Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹9.7 LAccepted-Finance BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | l1 | Accepted-Finance L1 | |
| 2 | l2₹10.4 L+₹70,480 (7.30%)Rejected-Finance | l2 | Rejected-Finance l2 | |
| 3 | l3₹10.4 L+₹76,165 (7.88%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | l3 | Rejected-Finance l3 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
21 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAVY LAKSHADWEEP
GE NAVY LAKSHADWEEP COAST GUARD ROAD KAVARATTI
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY PUMPS AND REPLACEMENT OF PIPELINE AT NAVY AND COAST GUARD UNITS AT MINICOY UNDER GE NAVY LAKSHADWEEP
2020_MES_389783_1
8268E8
Open Tender
Civil Works
Item Rate
180 days
MINICOY
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE NAVY LAKSHADWEEP
₹29,000
24 Feb 2021
26 Oct 2020
23 Nov 2020
26 Oct 2020
21 Nov 2020
9 Nov 2020
26 Oct 2020 - 2 Nov 2020
60 days
Amount
Dismantling the centrifugal/Submersible pump set of capacity 1 HP of any make and transportation to workshop for replacing unserviceable parts such as impeller,shaft,bearing etc and reconnecting back the pumpset to its original position and testing complete all as specified and as directed by Engineer in charge.
Dismantling the centrifugal/Submersible pump set of capacity 1.5 HP of any make and transportation to workshop for replacing unserviceable parts such as impeller,shaft,bearing etc and reconnecting back the pumpset to its original position and testing complete all as specified and as directed by Engineer in charge.
Dismantling the centrifugal/Submersible pump set of capacity 1 HP of any make and transportation to workshop for rewnding the three phase induction motor with fine enamelled copper insulated wire of same size,guage & turns and keeping it in hot air oven till the moisture evaporates and reconnecting back the motor to its original position and testing complete all as specified and as directed by Engineer in charge.
Dismantling the centrifugal/Submersible pump set of capacity 1.5 HP of any make and transportation to workshop for rewnding the three phase induction motor with fine enamelled copper insulated wire of same size,guage & turns and keeping it in hot air oven till the moisture evaporates and reconnecting back the motor to its original position and testing complete all as specified and as directed by Engineer in charge.
Disconnecting and removing the unserviceable DOL starter and Supplying, fixing and testing new DOL starter, pre wired consisting of Single phase preventer, Electronic timer, Main power contractors 3Phase, 440 V AC, 50 Hz suitable for motor capacity upto 5 HP complete all as specified and as directed by Engineer in charge. Make :- L & T/C & S/ Seimens as approved by GE.
Supply and fix in replacement PVC foot valve, 65 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement PVC foot valve, 50 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement PVC foot valve, 40 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement PVC foot valve, 32 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement CPVC Ball valve, 50 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement CPVC Ball valve, 40 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement CPVC Ball valve, 32 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement CPVC Ball valve, 25 mm bore including necessary fittings complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement 50 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement 40 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement 32 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement 25 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer in Charge.
Material and Labour for cutting of concrete in ground floors and pavings n.exc 15 cms thickness (below or above ground level) for road cutting channel to lay pipes Complete all as specified and as directed by Engineer in Charge.
Material and Labour for Plain cement concrete type B-2,1:2:4 (40 mm graded aggregate) upto 100mm thickness for making good to area of concrete road cut complete all as specified and as directed by Engineer in Charge.
Material and Labour for construction of 200mm thick PCC solid block wall masonary valve chamber (of internal dimension 600x600x600mm) built in CM 1:6 with and including 150mm thick PCC foundation 1:2:4 type B-1 coping 50mm thick finished even and smooth, rendering 10mm thick in cement mortar (1:6), finished fair and and even externally including excavation earthwork in any strata, 6mm thick MS sheet cover fixed on angle iron frame 25x4mm embedded in PCC coping with locking arrangement and mild steel hold fast, mild steel handles and painting to steel surface with two coats of black bituminus paint over one coat of red oxide primer etc, including the demolishing PCC Chamber complete all as specified and directed by engineer in charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 depth and getting out in soft/loose soil for laying cables/pipes/erection of poles etc. complete all as specified and as directed by Engineer in charge.
Returning filling in, with excavated soils including, spreading, levelling, watering and well ramming in layers n.exc. 25 Cms. complete all as specified and as directed by Engineer in charge.
Removing excavated material/ surplus soil exceeding 250m and n.exc. 500m and depositing where directed at a level n.exc. 1.50m above the starting point complete all as specified and as directed by Engineer in charge.
Disconnecting and taking down the userviceable spare parts from ALTOCH DOSING SYSTEM and checking the functioning of ALTOCH DOSING SYSTEM (MODEL ADS-I) consisting of single phase motor 120Watts & Level Guage along with Agitator with shaft & blade in Plastic, mounted on tank, along with DECRIN DOSING PUMP MODEL 96NGQ51 High Pressure Single Head Gear Motored Adjustable dosing pump with accessories including Lead Tubing, Connecting Nuts, Injection Check Valve, Clay Weight, and Ferrules with complete approx under load Motor shaft dia: 15mm X length: 50mm Motor is flange mounted 4 no. of 7mm dia holes at PCD 150mm COMPLETE SHAFT WITH IMPELLER Shaft MOC and reconnecting the same after testing complete all as specified and as directed by Engineer in Charge. Note : Spare parts will be measured and paid separately.
Supply and fix 40 liter-100 liter PE/FRP Tank with PE/FRP lid as per requirement at site and as directed by Engineer in Charge. Make shall be conforming to IS standards, compatbile with the existing unit/Plant and as approved by GE.
Supply and fix 230V 50HZ MOTOR single phase, 50 Hz Current consumption: 0.4 amperes Power: 120 watt Speed 920 RPM 4 pole induction non-synchronous as per requirement at site and as directed by Engineer in Charge. Make shall be conforming to IS standards, compatbile with the existing unit/Plant and as approved by GE.
Supply and fix Poly Propylene rigid dia: 32mm X length 500mm Impeller as per requirement at site and as directed by Engineer in Charge. Make shall be conforming to IS standards, compatbile with the existing unit/Plant and as approved by GE.
Supply and fix in replacement MCCB 63 A, 3P, 415 volts, 10 kA ruptruing capacity Conforming to IS/IEC 60947-2 & IEC 60947-2 with adjustable thermal setting: 0.8-1.0 x In along with necessary fixing arrangements complete all as specified and directed by Engineer in charge. Make :- L&T / Legrand/ Siemens as approved by GE.
Supply and fix in replacement MCCB 100 A, 3P, 415 volts, 25 kA ruptruing capacity Conforming to IS/IEC 60947-2 & IEC 60947-2 with adjustable thermal setting: 0.8-1.0 x In along with necessary fixing arrangements complete all as specified and directed by Engineer in charge. Make :- L&T / Legrand/ Siemens as approved by GE.
Supply and fix in replacement three phase power factor capacitor of capacity 25 KVAr , 440 V , 50 Hz along with necessary fixing arrangements and testing complete all as specified and directed by Engineer in charge. Make :- L&T / C&S/ Siemens as approved by GE.
Supply and fix in replacement three phase power factor capacitor of capacity 15 KVAr , 440 V , 50 Hz along with necessary fixing arrangements and testing complete all as specified and directed by Engineer in charge. Make :- L&T / C&S/ Siemens as approved by GE.
Supply and fix in replacement three phase power factor capacitor of capacity 10 KVAr , 440 V , 50 Hz along with necessary fixing arrangements and testing complete all as specified and directed by Engineer in charge. Make :- L&T / C&S/ Siemens as approved by GE.
R.K. Builders
KRA Engineering and Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .