Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 0 JANAI JANAI CHANDITALA HOOGHLY WEST BENGAL 712304 UDYAM WB 07 0059321 | HOOGHLY | WEST BENGAL | 712304 | ₹31.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹31.5 LRejected-Finance 1 71 SREEMANTA DEY LANE KOLKATA 700012 W B | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹31.5 L | L2 | Rejected-Finance Rejected |
| 3 | L3₹31.6 LRejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | ₹31.6 L | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | ORIENTAL ENGINEERING CO. L2 | WEST BENGAL ENGINEERING CO. L3 | DAS ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Operation, maintenance and guarding of installed pumping machineries as Raw water Intake pumps, Clear water pumps Group – I and II, Back washing pumps including all gadgets and electrical installations control panel, MCC, incomers capacitor banks etc for above pumping machineries, entire yard and indoor lighting at plant and intake along with operation of all associated valves “round the clock” on as and when required basis by engaging 7(seven) nos operating personnelas per direction of EIC. | 365 | /day | 4,355 ₹15.9 L | 4,357 ₹15.9 L | 4,353 ₹15.9 L |
| 2.00 | Labour charges for 4 (four) no. operating personnel ffor operation and guarding of 11/0.433 KV, 2 X 500 KVA subnstation equipments with manual operation system including operation of battery charging arrangement, internal/external illumination with all accessories | 365 | /day | 2,489 ₹9.1 L | 2,490 ₹9.1 L | 2,488 ₹9.1 L |
| 3.00 | ESIC Contribution of Empleyers | 365 | /day | 174.13 ₹63,557.45 | 174.13 ₹63,557.45 | 174.13 ₹63,557.45 |
| 4.00 | EPF Contribution of Empleyers | 365 | /day | 696.41 ₹2.5 L | 696.41 ₹2.5 L | 696.41 ₹2.5 L |
| 5.00 | Servicing, Testing and Calibration of different relays and breakers as installed for smooth operation of the sub-station by any testing agency approved by directorate of electricity or WBSEDCL aas directed EIC and as per specification ( Twice in a year , 6 months interval) | 2 | L.S | 49,392 ₹98,784 | 49,416 ₹98,832 | 49,368 ₹98,736 |
| 6.00 | Supervision charges for electrical installation at Sub-Station equipments by licensed electrician having requisite parts as per IE rules 1956 with latest amendments and overhead expenditures for the above period. | 12 | /Day | 8,683 ₹1.0 L | 8,687 ₹1.0 L | 8,678 ₹1.0 L |
| 7.00 | Supervision charges for electrical installation at HL and LL pump house by licensed electrician having requisite parts as per IE rules 1956 with latest amendments and overhead expenditures for the above period. | 12 | /month | 8,683 ₹1.0 L | 8,687 ₹1.0 L | 8,678 ₹1.0 L |
| 8.00 | Add: 1% Cess | 1 | L.S | 31,229.83 ₹31,229.83 | 31,242.22 ₹31,242.22 | 31,217.2 ₹31,217.20 |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
3 Feb 2026, 6:00 pmClosed
Executive Engineer, BMD, PHED
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Operation maintenance and guarding of pumping machineries and sub-station at treatment plant site of Mukutmanipur Old Head works (and intake) Water Supply Scheme under Bankura Mechanical Division, P.H.E. Dte.
2025_PHED_981198_124
WBPHED/EE/BMD/NIeT-21 OF 2025-2026
Open Tender
MECHANICAL
365 days
Bankura
Please refer Tender documents.
6 documents required · 6 mandatory
₹64,000
Yes
14 May 2026
16 Jan 2026
6 Feb 2026
16 Jan 2026
3 Feb 2026
16 Jan 2026
Operation, maintenance and guarding of installed pumping machineries as Raw water Intake pumps, Clear water pumps Group – I and II, Back washing pumps including all gadgets and electrical installations control panel, MCC, incomers capacitor banks etc for above pumping machineries, entire yard and indoor lighting at plant and intake along with operation of all associated valves “round the clock” on as and when required basis by engaging 7(seven) nos operating personnelas per direction of EIC.
Labour charges for 4 (four) no. operating personnel ffor operation and guarding of 11/0.433 KV, 2 X 500 KVA subnstation equipments with manual operation system including operation of battery charging arrangement, internal/external illumination with all accessories
ESIC Contribution of Empleyers
EPF Contribution of Empleyers
Servicing, Testing and Calibration of different relays and breakers as installed for smooth operation of the sub-station by any testing agency approved by directorate of electricity or WBSEDCL aas directed EIC and as per specification ( Twice in a year , 6 months interval)
Supervision charges for electrical installation at Sub-Station equipments by licensed electrician having requisite parts as per IE rules 1956 with latest amendments and overhead expenditures for the above period.
Supervision charges for electrical installation at HL and LL pump house by licensed electrician having requisite parts as per IE rules 1956 with latest amendments and overhead expenditures for the above period.
Add: 1% Cess
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
Tendernotice_2.pdf
PDF • 0.11 MB
Tendernotice_3.pdf
PDF • 17.35 MB
BOQ_2411860.xls
BOQ • 0.34 MB
Specificationsubstation.pdf
Tender Documents • 1.50 MB
Download all tender documents and submit your bid