Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC H NO 831 1 HINDU NAGAR TILAKWADI BELGAUM 590006 | BELGAUM | BELGAUM | KARNATAKA | 590006 | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹24.8 L+₹1.8 L (7.64%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹25.1 L+₹2.1 L (9.10%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest hence rejected | |
| 4 | L4₹28.7 L+₹5.7 L (24.8%)Rejected-AOC | L4 | Rejected-AOC 4th lowest hence rejected | |
| 5 | L5₹28.7 L+₹5.7 L (24.8%)Rejected-AOC | L5 | Rejected-AOC 5th lowest hence rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Feb 2024, 6:00 pmClosed
Garrison Engineer Belgaum
Garrison Engineer Belgaum Laxmi Tek,Camp,Belgaum
MAINTENANCE AND REPAIRS TO APFC PANEL, ACBs, CTs, PTs, STABILIZERS INCLUDING REPAIRS AND SETTINGS OF DIFFERENT TYPES OF HIGHLY SENSITIVE PROTECTIVE RELAYS, TIMERS ETC AND RELAYING OF CABLES INCLUDING OTHER CONNECTED WORKS AT BELGAUM MIL STN UNDER GE
2024_MES_636149_1
8987/E8
Open Tender
Civil Works
Item Rate
180 days
Belgaum
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Belgaum
₹60,000
Yes
22 Feb 2024
6 Jan 2024
5 Feb 2024
6 Jan 2024
3 Feb 2024
20 Jan 2024
Amount
Material and labour for Removing of existing HT cable of size 3 core 95 sq mm, 11 kV , GI pipe, existing cable protection cover any type and size, cable route indicator carefully for reuse etc and getting out complete all as specified and as directed. NOTE :- (i) Excavation and earth work shall be measured and paid separately. (ii) The Contractor shall remove and roll the existing cable, GI Pipe, Cable protection cover, etc very carefully for reuse without any damage at new location not more than 10 meters distance from existing trench and the rate quoted by the contractor shall deemed to be included in this item. (iii) The Contractor shall remove the existing cable protection cover very carefully for reuse without any damage at new location not more than 10 meters distance from existing trench and the rate quoted by the contractor shall deemed to be included in this item
Relaying the existing HT cable of size 3 core 95 sq mm, 11 kV , GI pipe, existing cable protection cover any type and size, cable route indicator retrived from item No.1 above NOTE :- (i) The rate quoted by the contractor for this item shall be inclusive of relaying the existing cable, cable protection cover, cable route indicator with PCC works & earth work and GI pipe (ii) Any additional cable protection cover or GI pipe or cable route indicator used shall be paid separately and the GE's decision shall be final on this matter against the site situation
Supply, lay and test HT XLPE insulated, armoured 11000 Volts grade aluminium conductor cable of Cross sectional area 185 sq mm, 3 core as per IS-7098 (Part-II) laiid in trenches or fixed to wall /passing through pipe / pole complete all as specified and as directed . NOTE : (i) Excavation and earth work shall be measured and paid separately under relevent items in this BOQ (ii) GI pipe, Concrete cable cover protectioin and sand cushioning shall be measured and paid separately separately under relevent items in this BOQ (iii) Make of HT cable:Gloster/CCI/Finolex/Poly cab/Universal
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation, laying pipe etc. and getting out in any type of soil complete all as specified and as directed.
Returning filling in soft/loose soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and as directed.
Material and labour for Sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand complete all as specified and as directed.
Supply and laying Precast unreinforced Concrete cable covers Class HV, type 1 flat of size 300 mm x 180 mm x 40 mm for HT cable complete all as specefied and as directed.
Supply and fix HT cable route indicator alongwith necessary excavation and earthwork and PCC for foundation as required complete all as specefied and as directed.
Supply and fix LT cable route indicator alongwith necessary excavation and earthwork and PCC for foundation as required complete all as specefied and as directed.
Material and labour for Cutting the road/hard standing and making good with Plain cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate and filling mass concrete including with necessary steel form work and compacting levelling the concrete etc to match with existing surface complete all as specefied and as directed.
Supply and lay GI tubing light grade 80 mm bore with all fittings laid in trenches/fixed on wall for cable protection complete all as specified and as directed. Note:- (i) The Cost of taking out of old pipe/cable if any shall be included in the unit rate quoted by the contractor under this item .(ii) Make of GI Pipe :TATA/JINDAL/PRAKASH SURYA
Description all as per item no :12 here in before but of 100 mm dia bore
Material and labour for HT Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 11 kV HT, 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. Note : Make: Raychem / Denson/ M-seal.
Material and labour for HT Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 11 kV HT, 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and as directed. Note : Make: Raychem / Denson/ M-seal.
Material and labour for Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 11 kV HT, 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. Note : Make: Raychem / Denson/ M-seal.
Material and labour for Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 11 kV HT, 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and as directed. Note : Make: Raychem / Denson/ M-seal.
Supply and laying Crushed stone aggregate of size 40 mm in compacted thickness of 7.5 cm over a sand cushioning of 5 cm including providing plastic sheet heavy duty with water proof quality 100 GSM weed control barrier sheet in between the aggregate and sand complete all as specified and as directed. NOTE :- (i) The excavation, earth work and sand cushioning shall be measured and paid separately .
Material and labour for Painting to old surfaces of Feeder Pillar box / LT panel of sizes maximum upto 1 metre X 1 metre X 0.40 metre at site with one coat of epoxy based paint DANCOT/Asian make shade / tint as approved including preparation of old surfaces, cleaning rusted portion etc complete all as specified and as directed.
Material and labour for Painting to old surfaces of Feeder Pillar box / LT panel of sizes maximum upto 2 metre X 2 metre X 0.50 metre at site with one coat of epoxy based paint DANCOT/Asian make shade / tint as approved including preparation of old surfaces, cleaning rusted portion etc complete all as specified and as directed.
Material and labour for Minor welding work on hinges, corner sides of LT panels of any size including rent of welding machine and cost of welding rod etc complete all as specified and as directed.
Supply only MCCB 36 KA 4 pole ,400 Amps for replacement in LT Panel boards complete all as specified and as directed. Note :Make :Havells/Indo Asian/L&T/Siemen
Description all as per item no :22 here in before but MCCB 36 KA ,4 Pole ,200 Amps
Description all as per item no :22 here in before but MCCB 36 KA ,4 Pole ,160 Amps
Description all as per item no :22 here in before but MCCB 16 KA ,3 Pole ,125 Amps
Description all as per item no :22 here in before but MCCB 16 KA ,3 Pole ,100 Amps
Material and labour for Servicing of Automatic Power Factor Correction (APFC) panel of the capacity 100 to 125 kVAr complete comprising any type capacitors, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as specified and as directed..
Description all as per item no : 27 here in before but of capacity 125 to 150 KVAr
Description all as per item no : 27 here in before but of capacity 150 to 200 KVAr
Supply only Heavy duty capacitors 3 to 25 kVAr, voltage 440 volt, 3 Phase, cylindrical, having operating losses 0.35 W/kVAr. complete all as specified and as directed..Note :Make :L&T/Siemens/EPCOS/GE/ABB
Supply only APFC relay, 4 Stage, auto set function, having digital display complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only APFC relay, 6 Stage, auto set function, having digital display complete all as specified and as directed.Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only thyristor switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 10 kVAr complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only thyristor switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 25 kVAr complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only thyristor switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 50 kVAr complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 5 kVAr complete all as specified and as directed.Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 12.5 kVAr complete all as specified and as directed.Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to15 kVAr complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 20 kVAr complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 25 kVAr complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/EPCOS/GEC/ABB
Supply only 3 pole contactor 70 amp, type MNX 70,415 volt,3 phase, 50 Hz, 2 NO+2NC complete all as specified and as directed.Note :Make :Note :Make :L&T/Siemens/HAVELLS/GE/ABB
Supply only 3 pole contactor 110 amp, type MNX 110,415 volt,3 phase, 50 Hz, 2 NO+2NC complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/HAVELLS/GE/ABB
Supply only 3 pole contactor 140 amp, type MNX 140,415 volt,3 phase, 50 Hz, 2 NO+2NC complete all as specified and as directed..Note :Make :Note :Make :L&T/Siemens/HAVELLS/GE/ABB
Supply only electronic time switch..Note :Make : L&T/Automatic electric/Secure meter/Havells
Supply only side mounting Add-on block on auxiliary contact block suitable for MOC, 1NO+1NC complete all as specified and as directed.Note :Make :Note :Make :L&T/Siemens/HAVELLS/GE/ABB
Supply only HRC fuse, DIN type fuse links, 250 Amps complete all as specified and as directed...Note :Make L&T/Schneider / C&S
Supply only HRC fuse, DIN type fuse links,160 Amps complete all as specified and as directed...Note :Make :L&T/Schneider / C&S
Supply only HRC fuse, DIN type fuse links, 125 Amps complete all as specified and as directed...Note :Make :L&T/Schneider / C&S
Supply only HRC fuse, DIN type fuse links 80 Amps complete all as specified and as directed..Note :Make :L&T/Schneider / C&S
Supply only LED indicator lamp (RED, YELLOW, GREEN) complete all as specified and as directed..Note :Make :CG/Bajaj/Wipro
Supply only LED indicator lamp (AMBER ,BLUE) complete all as specified and as directed..Note :Make :CG/Bajaj/Wipro
Supply only Push button actuator with carrier any colour complete all as specified and as directed..Note :Make :Schneider / esbee / L& T / Teknic
Supply only PVC Cooling fan for APFC panel 6” sweep as per sample complete all as specified and as directed..Note :Make :CG/Bajaj/Orient
Supply and fix in repairs Automatic power factor correction panel of capacity 150 KVA in 12 stages with micro processor based by Supply, assembly, erection, testing and commissioning of Indoor type floor mounted free standing, dust and vermin proof panel/DB with IP-42 protection CPRI approved ISO 9001 certified frame fabricated out of 40mm x 40mm x 4mm angle iron, 2 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting and
Phosphated, Panel / DB having front and rear opening for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200mm to be kept from floor level for switchgear compartment. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. Each compartment shall be numbered/lettered as per the approved drg. Affixing MV danger plate as suitable intervals/locations, fully internally wired with suitable size of thimbles. Incoming / outgoing internal connection with PVC insulated PVC sheathed multistranded copper wire of suitable size and comprising the following :- Note :Make of APFC Panel: L&T/GEC/Siemens/ABB/EPCOS
BUS BAR CHAMBER :- (a) 400 Amp 3 Strips & Neutral Strip 200 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Schneider.
INCOMING SUPPLY :- (i) MCCB 250 Amps 25 KA , 4 Pole with Adjustable thermal & magnetic release 415 volts , 50Hz,=01 No., (ii) Capacitor Duty Contactor suitable for 1 X 50 + 1 X 25 + 2 X 20 + 2 X 10 + 2 X 5 + 2x 2+1x1 KVAR Capacity ( 2 x Nos Spare) (iii) Power Contactor 18 A 3 Pole for 2 , 1 KVAR = 03 Nos. (iv) Contactor shall be protected with MCB TP 10 KA (v) MCB 63 A 10 KA TP for 50, 25 KVAR = 02 Nos., (vi) MCB 50 A 10 KA TP for 20 KVAR = 02 Nos., (vii) MCB 25 A 10 KA TP for 10 KVAR = 01 No., (viii) MCB 16 A 10 KA TP for 05, 2, 1 KVAR = 05 Nos. Make of MCCB/MCB/Contactor:- L&T/ Schneider/ABB
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) IEC/BS EN 61111: 2009 BIS/ERDA/CPRI approved suitable for electrical shock safety of size 2m x 1m complete all as specified and as directed..(ISI MARKED)
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) IEC/BS EN 61111: 2009 BIS/ERDA/CPRI approved suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed..(ISI MARKED)
Material and labour for Repairing and replacement of earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground in vertical position, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 Metre below ground level connetced with galvanised iron earth strip of size25x 4 mm dia(Upto 7.50 metre length) by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead protected by galvanised iron pipe 20 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary excavation & earth work, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete to obtain less than 1 Ohm earth resistance, fixed in repairs complete all as specified and as directed.
Material and labour for Earth continuity conductor or main earthing lead of size 32 x 6 mm Aluminium strip for connection. fixed to wall on batten on recess or chases or buried in ground or dawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as requiredcompletion all as specified and as directed.
Green Ray Enterprises
M/s. VIJAY ELECTRICALS
M/S Mist Hills Enterprices
M/s.GOODWILL ELECTRICALS
RAHMAT ALI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .