EXPRESSION OF INTEREST FOR SELECTION OF BACKEND PARTNER SYSTEM INTEGRATOR FOR SCHEDULE A CONSTRUCTION OF TYPE V QTRS 12 UNITS AT RAIL SADAN HOWRAH SCHEDULE B PROVISIONING OF RAILNET CONNECTION THROUGH NETWORKING EQUIPMENT SCHEDULE CRECONSTRUCTION IMPROVEMENT RENOVATION ALONG WITH UP GRADATION OF FACILITIES AT BOOKING OFFICES AT SIU NSF MUG SKG MTFA DMLE KJU AND TBAE STATIONS SCHEDULE D1 REPLACEMENT OF OVERAGED SCADA SYSTEM IN HOWRAH BARDDHMAN KATWA SECTION AS PER LATEST SPECIFICATION
BECIL/PROJ/BT/SDSTE/BO-RN/SCADA/IR-HWH/26-27/EOI~EWf55363b3f337fc9537aa6a8d
BECIL/PROJ/BT/SDSTE/BO-RN/SCADA/IR-HWH/26-27/EOI
Expression of Interest
Information Technology/Telecom
BECIL-NOIDA
₹17,700
₹4.0 L
2 Oct 2026
2 Oct 2026
7 Oct 2026
2 Oct 2026
7 Oct 2026
"Supply, Installation, testing and commissioning of 48 Fiber(SC/APCSC/ APC) FDMS including splicing of OFC and termination ofall fibres using pig tail cable ofstandard size ( All materialsincluding pig tails tobe supplied by the contractor, thisalso includes arrangement & fixingof suitable metal box fixable in wallfor spare OFC coil) as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs "
Supply and laying of single mode 12 fibre armoured OFC cable, as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Installation of 19"rack mouted 12 port Fiber management system and termination of OFC and Splicing of all the Fibers inside theTerminal Box with provision oftaking out OFC as required. Thisincludes supply of all Installation accessories including the pigtails with connector as per order ofpractice for installation andcommissioning of Optical FiberSystem as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
(a) Supply of UTP Cat-6 LSZH cable as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs (b) Laying of Power Cable/STP/UTP CAT-6/LS cable/fiber through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (the clamps and screws should be made of Stainless steel). All the fixing materials including Collar, bend junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe, HDPE Pipe etc. to the site.
Supply and fixing of 25mm PVC conduit pipe (medium grade ISI ) as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
(a) Supply of 24 port PoE managed Network Switch as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs (b) Installation of Network Switch as per site requirement
Supply and installation of SFP Module Specification as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of CAT6 Patch Cord as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
(a) Supply of 8 port PoE managed Network Switch with SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs (e) Installation of Network Switch as per site requirement
Supply and Installation of Wi-Fi Router, as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
(a) Supply and fixing of RJ45 Connector as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
(b) Supply & installation of RJ-45 dual faceplate input-output module as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
SITC of Non-Executive open standard SIP Phone as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee.
Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed.
Cuting of the Platform surface (Tile/Slab/Mastic Pad/Concreat) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" where possible.
Supply and installation of Wall mounted 19",9U Rack with fan and 6 no sockets and accessories. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of Wall mounted 19",6U Rack with fan and 6 no sockets and accessories.as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
(a) Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs- 2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs (b) Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of mono-mode armoured OFC cable
Laying of Power Cable/STP/UTP CAT-6/LS cable/fiber through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (the clamps and screws should be made of Stainless steel). All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe, HDPE Pipe etc. to the site.
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
Supply, Installation, Testing and Commissioning of Full HD Fixed Bullet type IP Colour Camera along with 128 GB or Higher SDCard, housing and mount and all accessories required forinstallation purposes per RDSOSpec No RDSO/SPN/TC/65/2021Version 6.0 with AmendmentNo. 3 or latest. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Supply, Installation, Testing andCommissioning of Full HD PTZ type IPColour Camera alongwith 128 GB orHigher SD Card,housing and mount and allaccessories required forinstallation purposes as perRDSO Spec NoRDSO/SPN/TC/65/2021 Version6.0 with Amendment No. 3 orlatest. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of Network Video Recorder with monitoring system "(a) Supply of 32 Channel Network Video Recorder with Cables Suitable for CCTV System (Accessories) As per annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs " "(b) Supply of Survelliance Hard Disk 8 TB as per Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs " "(c) Supply of 55 inch Video Display Unit as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs " "(d) Supply of HDMI CABLE(20,15,10,5,2 & 1 MTRS),1 SETMEANS 20,15,10,5,2 & 1MTRSLENGTH CABLE ONE NUMBEREACH.as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs " (e) Installation, testing & commissioning of all items mentioned in schedule above
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installtion of basic material to construct unit maintenance free earth "(a) Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL ,IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. © Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO " "(b) Installation of Unit Maintenance Free Earth as supplied in above item.It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. This also includes inter-connecting of nearby existing earthing to make equipotential Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee "
Supply and installation of Power Extension board As per annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of 1KVA Online UPS with half an hour backup.as per Annexure Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 5 lakhs
Schedule () B-Provisioning of Railnet connection through networking equipment
Supply and laying of single mode 12 fibre armoured OFC cable, as per AnnexureInspection: Consignee
Supply and installation 12 Fiber LIU/FDMS
Supply of UTP Cat-6 LSZH cable as per Annexure. INSPECTION CONSIGNEE.
Laying of Power Cable/STP/UTP CAT-6/LS cable/fiber through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (the clamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe, HDPE Pipe etc. to the site.
Supply & installation of RJ-45 dual faceplate input-output module(Asper Annexure) Make-MOLEX/DAX/D-LINK or similar.INSPECTION : CONSIGNEE."
Supply of 24 port PoE managed Network Switch with Gigabit SFP Port as per Annexure. INSPECTION : CONSIGNEE10/100/1000 Mbps with 2
Supply of 8 port PoE managed Network Switch with 10/100/1000 Mbpswith 2 Gigabit SFP Port as per AnnexureINSPECTION :CONSIGNEE.
Installation of Managed Network Switch as per site requirement
Supply of SFP Module Specification as per Annexure. INSPECTION : CONSIGNEE.
Supply of dual band Gigabit wi-fi acess point as per Annexure Inspection: Consignee
Installation of dual band Gigabit wi-fi acess point as per site requirement
Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cord as per Annexure. INSPECTION CONSIGNEE.
Supply of RJ45 Connector INSPECTION : CONSIGNEE.
Supply and installation of Wall mounted 19",6U Rack with fan and 6 no sockets and accessories. Make: HCL, VALRACK & APW or Similar. INSPECTION : CONSIGNEE.
Cuting of the Platform surface (Tile/Slab/Mastic Pad/Concreat) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" where possible
Supply of 25mm PVC conduit pipe (medium grade ISI )
Supply, Fixing and wiring of 20 Pairs Krone type D.P. boxas per annexureInspection: Consignee
Disconnection & Reconnection of All Telecom Equipments like Cables/Joints/terminationand other telecom works. This includes Supply of Labours(Helper/Assistant) of 5 Nos per Man Day to assist Telecoml Supervisor / Officerduring Field Work & Other S&T work.
Supply of AC Power extension Socket Complete set
Schedule () C-Reconstruction/Improvement/ Renovation along with up-gradation of facilities at Booking offices at SIU,NSF,MUG,SKG,MTFA,DMLE,KJU & TBAE stationsSCHEDULE ( MTFA, DMLE, KJU, TBAE)
Supply and laying of UTP Cat-6 LSZH cable"(a) Supply of UTP Cat-6 LSZH cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of 25mm PVC conduit pipe (medium grade ISI ) as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c ) Laying of CAT-6 through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and laying of copper power cable"(a ) Supply of copper power cable 2.5 S.Q.mm 3 core. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of Power Cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and Laying of LS cable"(a) Supply of LS cable. 2 Core 1.5 Sq.mm Steel Wire Armoured screened copper cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b ) Laying of LS cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and laying of single mode 12 fibre armoured OFC cable, as pe AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs
Splicing /termination of OFC as per site requirement
Supplyof 12 core optical fibre FDMS/LIU as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Laying of HDPE pipe duct, 40/33 mm"(a) Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO.RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of HDPE pipe duct,40/33 mm in trenches and protective works including pulling of armoured OFC cable/Cables through duct in trenches and as advised by site engineer.Note:- (1) the contractor will take over the OFC cable from railway store to site of work duly checked the continuity of each fibre from end to end . (2) before & after laying of optical fibre cable through duct, continuity test from end to end of each fibre to be made by the contractor to ensure availability of all fibre duly certified by the site engineer if any."
Supply and installation of Wall mounted 19",9U Steel Rack in with fan and 6 no sockets and accessories as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Shifting and Reinstallation of Camera with Housing as per site requirement
Supply and installation of 2 Mbps SHDSL Modem as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of 4 Port Router as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Installation of Media converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply & installation of E1 to Ethernet converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of 24 port PoE managed Network Switch with SFP module and patch cord"(a) Supply of 24 port PoE managed Network Switch with 10/100/1000 Mbps with Gigabit SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of SFP Module Specification as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c) Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant than 5 lakhs ""(d) Supply of CAT6 Patch Cord policy(ii) Consignee if value of whole item in work less as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(e) Installation of 8 Port Network Switch as per site requirement
Supply and installation of 8 port PoE managed Network Switch with SFP module and patch cord"(a) Supply of 8 port PoE managed Network Switch with 10/100/1000 Mbps with Gigabit SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of SFP Module Specification as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c) Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(d) Supply of CAT6 Patch Cord as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(e) Installation of 8 Port Network Switch as per site requirement
Supply and transportation of RJ45 Connector as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Installation of Single Face RJ - 11 Input/Output Box. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply & installation of RJ-45 dual faceplate input-output module as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee.
Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable."(a) Boring up to the length of 150 meters. Preparation of site forHorizontal Boring shall be carried out in presence ofRailway Representative.
Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable."(b) Laying of 6 quad/Signalling cable/Power Cable with nylonrope through HDPE pipe and back filling of boringpit.
Digging of trench 1.2 Mtrs. deep from rail flange/ road leveland 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing ofDWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe coveredseparately). The ballast disturbed be screened and dressed as required by Engineer-incharge or his representatives androad tarred immediately. For track crossing, RDSO sketch No.SDO/CABLE LAYING/009 or latest and for Road Crossing,RDSO sketch No. SDO/CABLE LAYING/010 or latest are tobe followed.
Cuting of he Platform surface (Tile/Slab/Mastic Pad/Concreat) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" where possible.
Supply, Installation and commissining of 230V AC/3 KVA UPS (hot stand by) system isolation transformer at input, SMF battery, battery rack as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]
Supply and installation of basic material to construct unit maintenance free earth"(a) Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL ,IEC to be produced. It consist of following:(a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no.(b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos.© Copper strip of 150x25x6 mm, to terminate earth rod = 1 no.(d) Copper strip of 300x25x6 mm (MEEB) = 1 no.(e) Copper strip of 150x25x6mm (SEEB) = 1 no.(ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter)(iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter )(iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB(v) Supply of copper lug sleeve for 3/16 cableInspection: RDSO""(b) Installation of Unit Maintenance Free Earth as supplied in above item.It includes( i ) Digging the earth to the required depth.(ii) Insertion of electrode.(iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor.(v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness.Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest.Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room.GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. This also includes inter-connecting of nearby existing earthing to make equipotential Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee"
Supply and installation of 5 way AC Power extension Socket Complete set as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply, Fixing and wiring of 20 Pairs Krone type D.P. boxas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply, Installation Commissioning of 350 Watt Amplifier,as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
"Supply and installation of customised amplifier rack for holding amplifier,as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
"Disconnection & Reconnection of All Telecom Equipments like Cables/Joints/terminationand other telecom works. This includes Supply of Labours(Helper/Assistant) of 5 Nos per Man Day to assist Telecoml Supervisor / Officerduring Field Work & Other S&T work."
Schedule () C1-Reconstruction/Improvement/ Renovation along with up-gradation of facilities at Booking offices at SIU,NSF,MUG,SKG,MTFA,DMLE,KJU & TBAE stationsSCHEDULE (SKG)
Supply and laying of UTP Cat-6 LSZH cable"(a) Supply of UTP Cat-6 LSZH cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of 25mm PVC conduit pipe (medium grade ISI ) as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c ) Laying of CAT-6 through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and laying of copper power cable"(a ) Supply of RDSO/RITES if value of item in work more than 5 lakhscopper power cable 2.5 S.Q.mm 3 core. as per AnnexureInspection: (i) or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of Power Cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and Laying of LS cable"(a) Supply of LS cable. 2 Core 1.5 Sq.mm Steel Wire Armoured screened copper cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b ) Laying of LS cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Splicing /termination of OFC as per site requirement
Supply and installation of of 12 core optical fibre FDMS/LIU as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Laying of HDPE pipe duct, 40/33 mm"(a) permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO.Supply of 40 mm dia RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of armoured OFC cable/Cables through duct in trenches and as advised by site engineer.Note:- (1) the contractor will take over the OFC cable from railway store to site of work duly checked the continuity of each fibre from end to end . (2) before & after laying of optical fibre cable through duct, continuity test from end to end of each fibre to be made by the contractor to ensure availability of all fibre duly certified by the site engineer if any."
Supply and installation of Wall mounted 19",9U Steel Rack as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Shifting and Reinstallation of Camera with Housing as per site requirement
Supply and installation of 2 Mbps SHDSL Modem as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of 4 Port Router as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Installation of Media converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply & installation of E1 to Ethernet converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of 24 port PoE managed Network Switch with SFP module and patch cord"(a) Supply of 24 port PoE managed Network Switch with 10/100/1000 Mbps with Gigabit SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of SFP Module Specification as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c) Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(d) Supply of CAT6 Patch Cord as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(e) Installation of 8 Port Network Switch as per site requirement
Supply and installation of 8 port PoE managed Network Switch with SFP module and patch cord"(a) Supply of 8 port PoE managed Network Switch with 10/100/1000 Mbps with Gigabit SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of SFP Module Specification as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c) Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(d) Supply of CAT6 Patch Cord as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(e) Installation of 8 Port Network Switch as per site requirement
Supply and transportation of RJ45 Connector as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Installation of Single Face RJ - 11 Input/Output Box. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply & installation of RJ-45 dual faceplate input-output module as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee.
Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable."Boring up to the length of 150 meters. Preparation of site forHorizontal Boring shall be carried out in presence ofRailway Representative.
Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable."Laying of 6 quad/Signalling cable/Power Cable with nylonrope through 110 mm HDPE pipe and back filling of boringpit.
Digging of trench 1.2 Mtrs. deep from rail flange/ road leveland 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing ofDWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe coveredseparately). The ballast disturbed be screened and dressed as required by Engineer-incharge or his representatives androad tarred immediately. For track crossing, RDSO sketch No.SDO/CABLE LAYING/009 or latest and for Road Crossing,RDSO sketch No. SDO/CABLE LAYING/010 or latest are tobe followed.
Cuting of he Platform surface (Tile/Slab/Mastic Pad/Concreat) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" where possible.
Supply, Installation and commissining of 230V AC/3 KVA UPS (hot stand by) system isolation transformer at input, SMF battery, battery rack as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]
Supply and installation of basic material to construct unit maintenance free earth"(a) Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL ,IEC to be produced. It consist of following:(a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no.(b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos.© Copper strip of 150x25x6 mm, to terminate earth rod = 1 no.(d) Copper strip of 300x25x6 mm (MEEB) = 1 no.(e) Copper strip of 150x25x6mm (SEEB) = 1 no.(ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter)(iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter )(iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB(v) Supply of copper lug sleeve for 3/16 cableInspection: RDSO""(b) Installation of Unit Maintenance Free Earth as supplied in above item.It includes( i ) Digging the earth to the required depth.(ii) Insertion of electrode.(iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor.(v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness.Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest.Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room.GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. This also includes inter-connecting of nearby existing earthing to make equipotential Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee"
Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No
Supply of 5 way AC Power extension Socket Complete set as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply, Fixing and wiring of 20 Pairs Krone type D.P. box as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
"Disconnection & Reconnection of All Telecom Equipments like Cables/Joints/terminationand other telecom works. This includes Supply of Labours(Helper/Assistant) of 5 Nos per Man Day to assist Telecoml Supervisor / Officerduring Field Work & Other S&T work."
Schedule () C2-Reconstruction/Improvement/ Renovation along with up-gradation of facilities at Booking offices at SIU,NSF,MUG,SKG,MTFA,DMLE,KJU & TBAE facilities at Booking offices at SIU,NSF,MUG,SKG,MTFA,DMLE,KJU & TBAE stationsSCHEDULE (SIU, NSF, MUG)
Supply and laying of UTP Cat-6 LSZH cable"(a) Supply of UTP Cat-6 LSZH cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of 25mm PVC conduit pipe (medium grade ISI ) as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c ) Laying of CAT-6 through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and laying of copper power cable"(a ) Supply of copper power cable 2.5 S.Q.mm 3 core. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of Power Cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and Laying of LS cable"(a) Supply of LS cable. 2 Core 1.5 Sq.mm Steel Wire Armoured screened copper cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b ) Laying of LS cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Splicing /termination of OFC as per site requirement
"Supplyof 12 core optical fibre FDMS/LIU as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
Supply and Laying of HDPE pipe duct, 40/33 mm"(a) Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of armoured OFC cable/Cables through duct in trenches and as advised by site engineer.Note:- (1) the contractor will take over the OFC cable from railway store to site of work duly checked the continuity of each fibre from end to end . (2) before & after laying of optical fibre cable through duct, continuity test from end to end of each fibre to be made by the contractor to ensure availability of all fibre duly certified by the site engineer if any."
"Supply and installation of Wall mounted 19"",9U Steel Rack as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
Shifting and Reinstallation of Camera with Housing as per site requirement
"Supply and installation of 2 Mbps SHDSL Modem as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
Supply and installation of 4 Port Router as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply and Installation of Media converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
"Supply & installation of E1 to Ethernet converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
Supply and installation of 24 port PoE managed Network Switch with SFP module and patch cord"(a) Supply of 24 port PoE managed Network Switch with 10/100/1000 Mbps with Gigabit SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of SFP Module Specification as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c) Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(d) Supply of CAT6 Patch Cord as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(e) Installation of 8 Port Network Switch as per site requirement
Supply and installation of 8 port PoE managed Network Switch with SFP module and patch cord"(a) Supply of 8 port PoE managed Network Switch with 10/100/1000 Mbps with Gigabit SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of SFP Module Specification as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c) Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(d) Supply of CAT6 Patch Cord as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(e) Installation of 8 Port Network Switch as per site requirement
"Supply and transportation of RJ45 Connector as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
Supply and Installation of Single Face RJ - 11 Input/Output Box. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Supply & installation of RJ-45 dual faceplate input-output module as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
"Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee."
Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable.""Boring up to the length of 150 meters. Preparation of site forHorizontal Boring shall be carried out in presence ofRailway Representative."
Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable.""Laying of 6 quad/Signalling cable/Power Cable with nylonrope through 110 mm HDPE pipe and back filling of boringpit."
Digging of trench 1.2 Mtrs. deep from rail flange/ road leveland 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing ofDWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe coveredseparately). The ballast disturbed be screened and dressed as required by Engineer-incharge or his representatives androad tarred immediately. For track crossing, RDSO sketch No.SDO/CABLE LAYING/009 or latest and for Road Crossing,RDSO sketch No. SDO/CABLE LAYING/010 or latest are tobe followed."
Cuting of he Platform surface (Tile/Slab/Mastic Pad/Concreat) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" where possible.
"Supply, Installation and commissining of 230V AC/3 KVA UPS (hot stand by) system isolation transformer at input, SMF battery, battery rack as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]
Supply and installation of basic material to construct unit maintenance free earth"(a) Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL ,IEC to be produced. It consist of following:(a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no.(b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos.© Copper strip of 150x25x6 mm, to terminate earth rod = 1 no.(d) Copper strip of 300x25x6 mm (MEEB) = 1 no.(e) Copper strip of 150x25x6mm (SEEB) = 1 no.(ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter)(iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter )(iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB(v) Supply of copper lug sleeve for 3/16 cableInspection: RDSO""(b) Installation of Unit Maintenance Free Earth as supplied in above item.It includes( i ) Digging the earth to the required depth.(ii) Insertion of electrode.(iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor.(v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness.Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest.Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room.GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. This also includes inter-connecting of nearby existing earthing to make equipotentialNote: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee"
Supply of 5 way AC Power extension Socket Complete set as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "
Supply, Fixing and wiring of 20 Pairs Krone type D.P. box as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs
Disconnection & Reconnection of All Telecom Equipments like Cables/Joints/terminationand other telecom works. This includes Supply of Labours(Helper/Assistant) of 5 Nos per Man Day to assist Telecoml Supervisor / Officerduring Field Work & Other S&T work
Schedule () D1-Replacement of overaged SCADA system in Howrah-Barddhman- Katwa section as per latest specification
Supply, Installation, testing andcommissioning of 48 Fiber(SC/APCSC/ APC) FDMS including splicing of OFC and termination ofall fibres using pig tail cable ofstandard size ( All materialsincluding pig tails tobe supplied by the contractor, thisalso includes arrangement & fixingof suitable metal box fixable in wallfor spare OFC coil) Insp. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs"
Supply of STP CAT-6 Cable (305 meter Box). as per annexure INSPECTION : CONSIGNEE.
Supply of Polythene Insulated Polythene Sheathed Armoured Jelly Filled Telephone Cable with Poly-Almunium moisture barrier 0.63 mm dia. 10 pair. INSPECTION : CONSIGNEE.
Supply and installation of thermo shrink jointing kit for 10 pair/20 pair PIJF cable(0.63 mm dia) for normal & straight through joint as per RDSO/SPN/TC/57/2006 Rev.0 Amdt.-1 Or latest INSPECTION : CONSIGNEE.
Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC- 77/2012 revision 3 With latest Amdt.Inspection: By RDSO
Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit.After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost."
"Supply and fixing of 20 Pair CT box(Cable termination box Spec. No. IRS-TC/18-75 or latest. )INSPECTION : CONSIGNEE."
Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc. under supervision and instructions issued by Engr. In-charge of the work."
Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with rope) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy"
Laying of HDPE pipe duct, in trenches and its protective works as per direction of site engineer.
Pulling and Blowing of 48F OFC in already laid HDPE duct in trench as per site requirement. Insp. By Consignee
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. (b- )Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee."
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.Inspection: Consignee"
Supply of half size apparatus case (As per asper RDSO drawing No. RDSO/S-11507). Thisincludes supply of location box (GKP type) with 'E'type lock & key, fitted on location door on bothside, E Type lock (ward No will be specified byEngineer-in Charge) as per RDSO Drg. No. SA3376 and Key to Drg. No. 3377 as per RDSOdrawing No. RDSO/S-11507.Inspection: (i) RITES if value of item in work morethan 5 lakhs or as per extant policy(ii) Consignee subject to procurement fromRECOMMENDED LIST OF FIRMS FORMECHANICAL SIGNALLING ITEMS if value ofwhole item in work less than 5 lakhs or as perextant policy.
Casting, concreting and curing of concretefoundation (in ratio 1:3:6), erection and installation of half size apparatus case (GKP type) Apparatus Case as per DRG.NO. RE/S&T/SIG/TENDER/SK/8/85 with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: -bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes topainted with anti-corrosive paints as per IS: -9862-1981, one and half feet from the bottom, onall surfaces-both inside and outside.Inspection: Consignee"
Supply of hard wood shelves thickness 25 mm for keeping equipment's and batteries in the location box (FULL or HALF GKP /other type) with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. Inspection: -Consignee (notebalance quantity may be taken from Rly store ifavailable).450 x 400 x 25 MM for half size location box. Inspection: Consignee
Excavation of Track Crossing, road Crossing (Earth Work and Re-instatement of Track after laying of GI pipe) as per direction of site supervisor. ( CABLE WILL BE SUPPLIED BY THE RAILWAY).
Supply of Power Cable 3 X 4 SQ.MM unarmoured as per IS-694 .PVC insulated flexible 3 core x 4 sq. mm multistrand power cable shall conform to specification no IS694:1990 reaffirmed 1995 or latest of reputed brand. Inspection: Consignee"
Supply of 5/6 Pair 0.5 mm dia PVC Cable TEC's specification No. GR/WIR-06/03 March 2002 with latest ammendment if any. Make Finolex or similar. INSPECTION CONSIGNEE.
Laying of Power Cable/STP/UTP CAT-6/LS cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly. Representative, including any fixing of cables/PVC pipe/PVC Casing on wall/shed with suitable clamps (the clamps and screws should be made of Stainless steel) . All the fixing materials including Collar, bend, junction etc. shall be supplied by the contractor. This also includes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site."
Supply and installation of Wall mounted 19",4U Rack with fan and 6 no sockets and accessories. Make: HCL, VALRACK & APW or Similar. INSPECTION : CONSIGNEE..
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]
Supply of 1 x 16 Sq.mm. (Red/Black/Green) multistrand copper power wire as per IS: 694:2010 orlatest, 126 conductor each dia 0.40mm +/- 0.01 withinsulation thickness of 1.0 mm and nominalconductor resistance of 1.21 ohms/km and testparameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest. Color of the wire which isrequired will be specified by the Engineer incharge.Inspection: Consignee subject toprocurement from RDSO approved vendors if valueof whole item in work less than 5 lakhs as per extantinstructions by Railway Board."
Supply & laying of 25x3 mm pure electrolytic copper tapethrough suitable CLASS-'B' GI pipe for loop Earthing andbonding as per site requirement. Supply material inspectionby consignee."
Supply of Power Extension box, as per annexure INSPECTION : CONSIGNEE.
Supply of RJ45 Connector (1 box of 100 nos) Specification as per Annexure INSPECTION : CONSIGNEE.
Supply & installation of E1 to Ethernet converter as per Annexure. INSPECTION : CONSIGNEE."
Supply and installation of 2 Mbps SHDSL Modem as per Annexure . INSPECTION : CONSIGNEE.
Supply and installation of 4 port Lan extender as per annexure INSPECTION : CONSIGNEE.
"Disconnection & Reconnection of All Telecom Equipments like ables/Joints/terminationand other telecom works. This includes Supply of Labours(Helper/Assistant) of 5 Nos per Man Day to assist Telecoml Supervisor / Officerduring Field Work & Other S&T work.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
EOI3 SDSTE.pdf
Tender Document
Price Bid.xlsx
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .