| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-work experience documents not found |
Tender Value
Refer Docs
EMD Value
₹16,400
Closing Date
27 Jun 2023, 11:00 amClosed
Superintending Engineer
15/12 A, Thornhill Road, Civil line, Prayagraj
Supply and Work of System Strengthening under jurisdiction of EUDD Bamrauli, PRAYAGRAJ under Business Plan Year 2023-24
2023_PVVNV_814090_1
08/EUDC-II/PYG/SE/2023-24
Open Tender
Electrical Works
Lump-sum
30 days
Prayagraj
As per Tender Specification
2 documents required · 2 mandatory
₹968
Yes
S.E. EUDC-II, Prayagraj.
₹16,400
Yes
30 Jun 2023
21 Jun 2023
27 Jun 2023
21 Jun 2023
27 Jun 2023
21 Jun 2023
Amount
SUPPLY OF MATERIALS
TAILLESS UNIT 300A
COPPER STRIP 50x6 sqmm
AL LUG 400 SQMM
NUT AND BOLT OFF SIZE
MOUNTING, FITTING & ERECTION OF WORK AS PER RESPO NORM.
Erection of L.T. 300 A Tailless unit,copper strip ,crimping of Lugs etc in existing cubical Box, with the help of channel, clamp & nut bolt etc. (As per pakage no. 31, 32, 33/BP/2023-24)
Removing of T/F 250/400/630 KVA from the plinth along with opening of HT/LT connections Complete in all respect, (All required material will be arranged by the contractor as per Resspo and Electrical Safety rule) (As per pakage no. 30/BP/2023-24)
Reconstruction of 11/0.4 KV Transformer plinth in size 1.5x1.5x 1.8 mtr. Height, including 0.6 mtr. below G.l. in bottom 1:4:8 cement sand and brick ballast; concreting upto 15 cm. thickness after ramming should be done. Thickness of 1st class brick work should be 0.35 mtr. below G.L. and above G.L. It should be 0.23 mtr. brick work bill be done with 1:4 cement, sand mortar, The space between the four walls should be filled with sand by ramming and watering keeping a space of 0.15 mtr on lop for 1:2:4 cement stone ballast and sand concreting. The two channels should be grouted as per direction of site in charge. All the sides of wall above G, L. should be plastered by 1:6 cement sand mortar having 12 mm thickness.(All required material will be arranged by the contractor. as per Resspo and Electrical Safety rule) (As per pakage no. 30/BP/2023-24)
Erection & commissioning of T/F 250/400/630 KVA on plinth along with HT/LT connections. Complete in all respect, (All required material will be arranged by the contractor except 250 KVA T/F as per Resspo and Electrical Safety rule) (As per pakage no. 30/BP/2023-24)
Fixing and providing of Heat Shrink cable type end Terminations suitable for 11 KV, 3x120sq mm XLPE cable and 11 KV 3X120 sq mm ISI mark jointing kit will be arrange by the contractor as per Resspo and Electrical safety rules. (As per pakage no. 29/BP/2023-24)
Outdoor/indoor jointing kit
Dismantling of 11 KV XLPE A.B.cable of old lines and making rolls of removed conductor in proper size( atleast 100 mtr. Roll) and carriage of conductor rolls from site to store Naini. (As per pakage no. 29/BP/2023-24)
Spreading and stringing of 1 ACSR weasel continuous for Hanging of 11 KV cable including binding of insulator,clamp etc complete in all respect. (All required material will be arranged by the contractor except ACSR weasel conductor as per Resspo and Electrical Safety rule) (As per pakage no. 29/BP/2023-24)
Hanging of 3x70 sqmm XLPE cable with the help of weasel conductor. (All required material will be arranged by the contractor except 11 KV 3x70 sqmm XLPE cable as per Resspo and Electrical Safety rule) (As per pakage no. 29/BP/2023-24)
J.L. Enterprises
D N S ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .