Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.5 L+₹72,358 (3.66%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹22.1 L+₹2.3 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹23.2 L+₹3.4 L (17.4%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹23.4 L+₹3.7 L (18.5%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
6 Mar 2023, 6:00 pmClosed
GE(South) Bangalore
GE(South) Bangalore
SPL REPAIR FOR EXISTING STREET LIGHT INTO LED STREET LIGHT AT GTOC, VLO, SOC, AGE E/M YARD, PCDA AREA AND OTHER SANCTIONED WORKS UNDER GE(SOUTH) BANGALORE
2023_MES_579338_1
8678/E8
Open Tender
Civil Works
Item Rate
120 days
GE(South)
As per tender document
6 documents required · 6 mandatory
₹500
GE(South) Bangalore
₹60,000
Yes
9 Mar 2023
6 Feb 2023
8 Mar 2023
6 Feb 2023
6 Mar 2023
20 Feb 2023
Amount
Supply and fixing of street light fitting for 60 watt LED with lens, compact street light fitting with deep drawn MS housing complete with acrylic cover including suitable driver set including taking fown of old U/S street light fittings from pole complete all as specified and directed.by Engr in Charge Make: - Bajaj cat part No - ENXT P 60L WW CR PCSD or equivalent to CGj/Philips
Supply and fixing LED 150 Watt rectangular Flood light with innovative thermal managaement available in multiple optics and equipped with IP-66 Protection complete including three core flexible wire connection from junction box to light fitting including taking down of old U/S MH/SV flood light 250/400watt from pole complete all as specified and as directed. Make- Bajaj cat Part No - BJFL-150W LED I or equivalent of CG/Philips
Supply and fixing LED 25 W decorative post Top Lantern 360 degrre indirect light with IP-65 protection resistant to impact and corrosion Glare free and better uniformity incl connection of flexible wire 2 core wire existing connection to fitting including taking down of old U/S post top lantern from pillar disconnecting electric connection complete all as specified and directed by Engr-in-Charge Make- Bajaj cat part No - BGCTN 25W LED WW or equivalant of CG/Philips
Supply and fixing of Thermoplastic IP 66/69, weather proof, corrosion free, halogen and silicon free, UV reistence, insulated and shock proof, High impact strength, flame retardant and self extinguishing, Glow wires test conducted at 960 Deg junction box suitable for terminating cable for 6Sqmm/10 Sqmm/16 Sqmm including necessary cable gland and check nut Size of M32 (incoming and out going cables) and mounting bracket clamp suitable size as per site with nut bolt washer including taking down of old junction box any size any capacity complete all as specified and directed. (Make- Hensel Cat Part No -KF1010B and Cable Gland Cat Part No 1555.13.12)
M&L for GI bracket for street light fittings 32mm dia 1.2Mtr length including D/C clamps for PCC/Steel pole round or square nut bolt and washers etc and painiting of bracket and clamps including taking down of old U/s GI bracket any type any size complete all as specifiedf and directed by Engr in Charge
S&F PVC Conduit pipe from PVC Junction Box to street light bracket for protection of cable fixing clamp on PCC poles drilled the hole and insert a PVC gutti and screwed suitable size but bolt including taking down of Old U/s pipe any size complete all as specified and as directed.
S&F PVC 3 Core copper cable 1.5 Sqmm insulated for fixing of junction box to street light fittings including taking down of old U/S cable any size and any type complete all as specified and directed.
Supply and fix of ceiling fan complete with electronic type regulator and accessories 230 V, 1200mm sweep,star rated energy saving fans including dismatling old one deposit to AGE E/M Yard complete all as specified and as directed.
Supply and fix Exhaust fan 300mm metal body 1400 RPM single phase 230 volt air delivery 1300CMH complete all as specified and directed including dismatling old one deposit to AGE E/M Yard complete all as specified and as directed.
Supply and fix Exhaust fan 450mm metal body 1400 RPM single phase 230 volt air delivery 1300CMH complete all as specified and directed including dismatling old one deposit to AGE E/M Yard complete.Make- Bajaj product code 70046 /CG/Havells
S&F PVC flexible twin core wire 1.5 Sqmm copper cable for connection celing fan to ceiling rose 45 RM Length Make- Anchor
Supply and fix Wall Mounted Fan 400mm metal body 1400 RPM single phase 230 volt air delivery 1300CMH complete all as specified and directed including dismatling old wall fans 600mm from site and deposit to AGE E/M Yard complete all as specified and as directed.
Supply, laying, testing and commissioning of LT under ground cable XLPE in repair insulated armoured, heavy duty, elelctric cable, size 50 Sqmm 3 1/2 Core with stranded aluminium conductor, 1100 Volts grade conforming to IS -7098 (Part-I) 1988 laid in trenches /walls/floors /ducts etc fixed with saddle and clamps or passing through pipes complete with cable ends connection with proper thimbles nut bolts washer all as directed . (Make- Plaza/ Havells/ Finolex)
Supply, install, commissioning and testing of submersible pump complete with all accessories of capacity 15 Hp/11.5 KW etc. of max 150mm dia bearing ISI Mark, pump conforming to IS 8034 1976 with over efficiency of pump being more than 50% and motor conforming to IS9283/1976 to operate on 415 volts (10%-15%) SNY AC supply suitable for vertical installation suitable for 150mm pipe dia. capable of delivering below mentioned discharge against respective dynamic head including all necessary accessories such as strainer guard pressure compensation device standard cable lead, built in non return valve pump motor coupling etc. complete. The impeller and diffuser should be made of noryl / industrial plastic and stainless steel housing and stainless steel shaft having resistance to abrasion discharge in Ipm ranging from 4750 to 280 Litres per min (LPM) and dynamic head in metres ranging from - 8 to 18 metres, 1440 RPM , 3 phase AC supply etc with necessary electric copper cable connections of size 6 Sqmm x 3 core upto 15 metres, alongwith control panel for operating pumpset and associated civil works and making surfaces good complete as required at site for installation of pumpset as directed by the Engineer in Charge. Make Kirloskar Model No. Eterna 11000CW 4PL
Material & Labour required for fixing new sub-mercible motor outlet with flanged joint of size 150 mm outlet with proper modification of existing pipe line from motor outlet to existing Main Gutter line, out side of DAD complex with appx length 20RM including necessary cutting, welding with new nut,bolt and washers etc complete all as specified and directed by Engr in Charge.
Material & Labour required for cleaning of exsiting sump of DAD complex including mouths of connected pipes etc by dewatering the sumps by using a portable pumpset of suitable capacity, removing all sludge/mud/dirt etc manually, pouring fresh water in sump through another pumpset, rinsing and dewatering the sumps including removing sludge/dirt particle manually, wash the sump using fresh water mixed with sodium hypochlorite & drain out water by a pumpset and finally applying one coat of antibacterial sodium hypochlorite solution to inner surface & writing date of cleaning complete all as specified and directed by Engr in Charge .
Supply and fixing LED flood light of capacity 180 Watt fittings made up of pressure die cast aluminium housing with toughned glass and high power LED secondary lenses with IP 66 protection , option 5700K 10KV SPD, including dismatling old one complete all as specified and directed Make - Bajaj Cat part No GLEAM F 198L WH SY PC SD V2 or equivalant of Wipro/Philips.
S&F PVC Conduit pipe from PVC Junction Box to street light bracket for protection of cable fixing clamp on PCC poles drilled the hole and insert a PVC gutti and screwed suitable size but bolt including taking down of existing conduit pipe any size and capacity complete all as specified and as directed.
S&F PVC 3 Core copper cable 1.5 Sqmm insulated for fixing of junction box to street light fittings including taking down of existing wire complete all as specified and directed Make- Anchor
M&L for fabrication work square type angle iron frame for suitable size top of eletric pole for fixing of 8 No LED flood lights on existing steel pole area cutting , grinding, welding , drilling, fixing all as per specified and directed by Engr in Charge .
S&F sheet metal enclosure (for DB's when MCBs to be used), single pole and neutral double door, 8 way, 240 Volts including taking down of existing one complete all as specified and as directed.
S&F MCB single pole and neutral 40 Amps, 240 Volts, including taking down of existing one complete all as specified and as directed.
S&F MCB single pole, 240 volts 40 Amps, including taking down of existing one complete all as specified and as directed.
GS TRADERS
Gee Kay Projects
RAMSON TRADERS
kamadhenu Electricals
SREE VARU ELECTRICALS
SREE VINAYAKA ENTERPRISES
M/S DK Enterprises
M/S KVG CONSTRUCTIONS
RRK PROJECTS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .