| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.8 L+₹3.4 L (10.2%)Rejected-Finance 117 BHAISAHIYA TOLA GANESHGANJ MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | MIRZAPUR | UTTAR PRADESH | 231001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹38.4 L+₹5.0 L (14.9%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹41.2 L+₹7.7 L (23.1%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹43.5 L+₹10.1 L (30.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Restoration and management of LT Electricity Distribution Network at Old Cantt under GE (East) Prayagraj.
2024_MES_659635_1
8738/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Prayagraj
As Per NIT
6 documents required · 6 mandatory
₹500
GE (East) Prayagraj
₹98,000
Yes
4 Sept 2024
13 Jun 2024
18 Jul 2024
13 Jun 2024
11 Jul 2024
27 Jun 2024
13 Jun 2024 - 20 Jun 2024
Amount
Restringing & tightening of HT/LT overhead line ACSR conductor of any size , four to six wire, after opening from insulators,including replacement of all warnout jumper connections/nuts/bolts/washers and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
Restringing & tightening of GI earth continuity conductor of size 4mm dia HT over head line after opening from insulators,including replacement of all warnout jumper connections/nuts/bolts/washers and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
S&F synthetic line separators of LT OH lines, spiral type, horizontal configuration fixed at a point and suitable for three phase 5 wire LT lines complete all as specified and directed.
Supply only PVC Insulation tape colour code wise for insulation of cable joint complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 M deep below GL with top edge of plate not less than 1.5 M below GL) connected with GI strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, 40mm bore GI pipe light grade ISI marked for protection of GI strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1 chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade ISI marked for watering all as shown in electrical plate No. 3 of SSR Part-I and connected to earth test point including testing including dismantling of old ineffective earthing complete all as specified and directed. (Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth strip/wire and protection pipe upto 7.5 meter beyond the earth plates electrode).
S&F in repair earth continuity conductor or main earthing lead GI Strip of size 32mm x 6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
S&F in repair MCCB 4 pole 400 Amps cap 36 KA in suitable sheet metal enclosure incl connecting existing cable complete all as specified and directed.
S&F in repair MCCB 4 pole 250 Amps cap 36 KA in suitable sheet metal enclosure incl connecting existing cable complete all as specified and as directed.
M&L for painting of 9.00m steel pole with cross arms and clamp of any length and shape for overhead line/street light pole with one coat of aluminium paint including preparation of the existing surface including making number in a 15cm dia yellow circle and marking three black & two yellow bends with 10 cm width by fluorescent paint, from coping of pole to 1.5m height on pole including painting of coping with white wash with safety precaution and writing pole No. on pole & all disconnected electrical connections are connected and before painting shut down complete all as specified & directed.
S&F in repair stay assembly consisting of galvanised stay strand 7/2.24mm stay bow of 14 mm dia, stay rod 16 mm dia 180 cm long with loop insulators stay plate 230 mm x 230 mm x 6 mm with plain cement concrete foundation 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate ) complete with stay clamps, bolts and nuts complete all as specified and directed by Engineer -in - Charge including comprising of the following :- (a) Excavation and earth work for stay foundation in soft/loose soil,disposal of surplus soil to a distance not exceeding 50 metres & depositing where directed at a level not exceeding 1.5 mtr from the starting point as directed. (b) PCC 1:3:6, type C-2 ( using 40 mm graded crushed stone aggregate) as in embedding blocks
M&L for cutting triming and vending tree branches along over head lines and restringing the same after arranging electrical shut down including taking all precautions while working on lines contractor using own T&P by the contractor all as specified and directed. Note :- For taking shut down to excute the work min one skilled electrician and four mazdoor for 8 hrs/day shall be deployed on the work.
M&L for cleaning the area around all the sub station on weekely basis till the completion of work of electrical installation all by cutting/removing unwanted grass and grass bushes complete all as specified and directed. Note : Tools will be provided by Contractor.
M & L for serviceing of LT ACB unit by disconnecting, opening up the switch, cleaning thoroughly all the inner parts, lubricating the moving parts, replacing unserviceable spares as required for sooth operation of switch gear & testing complete all as directed. Note : (a) Spare parts shall be measured and paid separately as "S&F in repair" here in under. (b) Quoted rate are inclusive of cleaning material & lubricants.
Closing & opening release for Air Circuit Breakers
Under voltage release for Air Circuit Breakers
Micro switch for S/C trip indication release for Air Circuit Breakers
Special sliding contact for electrical position indication release for Air Circuit Breakers
Earth fault relay 3 phase 3 wire release for Air Circuit Breakers
Aux contact block 4 NO + 4 NC for Air Circuit Breakers
Fixed + moving sliding contact - 2 Nos for Air Circuit Breakers
Shutter assembly - 3 polefor Air Circuit Breakers
Arc chute - set of three for Air Circuit Breakers
Moving arcing contacts - 3 p for Air Circuit Breakers
Floating isolating contacts set of 3 for Air Circuit Breakers
CTs for Thermal over load relay - 3 Nos 630 A for Air Circuit Breakers
CTs for STU release -3 Nos 630 A for Air Circuit Breakers
Instantaneous U/V release for Air Circuit Breakers
S&F in repair cable looping box shock & rust proof having external dimension 230mm x 170mm x 105 mm including provision of 4 way heavy duty PVC insulated connector of suitable size and MCB of capacity 32-40 Amp complete all as specified & directed.
Supply and fixing in repair post top lantern fixed with warm white LED Bulb 12 W and retrofiting holder AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant rectifier complete all as specified and as directed.
S&F service cable 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular including taking down the old existing one complete all as required & directed.
S&F aluminium thimbles cables lugs for cables of size 16 to 50 sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F aluminium thimbles cables lugs for cables of size upto 70 sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F aluminium thimbles cables lugs for cables of size 95 sq.mm to 120 sq. mm including necessary crimping with crimping tool complete all as specified and directed
S&F aluminium thimbles cables lugs for cables of size 150 sqmm to 240 sqmm including necessary crimping with crimping tool complete all as specified and directed
Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 16 to 25 sqmm,Indoor/Outdoor type complete all as specified and as directed.
Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 35 Sqmm complete all as specified and as directed.
Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 50 sqmm,Indoor/Outdoor type complete all as specified and as directed.
Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 sqmm,Indoor/Outdoor type complete all as specified and as directed.
Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 to 240 sqmm,Indoor/Outdoor type complete all as specified and as directed.
S&F service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular including taking down the old existing one complete all as required & directed. all as required or directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including bottom surface to required level or slope for laying of cable etc complete all as specified and directed.
Returning filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches and consolidated complete all as specified and directed. NOTE : Punned thickness of 18 cm shall only be considered for payment.
M&L for sub class ‘B’ common burnt, bricks old size, designated '75', laid dry, flat with width equal to length of bricks as cover/laid over the cable to give mechanical protection to under ground cable complete all as specified and directed.
S&F for GI pipe 40 mm bore 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed.
S&F for GI pipe 50 mm bore 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed.
S&F for GI pipe 80 mm bore 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed.
Supplying ,laying, jointing, commissioning & testing for 10 Sqmm , 4 core XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking down existing cable complete all as specified & directed. NOTE : Manufacturer test certificate and purchase voucher of the cable shall be produced beofre claiming payment in RAR.
All as per item No.35 above but for 16 Sqmm , 4 core
All as per item No.35 above but for 25 Sqmm , 4 core
All as per item No.35 above but for 35 Sqmm , 3.5 core
All as per item No.35 above but for 50 Sqmm , 3.5 core
All as per item No.35 above but for 70 Sqmm , 3.5 core
All as per item No.35 above but for 95 Sqmm , 3.5 core
All as per item No.35 above but for 120 Sqmm , 3.5 core
All as per item No.35 above but for 150 Sqmm , 3.5 core
All as per item No.35 above but for 185 Sqmm , 3.5 core
All as per item No.35 above but for 240 Sqmm , 3.5 core
S&F of steel tubular pole 410-SP 31(9.0m long pole) complete with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete including dismantling and taking out old/unsv/rusted pole. The job shall consist of the followings:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed. (b) M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed. (c) M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed. (d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block. (e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed. NOTE : Manufacture's test certificate and Purchase voucher of the pole shall be produced before claiming payment in RAR.
Taking down unsv servo voltage stabizer of cap 100 KVA , inspection for defects and transporting to workshop for repair complete all as specified and directed. Note :-(a) The rate shall be incvlusive for electrician for disconnecting stablizer and making connections again after repair, for loading and unloading of stabilizer and vehicle for transportation ) (b) Spare parts shall be measured and paid separately as "S&F in repair" here in under.
Automatic control power card of IC control Based
Variable Transformer of 240V 50Hz. A.C /24VD.C of One amp with continuous supply heavy duty, copper conductor superenemal winding Suitable to match the control card.
Synchronous motor of existing make and capacity
Driver Transformer of 240V 50Hz. A.C /24VD.C of One amp with continuous supply heavy duty, copper conductor superenemal winding Suitable to match the control card.
Potential meter 10watt 5K ohms .
M&L for defect rectification in HT 11000 V cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc complete all as specified and as dire4cted. Note :- (a) Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 240 sqmm 3.5 core. (b) The fault located equipment will be brought at site within 02 hours of Instruction received from Engineer-in-charge complete all as specified and as directed by Engineer-in-charge
M&L for drilling holes under the road without damaging existing road/path to cross the LT UG cable complete all as specified and directed.
prabhawati shanti automobiles
Mohit Enterprises
PITAMBARI TRADERS
Shivam Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .