REPAIR AND RENEWAL OF FAULTY CONTACTORS, MCCBS, WIRING,AND OTHER ALLIED ITEMS OF LT PANEL OF PUMP HOUSES INCL REPLACEMENT OF OLD RUSTED LT PANELS INCL MAINTENANCE OF MOTORS/PUMPS AND DOSING PLANTS UNDER AGE E/M (WS) GE (U) MEERUT CANTT.
2022_MES_540916_4
8459/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Meerut Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U)E/M Meerut
₹90,000
Yes
15 Dec 2022
11 Nov 2022
2 Dec 2022
11 Nov 2022
30 Nov 2022
18 Nov 2022
Amount
S&F (in repair/renewal) new LT switchgear panel board IP-55 (indoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 400 Amps copper bus bars , cubical , factory made out of 2mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 75mmx75mmx6mm with 400mm long extended legs grouting in PCC plateform , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front and back openable doors with proper locking arrangements for dust and vermin proof ,complete including suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable comprising of the followings and specified hereafter:- MCCB 4 pole, 250 Amps, 415V, microprocessor release suitable for isolation, adjustable overload from 0.4-1.0 In adjustable short circuit from 2-12 , 35 KA, -01 No (incoming)
MCCB 3 pole, 200 Amps, 415V, 50KA, FMU )thermal magnetic) release, Adjustable overload 80 to 100% , fixed short circuit -03 Nos Out going, Digital type ampere meter 0-200 Amps, with CT ( for each Phase) square type -01 No, Digital type Votmeter 0-500 volts suare type -01 No LED type indication lamps ( R-Y-B) with holder panel mounting type complete all as specified -01 No, Motor protection compact unit device complete suitable for 75 HP VT pump with single phase protection, High/Low voltage protection, Phase reversal protection, Over load protection, Star delta starter suitable for 75 HP VT pump ( with sheet metal enclosure) sets-02 Nos, 35 sqmm single core copper conductor cable 6 run of suitable length not less than 1.50m each run connected from starter to Motor all as directed.
S&F (in repair/renewal) new LT switchgear panel board IP-55 (indoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 400 Amps copper bus bars , cubical , factory made out of 2mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 75mmx75mmx6mm with 400mm long extended legs grouting in PCC plateform , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front and back openable doors with proper locking arrangements for dust and vermin proof ,complete including suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable comprising of the followings and specified hereafter; MCCB 4 pole, 250 Amps, 415V, microprocessor release suitable for isolation, adjustable overload from 0.4-1.0 In adjustable short circuit from 2-12 , 35 KA, -01 No (incoming)
MCCB 3 pole, 160 Amps, 415V, 50KA, FMU )thermal magnetic) release, Adjustable overload 80 to 100% , fixed short circuit -03 Nos Out going, Digital type ampere meter 0-200 Amps, with CT ( for each Phase) square type -01 No, Digital type Votmeter 0-500 volts suare type -01 No LED type indication lamps ( R-Y-B) with holder panel mounting type complete all as specified -01 No, Motor protection compact unit device complete suitable for 50 HP VT pump with single phase protection, High/Low voltage protection, Phase reversal protection, Over load protection, Star delta starter suitable for 50 HP VT pump ( with sheet metal enclosure) sets-02 Nos, 35 sqmm single core copper conductor cable 6 run of suitable length not less than 1.50m each run connected from starter to Motor all as directed.
S&F (in repair/renewal) new LT switchgear panel board IP-55 (indoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 200 Amps copper bus bars , cubical , factory made out of 2mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 75mmx75mmx6mm with 400mm long extended legs grouting in PCC plateform , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front and back openable doors with proper locking arrangements for dust and vermin proof ,complete including suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable comprising of the followings and specified hereafter
MCCB 4 pole, 125 Amps, 415V, 50 kA, FMU( thermal magnetic) release, adjustable overload 80% to 100%, fixed short circuit , -01 No.(incoming), MCB TP, 63 Amps, 415V, -02 Nos Out going, MCB TP, 40 Amps, 415V, -02 Nos Out going, Digital type ampere meter 0-200 Amps, with CT ( for each Phase) square type -01 No, Digital type Votmeter 0-500 volts square type -01 No,LED type indication lamps ( R-Y-B) with holder panel mounting type complete all as specified. -01 No, Motor protection compact unit device complete suitable up to 30HP motor with single phase protection, High/Low voltage protection, Phase reversal protection, Over load protection, Star delta starter suitable for 30 HP pump set ( with sheet metal enclosure), 16 sqmm single core copper conductor cable 6 run of suitable length not less than 1.50m each run connected from starter to Motor all as directed.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 25 x 4 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with XPM weighing not less than 4 Kg/sqm with 6mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply and fix Power contactor 3 pole upto 50 HP with 415 V/220V , AC Coil including repair/replacement of wiring complete all as specified.
Supply and fix Power contactor 3 pole upto 25 HP with 415 V/220V , AC Coil including repair/replacement of wiring complete all as specified.
Supply and fix only Thermal timer type GT 200, including wiring operating voltage 230/250 Volts, 400/440 Volts, 50 Hz fun 5-18 seconds range complete all as specified.
Taking down and Repair/replacement of MCCB, 4 pole, 160 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal and magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, for 50 HP motor all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .
Taking down old existing duct cover S&F 40CMx 100CM duct cover of GI sheet inclunding dressing of cable complete all as specified and directed by Engr-in-charge.
Taking down and Repair/replacement of MCCB, 4 pole, 200 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, for 75 HP motor all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .
Taking down and Repair/replacement of MCCB, 4 pole, 100 Amps, Icu=25KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, up to 22.5 HP motor all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .
Supply and fix only Electronic Timer ET 100, 110/240 Volts, 50 Hz, range 9-30 seconds up to 75 HP Motor complete all as specified.
Supply and fix phase sequence changer of any type /make capacity 22.5 HP to 75 HP including renewal of U/S parts and wiring as required to made the sequencer serviceable condition.
Taking down of RYB phase indicator and repair/renewal of RYB phase indicator of any size and type on LT Panel as specified and directed.
Supply & fix Single/reverse phase preventor for motor protection with by pass arrangements to run the motor in case of emergency with low/high voltage cut off and time delay/relay of 1 to 3 sec.including dismantling/taking out of unserviceable phase preventor of any make and type complete all as specified and directed.
Supplying, laying or fixing, jointing and testing LT PVC insulated and PVC sheathed single core cable , ISI-1554 marked , with copper conductor , heavy duty 1100 Volts grade of 16 sqmm ,complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.complete all as specified and directed.
Supplying, laying or fixing, jointing and testing LT PVC insulated and PVC sheathed single core cable , ISI-1554 marked , with copper conductor , heavy duty 1100 Volts grade of 35 sqmm ,complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.complete all as specified and directed.
Supplying, fixing and testing ( in repairs) 100 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing ( in repairs) 200 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing ( in repairs) 315/320 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supply and fix electronic motor protection relay up to 75 HP capacity of motor including protection from over load , short ckt current, unbalance load, phase loss, phase reversal,locked rotor, earth,over temprature etc complete all as specified and directed.
M&L for prepration of old painted surface and two coat synthetic enamel paint on old painted steel surfaces of any description over 10cm in width or girth , not otherwise described completel as specified and directed .
Repair and refurbishment of old LT panel body including replacement of damaged door/cover, repair/renewal of lock of panel door/cover, refabrication of damaged parts including all type of machining, welding, sheet metal work required. The job is deemed to include the rate of new parts renewed(if any) and all T&P required for the same complete all as specified of LT panel not larger than 300CMx200CMx80 CMx (All parts renewed must be of colluding material of the panel body)
KUSHAL ENTERPRISES
Ramesh Traders Govt Contractors & General OrderSuppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .