Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Technical bid is rejected due to in affidavit written APWD instead of PRI, N&MA, hence not accecpted. |
| Sl No | Description | Qty | Unit | Naveen kumar kashyap L1 |
|---|---|---|---|---|
| 1.00Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. | ||||
| 1.01 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 9.13 | cum | 2,500 ₹22,825 Lowest |
| 2.00 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | 0.44 | cum | 3,000 ₹1,320 Lowest |
| 3.00Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: | ||||
| 3.01 | Asbestos Cement sheet | 43.68 | sqm | 150 ₹6,552 Lowest |
| 4.00Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : | ||||
| 4.01 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.64 | cum | 15,000 ₹9,600 Lowest |
| 5.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 0.88 | cum | 15,300 ₹13,464 Lowest |
| 6.00Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. | ||||
| 6.01 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | 226.08 | kg | 122 ₹27,581.76 Lowest |
Tender Value
₹8.4 L
EMD Value
₹16,775
Closing Date
6 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PRI NMA Mayabunder
Office of Executive Engineer PRI NMA Mayabunder
Repair and Renovation of Cattle Pond near Panchayat Bhawan at Kishorinagar ward No. 02 under Gram Panchayat, Kishorinagar.
2026_RDPRI_25602_1
94/EE/PRI/NMA/MB/26-2027
Open Tender
Civil Works - Others
Works
180 days
Kishorinagar
Refer Tender Document
5 documents required · 5 mandatory
₹500
Executive Engineer PRI NMA Mayabunder
₹16,775
9 Nov 2026
31 Oct 2026
6 Nov 2026
31 Oct 2026
6 Nov 2026
31 Oct 2026
75 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. | |||||
| 1.01 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 9.13 | cum | - | - |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | 0.44 | cum | - | - |
| 3Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: | |||||
| 3.01 | Asbestos Cement sheet | 43.68 | sqm | - | - |
| 4Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : | |||||
| 4.01 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.64 | cum | - | - |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 0.88 | cum | - | - |
| 6Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. | |||||
| 6.01 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | 226.08 | kg | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
NIT94GPKishoringar.pdf
Tender Documents • 3.19 MB
BOQ_27107.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .