Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.7 CrAccepted-AOC | ₹58.7 Cr | L1 | Accepted-AOC Being Lowest and Reasonable Tender |
| 2 | L2₹70.5 CrRejected-Finance | ₹70.5 Cr | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹75.1 CrRejected-Finance A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹75.1 Cr | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹76.7 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹76.7 Cr | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹86.6 CrRejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹86.6 Cr | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹70.8 Cr
EMD Value
₹15 L
Closing Date
4 Apr 2024, 6:00 pmClosed
Chief Engineer (Navy) Mumbai
Headquarters, Chief Engineer (Navy) Mumbai, Shahid Bhagat Singh Marg, Colaba Mumbai 400 005
PROVISION OF ADMIN CUM OFFICE ACCN AND SINGLE LIVING ACCN FOR SAILORS (G PLUS 21 FLOORS) INCLUDING GALLEY, DINING HALL AND MULTI LEVEL PARKING AT DOCKYARD, MUMBAI
2024_MES_644378_1
87933/E8
Open Tender
Civil Works
912 days
Mumbai
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (P) NW No 1 Mumbai
₹15 L
Yes
Q Chief Engineer (Navy) Mumbai
25 May 2024
29 Feb 2024
6 Apr 2024
29 Feb 2024
4 Apr 2024
28 Mar 2024
29 Feb 2024 - 9 Mar 2024
7 Mar 2024
Amount
SCHEDULE "A" Part - I (BUILDINGS & STRUCTURES WORKS) Total of Sch-'A' Part-I B/F
SCHEDULE "A" PART-II (SITE CLEARANCE, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Total of Sch-'A' Part-III B/F
SCHEDULE "A" PART-IV (INTERNAL ELECTRIFICATION) Total of Sch-'A' Part-IV B/F
SCHEDULE "A" PART-V (ROAD & CULVERTS) Total of Sch-'A' Part-V B/F
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Total of Sch-'A' Part-VI B/F
SCHEDULE "A" PART-VII (AREA DRAINAGE) Total of Sch-'A' Part-VII B/F
SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-VII B/F
SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-IX B/F
SCHEDULE "A" PART-X ( FIRE FIGHTING ) Total of Sch-'A' Part-X B/F
SCHEDULE "A" PART-XI (COOLING & HEATING APPLIANCES ) Total of Sch-'A' Part-XI B/F
SCHEDULE "A" PART-XII ( AVIATION LIGHT ) Total of Sch-'A' Part-XII B/F
BLANK
BLANK
SCHEDULE "A" PART -XIII (MISCELLANEOUS ITEMS)
SITE CLEARANCE & EARTHWORK
Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Note for 16.01 (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. (iii) All excavation earthwork covered under Sch 'A' part III to part XIII shall be measured and paid under this item.
INTERNAL WATER SUPPLY
S&F Angular stop cock quarter turn (wall mount) with 20 mm diameter made of Chrome Plated (CP). Make - Jaquar Model No CQT-CHR-23059 or techno commercial equivalent makes mentioned in particular specification.
S&F for Stainless steel concealed stop cock, Regular body with adjustable wall flange, size 20/25mm dia. Make - Jaquar Model no CQT-CHR-23089 or techno commercial equivalent makes mentioned in particular specification.
S & F Overhead shower single flow 80mm dia (abs cp), complete all as specified and directed by Engineer-in-Charge.Make-Jaquar Model No: OHS-CHR-1985 or Techno-commercial equivalent in makes mentioned in Particular Specification.
S&F Florentine Pillar cock with quarter turn of Chrome Plated (CP), knob controlled. Make - Jaquar Model No. FLR-5015 or techno commercial equivalent makes mentioned in particular specification.
S&F Chrome Plated (CP) Urinal flush valve of 20mm diameter round shape (installation type : wall mount). Make -Jaquar Model No.-1093 or techno commercial equivalent makes mentioned in particular specification.
S&F Chrome Plated (CP) Sink Cock with swinging casted round shape spout (wall mounted model) 20mm dia, quarter turn. Make-Jaquar Model No CQT_23347 or techno commercial equivalent makes mentioned in particular specification.
Blank
S&F of 2 way bib cock 15mm dia. Make Model No CQT-23041or techno commercial equivalent makes mentioned in particular specification.
S & F Brass Forged Pressure Reducing Valves of 50mm dia complete all as specified and directed. Make - ZOLOTO (Article No: 1040B ) or Techno-commercial equivalent in makes mentioned in Particular Specification.
S&F Fancy Type 15mm dia long body taps cast copper alloy, Chromium plated screwed down to iron pipe or for brass ferrule & fixed complete all as specified & directed
S & F Shower arm casted 190mm long light body round shape for wall mounted showers with flange complete all as specified and directed by Engineer-in-Charge.Make-Jaquar Model No : SHA-CHR-477 or Techno-commercial equivalent in makes mentioned in Particular Specification.
INTERNAL ELECTRIFICATION
S & F 20 W surface / wall mounted LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy highest, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture and PVC mounting boxes-02 Nos complete all as specified and directed by the engineer-in-charge. Make: Havells Cat-Part No. LHEXAWP7IN1W020 or techno commercial equivalent makes mentioned in particular specification.
S & F 20 W surface / wall mounted motion sensor LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy highest, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture and PVC mounting boxes-02 Nos complete all as specified and directed by the engineer-in-charge.(for stair case) Make: Havells Cat-Part No. LHEXARP7UN1W020 or techno commercial equivalent makes mentioned in particular specification.
S & F10 W surface / wall mounted LED batten capable of delivering 1150 lumen, having PC diffuser, luminous efficacy highest, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture and PVC mounting boxes-02 Nos complete all as specified and directed by the engineer-in-charge. Make: Havells Cat-Part No. LHEXACP7IN1W010 or techno commercial equivalent makes mentioned in particular specification.
S & F10 W surface / wall mounted motion sensor LED batten capable of delivering 1150 lumen, having PC diffuser, luminous efficacy highest, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture and PVC mounting boxes-02 Nos complete all as specified and directed by the engineer-in-charge.(for stair case)
S & F LED light fittings decorative 36Watt, 2'X2' recessed mounting type extruded metal/aluminium body, and electronic LED driver, connector block etc.. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc. Make: Bajaj Cat Part No-BZRSQL36WGZINW or techno commercial equivalent makes mentioned in particular specification.
S & F LED Bulk head fittings 10Watt surface mounting type powder coated pressure die cast aluminium alloy housing diffused polycarbonate held with a silicon gasket, IP66 and electronic LED driver, connector block, SPD 2.5KV etc.. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc.
S & F LED light fittings decorative 18Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block etc.. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc. Make: Bajaj Cat Part No-BZSSQL18WWH or techno commercial equivalent makes mentioned in particular specification.
S&F ceiling mounted motion sensor 360 degree for automatic light on/off range 8 metre 3 wire with neutral, connecting load not less than 120watt, adjustable time delay 5seconds to 30minutes all as specified.
S & F LED Security light fittings 30Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, etc.. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size, GI pipe bracket made of GI pipe light grade 0.6RM length bent to shape with necessary clamps, bolts etc. all as directed by Engr-in-Charge. Bajaj Cat Part No- BCLST30WLED or techno commercial equivalent makes mentioned in particular specification.
S&F Energy efficient BEE five star rated BLDC ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. Make: Havells Cat Part No-FHCNF5SWHT48 or techno commercial equivalent makes mentioned in particular specification. Note:-Fan shall be controlled through fan Regulator. Fan regulator will be measured & paid Separately.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed by engineer-in-charge. (for toilets/washrooms) Make: Havells Cat Part No-FHVTADXWHT10 or techno commercial equivalent makes mentioned in particular specification.
Supply & fix wall mounted reading light fitting adjustable type including LED lamp 6/7 watt complete all as specified.
S & F factory made not less than 1.2 mm thick sunken & 60mm depth, modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable for modular cover plates complete all as specified and directed by the engineer-in-charge of size:- 8 module .
S & F single pole & neutral double door, modular type, metallic distribution board, conforming to IEC 61439-3, suitable for flush / surface mounting with provision for RCBO / MCB as incomer and SP/TP MCBs as outgoing, reversible metal door, suitable size copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. [i] FP RCCB / RCBO / Isolator / MCB & SP/TP MCBs shall be measured and paid separately. i) Single pole & neutral DB, 18 way
M&L for MCB SP 50 A, 240 V, C-Curve 10 kA all as directed by the engineer-in-charge.
M&L for MCB SP 63 A, 240 V, C-Curve 10 kA all as directed by the engineer-in-charge.
S&F modular Socket 25 Amp, single phase 230 volts suitable for split AC all as directed.
S&F Modular Double pole switch 32amp suitable with power indicator suitable for split AC all as directed
Supply & fix LED busy light (LED engagement light) consisting of One Red lamp & One Green lamp of suitable wattage for officers room, shade material plastic, mounting type wall mounted all as specified & as directed by Engr-in-Charge.
Supply & fix surface mounted decorative metallic body not less than 30watt LED ceiling light suitable for porch area having ceiling height upto 7m all as specified.
S&F Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 25Amps C Curve 10KA all as specified & as directed by Engr-in-Charge.
Supply & lay PVC insulated and PVC Round Sheathed, 4 core 35 Sqmm Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 complete with copper lugs for connecting from tap off box to Floor main DB (6th Floor) inside electrical shaft all as directed by Engr-in-Charge
Supply & lay PVC insulated and PVC Round Sheathed, 4 core 4 Sqmm Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 complete with copper lugs for connecting from tap off box to Floor main DB (Ground to 5th Floor) inside electrical shaft all as directed by Engr-in-Charge
Supply & lay PVC insulated and PVC Round Sheathed, 4 core 25 Sqmm Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 complete with copper lugs for connecting from tap off box to Floor main DB (7th to 21st Floor) inside electrical shaft all as directed by Engr-in-Charge
S & F modular type 1 module telephone socket with shutter including galvanized sheet metal box, recess mounted all complete all as specified and directed by the Engineer-in-Charge. Make: Legrand Cat No: 5734 26 or techno commercial equivalent makes mentioned in Particular Specification.
S & F modular type 1 module TV socket including galvanized sheet metal box, recess mounted complete all as specified and directed by the Engineer-in-Charge. Make: Legrand Cat No: 5734 25 or techno commercial equivalent in makes mentioned in Particular Specification.
Supply & Install Surge Protection Device confirming to IEC 61643-11, Type 2, I (max) 40KA, Configuration : 1P+N, Module: One complete and including suitable size copper flexible wire upto 5RM from Main floor DB to SPD and SPD to nearest Earth dolly.
M&L FP MCCB 125A 25KA Adjustable type all as directed by the engineer-in-charge.
SEWAGE DISPOSAL
S&F of 150mm dia DOUBLE WALL CORRUGATED PIPES, DWCPE (SN8) pipes
S&F of MS Rungs 10mm dia having size 265x 165x 25 mm.
EXTERNAL ELECTRIFICATION
Supply & install, test and commissioning of automatic power factor control (APFC) panel indoor type size for 300 KVAR, 3 Phase, 440 Volts, 50 Hz with multistage correction operate in 8 steps configuration will be (1x 100 KVAR, 2x 50 KVAR and 4 x25 KVAR ) all as specified.
DESCRIPTION 300 KVAR APFC PANEL(TECHNICAL SPECIFICATION) INCOMER 1 630A 3P 36kA MCCB Microprocessor Release , 415V AC 50Hz-1Nos 2 Extended Rotary Handle for MCCBs-1Nos 3 Spreader Terminals - 3 Pole (Set of 6) for DN3-630 MCCB-1Nos 4 8 Stage Automatic Power Factor Correction Relay, Single CT type, Size: 96x96, Parameter: V, 1, Capacitor Current, PF, VTHD, ITHD, SFIFO, FIFO, Acc Cl: 1.0,-1Nos 5 Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-1Nos 6 Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-1Nos 7 Blue Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-1Nos 8 600/5A 10VA Acc. CL-1 ABS insulated Current Transformer-3Nos 9 6A 1P 10kA, C-Curve MCB-3Nos 100 KVAR FEEDER 1 250A 3P 25kA MCCB TM Release, , 415V AC, 50Hz-1Nos 2 Spreader Terminals - 3 Pole (Set of 6) for MCCB-1Nos 3 27.7kVAr 3Ph Heavy Duty Phi Cap-Cylindrical 480V AC Capacitor-4Nos 4 100kVAr Thyristor Switch Module, Voltage: 440V AC, -1Nos 5 100kVAr 3Ph 7% Aluminium Wound Detuned Reactor, Voltage: 440V AC-1Nos 6 Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-1Nos 7 6A 1P 2Way Local - Remote/Auto Manual Switch with Center OFF, 60 Deg.Operation-1Nos 8 6A 1P 10kA, C-Curve MCB-1Nos 50 KVAR 1 125A 3P 10KA MCCB (Spreader Terminals included) TM Release, 2 415V AC, 50/60Hz-2Nos 3 27.7kVAr 3Ph Heavy Duty Phi Cap-Cylindrical 480V AC Capacitor-4Nos 4 50kVAr 3Ph 7% Aluminium Wound Detuned Reactor, Voltage: 440V AC-2Nos 5 50kVAr Thyristor Switch Module, Voltage: 440V AC, Type: TSM 50-2Nos 6 Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-2Nos 7 6A 1P 2Way Local-Remote/Auto-Manual Switch with Center OFF, 60 Deg. Operation-2Nos 8 6A 1P 10kA, C-Curve MCB-2Nos
25 KVAR 1 63A 3P 10kA, C-Curve MCB-4Nos 2 27.7kVAr 3Ph Heavy Duty Phi Cap-Cylindrical 480V AC Capacitor-4Nos 3 25kVAr 3Ph 7% Aluminium Wound Detuned Reactor, Voltage: 440V AC-4Nos 4 25kVAr Thyristor Switch Module, Voltage: 440V AC, -4Nos 5 Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-4Nos 6 6A 1P 2Way Local Remote/Auto-Manual Switch with Center OFF, 60 Deg.Operation-4Nos 7 6A 1P 10KA, C-Curve MCB-4Nos FABRICATION DETAILS 1 FABRICATION: 14/16 SWG CRCA Sheet PRE TREATMENT: 7 TANK PROCESS PAINTING: POWDER COATED WITH SIEMENS GREY SHED (RAL 7032) TYPE: FREE FLOOR RESTING, FIX TYPE, SINGLE FRONT, NONCOMPARTMENTLISED DESIGN CABLE ENTRY: TOP/BOTTOM (DETACHABLE GLAND PLATE UNDRILLED) 2 PANEL SIZE: LxBxH: 1000X600X1500 (MM) 3 BUSBAR: PH: 40X10X2, N: 40X10X1-1 set, Material- Aluminium Current Density: 1 Amp/Sq. mm Insulation: Colour coded heat shrinkable Sleeves 4 EARTH BUSBAR:-1 set
The busbar trunking system shall conform to the following technical specifications: "A.(i)The busbar trunking system (BTS), both feeder and plug-in, shall be of sandwich construction. All components and fittings (straight length, elbow, tees, flanged ends, cable tap box and circuit breaker, etc.) shall be in accordance with IEC 61439 Part 6 (2012) or UL857 and from the same manufacturer as the busbar trunking system. Degree of protection of the BTS shall be IP 54 in accordance with IEC 60529 (ii)Rated operation voltage of the BTS shall be 1kV. The neutral conductor shall have the same cross-sectional area as the phase conductor. The earth busbar must be one continuous piece without bolting on housing." "B.(i) The busbar, of full range and each rating, shall pass full type tests specified in IEC 61439-6. The certificate shall be issued by an international independent testing authority (e.g. ASTA, KEMA, UL) (ii) A product safety mark (e.g. KEMA-KEUR, ASTA DIAMOND, UL) shall be on the product offering a visible assurance to all of full product safety testing, factory inspection and ongoing surveillance under independent authority to ensure the ongoing safety of product (iii)The BTS shall pass seismic tests with actual physical product and being certified complying with UBC seismic Zone 4 condition by an international recognized earthquake research body, e.g. Asian Pacific Network of Centres for Earthquake Engineering Research (ANCER)" "C.(i) Short-Circuit Ratings & Tests: [i] The whole BTS shall be capable of withstanding the short circuit of the electrical installation without undergoing any electrical, mechanical and thermal stress under fault condition at a service voltage of 1kV at 50Hz frequency. The minimum rated insulation voltage shall be 1kV. (ii) Minimum certified short circuit ratings shall be 50kA for 1 sec for 800A BTS." "D.(i) The busbar trunking housing shall be constructed of electro galvanized steel and aluminium to reduce hysteresis and eddy current loses and shall be provided with a suitable protective finish of ANSI 49 grey epoxy paint (ii)The busbar trunking housing shall be totally enclosed non-ventilated for protection against mechanical damage and dust accumulation. And it shall pass at least 2000hr salt spray test to ensure the anticorrosion ability (iii) The totally enclosed housing shall be manufactured by the busbar trunking manufacturer. Modifications of busbar trunking to make it totally enclosed by housing other than the busbar trunking manufacturer voids the manufacturer's warranty. Busbar trunking so modified is unacceptable without the written consent of the manufacturer" "E.(i)Busbars shall be of aluminium with copper cladding utilized Molecular Fusion Technology. (ii)There shall be no bolts passing through the busbars of the busway [iii] Each busbar shall be insulated with Class B (130 °C) DuPont Mylar insulation. Epoxy insulation is unacceptable (iv) The temperature rise at any point of the busbar trunking enclosure shall not exceed 55°C above the ambient temperature of 40°C when operated at rated current." "F [i] The busbar trunking joint shall be of the one-bolt type which utilizes a high strength steel bolt(s) and Belleville washers to maintain proper pressure over a large contact surface area. [ii] The bolt shall be torque indicating and at earth potential. [iii] The bolt shall be two-headed design to indicate when proper torque has been applied and require only a standard long handle wrench to be properly activated. [iv] Access shall be required to only one side of the busbar trunking for tightening joint bolts. (v) It shall be possible to remove any joint connection assembly to allow electrical isolation or physical removal of a busbar trunking length without disturbing adjacent busbar trunking lengths"
G .Plug-in Openings: "[i] The connecting jaw of the plug-in unit shall plug directly on to the busbar and have full contact with busbar itself. Welded tab at plug-in busbar is unacceptable [ii] All contact on joint and plug-in opening should be silver plated copper [iii] On plug-in busbar trunking there shall be three dead front, hinged cover type plug-in openings on each side All openings shall be usable simultaneously [v] Busbar trunking shall be installed so that plugs are side mounted to permit practical use of all plug-in openings [vi] It shall be possible to inspect the plug-in opening and busbars prior to the installation of the plug-in units "H. Plug-in units [i] The plug-in jaw shall be spring design composed of different metal to ensure the firm and tight contact with the busbar. [ii] Plug-in Units shall be type tested in accordance with IEC 61439-6 [iii] The earthing contact of the plug-in unit shall always be made before that of the live conductors and the last to break during removal. And it must connect to the earth bar of busway to ensure the safety [iv] Covers of all plug-in units must have interlocks to prevent the cover from being opened when the switch is in the ON position [v] Plug-in units (circuit breaker type or fusible switch type) shall be operated with visible blade quick-make and quick-break mechanism. [vi] Presence of transparent shield shall be inside to avoid direct contact of human [vii] The plug-in units shall be equipped with internal barriers to prevent accidental contact of fish tape and conductors with live parts on the line side of the protective device during time of wire pulling." I. Supporting Structure: Indoor feeder and plug-in busbar trunking shall be approved for hanger spacing of up to 3m for horizontally mounted run and 4.88m for vertically mounted runs. Outdoor feeder busbar trunking shall be approved for spacing of up to 1.5m for horizontally or vertically mounted runs. J. Voltage Drop: [i] The 3-phase line to line voltage drop 40% power factor concentrated load shall not exceed 3.4V per hundred ft.[ii] The line-to line voltage drop at the load power factor shall not exceed 4.1V per hundred feet.
Supply, Installation, Testing and commissioning of tap off boxes of suitable size with MCCBs. All MCCBs shall be with thermal magnetic adjustable releases for O/L and S/C. The MCCBs shall have Ics = 100% Icu. All tap of boxes shall support the cable sizes given in SLD along with tender.
(a) 160 A, FP, 25KA.
(b) 100 A, FP, 25KA
(c) 32A, FP, 16KA.
Supply Installation, testing and commissioning of LED type street light fitting 70W capacity, IP 66 pressure die cast housing with epoxy powder coated aluminium housing dark graphite grey colour finish Enclosure complete with control driver fixed on street light pole connecting with 1.5 sqmm 3 core copper cable from street light fitting to junction box/loop in loop out box with suitable size lugs/thimble including GI pipe bracket made up of 32mm dia GI pipe light grade bent to shape, clamps, nuts, bolts etc. complete all as specified and directed.
Supply and fixing of outdoor weatherproof PVC enclosure junction box of size 250x200x100mm fitted to the pole fixing with MS FI clamps size 25mm wide x 2mm thick 02Nos, suitable size nut, bolts and washers complete including 6 amps MCB SP and Bakelite connector for terminating incoming and out going cables complete all as specified & directed by Engineer-in- Charge.
Supply, installation, testing and commissioning factory made Main LT panel board suitable for working on 3 phase, 4 wire, 415V AC, 50HZ, indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting, CPRI approved, separate compartment for ACB/MCCB/metering equipment's/cable galley etc. front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc., earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50x50x6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- (Note : Panel shall be ordered only after approval of GA drawings by GE)
Supply, installation, testing and commissioning Building LT panel board factory made suitable for working on 3 phase, 4 wire, 415V AC, 50HZ, indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting, CPRI approved, separate compartment for ACB/MCCB/metering equipments/cable galley etc front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50x50x6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- Note : (i) Panel shall be ordered only after approval of GA drawings by GE (ii) Panel shall be designed in such a way that there shall be a provision for connecting Bus Trunking System directly from panel.
Supply, installation, testing and commissioning DG panel board suitable for working on 3 phase, 4 wire, 415V AC, 50HZ, indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting, CPRI approved, separate compartment for ACB/MCCB/metering equipments/cable galley etc front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50x50x6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- Note : (i) Panel shall be ordered only after approval of GA drawings by GE
INCOMER (i) MCCB 4 pole adjustable thermal & fixed magnetic type 250A, 415V, 50HZ, 36KA - 01 No (incomer) OUTGOING (i) MCB SPN 16A,230V,50HZ,10KA-12 Nos (to street light& common area) (ii) MCCB 4 pole 63A,415V, 50HZ,16KA - 01 No (to pump panel ) (iiI) MCCB 4 pole 50A,415V, 50HZ, 16KA with extended terminal - 03 Nos (to lift) (iv) MCCB 4 pole 63A, 415V, 50HZ,16KA with extended terminals, shunt trip coils – 04 Nos of suitable capacity with and including all necessary accessories and wires for tripping of MCCB on receiving of command from fire alarm panel/ control module (to lift) BUSBAR 400A rated Copper bus bar with colour code heat shrinkable sleeve. METER & INDICATION (i) Ammeter, Digital type ,with suitable CTs - 01set. (ii) Voltmeter, Digital type -01 set (iii) R-Y-B PHASE indicating lamp - 01 set. (iv) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. (v) CONTACTOR 32Amp Single pole -1 NO (FOR STREET LIGHT) (vi) Digital TIMER SWITCH 230V AC -1 NO
Supply, installation, testing and commissioning pump panel board suitable for working on 3 phase, 4 wire, 415V AC, 50HZ, indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting, CPRI approved, separate compartment for ACB/MCCB/metering equipments/cable galley etc front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50x50x6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- Note : (i) Panel shall be ordered only after approval of GA drawings by GE
INCOMER (i) MCCB 4 pole adjustable thermal & fixed magnetic type 63 A, 415V, 50HZ,16KA - 01 No (incomer) OUTGOING (i) MCCB 4 pole adjustable thermal & fixed magnetic type 40A,415V,50HZ,16KA-02 No (ii)) Fully Automatic Star-delta starter suitable for 20HP,3-phase AC 50HZ induction motor with all protection devices like single phase preventer, overload relay etc, push button, indicators etc-2NOS. (iii) MCB SP 6A ,10KA,B CURVE-02 Nos(for P/H DB & 01Spare). BUSBAR 100A rated Copper bus bar with colour code heat shrinkable sleeve. METER & INDICATION (i) Ammeter, Digital type ,with suitable CTs(0-400A)-01sets. (ii)Voltmeter, Digital type (500V)-01sets (iii)R-Y-B PHASE indicating lamp-01 sets. (iv) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. (v) FIXED CAPACITOR 4KVAR-1NO (FOR PUMP) - capacitor shall work only when motor is running & there shall be one control for both motor & capacitor.
Material & labour for removing 630KVA transformer from existing location complete with disconnecting HT/LT electric connection & taking out carefully and shifting to GE Kunjali Yard, including T/D old HT cable & LT cables connected with existing transformer.
M&L for cutting of road/hard standing having thickness upto 15cm for laying of cable, pipe etc and making good all as directed & specified by Engr-in-Charge
Supply & fixing prefabricated, perforated cable tray from MS sheet and then hot dip galvanised, of following sizes and including associated accessories such as coupler plates, tees, elbow, supports, angles, anchor bolts, washers etc. Galvanisation thickness shall be minimum 86 Micron. of size 200 x 100mm x 2mm all as specified & directed by Engr-in-Charge.
Materials and labour for Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth strip 32x6mm mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MES schedule part-I, earth lead strip connected to indicated position including 7.5m long 15 mm bore GI pipe for earth wire protection and concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c both ways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe "medium grade" for watering with GI funnel and wire mesh including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil and testing on completion complete, including earthing test point all as specified and as directed by Engineer in Charge. Note:- (i) Body of all LT panels,APFC Panel installed within a bldg shall be connected to common earth bus bar made of GI strip 50x6mm of sufficient length for earthing purpose run over wall. This bus bar to be connected to two distinct earthing pits.(earthing value shall be less than 3ohms, Additional earthing to be made to achieve less than 3 ohm value free of cost) (ii) GI earth strip beyond 7.5 RM shall be measured and paid for separately under relevant item of schedule .
EXTERNAL WATER SUPPLY
M & L Excavation in trench by cutting of road crossing /PCC hard standing, for laying of pipes/cable including making good the existing surface with same finish to match the original finish all as directed by Enge-in-charge.
Supplying and fixing pvc insulated & sheathed cable for voltage level upto 1100 volts, conforming to IS code 694 with copper conductor size 3core 10sqmm for pump connection from starter panel.
Cutting in position existing GI pipe of size 100mm dia ,insertion of GI tee 100x100x100mm bore including connected fittings complete and necessary excavation, refilling and disposal of surplus material complete all as specified and directed
Materials and labour for Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth strip 32x6mm by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MES schedule part-I, earth lead strip connected to indicated position including 7.5m long 40 mm bore GI pipe for protection and concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c both ways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe "medium grade" for watering with GI funnel and wire mesh including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil and testing on completion complete all as specified and as directed by Engineer in Charge. NOTE -: 1) GI earth strip beyond 7.5m length shall be measured and paid for separately under relevant item of schedule . 2) Body of water supply LT panel and 2-pump sets shall be connected to common busbar made of GI Strip 32x6mm for earthing purpose run over wall. This bus bar to be connected to two distinct earthing pits .Each Earthing value shall be less than 3 ohms. Additional earthing to be made to achieve 3 ohm free of cost
FIREFIGHTING
Supply and fixing, testing and commissioning suitable C.I automatic air release single valve conforming to is 14845-2000 of 50mm dia including one no of 50mm dia gun metal stop valve with necessary fittings, support and painting with two coats of enamel paint over a coat of primer etc all as specified and as directed by Engr-in-Charge.
Supply and fix standard fireman's axe with heavy insulation rubber handle.
Supply and fixing SS orifice with 6mm thick disc with tag on plate mentioning dia of orifice for sprinkler system to control the pressure including rubber gasket packing ,bolts nuts, washers all complete. Note : Contractor shall design the orifice to ensure the required pressure at each floor.
Supply & erection of 6 kg capacity ABC(Powder type) Fire Extinguisher in HP Mild steel cylinders, ISI Marked/approved fitted with pressure indicating guage, internal tube, squeeze lever type valve fully changed with ABC powder (Mono Ammonium Phosphate)Pressure by nitrogen complete in all respect including wall suspension bracket and conforming to IS:15683.
Supply & erection of ISI marked(IS:15683) Fire Extinguisher seamless construction, carbon-di-oxide type capacity 4.5kg flat base including guage, discharge hose of not less than 10mm dia,1mtr long complete in all respect including initial fill with co2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.677 and with wall suspension bracket.
S&F of ISI marked IS:15683 Mechanical foam (AFFF) unit of 9 ltrs. Capacity with water inlet and foam water out let, foam maker, foam branch pipe etc. complete. Unit shall be fabricated by M.S. sheet with FRP lining inside and whole unit mounted with wall suspension bracket.
Supply, Install, testing and commissioning of 1500mm in length stainless steel flexible sprinkler pipe (braided) 25mm dia with union, clamps, collar etc complete all as specified and as directed by Engr-in-Charge. (To be provided for each sprinkler in false ceiling area only)
Supply, Install, Testing and commissioning Zonal Annunciator panel made of CRCA sheet with powder coated finish and red colour conforming to IS:2189 with 24 hour battery backup with built in Charger, 24 Way, Operating temperature 0 to 40 degree c ,AC power 220V, 50HZ,and stand by:24V DC ,Operating humidity ;95%(non-Condensing) all as specified.
Supply & install ceiling mounted fire extinguisher 5KG , clean agent HFC 236F, zero ODP stored pressure type, discharge time less than 8 second, auto discharge mechanism on temperature rise applicable on class A,B,C & electrical fire .
Supply, fabricate, install and testing Gl duct of thickness1.0 mm thick all as specified and as directed by Engr-in-Charge
Supply, fabricate, install and testing flexible connections constructed of fire resistant resin double sleeve all as approved by GE
Supply & fixing powder coated grill with damper of size 600mmx450mm .
Blank
Supply, Installation, testing & commissioning addressable type Flame Detector with UV+IR detection capacity (add up to cost of module to be a complete set, the type of module shall be relay type module)with self built intelligence complete all as specified and directed.
Supply, laying, testing & commissioning of ISI marked 2 core x 1.5 Sqmm, copper armoured cable, PVC insulated, FRLS confirming to IS 1554 Part-1 Red in colour with GI saddle spacing at every 300mm, junction box as required at site, lugs, ferrules, cable tags etc all as specified and as directed by Engr-in-Charge. (for fire alarm and PA system). Note: There shall be no joint in the cable between detectors/devices.
Supply, Install, Testing & Commissioning of Addressable 2 way communication (between remote fire fighter and fire control room) Fire Fighter's Telephone Jack with all mounting accessories , complete with SS enclosure for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling etc complete as required. The telephone jack shall sense the insertion of Fireman's handset into Jack & immediately signals the status to the master panel
Supplying, installing, testing and commissioning of Fire fighters telephone handsets with coil in a recessed mounted single storage cabinet. Complete as required
Supplying, installing, testing and commissioning of 2W False Ceiling Mount Speakers with inbuilt 70/100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with mounting clamps as per specifications
M&L for provision of signage system in accordance with IS 9457, IS 12349 & IS 12407 of latest codal provisions. The signage board shall be made of suitable fire rated material and suitable size. All signages shall be photoluminescent & self luminated type and laser printed. Signage boards shall be fixed properly using fasteners like screws on wall or hanging over from ceiling using double side suspension chain etc at following locations all as specified and as directed by Engr-in-Charge:-
(a) Manual Call Point Signage
(b) Fire Extinguisher Point Signage
(c) Fireman Telephone Jack Signage
(d) Fire Exit with arrow Signage
(e) Fire hydrant Point Signage
S&F First aid kit box with kit wall mounted of size 300x450mmx100mm suitable for refuge area.
M&L for testing and commissioning 63 mm dia 30 meter long RRL hose type I conforming to IS 636 complete with male and female coupling conforming to IS 903
Supply, Installation, Testing and commissioning in position drain & test assembly as per NBC-2016 comprised of 2 nos (50mm & 25mm) brass tested heavy duty ball valve with screwed ends confirming to IS 554 with BIS mark, including necessary G.I 'c' class pipe, (union 1nos & sight glass-1 no fitting etc.
Supply, installation, testing & commissioning of 24VDC power supply unit of capacity suitable for sounder cum strobes Qty-66 Nos + 20% extra capacity. The unit shall have in built battery charger & sufficient back of 24 hours in stand by & 30 mins in alarm condition. The power supply unit shall be monitored by fire alarm panel. Unit shall have features such as Low battery visual warning with audible tone, DC output indication, Lock & Key, Replaceable fuse for DC output, Auto resettable fuse for AC complete all as specified and directed by the Engineer-in-Charge.
COOLING / HEATING APPLIANCES
Supply and fix Double door refrigerator, frost free, electric driven single phase 230V capacity not less than 360ltr and nearest BEEE 5 star rated all as specified and as directed. Make: Model GL-379PEX5 of LG or techno-commerically equivalent in Samsung, Panasonic, Voltas, Whirlpool, Haier & Electrolux
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type& designed for input variation between 170Vto250V with output voltage stabilizer at 230V with accuracy of +/- 2.5% and of capacity 2.0KVA.
AVIATION LIGHT
Supply and fixing aviation light luminaire, LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified. Make:-Bajaj BGAV302LED or techno commercial equivalent makes mentioned in particular specification.
Design supply, install, testing & commissioning Goods lift, speed 1.5metre/ sec, lift with single speed motor 415volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to carry 20 passenger (1350kg) G +21 upper floors with AC Variable Voltage &Variable Frequency drive(VVVF drive) complete with all standard accessories, Cable from Machine room Main DB, simplex automatic & manual dual controlled operation without attendant, centre opening/ telescopic doors with door drive(electric moto.· driven mechanism), sliding stainless steel doors ,automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (one in lift car & one in near Ground floor landing door)& one with handset in lift machine room all as specified below. (a) Type: Goods lift (b) Load: 20Passenger. (c) Control: Microprocessor based with AC variable voltage & variable frequency(VVVF). (d)Machine:-Energy Efficient machine, Gearless, with Machine room. (e)Speed: 1.5mtr/sec. (f) Floor served: G+21 (g) Power supply 415volts,3-phase 4 wire AC 50HZ. (h) Car door automatic centre opening withV3F door drive sliding type, stainless steel hairline finish(N-304) for car and landing doors at all floors.
(i)Car enclosure standard manufacturing with MS frame & stainless steel hairline finish(N-304) in standard thickness with adequate LED light fitting on ceiling and covered with translucent acrylic cover fitted with stainless steel frame and concealed axial flow fan with stainless steel grill and also 2 no's vertical down light and covered with stainless steel wire mesh. (j) Door opening as per OEM. (k) Counter weight shall be of cast iron as recommended by OEM. (l) Flooring aluminium chequered plate 5mm. Signals:- (m)Combined luminous hall buttons with VFD hall position indicators at all floors (n) Vacuum filled Display(VFD) for car position indicators of stainless steel. (o)One no car operating panel with luminous button in car. (p) Car direction indicator in car & landing. (q) Battery operated alarm bell & emergency light(rechargeable) along with suitable maintenance free battery. (r) Overload warning features in car cabin. (s)Fireman switch one No per lift to be installed at Ground floor near landing door to be installed at ground floor. (t) All signal fixture & car operating panel on stainless steel face plate
Design supply, install testing & commissioning Passenger lift, speed 2.5metre/ sec, lift with single speed motor 415volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to carry 16 passenger (1088kg) G +21 upper floors with AC Variable Voltage &Variable Frequency drive(VVVF drive) complete with all standard Accessories & Cable from Machine room Main DB, simplex automatic & manual dual controlled operation without attendant, centre opening/ telescopic doors with door drive(electric moto.· driven mechanism), sliding stainless steel doors ,automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (one in lift car & one in near Ground floor landing door)& one with handset in lift machine room all as specified below. Make:- a) Type: Passenger lift (b) Load: 16Passenger. (c) Control: Microprocessor based with AC variable voltage & variable frequency(VVVF). (d)Machine:-Energy Efficient machine, Gearless, with Machine room. (e)Speed: 2.5mtr/sec. (f) Floor served: G+21 (g) Power supply 415volts,3-phase 4 wire AC 50HZ. (h) Car door automatic centre opening withV3F door drive sliding type, stainless steel hairline finish(N-304) for car and landing doors at all floors.
(i)Car enclosure standard manufacturing with MS frame & stainless steel hairline finish(N-304) in standard thickness with adequate light fitting on ceiling and covered with translucent acrylic cover fitted with stainless steel frame and concealed axial flow fan with stainless steel grill and also 2 nos vertical down light and covered with stainless steel wire mesh. (j) Door opening as per OEM. (k) Counter weight shall be of cast iron as recommended by OEM. (l) Flooring aluminium chequered plate 5mm. Signals:- (m)Combined luminous hall buttons with VFD hall position indicators at all floors (n) Vacuum filled Display(VFD) for car position indicators of stainless steel. (o)One no car operating panel with luminous button in car. (p) Car direction indicator in car & landing. (q) Battery operated alarm bell & emergency light(rechargeable)along with suitable maintenance free battery. (r) Overload warning features in car cabin. (s)Fireman switch one No per lift to be installed at Ground floor near landing door to be installed at ground floor. (t) All signal fixture & car operating panel on stainless steel face plate
Design, supply, install testing & commissioning Passenger lift, speed 2.5metre/ sec, lift with single speed motor 415volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to carry 13 passenger (844kg) G +21 upper floors with AC Variable Voltage &Variable Frequency drive(VVVF drive) complete with all standard accessories, Cable from Machine room Main DB, simplex automatic & manual dual controlled operation without attendant, centre opening/ telescopic doors with door drive(electric moto.· driven mechanism), sliding stainless steel doors ,automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (one in lift car & one in near Ground floor landing door)& one with handset in lift machine room all as specified below. (a) Type: Passenger lift (b) Load: 13Passenger. (c) Control: Microprocessor based with AC variable voltage & variable frequency(VVVF). (d)Machine:-Energy Efficient machine, Gearless, with Machine room. (e)Speed: 2.5mtr/sec. (f) Floor served: G+21 (g) Power supply 415volts,3-phase 4 wire AC 50HZ. (h) Car door automatic centre opening withV3F door drive sliding type, stainless steel hairline finish(N-304) for car and landing doors at all floors.
(i)Car enclosure standard manufacturing with MS frame & stainless steel hairline finish(N-304) in standard thickness with adequate light fitting on ceiling and covered with translucent acrylic cover fitted with stainless steel frame and concealed axial flow fan with stainless steel grill and also 2 no's vertical down light and covered with stainless steel wire mesh. (j) Door opening as per OEM. (k) Counter weight shall be of cast iron as recommended by OEM. (l) Flooring aluminium chequered plate 5mm. Signals:- (m)Combined luminous hall buttons with VFD hall position indicators at all floors (n) Vacuum filled Display(VFD) for car position indicators of stainless steel. (o)One no car operating panel with luminous button in car. (p) Car direction indicator in car & landing. (q) Battery operated alarm bell & emergency light(rechargeable)along with suitable maintenance free battery. (r) Overload warning features in car cabin. (s)Fireman switch one No per lift to be installed at Ground floor near landing door to be installed at ground floor. (t) All signal fixture & car operating panel on stainless steel face plate
Supply, Installation, testing and Commissioning of Dumbwaiter 250 Kg capacity having speed of 0.5 M/S serving 6 to7th floor (2 stops) and 02 openings on same side, platform size 900x900mm, lift well size 1500x1500mm, electric motor-1hp, 3-phase supply, providing overweight audio/annoucement alarm, LED light in car, stainless steel 304 grade cabin and Door panels as per technical specification Including required scaffolding & structural steel brackets for erecting lift as per above specification obtaining required all necessary permissions of Lift inspector (IE & L Dept.) to erect and complete the elevator work, Licence to operate the elevators including all necessary charges, payments for the same etc complete. (Belt or rope driven) Note : Contractor shall submit GA drawings, fixing arrangement drawings etc for approval of GE.
M & L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level with top edge of the plate not less than 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts, nuts checknuts and washers complete up to and including test point made out of 40 x 6mm aluminium flat including earth pit, charcoal common salt, earthing lead 32x6 upto 7.5m, 20mm dia medium grade GI watering pipe, PPC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No. 5 of SSR-2014 (part-I). (Lift - 6 Nos, DG Set - 4 Nos) NOTE – GI earth strip beyond 7.5 RM shall be measured and paid for separately under relevant item of schedule.
DG SET
A)DIESEL ENGINE Multi cylinder, in-line, 4 stroke, radiator cooled engine, well designed air handling system with dry type, heavy duty. Diesel Engine shall comply latest CPCB norms. The Diesel Engines are comprising of followings:- Radiator with Fan Fuel injection equipment with Electronic Governor Dry type Air Cleaner Extant Silencer Lube Oil filter (Spin On Type) Fuel Oil filter (Spin On Type) 12V electric starting system Battery charging alternator Stop Solenoid Lube Oil Pressure Gauge Water Temperature Gauge Lube Oil Temperature Gauge Battery Voltage: K-Cool Super Plus coolant First Fill Lube Oil
B) ALTERNATOR- PRIME RATED POWER (PRP) output of 160KVA at 1500 RPM 415. V.0.8 PF, 50Hz. 3Ph on SPDP Enclosure, Self-Excited & Self-regulated, Brush less, "H' class Insulation, Floor mounted with ante friction Shielded Ball Bearing on end. The alternator conforms to IS: 4722, BS EN 60034-1. C)BASE FRAME Suitable to couple above Engine & Alternator made from steel sheet metal D)FUEL TANK 8 Hrs Capacity for continuous running, with Diesel fuel Inlet & Outlet, Air Vent & Drain plug arrangements E)BATTERY 1 Na 12 V Battery with Leads of capacity as recommended by OEM (F) Accoustic Enclosure Followings are some technical features of ACCOUSTIC Enclosure- 1)The Enclosure is modular in construction 2) Base Frame is made of Sheet metal. 3) Durable industrial locking system is provided 4) Door Gaskets are made in high quality EPDM material. (G) CORROSION RESISTANCE Enclosure weather proof- 1)AIL sheet metal parts/components hot dipped in seven tanks process, Pre-treated and are hot Passivated 2) Sheet metal components are with Pre-treated and Passivated Base Powder Coated. 3) Base Frame is Epoxy Coated Powder Coated, 4) Zine Passivated Hardware's are used to avoid rusting. (H) ACOUSTIC INSULATION- 1) Sound proofing of the Enclosure is done with Quality Foam confirming to IS: 7888 Standard. 2) Acoustic foam shall be fire retardant and fire resistant 3)Attenuates are provided to control sound at entry and exit of container 4) Designed Residential Silencer is provided. (I)VENTILATION AND AIR CIRCULATION Exhaust pipe inside Enclosure is thoroughly insulated by Cladding of Rock wool and Sheet.
HOT WATER SUPPLY
SITC of Wall Mounted vertical Electric Water Heater (Geyser) with inbuilt 25 litres water storage stainless steel body tank, 02 kW rated copper heating element, 08 bar max. operating pressure, 05 star BEE rating, fully automatic, thermostat, indicators etc. This also includes all accessories required during installation like grouting, safety valves, NRV, connection pipes (hot & cold), suitable capacity electric plug top, electric cable etc. and suitable for 01 phase, 230 V, 50 Hz, AC electric supply as per standard practice and directions of Engineer In Charge . Warranty/Guaranty: Minimum one year on product or as per OEM
AIR CONDITIONING
Supply, install, test and commissioning air cooled split unit inverter type air conditioner electric driven AC 230V 50Hz, single phase of capacity of 2 TR, BEE 5 star rated, R32 Refrigerant, Copper Condenser Coil, Special Features: Anti Dust, Antimicrobial Protection, Anti-Corrosive Coating, LED Display, Self Diagnosis, Sleep Mode, Turbo, Adjustable Cooling including MS stand and bracket for outdoor & indoor unit, Drain pipe etc all as specified.
S&F automatic wall mounted voltage stabilizer for automatic operation 1 phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V (+/- 2.5% ) of capacity 4KVA all as directed.
LIGHTENING PROTECTION
S&F of 1 metre vertical aluminium air terminal of dia 15mm to meet the requirement of IS/IEC 62305 Including base. Tested for Electrical, Mechanical, Environmental test and should have Impulse current withstand capability of 100KA (Class H) and as per IEC 62561-182.
S&F of 25x3mm Aluminium Tape Conductor with fixing accessories and should be tested for electrical resistivity test, Tensile strength, Environmental test (salt spray & humidity test) to meet the requirements of IS/IEC 62305 and IEC 62561-182.
Supply, Installation, Testing & Commissioning of Aluminium Square Tape Clamp for Cross connection and T connection of 25x3mm Aluminium Tape should be tested for electrical resistivity test, Environmental Test (salt spray & humidity test), Mechanical test and Impulse current withstand capability of 100KA (Class H) to meet the requirements of IS/IEC 62305 and IEC 62561-1&2. considered)
Supply. Installation, Testing & Commissioning of single core 50sq mm Green/Yellow PVC insulated Copper cable with terminal Lug, should have Each stranded of 1.7 mm diameter as per requirements of IS/IEC 62305 and IEC-62561-2:2012.
Supply Installation, Testing & Commissioning of Bi-metallic Connector should be tested for Environmental Test (salt spray & humidity test). Contact resistance test, Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-182.
Supply, Installation, Testing & Commissioning of Test link should be tested for Environmental Test (salt spray & humidity test), Contact resistance test, Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-182.
Material and labour of maintenance free Earthing system comprising of 250 micron copper bonded earth rod 3 mtr x 3/4" Dia long Earth electrode, inspection pit with polymer lid is load rated to 5000 kg and suitable for general to heavy duty, copper rod to tape clamp and 25 kg of Earth Enhancing compound whose resistivity is less than 0.12 as per IEEE 80-2013 & IS 3043-2018 for normal soil condition. The compound shall be free from carbon and graphite and conductive in nature and should accommodate 60% of its volume. The rod should be threaded on both ends and all component should be tested as per IEC 62561. Note: 3m length shall vary depending upon soil resistivity.
Supply Installation, Testing & Commissioning of 25x3mm Copper Tape Conductor with fixing accessories and should be tested for electrical resistivity test. Tensile strength, Environmental Test (salt spray & humidity test) to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.
11 Supply, Installation, Testing & Commissioning of Copper Square Tape Clamp for Cross connection and T connection of 25x3mm Copper Tape should be tested for electrical resistivity test, Environmental Test (salt spray & humidity test), Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-182.
M&L for Welding of rebars as per OEM and tender drawing. (for 1 floor, 10 welding job x for 22 floor)
Supply and fixing of Reinforcement conductor clamps for interconnecting flat conductor with reinforcement bars to meet the requirements of IS/IEC 62305 .Complete as required .
Supply and fixing of Parapet Conductor Holder for Aluminium Conductor and Vertical Air terminal above concrete Parapet with fixing Screws/glue on parapet to meet the requirements for IS/IEC 62305.Complete as required .
Supply Installation, Testing & Commissioning of rod to clamps etc should be tested for Environmental Test (salt spray & humidity test), Contact resistance test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-182.
HORTICULTURE AND LANDSCAPE
Supply of organic manure neemstrid. NPK 19:19:19 for mining with good earth in required portion .
Supply and provide plantation for good quality ready made Korean grass in modules of 600x300mm size as per approved design for lawn complete all as specified and directed.
S & F saplings of Ashoka tree height 1.50 in plus. girth 2 cm to 4 cm pit size (0.9 m dia x 0.9 in depth) including at transportation, labour charges and incl of excavation in any type of soil for planting the sapling, pit size 8" to 15" and height 2 ft to 5 ft. completed all as specified and as directed by GE
Supply and planting of plants with decorative concrete pots, height of plants not less than 600 mm above ground level and having good health and well developed root system of Ficus Black.
Supply of potted decorative indoor plants
Supply of decorative bordering plant
FURNITURE
Manufacture & Supply of Almirah Steel Medium, complete all as specified and shown on drawing No. FD-1032.
Manufacture & Supply of Almirah Large Steel , complete all as specified and shown on drawing No. FD-1031
Manufacture & Supply of Almirah map Steel , complete all as specified and shown on drawing No. FD-1030
Manufacture & Supply of Bed Hard Steel, complete all as specified and shown on drawing No. FD/E6/MAP/08R .
Manufacture & Supply of Board Notice (1525 x 900 mm), complete all as specified and shown on drawing No. FD-1
Manufacture & Supply of Board Notice wooden(600 x 900 mm), complete all as specified and shown on drawing No. FD-1042
Manufacture & Supply of Steel Book case , complete all as specified and shown on drawing No. FD-1028
Manufacture & Supply of Chair writing MAP, complete all as specified and shown on drawing No. FD/E6/MAP/12
Blank
Balnk
Manufacture & Supply of Chair Dining complete all as specified and shown on drawing No. FD-279
Manufacture & Supply of Chair easy complete all as specified and shown on drawing No. FD-229
Manufacture & Supply of Chair with easy cushion complete all as specified and shown on drawing No. FD-358
Manufacture & Supply of Chair Dining JCO/Ors complete all as specified and shown on drawing No. FD/MAP/II/05
Manufacture & Supply of Chair writing complete all as specified and shown on drawing No. FD-280
Manufacture & Supply of Charpoy IP hard Top , complete all as specified and shown on drawing No. FD/MAP-II/01
Manufacture & Supply of Form without Back steel , complete all as specified and shown on drawing No. FD-77(M)
Manufacture & Supply of Hat Stand with mirror, complete all as specified and shown on drawing No. FD-362.
Manufacture & Supply of Hot case , complete all as specified and shown on drawing No. FD-363.
Manufacture & Supply of Mirror Dressing Gents, complete all as specified and shown on drawing No. FD/E6/MAP/16
Manufacture & Supply of Peg Table , complete all as specified and shown on drawing No. FD-277.
Manufacture & Supply of Rack adjustable steel six Tiers, complete all as specified and shown on drawing No. FD-1038.
Manufacture & Supply of rack side with tray( four spaces) steel, complete all as specified and shown on drawing No. FD-1023
Manufacture & Supply of Receptacle PVC , complete all as specified and shown on drawing No. FD/E6/MAP/13
Manufacture & Supply of Sofa set 2 seater , complete all as specified and shown on drawing No. FD-1113
Manufacture & Supply of Sofa set 5 seater , complete all as specified and shown on drawing No. FD-1113.
Manufacture & Supply of Stool revolving adjustable steel , complete all as specified and shown on drawing No. FD-1026
Manufacture & Supply of Stool wooden , complete all as specified and shown on drawing No. FD-286
Manufacture & Supply of Table 600X600mm , complete all as specified and shown on drawing No. FD-293.
Manufacture & Supply of Table 900X600mm with drawer , complete all as specified and shown on drawing No. FD-283.
Manufacture & Supply of Table 900X600X750mm without drawer , complete all as specified and shown on drawing No. FD-284.
Manufacture & Supply of Table bed side , complete all as specified and shown on drawing No. FD/E6/MAP/15R.
Manufacture & Supply of Table centre two Tier, complete all as specified and shown on drawing No. FD-375.
Manufacture & Supply of Table cook house large with Marble top, complete all as specified and shown on drawing No. FD-1014
Manufacture & Supply of Table dining 6 person , complete all as specified and shown on drawing No. FD/MAP-II/03.
Manufacture & Supply of Table office clerk steel , complete all as specified and shown on drawing No. FD-1004.
Manufacture & Supply of Table office officer steel , complete all as specified and shown on drawing No. FD-1003
Manufacture & Supply of Trestle store room wooden , complete all as specified and shown on drawing No. FD-141
Manufacture & Supply of Cabinet Filling , complete all as specified and shown on drawing No. FD-397
Manufacture & Supply of Revolving chair :Fabric PCH 7002D ,cushions seat fabric foam density 45+-2 kg/m3 ,seat size 76x99.5 -108.8x76cm ,fixed armrest, seating ht 44.8 cm ,Back type medium, back wt 11.4 kg , complete all as specified.-
SPECIAL FURNITURE
Manufacture & Supply of Compactor , complete all as specified. Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Chair Executive Mid Back , complete all as specified. Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Visitor Chair , complete all as specified. Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Chair Mid Back No.1, as per description mentioned in particular specifications, complete all as specified . Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Chair Mid Back No.2, as per description mentioned in particular specifications, complete all as specified . Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Magazine/Periodical display rack , complete all as specified. Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Premium Impress Executive table with side unit, complete all as specified . Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Senior Main Desk, complete all as specified . Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Table conference - Elegance 25 seater AV, complete all as specified . Make : Godrej, Durian, Featherlite.
Manufacture & Supply of Work Station Cubical single, complete all as specified . Make : Godrej, Durian, Featherlite.
Atlas and Dictionary stand: size 42 in H x 24 in W x 16 in D of Furniture grade Particle Board. Make: TLS (The Library Store) or equivalent
Book Trolley of Alloy steel material, Numbers of Shelves: 03 Nos, Wheels = 04 Nos, Make: Godrej, Durian, featherlite or equivalent
MANNING & OPERATION OF LIFTS
Manning & Operation of fully automatic electrically operated passenger lifts of any make, type installed in the subject project as per schedule given above by placing 2 lift operators in 2 shifts of 8 hrs including Sundays and holidays (0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs) including taking care of all lifts from any pilferage or damage etc (Total 6 Nos lifts) and 01 lift operator at night including Sundays & holidays during 60 months:- Note: Total number of Lift operators are 05 Nos.
(a) 11 months after completion of work
(b) 11 months after completion of BOQ item No. 32.02 here-in-before
(d) 11 months after completion of BOQ item No. 32.03 here-in-before
(d) 11 months after completion of BOQ item No. 32.04 here-in-before
(d) 11 months after completion of BOQ item No. 32.05 here-in-before
(f) 05 months after completion of BOQ item No. 32.06 here-in-before
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance and repairs of fully automatic electrically operated Goods lifts of any make installed in the subject project as per BOQ Item No. 25.01, given here-in-above (Total 1 Lift) comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by Engineer-in-Charge
(a) 1 year after expiry of defects liability period
(b) 1 year after completion of BOQ item No. 33.02 here-in-before
(c) 1 year after completion of BOQ item No. 33.03 here-in-before
Comprehensive maintenance and repairs of fully automatic electrically operated passenger lifts of any make and 16 Passengers installed in the subject project as per BOQ Item No. 25.02 , given here-in-above (Total 3 Lifts) comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by Engineer-in-Charge
(a) 1 year after expiry of defects liability period
(b) 1 year after completion of BOQ item No. 33.06 here-in-before
(c) 1 year after completion of BOQ item No. 33.07 here-in-before
Comprehensive maintenance and repairs of fully automatic electrically operated passenger lifts of any make and 13 Passengers installed in the subject project as per BOQ Item No. 25.03, given here-in-above (Total 2 Lifts) comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by Engineer-in-Charge
(a) 1 year after expiry of defects liability period
(b) 1 year after completion of BOQ item No. 33.10 here-in-before
(c) 1 year after completion of BOQ item No. 33.11 here-in-before
(iv) The rate quoted under this Sch A shall be deemed to include for materials and labour required for comprehensive maintenance including repairs. (v) The work covered under Sch A will be ordered on the contractor by the respective Garrison Engineer on every year through a separate works order for the lifts installed in their area at the rate quoted by the contractor till completion of three years comprehensive maintenance. (vi) This contract shall be operative for the period of three years after expiry of defect liability period only for the purpose of comprehensive maintenance. (vii) In case of non function of Lift recovery shall be effected after the defect is noticed or notified either in writing or through a social media message by GE or his rep in terms of PS clauses mentioned in the tender.
Som Projects Pvt. Ltd.
MAHINDER PAL CONSTRUCTIONS PVT LTD
SOOD ASSOCIATES PVT LTD
Idustrial products India
Hariom Projects Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid