Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹50.2 L
EMD Value
₹1.0 L
Closing Date
4 Oct 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Providing Stage at the Quadrangle HAL Gnanajyothi School, CST, HAL Bangalore.
9731
TENDER NOTICE/NCP/29/24-25/05
Works
Contract Section Civil-FMD-Bangalore
₹0
₹1.0 L
4 Oct 2024
20 Sept 2024
20 Sept 2024
4 Oct 2024
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
PAN No.:
Service Tax Registration No
Goods and Service Tax ID No.
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Registered Contractor
Average annual financial turn over during the last 3 years, ending 31st March 2023 of the previous financial year [ should not be less than 30% of Amount put to tender]
TURN OVER IN Rs.
Pls Enter Turn over in Rupees for all the 3 years
ESI & PF Nos with proof
Remarks if any
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the last date of Tender submission
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending last day of previous month. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
work done
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
DECLARATION II
Pls Accept the Delaration II
Specification
Earth work in excavation over areas in all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth, 1.50m in width as well as 10Sq m on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.50m, etc., all complete as directed by Engineer-in-Charge. Note: The measurement shall be done as per the area of bed concrete/footing. The quoted rate shall be inclusive of any necessary working space.
Surface dressing of the ground includng removal of vegetation and in equalities and not exceeding 15cm deep and disposal of rubbish lead up to 50m and lift up to 1.50m in all kinds of soils, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation over areas in all kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.50m width or 10Sq m on plan) including dresssing of sides and ramming of bottoms for all lift including getting out and disposal of excavated earth lead upto 50m, etc., all complete as directed by Engineer-in-Charge.
Earth work in rough excavation All kinds of soil, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50m and lift upto 1.50m, etc., all complete as directed by Engineer-in-Charge.
Demolishing of dressed stone work ashalr face stone work, marble work, or precast concret work in cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material wihtin 50m lead, etc., all complete as directed by Engineer-in-Charge.
Hacking of CC flooring including claenaing of surface, etc., all complete as directed by Engineer-in-Charge.
Dismantling cement asbestos sheet / FRP / or other hard board ceiling or partition walls tile work in floors and roofs laid in cement mortar including stacking of material within 50m lead for thickness of tiles 10mm to 25mm, etc., all complete as directed by Engineer-in-Charge.
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50meters lead, etc., all complete as directed by Engineer-in-Charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations, etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.50m, etc., all complete as directed by Engineer-in-Charge.
Disposal of moorum / building rubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10km for all lifts, etc., all complete as directed by Engineer-in-Charge. Note: Item to be applicable in urban areas having directions for restricted hours for movement / plying of load carrying motor vehicle of 3.50Cu m or more.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. Supplying, mixing and placing Plain Cement Concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources, etc., all complete as directed by Engineer-in-Charge.
Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level. Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand), etc., all complete as directed by Engineer-in-Charge.
Reinforced cement concrete work in walls (any thickness) including atached pillasters, buttresses, plinth and string courses, fillets, colmns, pillars, piers, abutments , posts and struts above plinth level up to floor level finishing and reinforcement, using 1:1.5:3 ( 1 cement : 1.5 coarse sand ( Zone-III) derived from natural sources :3 graded stone aggregate 20mm nominal size derived from natural sources), etc., all complete as directed by Engineer-in-Charge.
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength including pumping of concrete to site of laying, curing, carriage for all leads but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by Engineer-in-Charge for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
Concrete of M25 grade with minimum cement content of 330Kgs / Cu m all works up to plinth level
All works above plinth level up to floor V level
Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing up to floor five level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources, etc., all complete as directed by Engineer-in-Charge.
Supplying and providing brick work with modular extruded burnt fly ash clay sewer bricks ( conforming to IS : 4885) in foundation in plinth in cment mortar 1: 3, etc., all complete as directed by Engineer-in-Charge.
Centering and shuttering including strutting, propping etc. and removal of formwork, etc., all complete as directed by Engineer-in-Charge.
Foundations, footings, bases of columns, etc., for mass concrete
For retaining walls, return walls , pillasters, buttresses, plinth and string courses fillets , kerbs and steps, etc.,
For suspended floors, roofs, landings, balconies and access platform
For lintels, beams, plinth beams, girders, bressumers and cantlilevers
Supplying and fabricating of Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates, etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts, etc., of required size on the top of the floor or the side of waist slab with suitable arrangement, etc., all complete as directed by Engineer-in-Charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.,)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, inclulding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, etc., all complete as directed by Engineer-in-Charge.
Steel work in built up tubular ( Round, Square or rectangular hollow tubes etc.,) trusses, etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer including welding, bolted with special shaped washers, etc, Complete Electric resistance or induction butt welded tubes, etc., all complete as directed by Engineer-in-Charge.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in stringers, treads, landings, etc., of stair cases, including use of chequered plate wherever required, etc., all complete as directed by Engineer-in-Charge.
Supplying, laying and fixing of 10mm thick multi wall polycarbonate sheets to existing MS framework including fasteners, nuts,bolts, washers, drilling, etc., all complete as directed by Engineer-in-Charge.
Providing, laying, spreading and compacting graded stone aggregate (size range 53mm to 0.075mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub-base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, etc., all complete as directed by Engineer-in-Charge.
Providing and laying design mix cement concrete of M-30 grade, in roads / taxi tracks / runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve / tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction / expansion, construction & longitudinal joints (10mm wide x 50mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, etc., all complete as directed by Engineer-in-Charge. (Item of joint fillers, sealants, dowel bars with sleeve / tie bars to be paid separately using Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer Note:- Cement content considered in M-30 is @ 340Kgs / Cu m. Excess / less cement used as per design mix is payable / recoverable separately.
Providing and fillig in position rubberised bitument hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of EIC using 'A' grade sealing compound conforming to IS 1834, etc., all complete as directed by Engineer-in-Charge.
Providing and laying of 60mm thick factory made cement concrete interlocking paver blocks of M-30 grade by block making machine with strong vibratory compaction of approved size designand shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand , filling the joints with fine sand, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing 18mm thick Area of slab upto 0.50Sq m gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish, etc., all complete as directed by Engineer-in-Charge.
Providing and laying Vitrified tiles Glazed Vitrified tiles Matt / Antiskid finish of size [600 x 600]mm in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3Kgs / Sq m including grouting the joints with white cement and matching pigments, etc., The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily, etc., all complete as directed by Engineer-in-Charge.
Providing Cement plaster of 15mm thick using cement plaster : 1:6 (1 cement : 6 coarse sand) for interior surfaces including necessary scoffolding, etc., all complete as directed by Engineer-in-Charge.
Providing cement plaster in two coats of 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 finished with a top layer 6mm thick cement plaster 1:6, etc., all complete as directed by Engineer-in-Charge.
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50gms / Ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, etc., all complete as directed by Engineer-in-Charge.
Wall painting with two coats premium acrylic emulsion paint go interior grade, having low VOC content less than 50gms / Ltr of approved brand and manufacture including applying of additonal coats wherever require to achieve uniform colour and shade, etc., all complete as directed by Engineer-in-Charge.
Applying priming coats with primer of apporved make and having low VOC content with water thinnable cement primer on wall surface having VOC content less than 50gms / Ltr, etc., all complete as directed by Engineer-in-Charge.
Providing and applying white cement based putty of average thickness 1mm of apporved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.20mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners [100 x 8]mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water, etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, etc., all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable Fixed window / ventilator made of (small series) frame [47 x 50]mm & mullion [47 x 68]mm both having wall thickness of 1.9 ± 0.20mm and single glazing bead of appropriate dimension. (Area upto 0.75Sq m).
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.20mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners [100 x 8]mm size for fixing frame to finished wall and necessary stainless steel screws, etc. , casement door single panel with zinc alloy (Zamak) 3D hinges, multilocking system with cylinder , Zinc alloy powder caoted hnadles on both sides using R3 series with frame (55mm & above) x (55mm & above) and sash ((55mm & above) x (85mm & above) and height upto 2.50m
Providing & fixing glass panes 5.50mm thick glass panes (weight not less than 12.50Kgs / Sq m) with putty and glazing clips in steel doors, windows, clerestory windows, etc., all complete as directed by Engineer-in-Charge.
Dismantling steel work in single sections including dismembering and stacking within 50metres lead in Channels, angles, tees and flats, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing on wall face unplasticised -rigid PVC rain water pipes 110mm dia conforming to IS : 13592 type A including Jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion single socketed pipes, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories form unplasticised rigid PVC rain water pipes 110mm dia conforming to IS : 13592 type A including Jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, etc., all complete as directed by Engineer-in-Charge.
Rupees Thirty Five Lakh Forty Nine Thousand One Hundred Sixty Five and Twenty Five Paise Only
Light Fittings
Supply and fixing on existing wall / ceiling, testing & commissioning of surface mounting, Box type 1X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output Efficacy of minimum100 lm/W., comprising of white powder coated CRCA sheet steel housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire. Other standard accessories including necessary inter-connections and supply of 1 No of 18/20W T8 LED Tube, complete in all respects and as directed by engineer-in-chage. Make & model: The LED tube & batten shall be of CROMPTON-IGP161LT8-16.1XT8+LT8-20-865/Equivalent model of approved make luminaries which meets the above technical specification. complete in all respect and as directed by Engineer-in-charge.
Supply & fixing on the building at a height of 4-6mtr approx. including supply and fixing GI pipe bracket made out of 40mm dia class B GI pipe of 1.5Mtrs long bent to shape with necessary fixing hardwares etc., to fix on building / and testing & commissioning of building light LED light fixture of wattage not exceeding 70/72watts and lumens output not less than 7700/7920 lumens with necessary interconnections consisting of pressure die cast aluminum housing, optical cover made out of heat resistance toughened clear glass / polycarbonate with IP66, operating on single phase 230V 50Hz AC supply, efficient heat sink, colour temperature shall be 5700K±5%, suitable optics for maximizing the spread complete in all respects and as directed by engineer-in-change. The luminaries shall have specific lens for optical dispersion including control gear and power factor of control gear shall be >0.95. The fitting shall have internal surge protection of 4KV and external surge protection of 10KV. LM 79 certification for luminaries & LM80 certificate for LED shall be produced. Any approved make fitting meeting the above technical specification has to be supplied.The LED Light fixture shall be of Bajaj : NEXO P 84L WH PO PC SD /Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply, fixing on wall using suitable MS angle frame work, testing & commissioning of LED flood/focus lighting fixture of wattage not exceeding 80watts, lumen output not less than 9600lumens, lumens efficacy ≥ 120lm/w, made out of die cast aluminum housing, optical cover made out of heat resistance toughened clear glass / polycarbonate, including control gear and mounting arrangment. The The Colour temprature of the fitting shall be >5600K operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V with power factor of driver unit>0.9. LM79 certification for luminares & LM80 certificate for LED shall be produced. including MS angle & necessary hardwares required has to be supplied with the fitting and other standard accessories complete in all respects and as directed by Engineer incharge. Make/model: Bajaj cat no:GLATT MT 96L WH PO PC SD/ equivalent model meeting the above parameter of approved make LED lighting fixtures.
Supply, fixing on wall using suitable MS angle frame work, testing & commissioning of LED flood/focus lighting fixture of wattage not exceeding 120watts, lumen output not less than 14400lumens, lumens efficacy ≥ 120lm/w, made out of die cast aluminum housing, optical cover made out of heat resistance toughened clear glass / polycarbonate, including control gear and mounting arrangment. The The Colour temprature of the fitting shall be >5600K operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V with power factor of driver unit>0.9. LM79 certification for luminares & LM80 certificate for LED shall be produced. including MS angle & necessary hardwares required has to be supplied with the fitting and other standard accessories complete in all respects and as directed by Engineer incharge. Make/model: Bajaj cat no:GLATT MT 144L WH PO PC SD/ equivalent model meeting the above parameter of approved make LED lighting fixtures.
Supply, fixing on wall using suitable MS angle frame work, testing & commissioning of LED flood/focus lighting fixture of wattage not exceeding 150watts, lumen output not less than 18000lumens, lumens efficacy ≥ 120lm/w, made out of die cast aluminum housing, optical cover made out of heat resistance toughened clear glass / polycarbonate, including control gear and mounting arrangment. The The Colour temprature of the fitting shall be >5600K operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V with power factor of driver unit>0.9. LM79 certification for luminares & LM80 certificate for LED shall be produced. including MS angle & necessary hardwares required has to be supplied with the fitting and other standard accessories complete in all respects and as directed by Engineer incharge. Make/model: Bajaj cat no:GLATT MT 180L WH PO PC SD/ equivalent model meeting the above parameter of approved make LED lighting fixtures.
Fan Fixtures
Supply & fixing on existing MS hook 1200mm sweep, Ceiling fans complete with blades, down rods, and accessories, 230V single phase 50Hz AC supply. Minimum air delivery 210cu.m/min with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete, erected in position with necessary flexible copper leads of required colour and with canopy, down rod 300mm length, necessary rubber bushings, clamps nuts,bolts etc., complete in all respects and as directed by Engineer-in-charge.
Supply & fixing on wall using suitable mounting arragements, fixing hardwares, testing and commissioning of 400mm dia, wall mounting, oscillating type fan along with speed regulator, power cord with 6A, 3 pin plug top and other connected accessories etc., including necessary interconnections complete in all respects and as directed by the Engineer-in-charge.
SMC Box
Supply and fixing on the wall using suitable angle iron frame work, fixing hardware, suitable size weather proof SMC box(not less then 140x140x95mm) with hinged lockable cover and providing 16A 6way heavy duty PVC connector inside the SMC box, with suitable knockouts for cable entry & exit as directed by Engineer -in-charge.
Supply and fixing on the wall using suitable angle iron frame work, fixing hardware, suitable size weather proof SMC box(not less then 200x140x95mm) with hinged lockable cover and providing 16A 6way heavy duty PVC connector inside the SMC box, with suitable knockouts for cable entry & exit as directed by Engineer -in-charge.
Point wiring
Wiring to exhaust/wall mounting fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Wiring for power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sm. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6A Switch
16A Switch
3 pin 6A Socket outlet
5/6 pin 16A Socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. As required,
3 Modules
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
12 way, SPN MCB Double door DB
6 Way, TPN, MCCB, Double door Vertical DB
200A, 36KA, FP 415V, MCCB
32 amps. ratings, TPN MCB, "C" curve, 10 KA breaking capacity.
63 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity.
32 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity.
Supply and fixing 6A to 32 A rating, SP 215V 10kA, "C" curve, miiniature circuit bracker suitable for inducive load in the exesting MCB DB complete with connections, testing and commessioning etc., as required.
63 amps. ratings, TPN MCB, "C" curve, 10 KA breaking capacity with Enclosure.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
Supply of 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Aluminium (Al) /Copper (cu) conductor 1100V gr., earthed Armoured (Arm)/un Armoured (un Arm) U.G cables as directed and as per technical specification and as detailed below. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
4 CX 10 Sqmm Aluminium armoured conductor.
3.5 CX 25 Sqmm Aluminium armoured conductor.
3.5CX 95 Sqmm Aluminium armoured conductor
3CX 2.5 Sqmm copper armoured conductor
3CX 2.5 Sqmm copper unarmoured conductor
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
4CX10 Sqmm Aluminium armoured conductor
3.5CX25 Sqmm Aluminium armoured conductor
3CX 95 Sqmm Aluminium armoured conductor
3CX2.5 Sqmm Copper armoured conductor
3CX2.5 Sqmm Copper Unarmoured conductor
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
HDPE Pipe
Supply and laying of 63 mm dia, PN6 HDPE pipe of confirming to IS 4984:19955 in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge.
Supply and laying of 90 mm dia, PN6 HDPE pipe of confirming to IS 4984:19955 in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge.
Earth work in excavation all kinds of soil by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan). Including dressing of sides and ramming of bottoms, for all lift, refilling of same soil including getting out the excavated soil and disposal of surplus excavated soil as directed, with in a lead of 50m.
Concrete cutting/Chipping/Bitumen Road the existing 1:2:4 cement concrete road /pavements / flooring / rock/stone etc.,including disposal of material within 50 metres lead as per direction of Engineer in charge
Re-concreting the cut portion/ closing the dummy cable duct at same area with 1:2:4 cement concrete by employing 20mm graded aggregate granite to smooth finish including curing and form work if any complete in all respects and as directed.
Rupees Seven Lakh Four Thousand Two Hundred Forty One and Fifty Paise Only
Rupees Forty Two Lakh Fifty Three Thousand Four Hundred Six and Seventy Five Paise Only
Approximate Amount Put to Tender
Rupees Seven Lakh Sixty Five Thousand Six Hundred Thirteen and Twenty One Paise Only
Rupees Fifty Lakh Nineteen Thousand Nineteen and Ninety Seven Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN29.pdf
TENDER_DOCUMENT • 1.33 MB
58Checklist.pdf
TENDER_DOCUMENT • 0.19 MB
58PB.pdf
TENDER_DOCUMENT • 0.40 MB
58CivilTenderDrawing.pdf
TENDER_DOCUMENT • 0.03 MB
58ElectricalTenderDrawing02.pdf
TENDER_DOCUMENT • 0.03 MB
58ElectricalTenderDrawing01.pdf
TENDER_DOCUMENT • 0.04 MB
58TB.pdf
TENDER_DOCUMENT • 3.36 MB
58PQ.pdf
TENDER_DOCUMENT • 0.21 MB
58PQF.xlsm
TENDER_DOCUMENT • 0.03 MB
58ECSForm.pdf
TENDER_DOCUMENT • 0.48 MB
58Undertaking.pdf
TENDER_DOCUMENT • 0.57 MB
58PBF.xlsm
TENDER_DOCUMENT • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .