| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.9 L+₹1.7 L (5.59%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | Santhi Enterprises L1 | M/s.TIRUPATI BUILDERS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators,partition with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing,glazing clips, rubber neoprene packing, anodised aluminum snap beading screws etc fixing items , includng taking down complete existing partition etc. complete all as specified and as directed. | 664 | Sqm | 475 ₹3,15,400 Lowest | 580 ₹3,85,120 |
| 2.00 | Supply an fix 5 (+/-0.5) mm thick sheet glass ordinary quality and glazing sheet glass is ground or obscured or frosted, on one side with rubber beading, fixing in aluminium frame as in partition /door as directed by Engineer in charge exc. 0.5 Sqm each pane-complete all as specified and directed. | 35 | Sqm | 725 ₹25,375 Lowest | 900 ₹31,500 |
| 3.00 | Supply and fix 12 mm thick prelaminated particle board Interior grade pre laminated both sides with decorative choice laminations fixed in partition or door ,colour as directed on aluminium frame work all as specified and directed. | 35 | Sqm | 635 ₹22,225 Lowest | 1,500 ₹52,500 |
| 4.00 | Removing existing man hole cover and cleaning of existing sewage line of any dia including manholes of any depth and size by mechanical Jet/rodding machine with sufficent pressure and rodding to clear the line without damaging the pipes by removing the old sewage materials sticked to internal periphery of the pipe completely and collecting sludge in closed filth carts and depositing all as directed by engr-in-charge including sprinkling of antibiotic/disinfectant powder on affected area and refixing the manhole cover as before all as directed. | 220 | RM | 22 ₹4,840 Lowest | 80 ₹17,600 |
| 5.00 | Clearing blockages and removal of sludge/mud and other accumulated materials and cleaning gully traps/nahani traps, Bends with 100/75mm dia pipes by opening doors of bends and refixing the same and manhole chambers of any description and size. Including disposal sludge materials in closed filth carts and depositing all as directed. | 60 | Each | 90 ₹5,400 Lowest | 100 ₹6,000 |
| 6.00 | Material and labour for Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 394.95 | Cum | 160 ₹63,192 | 150 ₹59,242.5 Lowest |
| 7.00 | Material and labour for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. with soil complete all as specified and as directed. | 156.94 | Cum | 50 ₹7,847 Lowest | 60 ₹9,416.4 |
| 8.00 | Material and labour for removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed | 12.86 | Cum | 90 ₹1,157.4 | 80 ₹1,028.8 Lowest |
| 9.00 | Material and labour for reinforced cement concrete pipes class NP-2 laid in jointed complete with collers bore of pipe 150mm Complete all as specified and directed.
Make: Hindustan / Universal or equvilant confirming to IS. | 5 | RM | 384 ₹1,920 Lowest | 600 ₹3,000 |
| 10.00 | Material and labour for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate, bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in bore of pipe 150mm.Complete all as specified and directed. | 5 | RM | 248 ₹1,240 Lowest | 350 ₹1,750 |
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
17 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
INTEGRATED COMPREHENSIVE MAINTENANCE WORKS OF BR AND EM WORK AT RCMA NASHIK GE AF OJHAR
2025_MES_741577_1
80721/E8
Open Tender
Civil Works
Item Rate
GE AF OJHAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF OJHAR
₹60,000
Yes
3 Mar 2026
26 Nov 2025
19 Dec 2025
26 Nov 2025
17 Dec 2025
10 Dec 2025
Amount
Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators,partition with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing,glazing clips, rubber neoprene packing, anodised aluminum snap beading screws etc fixing items , includng taking down complete existing partition etc. complete all as specified and as directed.
Supply an fix 5 (+/-0.5) mm thick sheet glass ordinary quality and glazing sheet glass is ground or obscured or frosted, on one side with rubber beading, fixing in aluminium frame as in partition /door as directed by Engineer in charge exc. 0.5 Sqm each pane-complete all as specified and directed.
Supply and fix 12 mm thick prelaminated particle board Interior grade pre laminated both sides with decorative choice laminations fixed in partition or door ,colour as directed on aluminium frame work all as specified and directed.
Removing existing man hole cover and cleaning of existing sewage line of any dia including manholes of any depth and size by mechanical Jet/rodding machine with sufficent pressure and rodding to clear the line without damaging the pipes by removing the old sewage materials sticked to internal periphery of the pipe completely and collecting sludge in closed filth carts and depositing all as directed by engr-in-charge including sprinkling of antibiotic/disinfectant powder on affected area and refixing the manhole cover as before all as directed.
Clearing blockages and removal of sludge/mud and other accumulated materials and cleaning gully traps/nahani traps, Bends with 100/75mm dia pipes by opening doors of bends and refixing the same and manhole chambers of any description and size. Including disposal sludge materials in closed filth carts and depositing all as directed.
Material and labour for Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Material and labour for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. with soil complete all as specified and as directed.
Material and labour for removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
Material and labour for reinforced cement concrete pipes class NP-2 laid in jointed complete with collers bore of pipe 150mm Complete all as specified and directed. Make: Hindustan / Universal or equvilant confirming to IS.
Material and labour for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate, bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in bore of pipe 150mm.Complete all as specified and directed.
Material and labour for Brick work with flyash' bricks, straight or curved on plan exc 6m mean radius, built in CM 1: 4 as in Manholes/ similar work including pointing flush the external face of the brick work as the work proceeds all as specified and directed. Note:-Rate is inclusive of Demolition of brickwork built in cement mortar including all quoins, arches, pillars, but excluding pre-cast concrete articles, Complete all as specified and directed.
Labour only Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in. Note:-Rate is inclusive of Demolition of brickwork built in cement mortar including all quoins, arches, pillars, but excluding pre-cast concrete articles, Complete all as specified and directed.
Material and labour for 15 mm thick cement plaster in CM 1:4 on brick surface finished even and smooth without using extra cement including 2% Water Proofing Compound as per weight of cement, Complete all as specified and directed.
Material and labour for complete removal of existing treatment of wall / ceiling / chajja by scrapping using Pressure water lite P-03 for pressurised removal by water jet having flow rate of 600L/h or with mechanical trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. for internal painting or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete by skilled labour complete all as directed. Note : After Completion of Removal existing surface Approved of Engr -in- charge and GE shall be Taken before appling further finshing .
Material and labour for preparation of old/ untreated plastered surfaces of walls/ceiling and applying two coats of oil bound distemper over and including a coat of cement base primer of same manufacturer over and including sand papering 2 mm thick wall care putty in two layers as per manufacturer's instructions complete all as specified and directed. Note : (i) Painting shall be done using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper/ primer should be able to spray in hard to reach areas and penetration of distemper on the surface.
Material and labour for preparation of old/ untreated plastered surfaces of walls/ceiling/chajja and applying two coats of weather proof exterior emulsion paint over and including a coat of priming coat of exterior cement base primer as per manufacturer's instruction complete all as specified and directed. Note : (i) The paining shall be done with fully automatic airless spray machine with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, by allowing 6-8 hrs to dry the surface for painting of subsequent coats of paint. (ii) Rate quoted shall be deemed to be included for scaffolding up to 15 mtr height building.
Material and labour for single coat of synthetic enamel paint over old wood or wooden based surface exc. 10cm width or girth including preparation of old or previously treated surfaces.compete all as specified as directed.
Material and labour for preparation of old painted steel surfaces of any description exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparing old steel surfaces of any description width or girth exc 10 cm, applying single coats of Aluminium paint over a coat of red oxide, zinc chrome all as specified and directed.
Demolition of cement concrete of any description and in any position complete all as specified and as directed.
Material and labour for 25mm thick plain cement concrete type B0 using (12.5mm graded aggregate) as in sub base complete all as specified and as directed.
Material and labour for Non-Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match on 15 mm thick screed bed of 1:6 cement morter all as specified and directed.
Material and labour for glazed vitrified tiles (GVT) dark shade 8-10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed bed 1:6 cement mortar complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises if backing is dismanteles shall be made good by the contractor before bedding layer is laid.
Material and labour for Glazed Vitrified tiles (GVT) dark on vertical wall surfaces shade 8-9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.135 sqm but not exceeding 1 sqm . set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm sereed bed 1:4 cement mortar complete all as specified and directed.
Taking down carefully existing bitumen tarfelt including plastering upto 15mm thick cleaning the surface and make free of dirt. foreign particles, laitance followed by grinding all protrusions to make surface modulated and removing all foreign materials / Bitumenous primer completely cleaning and washing the existing surface of roof/slab, terraces including flashings and junctions of Parapets/Curb walls etc and as directed. Note: (i) Contractor will not thrown the debris and taking down material from roof will make suitable arrangement to get down the material from roof. (ii) If taking down of plaster is exceeding 15mm than PCC and plaster both shall be measured under ser item No 20 below (iv) Removing of the rubbish to a distance outside MoD land at own arrangement of Contractor.
Material and labour for cleaning the old roof surface by wire brushes, brooming, removing dust from roof and providing Plain Cement concrete (PCC) 1:2:4, type B-0 (using 12.5mm graded stone aggregate) as in roof padding and finishing the surface fair & even and mixed with water proofing compound (WPC shall be measured and paid separately) as per manufacture's instructions finished even & fair complete all as specified and directed Note : PCC shall be laid in slope and thickness shall be average(minimum average thickness 25mm or as per site requirement for maintaining the slope) as per site including filling in depression by providing concrete bench marks for maintaining th perfect slope to drain out the rain water as directed by Engr-in-Charge. No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof Manually/ mechanically to achieve the proper strength and workmanship of concrete mixing shall be done mechanically
Material and labour for rendering 10mm thick in CM 1:3 on concrete surfaces mixed with water proofing compound @0.12 ltr per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement. Note:- (Supply only water proofing compound shall be measured and paid separately). Complete all as specified and directed.
Material and labour for providing cement slurry @3Kg per sqm on existing roof surface before laying PCC/ Plaster.
Supply only liquid water proofing compound
Material and labour for cleaning the newly plastered surfaces throughly with wire brushes and providing water proofing treatment all as given here in after (a) Bituminous primer @ 0 3lit per Sqm conforming to IS-3384-1986 (b) 3 mm thick APP polymer modified moply FP of M/S TEXSA Ltd or M/S STP Ltd or ASIAN PAINTS of Hydrostop Tiki Dan of M/s Tikki tar Ltd with minimum wt 3.0 Kg per square metre membrane (one layer) laid by torch application method. (c) Applying two coat of bituminous based aluminium paint @ 0.20 Kg in two coats (total in two coats) per square metre over membrane. Complete all as specified and directed by Engineer-in- charge. (d) The overlaps of APP shall be SSR part 1 and APP shall be laid by expert/ skilled workers only, bitumen based aluminious paint applied by brushes only.
Material and labour for repairing of existing modular kitchen (n exc 2.5 sqm area) including taking down & refixing at the same location cabinet, shutters & SS Rack and repairing with required material etc.complete. (i.e. ss lock, hinge, knobs, screw, washers, telescopic channels etc.)
Labour only for opening of air locks in toilets /baths and kitchen water pipe line but excluding fittings complete all as specified.complete all as specified and as directed.
Material and labour for easing of window shutters of any type , kitchen cupboards shutters , show case shutter , drawers including fixing of screws for easy closing /opening tightning of piano hinges or changing the position of hinges adjustment of adjusting of handles, knobs with new screw etc including other small adjustments including repair/ replacement of CP/MS powder coated sliding channels of standrad section by complete all as specified and directed.
Demolition of reinforcement cement Concrete in slab, kitchen platform and other similar suspended work pavings n exc 15 cm thickness.
Material and labour for 25 mm thick Cement Concrete type B 1 (1:2:4) using 20 mm graded stone aggregate as in sub bases, sub floors . Complete all as specified and as directed.
Material and labour for fancy type Stainless Steel handles 75 mm high of kitchen shutter /CB shutter, complete all as specified and directed.
Ditto as per item No. 37, but 100 mm high, all as specified and directed.
Material and labour for fancy type CB knobs of kitchen /drawer shutter as approved by Engr in charge etc complete all as specified and directed.
Material and labour for blind shutter hinge for door shutters of CB and kitchen shutters of SS ISI mark and complete all as specified and directed.
Material and labour for magnetic door lock for door shutters of CB and kitchen shutters of SS ISI mark and complete all as specified and directed.
Supplya and fix Mirror with plastic cabinet of size 550mmx400mmx75mm single door as per approved and complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and complete all as specified and directed.
Material and labour for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Supply and fix for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, MS Plates and welding Connection, cleats etcFe 410-W (GdeE- 250) quality A, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 Sqm each , including forming jambs compete all as specified as directed.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame) compete all as specified as directed and Rate including forming James.
Material and labour for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.
Material and labour for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.
Material and labour for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant, complete all as specified and directed.
Supply and fix 100 mm Butt hinges, Stainless Steel, hinge pin, as approved as per sample complete all as specified as directed.
Supply and fix Stainless steel Tower Bolt of size 150mm long 10mm Dia bolt, Plate 150X40X2mm thick with stricker plate knob & screw of approved quality complete all as specified and as directed.
Supply and fix Stainless steel Handle of size 150mm long with stricker plate knob & screw of approved quality complete all as specified and as directed.
Supply and fix 300 mm long and fancy type Stainless Steel, sliding door bolt staple (bolt type) and fixing bolt with rolled or drawn SS bolts and fixed complete all as specified as directed.
Supply and fix Aluminium Die cast body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified as directed.
Supply and fix 140 mm cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft and loose soil
Material and labour for Cement concrete type D-2, 1:4:8 (40mm graded aggregate) in foundation, filling, Mass concrete all as specified and directed.
Material and labour for two coats of synthetic enamel paint on steel surfaces over one coat of red oxide or zinc chrome primer, of any description over 10cm width or girth including preparation of new or previously untreated surfaces of steel. complete all as specified as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out of the land of MoD äs specified and directed.
Material and labour Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering nexc 63, compete all as specified as directed
Material and labour Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface all as specified and directed.
Material and labour for 75mm thick Cement Concrete type D2 (1:4:8) using 40 mm graded stone aggregate as in sub base of floor, complete all as specified as directed.
Material and labour for 25mm thick Cement Concrete type B0 (1:2:4) using 40 mm graded stone aggregate as in sub base of floor, complete all as specified as directed.
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed. Note- applicable for BOQ item no 66 to 131 contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority to attend faults/defects/complains or refixing of old or new fitting / fixtures as provided by E/M Sub div for free fixing at site. In case if electrician fails to rectify the faults then recovery shall be recovered from contractor s any due payment(c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-/ complains/ day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note -1 above.
Material and labour for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with surface plate suitable for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed.
All as per item no 67, but for One 5 Amps socket point on same/below board with other switches, complete all as specified and as directed.
All as per item no 67, but for One 5amps switch socket point independent complete all as specified and as directed.
Material and labour for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with surface plate suitable for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed . Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed.
All as per item no 71, but for One 5 Amps socket point on same/below board with other switches, complete all as specified and as directed.
All as per item no 71, but for One 5amps switch socket point independent, complete all as specified and as directed.
Material and labour for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run consealed in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed . Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Material and labour for wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in PVC conduit / cassing capping complete all as directed.
Material and labour for wiring for circuit/ sub main wiring of 2x4 Sqmm + 1x4 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC conduit/ casing caping complete all as directed.
Material and labour for wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed.
Supply and fix in replacement Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush typein PVC box.Make: Anchor/Havells Rio.,Complete all as specified & as directed.
Supply and fix in replacement Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type in PVC Box Make : Anchor/Havells Rio.,Complete all as specified & as directed.
Supply and fix in replacement Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Make : AnchorHavells Rio.,Complete all as specified & as directed.
Supply and fix in replacement PVC rectangular board 100 mm x 100 mmx 50 mm deep. Make : Press Fit or equavelent ,Complete all as specified & as directed.
Supply and fix in replacement PVC rectangular board 175mm x 100mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed.
Supply and fix in replacement PVC rectangular board 200mmx150mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed.
General servicing/maintenance , repair Split AC capacity 1.5/2 Ton ,dismantling unserviceable part of unit including cleaning of air filter,display,PCB,de-dusting of complete(indoor/outdoor) unit ,washing condensor unit with suitable water sprey jet, checking electrical connection cleaning the unit with blower, descaling with non-corrsive acid on both side of coling oil identifying the fault / trouble in unit & their redressal /rewiring complete, greasing of movable parts for getting trouble free service & making Split AC serviceable complete all as specified and directed by Engineer-In-Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after. 2-the rate for gas charging including refregerent gas will be included in quoted rates for serviceing )
Supply and fix in replacement new sealed unit compressor 1.5 Ton split air conditioner Make: Kirloskar complete all as specified & as directed. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply and fix in replacement new sealed unit compressor 2.0 T for split air conditioner Make:Kirloskar complete all as specified & as directed. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply and fix in replacement new fan motor 1/3 Hp ,230 v for split AC Make AUE or equivalent all as specified and as directed.
Supply and fix in replacement running capacitor for split Air conditioner 1.5 T/2 T of capacity 36/45 mfd , 7 point ,440 VAC Make Epcos ,complete all as specified and as directed.
Supply and fix in replacement starting capacitor for split Air conditioner 1.5 T/2 T of capacity 80/100 mfd 440 VAC Make Epcos, complete all as specified and as directed.
Supply and fix in replacement Relay (8500-4) (Make Annapurna) suitable for Air Conditioner mentioned above, complete all as specified & as directed.
Supply and fix in replacement remote control switches 1.5 Ton to 2 Ton capacity split A/C of any make as existing sample complete all as specified & as directed.
Supply and fix in replacement blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR, complete all as specified & as directed.
All as per item no 92, but for 2 TR complete all as specified & as directed.
Supply and fix in replacement Bush with Blower shaft assy complete,1.5 Ton to 3 Ton capacity split A/C of make as existing sample ,complete all as specified & as directed.
Supply and fix in replacement Printed Circuit Board (PCB) For split A/C of make as existing sample ,complete all as specified & as directed.
Repairs to Circuit of existing Printed Circuit Board (PCB) in split type AC of any make, complete all as specified & as directed.
Supply and fix in replacement condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified.
Supply and fix in replacement copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8/1/4 inch copper tubing complete all as specified & as directed.
Fixing only of MCB and MCCB of any rating with the help of suitable size of nut bolt washer screw etc including all electrical connection connection as required at site. ( Note - Material /store will be issued under schedule be )
Fixing only of tube light , POP light, ceiling light, Focus light, Street light or any type of light to be fix on wall /ceilling with the help of suitable size of nut bolt washer etc including all electrical connection connection as required at site ( Note - Material /store will be issued under schedule be )
Supply and fix in replacements power contactor, ML-2 type Three pole, 440 volt , Auxilary coil voltage 230 Volt, Make- L&T/Legrand/Semiens
Supply and fix in replacement of Automatic street light control with infrared sensor based NATURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 5 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Neutral loss & Phase reverse incl Power contactors (3 nos of capacity 16 amps per phase each) and incoming (3 nos of capacity 20 amps each)- outgoing MCB(3 nos of capacity 20 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option).Model Swadeep- 02EC5kW3P-VMS or equivqlent in Schneider/Havells/Legrand
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable multistanded with aluminium multi stranded conductor 1100V grade 4 core cross sectional area 10 sqmm all as specified and directed.
All as per item No 103, but 4 core 16 Sqmm, complete all as specified and as directed.
All as per item No 103, but 3 1/2 core 70 Sqmm, complete all as specified and as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 38mm, complete all as specified and as directed.
Supply and fix in replacements LED street light fittings 60 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-421-60-57-SL-LM-NSG or equivalent in Havells/ Phillips.complete all as specified and directed.
Supply and fix in replacements power contactor, ML-3type Three pole, 440 volt , Auxilary coil voltage 230 Volt, Make- L&T/Legrand/Semiens, complete all as specified and directed.
Supply and fix in replacements Time digital switch with built in PCB for street light , Make L&T, type DIGICON or equivalent of GEC/ GIC/ Havells, complete all as specified and directed.
Supply & Fix in replacement Post top lantern decorative HERITAGE LED suitable 1X20 Watt retro LED with opel deffuser including LED 20 Watt of Make Crompton Cat Part No LPTH-20-CDL or equivalent in Havells/ Wipro.complete all as specified and directed.
Supply and fix in replacement of microprocessor based single phase, AC electronic tamper proof static energy meter LCD display Electronic KWH meter of capacity 5-30 Amp, 240 Volts, 50 HZ, accuracy class 1 , KWh compact meter with pilfer proof meter bo with sealing screw provision base mounting, projection mounted Cat no- SPPB1310000002OC00 of Make:- HPL / L&T and depositing old meter to the MES Store.
Material and labour for Cutting 450/300 mm size hole for exaust fan in existing wall and making good with plastering and matching colour, Plaster the cut edges and surrounding area to restore the wall surface and apply surface treatment and paint the patched area using match colour and texture to blend seamlessly with the existing wall. Note :- Remove all debris and clean the site after work.
Material and labour for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc complete all as specified and directed by Engineer-in-Charge for celing fan 1200 mm sweep
All as per item No 113, but for Exhaust fan 300/380 mm sweep
Material and labour for replacement of heating assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitable for 25 ltrs capacity geyser all as directed Make : Ditzs/ Racold/ Shakti/Spheroat.
All as per item No 115, but for 35/50 lts capacity
Supply and fix Power Board suitable for 50/35/25 Ltr Digital Square water heater /geyser as per sample Make : Jaquar or equilivalent
Supply and fix in replacement thermostat having range 0 to 100 C for geyser as original size of 25/35/50ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
Supply and fix in replacement heating element 2 KW with round or triangular base for 50 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
Supply and fix in replacement heating element 1.5 KW with round or triangular base for 35 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
Supply and fix in replacement lamp indicator with red colour 230 volts complete with fixing arrangement round or rectangular shape and size as per existing geyser suitable for Ditzs/ Racold/ Shakti/Spheroat Make.
Supply and fixing for Outdoor Floor Mounted BUS-Bar Box working on 440V 3-phase, 200 Amps, 50 Hz, AC self supported, front & rear openable, double door ,hinged type with locking arrangement & sloping top canopy ,suitable ventilation on both side, with wire mesh, IP52 protection with Dust & Vermin proof etc. fabricated out of 3.15 mm CRCA sheet duly powder coated mounted/fixed on 50*50*6 mm thick MS Angle duly painted with black enamel synthetic paint over one coat of red oxide zink chrome primer, duly grouted in PCC 1:3:6 Type C1 using for foundation complete all as directed. Make: L&T
Disconnecting all existing electric supply and taking down carefully ceiling fan 1200/1400 sweep , dismantlling blades, and repair the same by rewinding,replacement of bush/bearing and capacitor etc. Testing at MES store yard completer all as specified and as directed. Note -Cost for transportation from site to MES store yard & vice versa is deemeed to be included under the quoted rate.
Supply & fix in replacement PVC perplex cover glove type with Base plate /holder not less than 8 inch dia suitable for Post top lantern including one nos 7/9 watt LED lamp complete all as specified and directed. Make - Bajaj / Surya/*havells.
Supply and fix 40mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
Fixing only of street light , flood light, high bay light, high mast light, Focus light or any type of light to be fix on wall /pole/ hanger etc with the help of suitable size of nut bolt washer etc including all electrical connection connection as required at site ( Note - Material /store will be issued under schedule be )
Fixing only in replacement Miniature Circuit Breaker (MCB) / DBs, of any rating or any capacity.
Fixing only in replacement Switch/ scoket / Ceiling Rose/ Push Bell switch/ Bell/ Plug top /SS Combine/ Lamp Holder/ Fan Regulator and other connected items
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) including all earth work and PCC fondation as recommeded by OEM complete all as as directed.
Supply and fix MS Single arm bracket 1.50 mtr long 40/32 mm dia, fixing with suitable nut bolt and washer as described in OEM manual complete all as as directed.
Material and labour for Preparation of old painted surfaces of steel tublar poles LT 9.0 Mtr long & painting two coats of aluminium paint from top to bottom and painting with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, including existing cross arm/angle iron/clamps/brackets etc & marking of pole numbers in white on black background all as directed.
Note : The amount against Schedule of Credit on Page No. 46 shall be deducted from the total amount quoted against Sch 'A' while deriving lum Sum for Acceptance.
M/s.TIRUPATI BUILDERS (BID ID -3503908)
Bidder Name
Santhi Enterprises
M/s.TIRUPATI BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
BOQ_830398.xls
BOQ • 0.38 MB
PS80721.pdf
Tender Documents • 1.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .