with rubber real Make as existing /sample kept in AGE E/M office complete all as directed by Engr-in-charge.
Fan Hook complete as standard real existing in market for fixed in GE Pipe/Existing Channel
Ceiling fan blade suitable for ceiling fan of any sweep (set of three blades)
Down rod 50 cm long 15mm internal dia heavy duty duly painted including hanging clamp, rubber ring, nut and bolts complete with canopy
Disconnecting & taking down the exhaust/wall fan of any sweep for carried out preventive maintenance and re hanging the same aftercleaning the dust etc with air pressure, cotton cloth & brush, taking out ball bearing and bush, cleaning with kerosine oil, lubricating greasing, oiling, cleaning to winding including supply and replacement of nuts, bolts, rubber seal, split pin, connector and copper cable PVC size 3 core 0.5 Sqmm upto required lenght from ceiling rose to connector of ceiling fan including hanging, connecting up and testing all as directed. (Note for Srl item No 01 and 1.1 here in before : (i) Minor parts such as nut, bolt, washer,rubber seal, split pin, connector copper cable pvc insulated 0.5 sqmm 3 core are deemed to included with unit rate of item.(ii) Parts/components replaced other than mentioned above will be measured and paid separately under respective items. (iii) The services of ceiling fan carrying out door to door.(iv) After completion of work all fans shall be tested to the entire satisfaction of Engr-in-charge Note:Major item such as ball bearing, capacitor, fan blade etc shall be measured and paid seperately.)
M&L for spray painting of exhaust/wall fan of any sweep complete with blades, down rod etc with synthetic enamel paint of approved colour by spraying including filling cavaties with filler, preparation of surfaces cleaning all dust etc and writing of MES No of size not exc 5cm thick using black enamelled paint all as directed.
M&L for cutting and dismantling the existing winding of exhaust/wall fan of any sweep with super enamelled copper winding wire of suitable gauge including varnishing, lubricating, greasing oiling testing incl replacement of ball bearing/GM bush as requiredcomplete all as directed by Engr-in-charge.
Supply and replacement of following parts/components suitable for exhaust fan 200-450mm sweep(PVC & Steel ,body) :-
Capacitor 4 mfd, oil filled, 400V AC, 50 HZ, 85 degree C ISI marked Make : Asian/Unistar/Usha.
Fan blade set for exhaust fan of 200-300mm sweep.
Fan blade set for exhaust fan of 380-450mm sweep.
Exhaust fan mounting bracket incl nuts,fastners
Exhaust fan motor of 200-300mm sweep as per existing PVC exhaust fan
Exhaust fan motor of 380-450mm sweep as per existing steel body exhaust fan
Louvers and shutters of PVC/ MS as per existing exhaust fan
Taking down the existing unserviceable water storage type geyser of capacity 25/35/50 ltr by disconnecting from water connection and reinstallation at the same location after carrying out necessary repair/replacement of unserviceable parts such asReset type thermal cut out, fusible plug fuse,Non return valve vertical type spring loaded, ISI marked,Iron neck ring, Brass inlet/outlet assembly complete without element and thermostat,Aperture plate made of brass,Element holding clip made of mild steel,Bolts with washer 25mm long for aperture plate,Rubber gasket, plate type for aperture plate, Indicator bulb square/round type complete with necessary connection wire of red & green colour complete, Pressure release valve of size 15mm, ISI marked, Anti vaccum valve with GI tee of 15mm bore, ISI marked, including one coat of spray painting with synthetic enamel paint and testing complete all as directed by Engr-in-charge.
Supply and replacement following parts required for repair of the geyser water storage type 25/35/50 ltr capacity.
Thermostat switch adjustable type.
Water storage tank made out of special laminated texture finished body with covering of non corrosive protection on both sides of sheet with 100% pure Salem stainless steel sheet/electro statically powder coated body made of heavy gauge CRCA sheet.
Heating element 1500/2000W with rubber ring clamping screws etc
M&L for removing unserviceable grouted "Anchor" type bolts and nuts from the wall and S&F new "Anchor" type bolts (04 Nos of 12mm dia) grouted properly in wall to hold 25/35/50 ltr capacity water storage type geyser with and including nuts and washers and marking good the disturbed surface in cement mortar 1:3 complete all as directed by Engr-in-charge.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc and making good, cutting exc 10cm and not exc 20cm girth in brick or stone wall including making same texture of cutting surface as per existing wall complete all as directed by Engr-in-charge.
S&F in repair PVC cable 3 core copper conductor of size 2.5 Sqmm to water storage type geyser of capacity 25/35/50 ltr including taking out old cable. Make : Plaza/ Gloster/ Finolex/ NICCO.
Taking down U/S plug top and S&F new 3 pin plug top 16 amps, 230 volts, ISI marked. Make : Anchor/Kinjal /cona/ Recold/ Leader.
Taking down U/S plug top and S&F new 3 pin plug top 5 amps, 230 volts, ISI marked. Make : Anchor/Kinjal /cona/ Recold/ Leader.
Taking down carefully copper/aluminium point wiring (light, fan, bell,same board, independent or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc.
Dismantling of old U/S sub main wiring and service wire of any size & make.
Dismantling of old U/S rusted main switch/DB of any size capacity and make.
M&L conceled point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe size not less than 20 mm dia with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface and making good the disturbed surfaces of wall/ceiling by means of Wall putty and matching colour of existing wall, PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards/ sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed for the following :-
One light point controlled by one way switch.
One fan point controlled by one way switch.
One 3 pin 6 Amp socket point outlet on the same board with other switches
One 3 pin 6 Amp socket point outlet on the independent board
One bell/buzzer point controlled by one push button.
One light point controlled by 2 way Switch
All as per item No 19 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.
M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly for the following :-
One light point controlled by one way switch.
One fan point controlled by one way switch.
One 3 pin 6 Amp socket point outlet on the same board with other switches
One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 21 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps switch socket outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly.
S&F ceiling rose surface bakelite three terminal ISI marked including suitable size of PVC board.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type multi purpose flush type 230 volt
S&F switch piano flush button single pole one way 6 Amps 230 volt grade
S&Fswitch, 15 Amp flush type, complete all as specified and directed.
S&F socket 3 pin 15/16 Amps flush type, complete all as specified and directed.
S&F bell push flush type 5 Amps 230 volts grade.
M&L bell multi musical type 230 volts grade.
S&F step type electronic fan regulator EME type 450 watt.
S&F modular socket -6 Amps 2 /3 pin 2 module 230 volt.
S&F modular switch 1 way 6 Amps 1module 230 volt grade.
S&F modular switch 2 way 6 Amps 1module 230 volt grade.
S&F modular socket 2 /3 pin 16 Amps 2 module 230 volt.
S&F modular Switch 15/16 amp ,230V
S&F modular bell push flush type 5 Amps 230 volts.
S&F modular step type electronic fan regulator 2 module 80 watt.
S&F white cover plate with frame,2 module
S&F white cover plate with frame,3 module
S&F white cover plate with frame,4 module
S&F white cover plate with frame,6 module
S&F white cover plate with frame,8 module
M&L concealed submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories.
M&L concealed submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories.
Supply and fixing in repair of distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt, 415V of the following DBs :-Makes -L & T / Legrand.
4 way TPN with busbar 415 volts (double door)
8 way SPN with 200 amps rated busbar 240 volts (double door type).
4 Way SPN with 200Amp rated busbar 240V (Double door type)
S&F in repairs MCB's of following capacity :-
MCB TPN 63 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
MCB TPN 32 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
MCB SP 6-32 Amps, 240 volts,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
MCB SPN 6-32 Amps, 240 volt,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
MCB SPN 40 Amps, 240 volt,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
Taking out old unsv T/L and Supply & fixing LED 20 watt LED tubelight fitting retro fit type with replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed. make: Cromption or equivelent in Phillips/Surya/Helonix/Havells
Taking out old unsv T/L and Supply and fixing sensor based LED 20 watt LED tubelight fitting batten type with rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed. make: Cromption Cat No:R20RBA or equivelent in Phillips/Surya/Helonix/Havells
M&L in repair of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all incl 9watt LED lamp as directed by Engineer-in-charge.
S&F in repair of modular enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of SP 25 Amps, 240 volts.
S & F in repair of street light GI bracket of 0.6 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole as directed.
S&F in repair of 35/36 watts LED street light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source with warranty option of 5 years and suitable drivers etc and connecting with 2.5 sq mm solid aluminium conductor PVC insulated twin core weather proof cable from fittings to over head lines or to the jucntion box and fixing to complete all as specified and directed
S&F in repair of LED light fitting 14 W,230V decorative wall mounting type with multicolour ABS housing with poly carbonate rings and glass shade with lamp holders connector block,etc complete with all accessaries pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fixing in repair of LED light fitting mirror type with high out put diffuser 1 feet x 05 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing in repair of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing in repair of LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
M & L for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.65 Mtr below the ground level connected to GI earth wire 4mm dia by means of bolts, nuts and washers protected by GI tubing light grade 15 mm dia uptoTest point, 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( Note:- Up to 7.5 Mtr length of pipe of 15 mm dia and GI wire shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5) will be measured separately under respective item.
M/L for taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT cable of any size.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:-
35 Sqmm x 3.5 core
25 Sqmm x 4 core
16 Sqmm x 4 core
10 Sqmm x 2 core
Supply and fix single phase smart meters with polycarbonate cover 230 V, 5-60Amp, accuracy class-I 50Hz, conforming to IS16444, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH complete incl taking down old unsv eletric meter & depost to MES store yard
Ditto but 3 Phase, 415 volt 10-60Amp .
Supply and fixing of single / Three phase meter box made of accrylic sheet complete all as specified and directed by Engr-in-charge.
Taking out old U/S MCCB/MCB DB box and Supply and install commnissioning and testing of distribution cum meter box indoor type, floor mounted factory made out of CRCA sheet thickness not less than 2.0 mm dully powder coated suitable for 6 No smart energy meter with provision of independent housing to each meter, making of qtr No on meter with each compartment to MCB SPN , power control wiring with minimum 10 Sqmm copper single core cable for each control from Main MCCB to meter and 6 sqmm copper single core cable from Meter to MCB SPN cable, gland suitable for distribution cum meter box with display glass to check the meter reading including disconnecting and taking out existing U/S meter box and making good to disturbed suraces complete including following accessories all as specified and directed (Servant Qtr Bldg) Incoming:- (a) MCCB 4 Pole, 415 V,Thermal Magnetic release, Adjustable type, 100 Amps with 16 KA rapturing capacity - 01 No. (b) 4P, Changeover switch, 415 volt, Cap-100 Amps - 01 Nos (b) Copper bus bar 4P 200 Amp current rating -1 set Outgoing :- (a) MCB SPN 40 Amp 240 volt -8 Nos (b) MCB SP 6-32 Amp 240 volt -5 Nos (c) Housing/compartment with polycarbonate box including Single phase ,230 Volt prepaid Smart Energy meter as per IS 16444capacity up to 60 Amp with in built sim for communication module for automatic metering system Complete-06 Nos (e) RYB Indication Lamp -1Set
Taking out old U/S MCCB/MCB DB box and Supply and install commnissioning and testing of distribution cum meter box indoor type, wall mounted factory made out of CRCA sheet thickness not less than 2.0 mm dully powder coated suitable for 2 No energy meter with provision of independent housing to each meter, making of qtr No on meter with each compartment to MCB SPN , power control wiring with minimum 10 Sqmm copper single core cable for each control from Main MCCB to meter and 6 sqmm copper single core cable from Meter to MCB SPN cable, gland suitable for distribution cum meter box with display glass to check the meter reading including disconnecting and taking out existing U/S meter box and making good to disturbed suraces complete including following accessories all as specified and directed (Single Offr Accn) INCOMMING :- (a) MCCB 4 Pole, 415 V,Thermal Magnetic release, Adjustable type, 100 Amps with 16 KA rapturing capacity - 01 No. (b) 4P, Changeover switch, 415 volt, Cap-100 Amps - 01 Nos (b) Copper bus bar 4P 200 Amp current rating -1 set Outgoing :- (a) MCB SPN 40 Amp 240 volt -3 Nos (b) MCB SP 6-32 Amp 240 volt -5 Nos (c) Housing/compartment with polycarbonate box incl 3 phase 415V,prepaid Smart Energy meter as per IS 16444 capacity up to 60 Amp with in built sim for communication module for automatic metering system Complete-02 Nos (e) RYB Indication Lamp -1Set
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and as directed by Engineer-in-Charge. (Taking out old brick from trenches shall be measured separately and deduction for brick shall be made on this account).
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
Taking out old unsv gang box and S&F Gang box switch socket combition for 5 Amp all as specified and directed.
Taking out old unsv gang box and S&FGang box switch socket combition for 15 Amp all as specified and directed.
Taking out old unsv copper conductor and S&F 1.5sqmm copper conductor all as specified and directed.
Taking out old unsv capacitor and S&F capacitor 2.5/3.5/4.0 mfd 240V ISI mark complete
Taking out old unsv socket and S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type multi purpose flush type 230 volt
Taking out old unsv switch and S&F switch piano flush button single pole one way 6 Amps 230 volt grade
Taking out old unsv socket and S&F Socket outlet 3 pin 15 amp flush type multi purpose flush type 230 volt
Taking out old unsv switch and S&F switch piano flush button single pole one way 16/15 Amps 230 volt grade
Taking out old unsv fan regulator and S&F step type electronic fan regulator EME type 450 watt.
Taking out old unsv modular socket and S&F modular socket -6 Amps 2 /3 pin 2 module 230 volt.
Taking out old unsv modular switch and S&F modular switch 1 way 6 Amps 1module 230 volt grade.
Taking out old unsv modular socket and S&Fmodular socket 2 /3 pin 16 Amps 2 module 230 volt.
Taking out old unsv modular switch and S&Fmodular Switch 15/16 amp ,230V
Taking out old unsv modular fan regulator and S&Fmodular step type electronic fan regulator 2 module 80 watt.
PD GUPTA AND COMPANY
M/S MAMTA CONSTRUCTIONS
unique traders
Allied Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .