Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.1 L+₹166 (<0.01%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹22.2 L+₹1.1 L (5.12%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹22.3 L+₹1.2 L (5.47%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹25.8 L+₹4.7 L (22.4%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Jan 2020, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF METER PANELS MS SHEET METAL ENCLOSURE SUBMAIN WIRING DBS CONTROL SWITCH AND OTHER MISC WORKS AT MD ACCN OTM ACCN AT NAVAL STATION KARANJA
2019_MES_307353_1
8208/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE NW KARANJA
REPAIR REPLACEMENT OF METER PANELS MS SHEET METAL ENCLOSURE SUBMAIN WIRING DBS CONTROL SWITCH AND OTHER MISC WORKS AT MD ACCN OTM ACCN AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹60,000
Yes
4 Feb 2020
18 Dec 2019
15 Jan 2020
18 Dec 2019
14 Jan 2020
1 Jan 2020
18 Dec 2019 - 1 Jan 2020
Amount
Taking down carefully copper/aluminium point wiring( light, fan socket or powder)through steel / pvc conduit / casing caping (fitting such as switchs, ceiling croses , pendants regulators socket etc to be measured separately.) removing material to store for keeping in safe custody for reuse at site and making good disturbed surfaces of floor etc. all as specified and directed.
M & L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including PVC CASING CAPPING(ISI marked) with all accessories including surface / concealed sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor ( using green colour) to common earth and connecting to earth dolly, complete all as specified & directed for One light /fan/bell point controlled by one switch 5 Amp, SP, one way 240 volts.
As per item No 2 above but One 5 Amp, 3 Pin socket point on the same board .
As per item No 2 above but One 5 Amp, 3 Pin socket point independent
As per sl item No 2 above, but using 2.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable for phase & 1.5 sqmm PVC insulated unsheathed multistanderd copper conductor cable for earth continuity ( green colour) for one 3 pin socket outlet 15 Amp multi purpose independent controlled by 15 Amp switch, SP, one way, 240 Volts & socket, complete all as specified and directed.
As per sl item No 2 above, but using 4 sqmm (nominal area) for phase and 2.5 sqmm PVC multistanderd FRLS copper conductor cable for earth continuity ( green colour) for one 15 Amp socket point controlled by 15 Amp switch, SP, one way, 240 Volts & socket, complete all as specified and directed.
S & F switch piano flush button single pole one way 5 Amps (ISI marked ) Make : Anchor or equivalent complete all as specified and directed.
S & F for Buzzer AC 230 Volts singel pole (ISI marked) Make Anchor or equivalent complete all as specified and directed.
S & F for Bell push flush type 5 Amp (ISI marked) complete all as specified and directed.
S & F switch socket outlet 2-in-1, 3 pin 6 A controlled by one switch (ISI marked) Make Anchor or equivalent of Havells/Legrand complete all as specifed and directed.
S & F switch socket outlet 5-in-1, 15 A controlled by one switch (ISI marked) Make: Anchor or equivalent of Havells/Legrand or equivalent.
S & F ceiling rose surface bakelite 65 x 50 mm three terminals complete (IS marked) as per all as specified and directed.
S & F EME rotary step fan regulator suitable for operation in 230 V, AC, 50 Hz complete all as specified and directed
S & F Earth plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket 20A, 240 V with and including one MCB SP 20A, 240V or equivalent of Legrand/L&T/GE all as specified and directed.
S&F 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) all as specified and directed
S & F SPN MCB 240 V 50 Hz 10 KA confirming to IS 8828 of rating 6 to 40 Amp as per as in repairs all as specified and directed.
S & F TPN MCB 415 V 50 Hz 10 KA confirming to IS 8828 of rating40 TO 63 Amp all as specified and directed.
S & F 1.5 sqmm 3 core copper conductor cable, multistranded PVC insulated, PVC sheathed, unarmoured, cable for connecting HPMV lamp fittings complete all as specified.
M & L for submain wiring with 2 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper concuctor cable, 1100 Volts conforming to IS-694 1990 with ISI mark, drawn through and including existing PVC conduit 25 mm bore/ stove enamelled steel conduit 25 mm bore / PVC casing capping 25 mm size including one run of 4 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth contuinity and connecting up to common earth dolly complete all as specified and directed. Note:- Two run of 6 Sqmm and one run of 4 Sqmm earth wire will be measured as one running metre
M & L for submain wiring with 4 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper conductor cable, 1100 Volts grade conforming to IS-694 1990 with ISI mark, drawn through existing PVC conduit 25 mm bore/ stove enamelled steel conduit 25 mm bore / PVC casing capping 25 mm size including two run of 4 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth continuity and connecting up to common earth dolly complete all as specified and directed. Note:- Three runs of 6 sqmm cable, one run of 4 sqmm earth wire will be measured as one running metre
S & F MCB SPN distribution board sheet steel, phosphorised powder painted MCB DBs with busbar neutral link, earth bar and DIN rail conforming to IS, 4 way double door, 230 volts, 50 HZ, AC make Cat No. DHDNSNODRW 04 of M/s Havells or equivalent of Standard/legrand/HPL
As per item No 28 above but 8 way double door all as specified and directed by engr-in-charge.
S & F in MCB distribution board TPN, 4 ways, 415 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified. Make : Havells or equivalent of L&T/Legrand/HPL
As per item No 30 above 8 way double door.Make : Havells or equivalent of L&T/Legrand/HPL
S & F MCCB 3 Pole, thermal release range 63-80 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, Series all as specified and directed
S & F MCCB 3 pole, thermal release range 80-100 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, Series all as specified and directed
S & F MCCB 4 pole, thermal magnetic release range 63-80 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, Series complete all as specified Make: LEGRAND or equivalent of L&T & Simens
Supply and fix LED batten with 24W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver and including LED tube rod.as directed and specified by engr-in-charge.Make havells CT PT NO- LHEDAAP7PW1W024 or equivalent in CG/C&S
Supply and fix LED batten with 20W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with .as directed and specified by engr-in-charge.MakeBajaj BCLSB 20WH or equivalent in CG/C&S
Supply and fix LED batten with LED tube light in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified by engr-in-charge.Make C&S ct pt no-LTTB2F10WLED/W 10W 2 FT WHITE including LED tube rod or equivalent in CG/HAVELLS/bajaj
S & F LED tube rod 20 watt change with existing 36 watt tube rod complete all as specified and directed Make. HAVELLS ct pt no LHLDEFXD5L8R020 or equivalent of havells/bajaj.
M&L Checking of earth resistance and continuity in all married accomodation DBs and all points and checking of voltage differences in between earth and neutral points between phase and neutral /phase and earth also making Register and properly note down the value volts of initial and rectified value and also getting signature from engr-in charge will also includes in the job. NOTE:-checking should be carried out through Digital multi meter of reputed company of ISI marked and will get approved from engr-in-charge before commencing testing and the required sub main wiring and point wiring required for rectification will measured and paid under relevent item above all as specified and directed
Material and labour for enhancement of soil resistivity of earthing by Taking out pit cover and filling salt water through watering pipe of earth pit for improvement of earth resistance complete all as specified and directed by engr-in-charge.
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 45w IP 66 protection LED make bajaj ct pt no-169681 of EDGE Series
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection LED make bajaj ct pt no-169680 of EDGE Series or equivalent in havells/c&s
Supply and fix LED recess mounted 2x2 luminarie 36w fitting Make -bajaj ct pt no-111778 BZRSQL 36W GZWH or equivalent in havells,philips complete all as specified and directed by engr-in-charge.
S & F in repairs / replacement LED PL-L ultra bright lamp 18 watt as per Cat No PHOTONULTRAPLL419TL18WLED865SPC W complete all as specified and directed by Engineer-in-Charge.Make: Philips/wipro/Bajaj
S& F 'DURANTO' LED 100 watt Highbay luminaire complete fixing arragement fixed on ceiling with anchor incuding hanging arrangement as directed by Eng-in-Charge connecting up to 3 core multistranded copper conductor complete all as specified and directed including taking down of existing fitting .Make/Model: Bajaj BGHB 100W LED, Code No. 169710 or equivalent of Philips/wipro.
Supply and fix LT PANEL consisting space to fix TPN DB and 8 nos meter and providing 8 nos MCB DP 40 with enclosure for protection of METER . single door fixed type wall mounted PTTA A DLEC model CRCA sheet enclousure .The rates including taking down old meter and connecting in new panel with required wires with out any extra cost complete all as specified and directed.The panel should cosists of the following :-INCOMING (1) MCCB 63 AMP 4 P 25 Ka thermal magnetic based with o/c,s/c protection & ROH -01 nos (2) Indicating lamps RYB-03nos(3) 6 amp MCB sp-03 nos. OUT GOING :(1) 40 amp MCB DP 10 ka with enclosure-08nos.(2)Space for refixing existing electrical meter -09 nos .MCB sp 6amp-01 nos.NOTE-Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed by Engr-in-charge
Supply and fix wall light fitting of make havells ct no-LHFHCHE1TL1W020 including 10w LED lamp or equivalent in C&S or Bajaj complete all as specified and directed by engr-in-charge.
M/s S.D Construction Co
D.N.PATIL
Om Sai Enterprises
JAVEED TRADERS
somnath engineering corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .