Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
1) RMO Specialized Electrical and Mechanical services at Trade , Taxes Building, IP Estate, New Delhi. 2) RMO Electrical and Mechanical services at MSO Building, I.P.Estate, New Delhi. (SH Replacement of outlived existing Emergency Panels).
2026_PWD_297123_1
79/EEEPWDDHC,NDC2026-27Recall
Open Tender
Electrical Works
Works
30 days
New Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹1.3 L
17 Aug 2026
17 Aug 2026
24 Aug 2026
17 Aug 2026
24 Aug 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SH: I (Emergency PANEL 4,5 & 6) Supplying, installation, testing & commissioning of cubical modular type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design having bus bar chamber duly fabricated from CRCA sheet steel of 2 mm thick for frame, back, sides, partition & doors and 3mm thick for glad plate duly powder coated in approved shade including cleaning & finishing complete with 7 tank process complete with 1600 Amp capacity extensible type four strip aluminium alloy bus bars of high conductivity, DMC/ SMC bus bar supports having short circuit withstand capacity of 31 MVA for '1' Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars, control wiring with 2.5 sq. mm. PVC insulated copper conductor single core cable, cooling / ventilation fans including construction of suitable CC foundation, in & out connections and providing & Fixing following switch gears therein etc. complete as required. a) Incoming (i) 3 Nos- 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB Port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date (ii) 3 Sets- RYB Phase indication LED lamps with 6A, 10KA, "C" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, "C" Curve backup MCB (iii) 3 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 1250/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, "C" Curve back up MCB. | |||||
| 1.01 | b) Bus Coupler
(i) 2 Nos - 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V with LSIG release, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc.
(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, "C" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, "C" Curve backup MCB
c) Interlocking
(i) Electrical interlocking through advance contacts in ACB's (all Incomers & Bus couplers) along with mechanical interlocking
d) Outgoing
(i) 2 Nos.- 1000 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date
(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, "C" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, "C" Curve backup MCB
(iii) 2 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 1000/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, "C" Curve back up MCB.
(ii) 5 Set- 630A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.
(iii)5 Set- 400A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.
(iv) 8 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.
(vi) 18 sets- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs along with ON/OFF indicating light with 6A, 10KA, "C" Curve backup MCB, auxiliary contacts with MCCB | 1 | nos. | 24,04,927 | ₹24,04,927 |
| 2SH: II (EMERGENCY PANEL 1 & 7) Supplying, installation, testing & commissioning of cubical modular type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design having bus bar chamber duly fabricated from CRCA sheet steel of 2 mm thick for frame, back, sides, partition & doors and 3mm thick for glad plate duly powder coated in approved shade including cleaning & finishing complete with 7 tank process complete with 1600 Amp capacity extensible type four strip aluminium alloy bus bars of high conductivity, DMC/ SMC bus bar supports having short circuit withstand capacity of 31 MVA for '1' Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars, control wiring with 2.5 sq. mm. PVC insulated copper conductor single core cable, cooling / ventilation fans including construction of suitable CC foundation, in & out connections and providing & Fixing following switch gears therein etc. complete as required. a) Incoming (i) 2 Nos- 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB Port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date (ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, "C" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, "C" Curve backup MCB (iii) 2 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 1250/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, "C" Curve back up MCB. | |||||
| 2.01 | b) Bus Coupler
(i) 1 Nos - 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V with LSIG release, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc.
(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, "C" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, "C" Curve backup MCB
c) Interlocking
(i) Electrical interlocking through advance contacts in ACB's (all Incomers & Bus couplers) along with mechanical interlocking
d) Outgoing
(i) 2 Nos.- 800 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date
(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, "C" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, "C" Curve backup MCB
(iii) 2 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 800/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, "C" Curve back up MCB.
(ii) 8 Set- 630A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.
(iii)8 Set- 400A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.
(iv) 6 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.
(v) 3 Set- 200A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.
(vi) 25 sets- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs along with ON/OFF indicating light with 6A, 10KA, "C" Curve backup MCB, auxiliary contacts with MCCB | 1 | Nos. | 22,16,564 | ₹22,16,564 |
| 3 | SH: III (EI Work)
1 ) Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. | 6 | Sets | 7,658 | ₹45,948 |
| 4 | 2) Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm | 50 | Meters | 160 | ₹8,000 |
| 5 | 3 ) Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | 50 | Meters | 755 | ₹37,750 |
| 6 | 4) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 100 | Meters | 287 | ₹28,700 |
| 7 | 5) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 100 | Meters | 84 | ₹8,400 |
| 8 | 6 ) Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on surface etc complete as required.
a) 3 X 10 Sq.mm | 50 | Meters | 361 | ₹18,050 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.86 MB
BOQ_395780.xls
BOQ • 0.39 MB
amendmentcorrigendum.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].