Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹34.1 L+₹47,439 (1.41%)Rejected-Finance GADADHAR PALLY PO PS BAGDOGRA DIST DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹35.3 L+₹1.7 L (4.93%)Rejected-Finance C O PULOKE NEOGI SURYA SEN PALLY PO KADAMTALA 734011 DIST DARJEELING WB | KADAMTALA | DARJEELING | WEST BENGAL | 734011 | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹35.4 L+₹1.8 L (5.32%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹35.9 L+₹2.3 L (6.77%)Rejected-Finance | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
22 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
CLEANING AND UPROOTING OF VEGETATION GRASS OF AIRFIELD AREA AT 20 WING AFS BAGDOGRA AND REPAIR/ REPLACEMENT OF INTERNAL WIRING, FITTINGS, FAN, GEYSER AND FIXTURE AT 46 WEU UNDER GE (AF) BAGDOGRA
2023_MES_597308_1
8507/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹46,000
Yes
25 Jul 2023
1 Jun 2023
23 Jun 2023
1 Jun 2023
22 Jun 2023
15 Jun 2023
Amount
Mechanized cleaning of vegetation and grass around the Runway, Taxi track and Link roads of Runway/Taxi track within Air Force station Bagdogra by providing CHIARA type jungle jim 01 No duly providing tractor having maximum 45 HP power including 01 driver and 03 helpers including fuel (Diesel), lubricant, engine oil etc complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Daily log book shall be maintained by the contractor and obtain the signature of users and concerned JE. (ii) No claim shall be entertained of the machine is not required for full working days for any days as directed by Engineer-in-Charge. (iii) Jungle jim alongwith tractor arranged by the contractor and when required and as directed. (iv) Grass cutting work to commence in evening/night shift after flying hours (i.e. after 1700-1800 hrs).
Taking down carefully copper/aluminium point wiring complete (light, fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets, removing materials to store and offering credit & making good of disturb surfaces of wall/floors etc as specified & directed.
M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metallic bodies of luminaires/ fan at other end complete as per site requirement and all as specified & directed by Engr-in-Charge for One light point or one fan point controlled by one switch with cables 1.5 sq. mm size. Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
All as per ser item No. 3 above, but for One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No. 3 above, but for One 5 Amp 5 pin socket outlet point on independent board.
All as per ser item No. 3 above, but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes.
All as per ser item No. 3 above, but one light point controlled by 2 way switches.
All as per ser item No. 3 above, but one bell/buzzer point controlled by one push button on the same board with other switches or independent.
M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing caping/ PVC Conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, columns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metallic bodies of luminaire/ fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc as per site requirement and all as specified & directed by Engr-in-Charge for One light point or one fan point controlled by one switch with cables 1.5 sq. mm size.
All as per ser item No. 9 above, but for One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No. 9 here in before but for One 5 Amp 5 pin socket outlet point on independent board.
All as per ser item No. 9 above, but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes.
All as per ser item No. 9 above, but one bell/buzzer point controlled by one push button on the same board with other switches or independent.
All as per ser item No. 9 above, but one light point controlled by 2 way switches.
S&F bell push, flush type, 5 Amp single pole, 230 volts white finish all as specified & directed.
S&F switch piano flush button 5 Amp single pole 2 way 230 volts white finish all as specified & directed.
S&F in replacement switch piano flush button 5 Amp single pole one way 230 volts white finish all as specified & directed.
S&F in replacement of socket outlet flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
S&F in replacement switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
S&F in replacement of switch socket combination multipurpose flush type 2 in 1 type (3 and 5 pin) 5/15 Amps, 230V, AC all as specified & directed.
S&F in replacement ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish all as specified & directed.
S&F in replacement surface and wall mounted LED batten 20 watt - 4Ft White with Aluminium housing & integrated electronic driver, high performance batten and efficacy should not less than100 lumen/watt and all as specified and directed.
S&F in replacement surface and wall mounted LED batten 10 watt - 2Ft White with Aluminium housing & integrated electronic driver, high performance batten and efficacy should not less than 100 lumen/watt and all as specified and directed.
S&F in replacement LED light fitting 1x9W/ 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size as per site requirement and all as specified and directed.
S&F in replacement energy efficient Street/ Roadway/Building Security Luminaire LED fitting upto 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, including brackets and all accessories needed to fixed to the wall or pole all as per site requirement and as specified and directed.
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator Socket type on the existing phenolic laminated sheet etc. as reqd all as specified and directed of approved make.
S&F in replacement exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete as per site requirement and all as specified and directed of approved make.
Taking down carefully copper/aluminium sub main wiring complete alongwith all connected accessories etc as specified & directed.
S&F submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main with colour code Red Black and Green. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
S&F submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 10 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 10 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main with colour code Red Black and Green. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
S&F submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty PVC casing caping upto 32mm or PVC conduit upto 25mm on wall surface/ recessed as required at site including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates.
S&F submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 4 Sqmm drawn through in and including rigid PVC heavy duty PVC casing caping upto 32mm or PVC conduit upto 25mm on wall surface/ recessed as required at site including 4 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates.
Taking down, strip opening, cleaning all parts and packing of ceiling fan of any make and size and greasing ball bearing with specified quality grease and re-assembling the ceiling fan as a one unit, complete all as specified. Note : Replacement of spare parts such as rewinding, painting, cable for connection etc., to be measured and paid separately under relevant items.
All as per srl No 34 above, but of exhaust fan any make and any size complete all as specified and directed.
Hanging only ceiling fan in position after necessary repairs and re-commissioning the same including making electric connection complete all as specified and directed.
Hanging only exhaust fan in position after necessary repairs and re-commissioning the same including making electric connection complete all as specified and directed.
M&L for rewinding of ceiling fan of 1200 mm size complete with super enamelled insulated copper wire of suitable size/gauge and varnishing including oiling, greasing, and replacement of old unsv or weak capacitor of suitable capacity as per manufacturer and testing complete in MES store yard all as specified and directed. Note:- The retrieved unserviceable winding wire shall be handed over to store and RV obtained.
All as per item No. 38 above, but for ceiling fan of 1400mm sweep. Note:- The retrieved unserviceable winding wire shall be handed over to store and RV obtained.
M&L for rewinding of exhaust fan of upto 350mm sweep with super enamelled insulated copper wire of suitable size/gauge and varnishing including oiling, greasing, and replacement of old unsv or weak capacitor of suitable capacity as per manufacturer and testing complete in MES store yard all as specified and directed. Note:- The retrieved unserviceable winding wire shall be handed over to store and RV obtained.
All as per item No. 40 above, but for Exhaust fan of 380mm to 450mm sweep complete all as specified and directed. Note:- The retrieved unserviceable winding wire shall be handed over to store and RV obtained.
Supply only shaft of ceiling fans including matching work for any make as per sample all as specified and directed.
Supply only shaft of Exhaust fans including matching work for any make as per sample all as specified and directed.
Supply only gun metal bush for fans of any make, type and size all as per sample approved all as specified and directed.
Supply only ball bearing No. 6200/6201/6202 for ceiling/exhaust fans of any size and makes all as directed of sample as approved all as specified and directed. (Make:- NBC/SKF/HCH)
All as per item No 45 above, but for ball bearing No. 6203/6204 for exhaust fans.
M&L for cleaning and de-scaling/greasing of exhaust fan and louvers with necessary cleaning materials and including painting with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc as specified and directed upto connecting complete. Note:-Taking down and refixing of exhaust fan will be measured and paid separately under relevant items.
Supply only MS louvers suitable for exhaust fan of size upto 350mm sweep complete all as specified and directed.
Supply only rubber reel with nut, bolts, split pins etc of ceiling fan with rubber reel heavy duty for hanging fan all as specified and directed.
Supply only Shackle assembly (hanging clamp set) suitable for hanging down rod of ceiling fan 1200/1400 mm sweep complete with nuts, bolts, washers and split pin complete all as specified and directed.
Supply only down rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.30 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and directed.
Supply only capacitor suitable for ceiling fans with capacitor having capacity 2.5mfd, 240 Volts all as specified and directed.
All as per srl item No 52 above, but of capacity 3.15mfd.
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
All as per item No. 54 above, but gray paint for Exhaust fan of any size and make complete all as specified and directed.
Taking down geyser 25/50 ltrs capacity of any make, opening up for inspection descaling by chemical treatment of internal tank, thermostat pipe, base plate assembly carrying out minor repairs including testing for water tightness and pressure and refixing in position including making electrical and water connection all as directed.
S&F heating element Triangle/Cup Type 1.5 KW in replacement for any make of geyser of 25 litres capacity as per site requirement and sample approved all as specified and directed. (Make : Micron/Theta/ Standard or ISI Marked as approved).
All as per srl item No 57 above, but of 2.0 KW capacity (Make : Micron/Theta/ Standard or ISI Marked as approved).
S&F in replacement thermostat upto of size 9" long, auto cut/push button type all as specified. (Make : Micron/Theta/ Standard or ISI Marked of approved make).
All as per srl item No 59 above, but of size 11" long, auto cut/push button type all as specified. (Make : Micron/Theta/ Standard or ISI Marked of approved make).
S&F in repairs indicating lamp round /flat type as required in replacement for geyser 25/ 50 litres capacity as per sample approved all as specified and directed.
S&F in repairs Non Return Valve ISI marked for geyser 25/50 litres capacity in replacement as per sample approved all as specified and directed.
S&F in repairs safety plug/valve for geyser 25/50 litres capacity in replacement as per sample as per sample approved all as specified and directed.
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25/35/50 ltrs capacity of any make and make the shell water tight including testing all as specified and directed. Note:-Taking down, de-scaling, replacement of rubber gasket and any minor repair involved will be measured and paid separately.
S&F Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed .
S&F in replacement MS fastener bolt 8mm dia and upto 150mm long for fixing geyser/Exhaust fan with nut and washer complete all as specified and directed.
Periodical maintenance and servicing of Overhead Gantry, EOT Crane and allied Electrical and Electronic systems and accessories including (i) Servicing of wheels (ii) Inspection of electrical fittings (iii) Servicing of Brakes (iv) Inspection of electrical motors (v) Inspection of electronics and control systems (vi) Inspection of ropes and wires for proper functioning of gantries and Cranes upto 02 Metric Ton. Minor repairs and consumables like Mobil, grease, gear oil, electrical and electronic spares and works of petty nature to be include in servicing complete all as specified and directed.
All as per item No 67 above, but for 06 Metric Ton.
All as per item No 67 above, but for 10 Metric Ton.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
UNISON CONSTRUCTION
SHRI P P SHARMA
RAMKRISHNA NARAYAN ROY & CO
M/s Chakraborty Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .