Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹21.8 L+₹13,412 (0.62%)Rejected-AOC | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹21.9 L+₹16,796 (0.77%)Rejected-Finance SAINTHIA BIRBHUM | SAINTHIA | BIRBHUM | WEST BENGAL | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹21.9 L+₹23,728 (1.09%)Rejected-Finance INDIRA HATIA BIRBHUM | BIRBHUM | WEST BENGAL | L4 | Rejected-Finance Being L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹43,889
Closing Date
8 Sept 2025, 1:00 pmClosed
Executive Engineer, Birbhum Electrical DivisionPWD
Ofc The EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P O Suri,Dist Birbhum, Pin 731101
Repair and Renovation of Electrical installation work including Compound Light, Lightning Conductor arrangement and Glow Sign Board at Govt Model School, Md.Bazar, Birbhum, Project ID ES252638021S000.
2025_WBPWD_893245_1
BIRED/16/e-NIQ(1st call) of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Suri
Please refer Tender documents.
4 documents required · 4 mandatory
₹43,889
Executive Engineer, Birbhum Electrical DivisionPWD
6 Jan 2026
21 Aug 2025
10 Sept 2025
21 Aug 2025
8 Sept 2025
25 Aug 2025
25 Aug 2025
Amount
SUB-HEAD 1--DISTRIBUTION WIRING, Cutting Channel Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand Polycab/ Finolex/ RR/ Gloster or as per choice of EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC) fixed on Modular GI switch boardwith top cover plate and 2 no. suitable size “Ph & N” copperbar & earthing attachment fixed on wall incl. mending gooddamages to original finish. Average run 8 Mtr. [1(b)/E-24]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/ Finolex/ RR/ Gloster or as per choice of EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. i) On board. [3(i)/E-20]
ii) Average run 3 Mtr.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand Polycab/ Finolex/ RR/ Gloster or as per choice of EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. i) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
ii) 2 x (2.5 sqmm) + 1 x (1.5 sqmm) [ 1(a) ii / E-14]
iii) 2 x (4 sqmm) + 1 x (2.5 sqmm) [ 1(a) ii / E-14]
iii) 2x(6 sqmm) + 1x(4 sqmm) as ECC [ 1(IV) /E- 14]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 1.5 sq.mm. [NS]
b) 2.5 sq mm [9(i) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 100 x 100 x 65 [11(a)/E-4]
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws 100 x 100 x 65 [13(a)/E-5]
SUB-HEAD 3--PDB,SPNDB, Mainswitch ETC Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (For Mid Day Meal) 63A (on angle iron frame) [ Make-L&Tor similar specification as per approved by EIC ]
Supplying and fixing Sheet steel Main Switcheson flat iron frame on wall 240V DP with fuse on L&N 30/32 A [1(a)/D-1]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (For Mid Day Meal) 6 Way [ Make-Legrand or similar specification as per approved byEIC ] [ 14 / D- 10 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. (For Mid Day Meal) 2+8 Way [ Make-Legrand or similar specification as per approved by EIC ] [ 13 / D- 9 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] i) 63 A FP [ 6 / D- 5 ]
ii) 40 A DP [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP [ 7 / D- 6]
Supply & Fixing of 3 nos 200A Kit-Kat fuse set with Neutral link connection fixed on back light board having size of 1'6" x 2'6". [NS]
SUB-HEAD 4--PLUGS, SOCKETS DB. Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[9(b)/E-18]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [9(a)/E-18]
Supply & Fixing 240 V, 1 no 16A & 1no 6A Modular type plug socket (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC) with separate 1 no16A & 1 no 6A Modular type switch (Brand approved by EIC) on 6 Module Modular type switch board incl. S & F of switch board concealed in wall and top cover and making necessary connections with PVC Cu wire and earth continuity wire etc as required. [NS] (For water purifier)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. [12/E-18]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 6 Module [1(b)E-17]
Supply & Fixing 240 V 6 A Modular type switch (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. [3(a)E-17]
Supply&Fixing 240V, 6A, 5 pin Modular typeplug socket (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC),without switch&plug top, onexistingGIModular type switch board with top cover plate and making necy. Connections with PVC cu wire and earth continuity wire etc. [4(a)/E-17]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand North-West/ LK/Crabtree or as per choice of EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/E-19]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 5(a) / E-17]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug top with indicator (Brand Anchor / LK / Crabtree or as per choice of EIC) & necy. Connections. [5(b) / E-17]
SUB-HEAD 5-- SUPPLY & LAYING OF CABLES Supply & delivary of 1.1KV grade 4 core 95 sq. mm. multy stranded alluminium conductor Armoured cable. [from Substation building Tto security light] [Make- RR/Gloster/ Havells / Polycab/ KEI / As per choice of EIC]. (To main panel)
Supply & delivary of 1.1KV grade 4 core 25 sq. mm. multy stranded alluminium conductor Armoured cable. [from Substation building Tto security light] [Make- RR/Gloster/ Havells / Polycab/ KEI / As per choice of EIC]. (To TPNDB)
Supply & delivary of 1.1KV grade 4 core 10 sq. mm. multy stranded alluminium conductor Armoured cable. [from Substation building Tto security light] [Make- RR/Gloster/ Havells / Polycab/ KEI / As per choice of EIC]. (To Street light)
Supply & delivary of 1.1KV grade 3 core 10 sq. mm. multy stranded alluminium conductor Armoured cable. [from Substation building Tto security light] [Make- RR/Gloster/ Havells / Polycab/ KEI / As per choice of EIC]. (To SPNDB)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables . 4 Core 95 Sq. mm [7(c)/F-4 ]
4 Core 35 Sq. mm [7(c)/F-4 ]
4 cor 10 Sq. mm [7(c)/F-4 ]
3 cor 10 Sq. mm [7(c)/F-4 ]
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 4 Core 95 Sq. mm
4 Core 35 Sq. mm
4 cor 10 Sq. mm
3 cor 10 Sq. mm
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. [ 4(a)/ F- 2 ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 40 mm dia. [11(c)/F-6]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. [ 1(a)/ F- 2 ]
Laying of cable as below, after cutting floor /pavement / wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Incl. following size GI [Hot Dip] Wire as Earthing as per GS. [5(i)/F-3 & 118/K-3] From 2.5 sqmm to 35 sqmm incl earthing attachment in 2x 10 SWG GI [Hot Dip] Wire.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. [ [ 2(b)/ F- 1 ]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core. [3(a)/F-1]
SUB-HEAD 6--ERECTION & INSTALLATION OF STEEL TUBULAR POLE Supply of 6 MTRS GI OCTAGONAL POLE FABRICATED PART AS PER DIMENSION :T0P DIA - 70 mm, BOTTOM DIA -130 mm, (SECTION LENGTH - 6000 mm) THICKNESS - 3 mm,BASE PLATE -220 mm x 220 mm x 12 mm. incl. FOUNDATION BOLT - M20 x 600 mm x 4 nos 'J' type bolts and terminal junction box with 6A SP mcb protection with all accessories including nut, bolt, socket, proper wiring etc. incl. Supply and fixing of 1.5 M long Single arm bracket (Make– Utkarsh/Bajal/ Valmont/ Transrail as per choice of EIC) (With testing certificate)
Supply and fixing of 1.5 M Hot Dip Galvanized mini Pole with Top Dia. (A/F) 50 mm and 70 mm Bottom Dia. (A/F) mm. Thickness of the sheet is 3 mm. Base Plate Dimension (LxWxT) 200x200x8 mm. The pole has 4-M16 Foundation Bolt including 40mm dia 1.5 mtrs. GI Single arm bracket with fixing arrangement & necy. connection etc. (Make: Transrail or similar specification of Utkarsh/ Bajaj/ Bansal/ Jindal/ Volmount or as per choice of EIC)
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary. (a) Without Loop Box [13(A)/I-1 ]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed / projected from the wall of the building incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [C-3/20/b]
Supplying & Fixing PVC waterproof type looping cable box (SINTEX/Hansel As per direction of EIC) size minimum 200x150x100 mm deep comprising of one 240V,10A MCB(legrand make), housing the mcb, one NL on porcelain insulator, two provision of compression type brass cable gland for upto 4- core 16 sqmm PVC/A cable and having lined with rubber gasketted top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole, including S&F 40x6 mm thick, suitable "C" type 4mm thick MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [NS] (1 no for pole and 1 no for glow sign board)
Construction of suitable Shallow foundation for 6mtr/ 4mtr. Octagonal Pole with M -20 grade concrete for Pole considering soil bearing capacity (SBC) 10T/sq. mtr. at 2 Mtr. depth with all materials and labour payment made as per PWD civil schedule & as per direction of EIC. Erection of Pole by using of lifting equipment like hydra etc. and fixing of foundation bolts , anchor plate etc. with necessary arrangement & Testing & commissioning of all electrical equipment of Pole like led fixtures, MCBs Terminal etc. with cable entry/exit pipe and necessary connection. [NS]
Painting of Steel Tubular Pole and mini Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/ emery paper, cleaning etc. for receiving fresh coat of paint. [Upto 9.0 mtr. long pole] One coat of red lead/Zinc chromate priming.[7A(a)(i) /H-2]
1st coat of synthetic enamel paint over the primer
2nd coat of synthetic enamel paint over the 1st coat
Supply & Fixing of suitable size angle iron stracture with nuts, bolts and other accessories for fixing of LED Flood Light.
Sub Head-5-- OUTDOOR light Fittings Supply & Delivery of 240V, 120 W LED street light (for mini pole) with system output of 140 lm/W, CCT-5700K, CRI-70, SDCM<5,THD <=10% at full load, in build SPD 4KV, Aluminium PDC housing with integrated lens cover that complies with IP66 protection. luminarie complete with all accessories (Make- Philips (BRP503 LED168 CW R3C PSU S1)/ or equivalent model of Havells/Wipro/ Crompton or as per choice of EIC) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (with 5yrs warranty)
Supply & Delivery of 240V, 90 W LED street light with system output of 140 lm/W, CCT-5700K, CRI-70, SDCM<5,THD <=10% at full load, in build SPD 4KV, Aluminium PDC housing with integrated lens cover that complies with IP66 protection. luminarie complete with all accessories on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (Make- Philips (BRP502 LED126 CW R3C PSU S1) or equivalent model of Wipro/Havells/Crompton or as per choice of EIC) (with 5yrs warranty)
Supply & Delivery of 240V, 150 W with system output of 120 lm/W, CCT-5700K, CRI-70, SDCM<5,THD <=10% at full load, in build SPD 4KV, LED Flood light light. (Make- Philips (BVP283 LED181 CW FG SY5WB 150W V1) or equivalent model of Wipro/Havells Crompton or as per choice of EIC).(with 5yrs warranty)
Supply & Fixing of 240V, 45 W LED for street light with system output of 120 lm/W, CCT-5700K, CRI-70, SDCM<5,THD <=10% at full load, in build SPD 4KV, Aluminium PDC housing with integrated lens cover that complies with IP66 protection. luminarie complete with all accessories (Make- Philips (BRP331 LED54 CW R5N PC PSU S1 V1)/ Wipro/Havells/Crompton or as per choice of EIC) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (with 5yrs warranty)
Supply & FixingTimer DB for intermittent operation of Compound Lights Consisting of following accessories : 1) Double Door IP30-IK08 DB-2+14way SPNDB Enclosure (Make- L&T, cat no.-DBSPN016DD) - 1 No, 2) 32Amp FP MCB (Make- L&T, cat no.- BB40320C)-1 no 3) Digital Time Switch (Make- L&T, cat no.- 67DDT0)- 1 No, 4) 32Amp 3pole modular power contactor (Make- L&T )- 1 no, 5)Toggle switch (Reputed make)-1 no, 6) Indicator lamp-3, 7) Necessary wiring & socketing of all.
SUB HEAD 12-- Glow Sign Board SITC of LED illumination sign board fabricated by 12’×4’ (ft) × 5” (inch) depth ACP box supported with 1’×1’ MS hollow square pipe of 18 swg all around. The 3 mm ACP facial should be provided with Laser cutting 6 mm thick acrylic letters out of which 3 mm rising from the surface of the ACP board. 6 mm letters should be fixed on another 3 mm acrylic sheet on back side of the ACP facial. Border line of the front portion and back portion should be covered by 1.5” Aluminum channel as per the direction of EIC. The sign board should be glow from back side of letters by 1.5W/2.0 LED 2/ 3 / 4 module cool white in colour including 12V 615W power supply and LED must be covered in box made of 3 mm thick sun board. 4” with part of the four side of board should be covered by ACP after bending excess part from front side. The sign board should be fixed on roof of the building with suitable supporting arrangement on floor and mending good damages as per direction of EIC. Colour of APC & letter will be as per direction of EIC. The cost of transportation and scaffolding charges are included. The sign board should be as per the following inscription as per direction of EIC – Probably to be provided (I) national emblem. (II) State logo. etc. beside these the probable. matter would be as follows as per authority approval:-
Supply & delivery of MS Angle Iron structure to frame the fabrication structure for 12'x4'x5" glow sign board as per direction of EIC
Fabrication & installation of support structure for glow sigh board as follows: 4 nos. 50x50x6 mm MS angle iron of length 14 ft to be fixed on each column of the gate by drilling the column & fixing by MS flush nuts including making Zig-Zag shape of the angle iron structure with 40x40x5 mm MS angle, the two structures over the columns of the gate are to be joined by 50x50x6 mm MS Angle of suitable size by welding/ making drills & nut-bolts etc. on top & bottom of the glow sigh board including fixing the glow sigh board on it as per direction of EIC.
SUB-HEAD 7--FIXING OF LIGHT FITTINGS. Fixing only lamp [11/C-2]
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc [14(a)/C-2]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [17/C-2]
SUB-HEAD 8--SUPPLY OF INTERNAL LIGHT FITTINGS. Supply of single/double fitting of suitable for 4 Ft. 20/22Watt single/ twin florescent for indoor application,complete with all accessories & Lamps having following Model / Cat No. as per direction of EIC Single fittings (Make -Philips-TMC502 1xT-LED 22W/ Similar model of crompton/Havells wipro or as per choice of EIC). [NS]
Double fittings (Make -Philips-TMC502 2xT-LED 22W/ Similar model of crompton/Havells/wipro or as per choice of EIC). [NS]
Supply of 4 Ft. 20 Watt single/twin LED light for indoor application, having following Model / Cat No. ( Make- Philips-Cat No.- Mas LED Tube 18W865 T8I-2100lm/Similar model of Havells/Crompton/Wipro or as per choice of EIC) [NS]
Supply of 9W LED bulb (Magik/ Bajaj/ CG/ Philips/ wipro) on existing batten holder
SUB-HEAD 9 -- FIXING OF FANS Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand Anchor Roma/ Legrand Mylinc/ Crabtree or as per choice of EIC) on existing Modular GI switch board as per GS. [10/E-18]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [21(a)/C-3]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter. 30cm (12") [ 28(b)/C-4 ] .
Fixing only exhaust fan. 23cm (9")
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x62 mm long). 23cm (9")
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [22/D-3]
SUB-HEAD 10--SUPPLY OF FANS. Supply of 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS (Make - Crompton HS /Usha striker PWD or similar specification of Orient or as per choice of EIC). (with 2yrs warranty)
Supply of 240 Volt, 450 mm, 4 blade Full metal body Wall type braket fan complete with all accessories. as per direction of EIC. (Make - EPC ) (with 2yrs warranty)
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) (with 2yrs warranty) i) 9"( 230mm ) Speed 1370 RPM
ii) 12"( 300mm ) Speed 1420 RPM
SUB-HEAD 13 -- EARTHING Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe. [ 2(a)/G-1 ]
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil [1(a)/G-1 ]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS. No. 6 SWG [5(a)(ii)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS. [4(a)/G-2]
SUB-HEAD 14-- LIGHTNING CONDUCTOR S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar (4:2:1) as per GS [ 14 / J2 ]
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works as per GS [ 9 / J-1 ]
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work as per GS [ 11(a) / J-1 ]
Making soldered joints between conductors, conductors and air terminals by 7/10 stranded GI (Hot Dip) wire or 20 mm x 3 mm thick GI (Hot Dip) wire / strip incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint [12a / J-2 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
Making soldered joints between conductors and down pipes/ other metallic objects by 7/10 stranded GI (Hot Dip) wire including supply of necessary 4 SWG or 20 mm x 3 mm thick GI (Hot Dip) wire / strip incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint [12b / J-2 ]
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as requiredas per GS. [ 13 / J-2 ]
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: as per GS Length above 0.5 Mtr [ 4(b) / J1 ]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run GS [ 7 / J1 ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (32 mm dia) [11(b)/F-6] i) 32 mm dia
SUB-HEAD 15-- SERVICING & REPAIRING OF A.C. FAN Taken down & re-fixing the same fans by the agency's own tools & tackles in existing place.
Opening the fan part by part, testing, cleaning the fan blade & body by supplying cleaning materials and remove the dust from blade & body with satisfactorily. After cleaning the fans making the overhauling, varnishing, greasing the bearing and refitting & testing the same with satisfactory RPM.
Rewinding by supplying super enameled copper wire of appropriate gauge, mina lax paper, mica sheet, changing the loops, overhauling, backing, varnishing & refitting, testing and measuring the appropriate RPM (Old type)
Supply & Fixing new ball bearing in place of defective one. [Make- SKF / Tata.] 6201
Supply & Fixing new ball bearing in place of defective one. [Make- SKF / Tata.] 6202
Supply & Fixing new ball bearing in place of defective one. [Make- SKF / Tata.] 6203
Supply & Fixing the gun metal bush in place of defective one of required size.
Supply & Fixing metal type oil filled fan condenser of 2.2 to 3.6 mfd as required. [Make- Tibcon]
Supply & Fixing new split pin in place of old one, as required.
Supply & Fixingnew rubber rile insulator in place of old one, as of required size.
Supply & Fixing down rod wire by 2x1.5 sq. mm. insulated flex copper wire for down rod of required length (average 4 Mtr each).
Carrying charge for fans from work site to CO.'s workshop & back to Site.
SUB-HEAD 14 -- MISCELENEOUS Supply and fixing of cylinderical type HRC Fuse unit.(Make- L&T on existing main switch) a) 32A
Supply & Fixing 5A piano key type switch (Anchor make )
Supply & Fixing 6A 5 pin socket (Anchor make )
Supply & Fixing15A piano key switch (Anchor make )
Supply & Fixing 15A, 5 pin piano key socket (Anchor make )
Supply & Fixing250V capacitor in place of damage one. EPCOS make. With necessary wires. i) 50µF/60µF metal
ii) 04µF/06µF metal
Purging of Cooling and Condenser Coil with maffron gas pressure, leak testing by nitrogen gas pressure, leak removed by spot welding and complete flushing the system for Refrigerant gas charging.
Supply & charging of refrigerant (R-410a)
Supply & charging of refrigerant (R-32)
Dismantling the distribution board, switch board, existing wiring & unservisable materials incl. Mending good the damaged of building works and submit those materials to the concerned authority by 2(Two) electrician, 2(two) nos helper as per instruction of EIC incl. reinstallation of 2nos. AC after servicing the machines.
N.B: i) Payment will be made after availability of fund from concern Department. ii) Payment will be made as per P.W.D norms.
M/S. S. D. CHATTERJEE AND CO. (BID ID -6886089)
M/s Joy Durga Electric Repairing Shop (BID ID -6886071)
B M ELECTRIC (BID ID -6898074)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .