Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.5 L+₹89,130 (4.12%)Rejected-Finance | L2 | Rejected-Finance Not being Lowest | |
| 3 | L3₹23.7 L+₹2.1 L (9.66%)Rejected-Finance | L3 | Rejected-Finance Not being Lowest | |
| 4 | L4₹24.7 L+₹3.1 L (14.3%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L4 | Rejected-Finance Not being Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
2 Oct 2024, 6:00 pmClosed
GARRISON ENGINEER I Rnd D WEST BANGALORE
GARRISON ENGINEER I RndD WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
REPAIRS REPLACEMENT AND MAINTENANCE OF ELECTRIC SUPPLY AND WATER SUPPLY INSTALLATIONS INTERNAL ELECTRIFICATION TRANSFORMER OIL FILTERATION AND SERVICING OF VCBs ACBs AT MTRDC RESIDENTIAL AREA AT BENGALURU
2024_MES_670492_1
GE(I)/R ND D (WEST)/BAN/TOKEN/73 OF 2024-25 8331/E8
Open Tender
Civil Works
Item Rate
180 days
Work
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I Rnd D WEST BANGALORE
₹60,000
12 Dec 2024
3 Sept 2024
8 Oct 2024
4 Sept 2024
2 Oct 2024
19 Sept 2024
4 Sept 2024 - 18 Sept 2024
Amount
Supply fix modular type switch 1-module 5/6 Amps, AC, 230 volts, Make: Anchor-Roma / indo asian,/ havells.
Supply and fix modular type switch 1-module 15/16 Amps, AC, 230 volts, Make:-Anchor-Roma / indo asian,/ havells.
Supply and fix modular type socket 5/ 6 Amps 2/3 pin compained 2-module 230 volts AC, ISI marked for inserting 2 pin / 3 pin plug top all as specified. Make: Anchor-Roma / indo asian.
Supply and fix modular type socket 16 Amps 3/3 pin compained 2-module 240 volts AC ISI marked for inserting 3 pin 6A / 3 pin 15A plug top all as specified Make: Anchor-Roma / indo asian.
S&F fan regulator electronic modular type 230 Volts 2-module,stepped type 120 Watts including dismantling old regulators.
S&F bell push modular type 1-module 5/6 Amps 240 volts AC Make:-Anchor/indo asian.
S& F electric calling bell ,single phase 240 Volts 50 HZ AC complete. Make: -Anchor/Cona
Supply only in replacement louver for exhaust fan, any size as per requirement at site,fixing flush with the wall including taking down the old existing all specified and direted
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 1.5 sq.mm size, FRLS Grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 2.5 sq.mm size, FRLS Grade, complete all as specified and directed.
Supply only fan regulator electronic 2 module type type 230 Volt stepped type,including taking down of old regulator complete all as specified.
Supply only wall mounted battern type LED light fitting 20 Watt 4 ft with high lumen output, environmental friendly, energy efficient,with accessories,IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, complete with diffuser,integrated electronic driver 20 W including taking down old UNSV FTL fittings. all as specified and directed.
All as per item 12 here in before but for 10 Watt 2 ft ,and all as specified and directed.
Supply only MCCB Three Pole, 63 Amps, 16 KA breaking capacity, 415Volts 50 Hz all as specified.
Supply only MCCB Three Pole, 100 Amps, 16 KA breaking capacity, 415Volts 50 Hz all as specified.
Supply only MCCB three Pole, 200 Amps, 35/36 KA breaking capacity, 415Volts 50 Hz all as specified.
Supply only MCB TPN, 415 V, 63 A current rating, 'C' series, 10 KA breaking capacity complete all as specified and directed.
Supply only outdoor type LED as power source post of lantern light fitting of 15 watts energy saving enviromental friendlyycomprising of epoxy powder coated hsg, enclosed with glass cover in frame , with protection complete with all accessories and lamp colour white and fixing all as specified and directed .
Supply and fix in replacement post top lantern LED type 40 watt conical in shape 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specied and directed.
Supply only outdoor type LED street light fitting of 70 Watts comprising of epoxy powder coated hsg, enclosed with glass cover in frame with protection IP-65 complete with all accessories and lamp colour white and fixing complete all as specified and directed, Make
Supply only LED flood light 150Watt highly efficient LED flood light made of pressure die cast alluminium housing , suitable lens and toughened glass IP 66 capacity with best in class design & Robust heat sink along with class leading IP, IK & Surge protections for long lasting performance. Cat No HLFLD-ML15-150-CWL-R-B
Supply only heavy duty capacitor for linear load 415 Volts, 50 Hz of 25 KVAR capacity suitable for capacitor banks all as directed.
Supply and lay cable XLPE insulated armoured LT cable 1100 volts grade of size 10 Sqmm 2 core, in tenches / on walls /poles, including suitable cable lugs, MS clamps for fixing, connecting ,testing and commissioning including taking down the exisitng unserviceable cable complete all as specified and as directed. NOTES :- Earthwork, sand filling, brick protection, shall be measured and paid separately under relevant items of this schedule.
All as per item 23 here in before but cable size 35 sqmm 3.5 core
S&F Heavy duty automatic Star-Delta strater type ML1.5 FSLD of L&T make for pumpset 10 hp,made of mild steel enclosure factory made, comprising of the following items contractor,over load relay, phase seqence, of 3-phase in put voltage 415 Votls 50 HZ, current relay range 13-21 Amps complete all as specified and directed.
Preparing old painted surface of steel tubular poles 8.5 to 9 metres long and painting with two coats of Aluminium paint including white washing the coping portion above ground level all as specified and as directed.
GI tubing of 80 mm dia light grade for protection of cable at road crossing/drain/floor/pole including necessary clamps made out of MS flat iron of size 25 x 5mm bolts, nuts, washers etc including taking down old GI pipe all specified and directed.
Material and labour for detection of any type of fault in HT underground Line of any size and core. (laid in soil at plane area or forest area) with the help of HT Meggar. Seggregation of faulty span by meggering and making span serviceable by repair of cable or replacement of cable. Note : 1. Detection of one fault in faulty span will be measured as Each Job. 2. Earth work and taking out will be measured seperately. 3. Material for repair and replacement will be measured saperately.
Supply and fix in repairs Silica Gel Breather assembly complete duly filled with silica gel stones suitable for transformer of capacity 150 -250 KVA complete all as specified and as directed.
Topping up of Transformer oil ISI marked duly tested proper die-electric strength up to desired level after heating up oil suitable for 11 KV system .
Dehydration of Transformer oil at site using dehydration machine through on line filteration to withstand die-electric strength of 50 KV for 1 minute at 2.5 mm gap complete all as specified and as directed .
Servicing and Painting of two/four pole structure consisiting of poles, rolled steel joists mild steel channels & supports with one coat of aluminium paint including colour code for RYB to indicate the colour code for body earthing & lighting arrestor complete including taking proper shut down & greasing the GOD switch & tightening of all bolts & nuts and replacement of ACSR conductor and PVC sleeves , wornout lugs, PG clamps and HT fuses in the structure as required at site including two coats of white wash for masonary plat form complete one coat of synthetic enamal paint for weld mesh, removing of Weeds / Plants inside the yard and Cleaning complete all as specified and as directed.
Servicing of Transformer by dismantling the top cover, checking of HT/LT bushings from core winding cleaning/ removing the sludge from the transformer tank, cleaning in side the radiator and core winding, cleaning the radiator coil including checking the connections of protective devices like winding, temperature indicators, replacing the top cover gaskets & washers with new one and charging of the transformer, ensuring no oil leakage from transformer including painting of transformer with grey colour enamel paint and testing and commissiong to system complete all as specified and directed by the Engineer-in-Charge of 200 KVA capacity:
Three Phase non-linear type lightning arrestor suitable for three wire 11KV overhead lines complete with galvonised clamping arrangement GI bolts, nuts and washers complete including taking down old arrestor all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mmx 6.30 mm thick burried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m deep below normal ground level connected to galvanised earth wire 4 mm dia, 7.5m length by means nuts, check nuts and washers of GI or steel connected to main switch board including watering arrangement with PCC chamber MS wire gauge, CI cover with frame incl excavation in any strata and returning, filling, removal surplus soil, charcoal salt complete all as shown in electric plate No 3 of SSR Part I (Earth test point shall be provided at suitable point) including taking out the old Earthing materials complete all as specified and as directed.
Disconnecting the burnt cable end terminals at incoming side of MCCB DB TPN/cubicle and cutting suitable length of Incoming LT UG cable after breaking PCC on wall / floor, taking out cable from loop by excavation and earthwork complete of any size and type crimping aluminium lugs of suitable size after preparation of cable ends and connecting back including providing GI taking out nuts, bolts, washers and testing for any loose connections making good disturbed surfaces complete all as specified and directed.
M&L Cable joining kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 95 sqmm
Supply and fixing FRP loop in loop out boxes of size not less than 250 mm x 200 mm x 105 mm out door type duly fitted on bottom of steel tubular poles with suitable size clamps, bolts, nuts and washers complete with 2 No 4 way connector 32 amps heavy duty, and clamps made out of FI 20 x 5 mm and MS nuts, bolts etc all as per Cat No GSJB 2520 of SYNTEX or techno commercial equivalent of HENSEL/ HPL including taking out the exisitng unserviceable loop boxes complete alongwith electrical connections as required at site all as specifed and as directed.
Material and Labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and as directed.
Sub main wiring with 2 single core, 4 Sqmm FRLS PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x 4 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed.
Sub main wiring with 2 single core, 6 Sqmm FRLS PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x 6 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed.
S&F Heavy duty automatic Star-Delta strater type ML1.5 FSLD of L&T make for pumpset 10 hp,made of mild steel enclosure factory made, comprising of the following items contractor,over load relay, phase seqence, of 3-phase in put voltage 415 Votls 50 HZ, current relay range 13-21 Amps complete all as specified and directed.
S & F LED ceiling mounted recessed full lite luminaire with glare free uniform illumination 36 W 2X2 ft (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,THD<10%, CCT 5700K, CRI >= 80 and Driver Should be Constant Currnet LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge MAKE:- HAVELLS Cat No.PLANOSURFACE2x2PLS36WLED 857S or techno equalent in philips// Wipro Havells Osram/Bajaj/ CG as approved by GE.
All as per Sl item No- 43, LED flat panal,36 Watt, 2X 2 feet,for suface mounting, soft light glare free symmetrical illumination.MAKE:- HAVELLS Cat No.PLANOSUR2x2 PLS36W LED857S0720 or techno equ in philips/Havells/Osram/ Wipro/Bajaj/CG as approved by GE.
Servicing of HT VCB's , Capacity 630/800 Amps complete with micro processor relay by with drawing VCB's from cabinet compartment including cleaning, greasing of all moving parts, tightening of bolt &nuts and removing carbon deposits & sludge including adjusting spring tensions, tightening all cable interconnections, blowing hot air to remove moisture content from the unit compartment, including re fixing, testing & commissioning complete all as specified and as directed.
Calibration of Relays of HT 11 KV VCB/OCB through primary and secondary injection method including testing complete relay like relays / instantaneous earth fault relay panel complete all as specified and as directed.
Servicing of LT ACB's , Capacity 630/800 Amps complete with micro processor relay by with drawing ACB from cabinet compartment including cleaning, greasing of all moving parts, tightening of bolt &nuts and removing carbon deposits & sludge including adjusting spring tensions, tightening all cable interconnections, blowing hot air to remove moisture content from the unit compartment, including re fixing, testing & commissioning complete all as specified and as directed.
Supply and replacement of Auxillary contact 10 A capacity suitable for ACB 630/800 Amps with 2NO + 2NC coil voltage 220 V, AC,50 HZ .complete with all accessories and as directed. Make:L&T/GEC/CC
Supply and replacement of Shunt Coil Relay suitable for ACB 630 A to 800 A 3 phase,415 Volt 50 Hz . Make : L&T/GEC/Alsthom
Supply and replacement of Under Voltage Relay suitable for ACB 630 A to 800 Amps ,3 phase ,415 Volt 50 Hz . Make : L&T/GEC/Alsthom
Supply and replacement of Earth Fault Relay suitable for ACB 630 A to 800 Amps, 3 phase,415 Volt 50 Hz . Make : L&T/GEC/Alsthom
Supply and lay cable XLPE insulated armoured HT cable 11000 volts grade of size 120 sqmm 3 core, in tenches / on walls /poles including suitable MS clamps for fixing, connecting , testing and commissioning including taking down the exisitng unserviceable cable complete all as specified and as directed. NOTES :- Cable shall be lay through ground, Duct or wall by clamping.
M&L Cable joining kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm
Excavation in trenches in hard/dense soil not exc 1.5 metre wide not exc 1.5 metre in depth; for laying of cables not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out , trimming sides, forming bottom surface to required level complete all as specified and as directed .
Returning filling including spreading, levelling , watering and well ramming in layers n.exc 25cm in soil as directed .
Removing of excavated soil to a distance not exc 50 m & depositing where as directed at a level n.exc 1.5m above starting point all as specified and as directed.
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
Sub-class 'B' well burnt bricks of old size 230 mm x 115 mm x 40 mm laid breadth wise along the length of cable laid in trenches for UG cable protection all as specified and as directed.
Painting to steel surfaces of VCB,s, LT panel boards or feeder piller boxes or any other plants as directed externally of any description and size, over 10cm in width or girth, not otherwise described using exsisting colour of Synthetic enamel paint one coat after necessary cleaning of surfaces duly disconnecting the power supply under intimation to site incharge complete all as directed.
Material and labour for detection of any type of fault in LT/HT underground Line of any size and core. (laid in soil at plane area or forest area) with the help of HT Meggar. Seggregation of faulty span by meggering and making span serviceable by repair of cable or replacement of cable. Note : 1. Detection of one fault in faulty span will be measured as Each Job. 2. Earth work and taking out will be measured seperately. 3. Material for repair and replacement will be measured saperately.
Supply and fix in replacement of U/S relay any type and make with Numerical relay microprocesser based model including retrofiting to the existing panels and programming the relays for overlaod and earthfault setting with respect to trip settings of HT panels Sub station or other sub station insuch a way that fault are arrested locally the tip testing carry over suitable with 66KV sub station/other complete all as specified and directed.
H S S ENGINEERS AND CONTRACTORS (BID ID -3112355)
Arunachaleswara enterprises (BID ID -3113219)
GS TRADERS (BID ID -3113011)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .