RequiredExperience with Government
RequiredAnnual Turnover
RequiredOEM Authorization Certificate Bid to RA enabled Yes Modular Cold Rooms ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE/SIZE TEMPERATURE Application Forensic
Requiredlaboratories
RequiredH ospitality
RequiredPharmaceutic al
RequiredHoriculture
RequiredFloricultu re
RequiredSericulture
RequiredBiotechn ology
RequiredDairy and Food Processing Forensic
Requiredlaboratories
RequiredHospitality
RequiredPharmaceutical
RequiredHoriculture
RequiredFloriculture
RequiredSericulture
RequiredBiotechnology
RequiredDairy and Food Processing 1/5 Type Chiller (Positive Temperature Condensing unit) Chiller (Positive Temperature Condensing unit) "Size - Outer Dimensions (feet x feet x feet)" 6x6x8 6x6x8 Maximum Ambient Temperature 45 * Cold Room set Temperature Range(Degree C) (+ 2 to + 8) (+ 2 to + 8) Tolerance on Cold Room set Temperature Range (±) 1 * RH Range 61 to 80 40 to 60 (With dehumidifier)
Required61 to 80
Required81 to 95 (With Humidifier) COOLING UNIT Evaporating Temperature -3 -3
Required-28 Total Number of Cooling Units 2 * Standby units (for Redundancy) 1 0
Required1
Required2 "Nominal cooling Capacity of each unit of the Chiller @ evaporating Temp (BTU/hr) 6000 6000
Required10000
Required15000
Required20000
Required30000
Required40000
Required60000
Required80000
RequiredNA FOR FREEZER TYPE "Nominal cooling Capacity of each unit of the Freezer @ evaporating Temp (BTU/hr) NA FOR CHILLER TYPE 6000
Required9000
Required12000
Required18000
RequiredNA FOR CHILLER TYPE Type of Compressor Reciprocal Reciprocal Compressor Sealing Fully Hermetical * Number of Fans in each evaporator unit 1 * Size of Evaporator Fans 12 * Number of Fans in each Condersor unit 1 * Size of Condensor Fans 16 * Maximum Sound level in dB - * Length of Refregirant Piping inclusive in the scope of supply Upto 30 meter Upto 30 meter 2/5 CONSTRUCTION Insulation Type Cyclopentane * Insulation Panel Thickness (Minimum) 60 60
Required80
Required100
Required120
Required150 "Density of Panels (± 2) (Kg/cubic meter)" 40 * Floor Lamination Aluminium Chequered Sheet Anti Skid GI Sheet
RequiredAluminium Chequered Sheet External Panel lamination Material Stainless Steel Sheet - Gr-304 Pre-Painted Galvanized Iron Sheet (PPGI)
RequiredStainless Steel Sheet - Gr-304 Internal Panel lamination Material Stainless Steel Sheet - Gr-304 Pre-Painted Galvanized Iron Sheet (PPGI)
RequiredStainless Steel Sheet - Gr-304 External Panel Sheet Thickness 0.5 * Internal Panel Sheet Thickness 0.5 * Cold Storage Door Type Flush Type Sliding Door
RequiredSwing Hinge Door
RequiredFlush Type
RequiredOverlap Type Number of Doors 1 * Location of the Door As per buyer's approved Drawing * Locking Mechanism Cam Lock with metallic plunger Embedded in Foam * Number of Racks/Rack Size As per buyer's approved Drawing * Number of adjustable shelfs in each Rack 4 4 Rack Material SS SS Load bearing capacity of Rack 75 50
Required75 Or higher DISPLAY/CONTROL INTERFACE Display Features LCD
RequiredBcklit LCD
RequiredLED
RequiredBacklit LED
RequiredTFT
RequiredTouch Screen Display
RequiredMonochrome Display
RequiredColour Display LCD
RequiredBcklit LCD
RequiredLED
RequiredBacklit LED
RequiredTFT
RequiredTouch Screen Display
RequiredMonochrome Display
RequiredColour Display Diplay Size 10 2 - 12 "Parameters Displayed (Select only the Displayed parameters)" Temperature
RequiredRH
RequiredBarom etric Pressure * 3/5 SALIENT FEATURES "salient Features (Select applicable features only)" Food safe and CFC free refrigerants used
RequiredMicro- processor based electronic control panel board
RequiredPower Panel with necessary accessories
RequiredDefrost controls available for Negative Temperature Units
RequiredNA Food safe and CFC free refrigerants used
RequiredMicro- processor based electronic control panel board
RequiredPower Panel with necessary accessories
RequiredDefrost controls available for Negative Temperature Units
RequiredNA POWER Power Supply Single Phase
Required230 ± 10% V AC Single Phase
Required230 ± 10% V AC Power Consumption - * INSTALLATION & COMMISSIONING Installation and Commissioning With Installation and Commissioning (inclusive in the scope of supply) * WARRANTY Warranty on Compressor Equipment 3 3
Required5
Required7 Or higher Warranty of Cold Storage Room 1 1
Required2
Required3 Or higher * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.