| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹73 LAccepted-AOC 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | L-1 | Accepted-AOC Supply order placed on 12.04.2023 | |
| 2 | L-2₹81.0 L+₹8.0 L (11.0%)Rejected-Finance 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | L-2 | Rejected-Finance Agreement made with L-1 | |
| 3 | L-3₹81.3 L+₹8.3 L (11.4%)Rejected-Finance | L-3 | Rejected-Finance Agreement made with L-1 | |
| 4 | L-4₹96.7 L+₹23.7 L (32.5%)Rejected-Finance 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | L-4 | Rejected-Finance Agreement made with L-1 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
20 Jan 2023, 2:00 pmClosed
Executive Engineer, W.S. Mech. Division, Rewari
Executive Engineer, W.S. Mech. Division, Rewari
S.E. C. of 01 no 10 Cs Pump (P-4), 05 Nos. 30 HP and 02 Nos 60 HP LT induction motors, LTD Panels, cable of various sizes and other electrical equipments at Pump house DD-8, DD-9 Jaula Mr
2023_HRY_253288_10
64/6-A dated 09.01.2023
Open Tender
Pumps/Motors
Works
150 days
Executive Engineer, W.S. Mech. Division
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
₹1.3 L
Yes
10 May 2023
10 Jan 2023
20 Jan 2023
10 Jan 2023
20 Jan 2023
10 Jan 2023
Amount
Supply, errection and commissioning of 10Cs.(P-4) Axial/Mixed flow VT Pump of 960 RPM having static lift 29ft, incl. welding, HS nut-bolts etc. complete in all respect as per site requirement, with new delivery pipe (Length 28±1 feet)& siphon bend and as per approved specification of the deptt. (as per Annexure-A) (DD-8)
Supply, errection and commissioning of solid shaft squirrel cage LT 3 phase 415V induction Motor for continuous duty, vertical flange mounted of 60 HP of 6 pole, 980 rpm, TEFC Motor of IE 2 as per IS 12615. The colour shade shall be RAL 7031, suitable for existing 10Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) (At DD-8)
Supply, erection and commissioning of Hollow shaft squirrel cage LT 3 phase 415V induction Motor for continuous duty, vertical flange mounted of 30 HP of 4 pole,1470 rpm, TEFC Motor of IE 2 as per IS 12615. The colour shade shall be RAL 7031, suitable for 5Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) (For DD-8, DD-9 &Jaula Minor)
Supply, erection and commissioning of LTD panel with incomer of MCCB of 400 Amp., 4 pole 415 V, 50 Hz, with 2 No. 160Amp and 02 no. 80Amp. outgoing and having provision of additional D Plug socket of 63 ampere and lightening load along with all metering equipment CT’s of required capacity complete in all respect & as per makes and specifications approved as detailed in annexure-C.(At DD-8)
Supply, and laying of LT single core Aluminum Conductor 185mm2 XLPE Insulated, Armoured cable from Transformer to panel by providing suitable size thimbles at both ends. .(At DD-8)
Supply, and laying of LT single core Aluminum Conductor 95mm2 XLPE Insulated, Armoured cable from Transformer to panel by providing suitable size thimbles at both ends.(At DD-9,Jaula Minor)
Supply of LT power distribution panel with incomer of MCCB of 100 Amp., 4 pole 415 V, 50 Hz, 36 KA, CT ratio 200/5 MDU with 02 No. outgoing including 2 No. 50 Amp. MCCB and having additional provision of D Plug socket of 63 ampere and lightening load along with all metering equipment CT’s of required capacity complete in all respect as per makes and specifications approved by Irrigation & Water Resources Department, Haryana as detailed in annexure-C attached.( Jaula Minor)
Providing and fixing of Lightening Arrester with protection radios of 100mtr. Along with itsearthing as per the site requirement.(For DD-8, DD-9 &Jaula Minor)
Providing and fixing of chemical earthing by digging 200 mm bore, 20 feet depth complete with GI electrode with GI strip ( 02 nos. for LTDB panels starters & motors in pump house) and coke & salt etc. along with name plate complete as per requirement.(For DD-8, DD-9 &Jaula Minor)
Make of Pumps- Kirloskar, Wilo, Flowmore, WPIL, Xylem, GITA(upto 60 cs.) & Sintech(upto 60 cs.). Make of Motors - LV Motor- Marathon, ABB, Kirloskar Electric, Siemans, Crompton, Jyoti, BCH, Bharat Bijli. Make of Panels - LV Panel- Siemans, ABB, L&T, Schneider, G.E. C&S, Havells, BCH, Legrand, AE & PSG(upto 30 HP). Terms & Conditions:- 1. The tender rate will be inclusive all taxes as applicable including GST. 2. The tender rate will be for F.O.R. destination and inclusive of all incidental charges, enroute & at destination. Nothing extra shall be paid separately. 3. WWC@1% will be deducted from the each bill of the agency. 4. Department will not be responsible for non submission of BOQ / Bid Document online by due date, due to any fault of internet/ E-tendering. 5. Third Party Testing by T.P.I.A. will be carried out in the presence of departmental representative at the manufacturer premises and cost of the same will be borne by the successful agency. 6. The warranty of the work shall be as per Service Level agreement from the date of commissioning. 7. Time period for completion of work 5 Months from the issue date of order to proceed with the work. 8. Payment schedule, as per bidding documents & 70% payment be made as per pro-rata basis. 9. Payment shall be made on finished goods and not on casting only. 10. The material will be supplied as per drawing and newly approved technical specifications laid down in tender documents & subsequent submission by bidder in this regard. 11. Authorization from OEM (Pump, Motor) be attached if tenderer is not a manufacturer. 12. Each page of bid book will be signed by the tenderer as a token of acceptance of terms and conditions. 13. Bidders may visit to the sites before quoting the tender rates. 14. Bidders should have executed similar nature work in any Center Government / State Government/ Public Sector Undertaking / Central Autonomous Body for minimum value equivalent to 50 % of quoted value in last 3 years alongwith existing criteria as per bid i.e. bidder should have completed at least 25% of quantity of similar nature work. 15. ln case, the material offered for inspection by the firm fails to meet the specifications stipulated in NIT/order/Contract and the samples are rejected by the Inspecting Committee, the Department will have the right to levy a penalty at 0.1% of the total value of that particular item. 16. Bidders who will be rejected during technical scrutiny, will submit their representation within 5 days from issue of minutes of TSC. 17. Affidavit on Non Judicial Stamp Paper of Rs. 100/- duly certified by the Notary stating that the firm (name of the firm) has not been blacklisted/ debarred either in Government Departments/ Agencies in state of Haryana or Central Government Departments/ Agencies etc. as on the date of submission of the bid in the present tender. 18. Bidders should have average annual financial turnover of atleast 30% of estimated amount during the last 03 financial years, ending 31st March of previous financial year. This should be duly audited by Chartered Accountant. 19. Concession is given to Haryana based MSME’s, KVIU, Central or HPSE (as declared by industries Department Haryana) as in tender fee, EMD, Past Experience and eligibility criteria for turnover. Though they have to complete the job as per tender with warranty of 5 years or 12500 Hours which ever is earlier as per service level agreement. Only those MSME, KVIU, Central or HPSE(as declared by industries Department Haryana) will be eligible for this tender, those are authorized dealer or manufacturer of approved make of IWRD.
Avon Engineering Company
ace marketing pvt ltd
Sahil Engg. Works
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .