Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹32.7 L+₹1.7 L (5.56%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance Higher amount quoted | |
| 3 | L3₹38.0 L+₹7.0 L (22.6%)Rejected-Finance | L3 | Rejected-Finance Higher amount quoted | |
| 4 | Rejected-Technical 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | - | Rejected-Technical Rejected. incoorect DD uploaded | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected. Bidder has not addresed the application to CWE (A) Jaisalmer |
Tender Value
₹34.3 L
EMD Value
₹68,580
Closing Date
20 May 2020, 6:00 pmClosed
CWE (A) Jaisalmer
CWE (A) Jaisalmer
SPL REPAIR TO LIGHTENING CONDUCTOR FOR BLDG NO P-1120 AND P-1141 IN CERTAIN AREA AND SPL REPAIR/REPLACEMENT OF POLES AND LT CABLES WITH LIGHT AT CERTAIN UNITS AT MIL STN JAISALMER UNDER GE (A) JAISALMER
2020_MES_340140_1
83846
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (A) Jaisalmer
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (A) Jaisalmer
₹68,580
Yes
21 Jul 2020
22 Apr 2020
22 May 2020
22 Apr 2020
20 May 2020
6 May 2020
Amount
Taking down Unserviceable LT electric cable of any size from excavated treanches/over ground on pole/ wall including stone patti
Taking down Unserviceable Aluminium conductor wire of any size
Taking out old unserviceable Aluminium Strip of any size
Taking out unserviceable GI strip of any size
Taking out unserviceable Air Termination Roda of any size
Taking out unserviceable test Point Terminal Block etc
M&L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all a specified and directed by Engineer Incharge
M&L for Air termination, single pointed copper rod 12 mm dia and 300 mm long fixing with GI tubing of 0.5 meter long 25mm bore medium grade with necessary fixing arrangement such as welding, nut & bolt including fixing on roof by means of cement concrete type B-1 (1:2:4) of size 200X200X200mm complete all as specified and directed by Engineer Incharge
M&L for test point terminal block made of aluminium metal or phophorus bronze size 75X75X25 mm drilled and screwed including 3 Nos 8mm dia 25 mm long Hexagonal head screw complete all as specified and directed by Enigneer Incharge
M&L for galvanised iron strip 32X6 mm burried in ground with fixing nuts and bolts brazing etc complete all as specified and directed by Enigneer Incahrge
Supply, Transportation fixing and erection Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) and including making alternate white and black strips 30 cm height (Total 5 Nos) with two coats od synthetic enamel paint over a coat primer complete including taking down unservicebale LT pole any size from site complete all as specified and directed by Engineer Incharge
S&F highly efficient IP 66 and IS 10322/IEC-60598 LED street light with aluminium pressure dia cast housing to toughened glass in the front and peanut lense for batwing light distruction with integral electronic constant current driver, PF≥ 0.95 and system effiency ≥100 and CRI ≥70 suitable for 60 Wattage complete and including taking down unservicebale street light of any watt from the pole of any height etc all as specified and directed by Engineer Incharge Make:- Orient Cat Part No LSFS-060-C or equivalent. Note- LM80 certificate to be procured for the LED fitting before submitting claims for payment.
S&F in repair security light bracket with GI pipe medium grade of size 40 mm dia bend to shape of length 1.2 meter including flat iron clamp made of FI 40X6 mm, nuts and bolts washers etc dully painted with two coat of synthetic enamel paint over a coat of red oxide primer complete
S&F for pole mounting box made out of PVC FR Grade (Syntex) with bus bar -03 Nos for phase & 01 no for Neutral 32 Amps supported on insulators and one No MCB 6 Amps, claps made out of FI 25X6 mm nut, bolts and washers etc dully painted with two coat of synthetic enamel paint over a coat of red oxide primer including taking down unserviceble pole mounting box excluding encloseres etc all as directed by Engineer Incharge
S&F cable PVC insulated and PVC sheathed 1100 volt grade aluminium conductor 1.5 Sqmm to core etc complete all as specified and directed by Engineer Incharge
S&F GI pipe light grade of dia 40mm Laying in road and along with poles/walls for cable protections complete all as directed by Engineer Incharge
S&F GI pipe medium grade of dia 25mm Laying on poles etc complete all as directed by Engineer Incharge
Taking down Unserviceable Pin Insulator of any type/ any size from the site
Supply , laying & testing Cable XLPE insualated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminim conmdutor conductor and overall served with an outer sheath of PVC of cross sectional area 16 Sqmm 4 Core .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers all as specified & directed at site.
Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness will be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engineer-in-charge.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of stay assembly including necessary form work all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Labour only for fixing of existing guard wire between the poles complete fixing clamps all as specified and directed by Engineer Incharge
M&L for relaying of old retreaved/aluminium strip of any size after making it striaght and connecting properly with steel nuts & bolts complete all as specified and directed by Engineer Incharge
S&F in repair LT 1100 Volts Pin type, porcelain, vitreous, white, brown or green insulator height 100X65 mm including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for 550 volts grade
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
Supply, installation testing and commisioning LT Panel 415 volt for wire AC 50 Hz factory made, CPRI Approved floor mounted,outdoor type panel made out of MS sheet of size 3.15 mm thick of size suitable size for fixing of MCCB, Aluminum bus bar with having separetely locking arrangements duly with powder coated and mounted on an angle iron frame, 40 cm hright above ground level duly fixed with PCC etc, including contol wiring complete to accomodate including taking down Unserviceable LT Panel of any size from site and including the following accesories:
(a) 4 No's alumnium bus bar of rating 250 Amps mounted on heavy duty rubberised/porcelene support two set (Vertically and horizontaly)
(a) MCCB 160 Amps 35 kA(Ics=100%Icu) 4 Pole adjustable type -01 Nos. (incoming)Make: ABB,L&T,Legrand
(b) MCCB 100 Amps 35 kA (Ics=100%Icu) 4 Pole adjustable type -03 Nos. (Outgoing)Make: ABB,L&T,Legrand
(c) Digital type Ampere meter 0-50 Amp-01 No
(e) Indicating lamp LED type set of three -01 No
(f) PCC work complete
(g) Danger Notice board
Note :- All MCCB s to be ICS = 100% ILU
Anil Builders
Leelashah Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .