Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | Admitted-Finance |
| 2 | Admitted-Finance MUZAFFARNAGAR MEERUT ROAD GEHRA BAGH OPP PWD WARE HOUSE MUZAFFARNAGAR UTTAR PRADESH 251002 | MUZAFFARNAGAR | UTTAR PRADESH | 251002 | Admitted-Finance |
| 3 | Admitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
Tender Value
₹12.4 L
EMD Value
₹12,500
Closing Date
5 Dec 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC MUZAFFARNAGAR
NEAR 132 KV SUB STATION BHOPA ROAD MUZAFFARNAGAR
ETC MU T 36 2023 24
2023_UPTCL_865526_1
ETC MU T 36 2023 24
Open Tender
Electrical Works
Item Rate
60 days
NARA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD MUZAFFARNAGAR
₹12,500
6 Dec 2023
27 Nov 2023
6 Dec 2023
27 Nov 2023
5 Dec 2023
27 Nov 2023
Amount
SCHEDULE Q-1 (WORK )
Erection of Main & Auxiliary structure consisting of AKR, BKR, ABR, APR, YMR, BBL, BCT, ALP etc. including all allied works complete in all respect. Department shall provide structure & nut and bolts etc. The works shall be strictly carried out as per drawing & technical specification.
Erection of 145 KV SF-6 Circuit Breaker.
Erection of 145 KV PT
Erection of 145 KV Current Transformer.
Erection of 145 KV Control & Relay panel
Erection of 120 KV Lightning Arrester
Erection and mounting of 145 KV CT/PT Junction Box.
Erection of 145 KV Bus & Line Isolator
Erection of 145 KV Post Insulator for support.
Erection of cable termination kit
Laying of 40 mm dia M S round bar below the ground level upto earthing earth mat by the cutting, straightening, welding, painting, excavation of tench back filling of trench after laying of earthmat including shifting of MS round bar from store place at the Sub-Station to switchyard.
Fabrication of 3 meter long electrode with 40 mm dia M S round bar having 150 mm long conical shape by digging cutting, striaghtening etc. and then placing it verticall. inside the ground with Top 700mm below the ground level including shifting of MS round bar from storage place at the Sub-Staiton to switchyard.
Making of cross joint of above laid 40 mm dia M S round below the ground level by duc welding at all 4 corners including welding of suitable size 2 no M S angle pieces on opposite corners of the corss joint.
Making of end joint of above laid 40 mm dia M S round bar with Top of the already vertically pierced M S electrodes 700 mm below the gournd level by duc welding.
Making of 300 mm long lap joint of above already laid round bar to connecting existing earth mat of the Sub-station.
Earthing of equipments by cutting straightening, bending, laying 700 mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipments structure. Excavation of trenches, its back filling and all other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Stringing of various Three Phase Jack Bus ,Main Bus & Transfer bus with ACSR Moose/panther/tarantulla conductor as mentioned below. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
132 KV Main Bus
132 KV Transfer Bus
132 KV Jack Bus
Jumpering, interconnection of equipment with specified conductor of various 132 KV equipments with main/Transfer/Jack Bus Bar of ACC Tarantulla / ACSR Moose/Zebra/Panther conductor. The work includes cutting of conductor, bending in proper shap, clamping with the help of clamps and all other associated work to complete the work.
Laying of following size control cable in trench/cable trays from different control room equipments to 220/132 KV CB, CT,CVT and their juntion boxes. Transformer marshaling box, isolators box and other outdoor equipments installed in 220/132 KV switch yard as per cable schedule including carriage of cable drum from store and all other associated work.
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
Termination of following size control cable as laid above as per cable schedule including making necessory holes in glands plate or box where ever required fixing of cable glands of appropriate size ,lugging and ferruling of each core and other associated work to complete the job satisfactorily.(the rates of termination of control cable including all cores of cable at both end.)
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
Ring earthing(120KV LA) of 3 meter long 40mm ms round having 150mm conical shape.Its peicing vertically inside the ground below 700mm.All 06 rod arrenge in rectangular manner and connecting all 06 nos electrode with 75x10/50x6mm ms flat laid on its edge(all above work in one job)
SCHEDULE Q-2 (SUPPLY )
single Tension fitting for PANTHER Conductor suitable for 132KV Disc insulator without turn buckle.
single Tension fitting for PANTHER Conductor suitable for 132KV Disc insulator with turn buckle.
single Tension fitting for ZEBRA Conductor suitable for 132KV Disc insulator without turn buckle.
single Tension fitting for ZEBRA Conductor suitable for 132KV Disc insulator with turn buckle.
Bolted type Tension fitting for Twin Tarantulla conductor without turn buckle for 132 KV Main Bus suitable for each disc stringing 10 Nos, 70 KN disc insulators with hardware fitting D shackle, eye socket, Ball hook. York plate, I-cleveis tension clamp etc. as per technical specification.
Bolted type Tension fitting for Twin Tarantulla conductor with turn buckle for 132 KV Main Bus suitable for each disc stringing 10 Nos, 70 KN disc insulators with hardware fitting D shackle, eye socket, Ball hook.
Single Suspension fitting for PANTHER Conductor.
Single Suspension fitting for ZEBRA Conductor.
MS Flat of 75x10 mm
MS Flat of 50x6 mm
MS Flat of 25x6 mm
4 Bolted Type PG clamp suitable for Tarantulla to Tarantulla Conductor Complete with HDG nut bolt & washer.
4 Bolted Type PG clamp suitable for Tarantulla TO panther Conductor Complete with HDG nut bolt & washer.
4 Bolted Type PG clamp suitable for Zebra to Zebra Conductor Complete with HDG nut bolt & washer.
4 Bolted Type PG clamp suitable for Zebra to Panther Conductor Complete with HDG nut bolt & washer.
4 Bolted Type PG clamp suitable for panther to panther Conductor Complete with HDG nut bolt & washer.
Bus Post clamp suitable for panther conductor complete with hot dip galvanized nut, bolts & washer.
GI pipe 1.25 inch
Name plate as per sample
phase plate as per sample
danger plate as per sample
Fire Extinghusher foam type 50 ltr
Fire Extinghusher CO2 type 11KG
Fire Extinghusher CO2 type 4.5KG
sand buckets
stand for sand buckets as per sample
Providing 150 Watt LED flood light fitting complete with all accessories of standard (ISI) make like Anokhi/Syska/ Greatwhite.
P&H Engineering
KARAN SINGH
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .