Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
22 Sept 2022, 1:00 pmClosed
MS Class C Chiller Water Piping
3676897
GEM/2022/B/2432706
80 NB, MS Class C pipes for supply and return chilled water piping to connect MEL AHU from KBAC pla
Unknown (Unspecified Location)
Total value wise evaluation
BOQ
4 documents required · 4 mandatory
Exempted
3 Jan 2023
26 Aug 2022
22 Sept 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | 80 NB, MS Class C pipes for supply and return chilled water piping to connect MEL AHU from KBAC plant chilled water header | SITC of 80 NB, MS Class C pipes for supply and return chilled water piping to connect MEL AHU from KBAC plant chilled water header as per the attached specification | 75 | Rmts | [email protected] | 240 |
| 2 | 100 NB, MS Class C pipes for LLMHD cooling tower bypass lines for Pot strainer installation | SITC of 100 NB, MS Class C pipes for LLMHD cooling tower bypass lines for Pot strainer installation as per the attached specification | 2 | Rmts | [email protected] | 240 |
| 3 | 200 NB, MS Class-C or equivalent pipes for KBAC cooling tower bypass lines for Pot-strainer installation | SITC of 200 NB, MS Class-C or equivalent pipes for KBAC cooling tower bypass lines for Pot-strainer installation as per the attached specification | 5 | Rmts | [email protected] | 240 |
| 4 | 100 NB, Class 150 Pot strainer for LLMHD Cooling Tower bypass line | SITC of 100 NB, Class 150 Pot strainer for LLMHD Cooling Tower bypass line as per the attached specification | 1 | Nos | [email protected] | 240 |
| 5 | 200 NB, Class 150 Pot strainer for KBAC Cooling Tower bypass lines | SITC of 200 NB, Class 150 Pot strainer for KBAC Cooling Tower bypass lines as per the attached specification | 2 | Nos | [email protected] | 240 |
| 6 | 80 NB, PN 10 Butterfly Valves with extended shaft for chilled water pipe lines | SITC of 80 NB, PN 10 Butterfly Valves with extended shaft for chilled water pipe lines as per the attached specification | 2 | Nos | [email protected] | 240 |
| 7 | 100 NB, PN 10 Butterfly Valves for LLMHD cooling tower bypass line | SITC of 100 NB, PN 10 Butterfly Valves for LLMHD cooling tower bypass line as per the attached specification | 1 | Nos | [email protected] | 240 |
| 8 | 200 NB, PN 10 Butterfly Valves for KBAC cooling tower bypass lines | SITC of 200 NB, PN 10 Butterfly Valves for KBAC cooling tower bypass lines as per the attached specification | 2 | Nos | [email protected] | 240 |
| 9 | 50 mm thick PUF thermal insulation on 80 NB MS chilled water piping with 26G Aluminium cladding | Supply and fixing of 50 mm thick PUF thermal insulation on 80 NB MS chilled water piping with 26G Aluminium cladding as per the attached specification | 75 | Rmts | [email protected] | 240 |
| 10 | 25 NB Class B, MS pipes for railing | Supply, fabrication and installation work of 25 NB Class B, MS pipes for railing as per the attached specification | 18 | Rmts | [email protected] | 240 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3676897.pdf
GEM_BID
final-tech-specs-with-drawings_04-08-2022_2022-08-11-15-40-32_046b070c93c98f2b09230ac059be7bf5.pdf
BOQ
boq_item_sample_22_23_155_2022-08-11-15-40-32_a8d38eb58ac3cd0a515f99c973f7c20e.csv
BOQ
Annexure_f5eab485-ad4f-42ca-a9471661253538629_nipen.nath@ipr.res.in.docx
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .