Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.0 L+₹1.4 L (6.10%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹27.4 L+₹4.8 L (21.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹34.1 L+₹11.5 L (51.0%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹36.9 L+₹14.3 L (63.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹69,000
Closing Date
29 Feb 2024, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
CRTN REPAIR OF CIGI PUMPNG PIPELINE INCL ATENDNG BREAKDOWN DAILY COMP MAINTOF VALVES AND LT PANL UG CABL LT FEDR BOXE LT CABL ILUMIN SYSTM INT ELEC LIGTNG PROTN ERTHNG STORG WATER HEATER AND OTHR ALIED WORK AT OTG BHDORYA COMX AREA GE S PKT
2024_MES_640626_1
GES/PKT/T-54/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹69,000
Yes
22 Jun 2024
3 Feb 2024
2 Mar 2024
3 Feb 2024
29 Feb 2024
19 Feb 2024
Amount
M&L for rectification of existing defective run lead joints including burning and removing the old defective lead joints and providing new lead joints with all required materials and testing the joints for leakages for 80 mm dia CI/DI pipes complete all as directed(Note:Earth work shall be measured separately)
All as per Item No. 1 above but for 100 mm dia
All as per Item No. 1 above but for 150 mm dia
All as per Item No. 1 above but for 200 mm dia
M/L for replacing unserviceable sluice valve spindle made out of EN-8 steel with check nut made out of brass/bronze material including replacing perished gland packing, rubber gasket, bolts and nuts suitable for 80mm dia sluice valves all as directed :-
All as per Item No. 5 above but for 100 mm dia sluice valve
All as per Item No. 5 above but for 150 mm dia sluice valve
All as per Item No. 5 above but for 200 mm dia sluice valve
S&F in replacement for Cl sluice valve, non-rising type conforming to IS-14846, sutiable for 150mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
M & L for CI pipe special of class 'A' and 'B' like tee's bend sockets, collar's of jointing coupling etc of any type(flanged or socket/spigot type )all as specified or new position with the help of connecting pieces for sizes upto 200 mm dia CI pipe line all as directed
M/L for replacing unserviceable 200 mm dia cast iron pipe with spigot & socketed ends centrifugally cast class LA 150 mm bore ISI marked suitable for lead joint in any length laid in trenches complete all as specified and directed by Engr-in-Charge. (ExcavationC & lead joints shall be measured and paid separately).
All as per Item No. 11 above but for 150 mm dia
All as per Item No. 11 above but for 100 mm dia
All as per Item No. 11 above but for 80 mm dia
S&F in replacement for Cl sluice valve, non-rising type conforming to IS-14846, sutiable for 200 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.0 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
All as per above item no. 15 above but 150 mm dia but PN 1.0
All as per above item no. 15 above but 100 mm dia but PN 1.0
All as per above item no. 15 above but of size 80 mm dia but PN 1.0
Supply, Fixing, Testing connecting air release valve of size 80 mm dia with 2 air outlet Kinetic design with isolating valve as per IS 14845 including dismantling of unserviceable Air release valve on 150 to 200 mm dia CI/DI pipeline all as specified and as directed
S&F in repair Cl swing check NRV conforming to IS-5312, sutiable for 100 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
S&F in repair Cl swing check NRV conforming to IS-5312, suitable for 150 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
M&L for fixing in repair 200 mm dia pipe Y type Dirt box (strainer) made out of CI with necessary washout arrangement complete including necessary additions & alterations to pipe incl cutting, gaskets & GI nut bolts & washers etc complete of following sizes:- Note:- CI/MS pipe/ Specials if required will be measured & paid separately.
All as per above item no.22 above but of 150 mm dia pipe
S&F for 20 mm dia bore gun metal gate valve with iron wheel head screwed both ends for iron pipe of size including dismantling old one.
All as per above item no.24 above but 25 mm dia bore
All as per above item no.24 above but 40 mm dia bore
All as per above item no.24 above but 50 mm dia bore
All as per above item no.24 above but 80 mm dia bore
S&F in repair High density polyethylene 20 mm dia pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches/ on floor/ walls etc complete all as directed including dismantling old defective pipe lines. Note: The rate quoted deemed to be inclusive of all fittings necessary for fixing the pipe to GI pipes wherever required.
All as per above item no.29 above but 25 mm dia
All as per above item no.29 above but 40 mm dia
All as per above item no.29 above but 50 mm dia
Taking up and down old/unservicable 20 mm dia bore GI tubing with fittings of the following bore bore complete all as specified and directed. (Earth work will be measured and paid under respective items of sch 'A').
All as per above item no.33 above but 25 mm dia bore
All as per above item no.33 above but 40 mm dia bore
All as per above item no.33 above but 50 mm dia bore
All as per above item no.33 above but 80 mm dia bore
Supply and lay in trenches / on roof / on wall 20 mm dia bore steel water tubing galvanised medium grade with all fittings of sizes incl dismantling old one
All as per above item no.38 above but 25 mm dia bore
All as per above item no.38 above but 40 mm dia bore
All as per above item no.38 above but 50 mm dia bore
All as per above item no.38 above but 80 mm dia bore
M/L for carrying out physical, chemical & Bacteriological analysis all as per IS 10500:2012 for Drinking water sample of the Fresh water Pump Houses at various locations from approved laboratory .Note : The rate quoted deemed to inclusive of collecting water sample in Sterilised bottle/PVC container & submitting the same for testing.
M&L for attending break down of pipe line bursting/cracks including excavation in hard / dense soil with the use of Earthmoving machinery / labour and taking out old CI /GI/MS defective / misaligned water pipe line of size 200/150/100/80 mm dia bore carefully after discon-nection of joints to a length up to 8 mtr and create bund with excavated earth and dewatering / bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs, returning filling and removal of surplus soil / excavated material with the help of excavator / proclainer all as directed by Engineer-in-Charge. NOTE : (a) M/L for Lead Joints/ spares / CI /GI specials will be measured and paid separately. (b) The rate is deemed to excluding CI / GI/MS pipe, Specials, lead joints etc will be measured and paid separately under relevant Schedule Items. (c) The rate is deemed to include Cost for tool and plant and transportation required for attending the repair work. (d) Disconnecting / dismantling/ cutting the existingpipe line is included in the quoted rate. (e) The rate is inclusive of earth work complete including returning & refilling in any type of strata complete. (f) The breakdown shall be attended within 4 Hrs of intimation round the clock and time of restoration shall be maximum of 8 Hours. The additional manpower required to complete the job in quoted rate is deemed to be included in the quoted.
Repair to GI pipe lines of size 20 to 50 mm bore dia and repair to leaked joints of pipe line complete including replacement of GI fitting i.e union,nipple & sockets if required including excvation and taking up & down required cutting & threading refixing in position in trenches & all as directed.
M&L for Construction of valve chambers of internal size not less than 1000 mmx1000mm x1000 mm with 15 cm thick solid concrete block masonary, block casted using PCC 1:3:6 type C-1mix built in cement and sand mortar 1:4 ,10 mm plaster to thick internal surface and external surface up to 15 cm below ground level and top of floor in CM 1:4 finished even and smooth without using extra cement 15 mm thick, MS sheet cover including 40x40x3 mm MS angle frame embedded in 150 mm thick PCC 1:2:4 type B-1,with 25x6 mm flat iron hold fast,handles,hinges with locking arrangements, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface and earth work in type of soil & disposal of surplus soil to a distance n.exc.50 m.
S&F in repair Rubber gasket joint suitable for 200 mm bore cast iron/DI pipes/ Sluice valve/NRV/ARVs all as specified and directed.
S&F in repair Rubber gasket joint suitable for 150 mm bore cast iron/DI pipes/ Sluice valve/NRV/ARVs all as specified and directed.
S&F in repair Rubber gasket joint suitable for 80 mm bore cast iron/DI pipes/ Sluice valve/NRV/ARVs all as specified and directed.
M&L PCC 1:4:8 type -D2 using 40mm graded aggregate in fdn filling and mass complete for pipe line supports or any indicated position all as specified and directed by Engr-in-charge.
S&F and laying ductile iron pipe, socket & spigot with bulb type rubber tyton gasket and jointing material as per standard complete of class K-7 of 200 mm dia sizes complete in trenches/ on pedestals etc complete mortar lining (CML) and outside black bitumen coating etc, complete all as specifide and directed. Note: ( Earth work includes excavation, returning & filling and removal, DI fittings will be measured and paid separate where required).
All as per Srl item No 51 above but for 150 mm dia
All as per Srl item No 51 above but for 100 mm dia
All as per Srl item No 51 above but for 80 mm dia
S&F in replacement aviation LED light die cast aluminium alloy housing red coloured polycarbonate dome & accessories including LED lamp complete, commissioning & testing complete all as specified and directed.
M&L for repair/servicing to over head water level indicator gauge complete with replacement of floot valve steel 200mm, Pully as per site requirement,steel pulling wire,fixing clumps etc and applying two coats of super enammeled black paint over a coat of red oxide paint on whole scale and rewriting of existing marking with super enammeled white paint to scale of overhead tank /sumps etc complete all as specified and directed. Note-: (i) Rates are to be including charges of hiring T & P. (ii) Contractor shall be responsible for care and safety of person deployed.
Supply only water testing kit (Residual chlorine reagent-1) including testube, droper etc complete all as specified and directed by Engr- in-Charge
Supply only water testing solution (Residual chlorine reagent-1) all as specified and directed by Engr- in-Charge
S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 400 A rated, All MCCB's should have Company Made Spreaders Links all as specified and directed by Engr- in-Charge.
S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 250 A rated. All MCCB's should have Company Made Spreaders Links all as specified and directed by Engr- in-Charge.
S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 200 A rated. All MCCB's should have Company Made Spreaders Links all as specified and directed by Engr- in-Charge
S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 160 A rated. All MCCB's should have Company Made Spreaders Links all as specified and directed by Engr- in-Charge
S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 50 KA, 630 A rated, All MCCB's should have Company Made Spreaders Links all as specified and directed by Engr- in-Charge.
Disconnecting the delivery line and providing dummy plate with nut, bolts to avoid water leakages and M&L for taking out vertical turbine pump /submersible pumpset of any make of capacity 20 HP to 50 HP from the tubewell/borewell carefully complete with column pipe for inspecting the condition of column pipe, pumpset & flat submersible cable etc complete all per site requirement complete all as specified and directed. Note:(i) The cost inclusive of necessary T&P of removing vertical turbine/submersible pumpset carefully without any damages to pump, motor, shaft, column pipe and casing. Any damages shall be beared by the Contractor at his own cost. (ii) The rate inclusive of dismanlting of motor of Vertical turbine pump set.(iii) The M/L for repairs to pumpsets/ column pipe/cable if required & measured and paid separately under relevant Schedule.
Lowering vertical turbine pump /submersible pumpset of any make of capacity 20 HP to 50 HP inside the tubewell/borewell carefully complete with column pipe and other connected parts and including replacement of nut ,bolts, washers, gasket of suitable size all per site requirement and rec-connection with delivery line with nut ,bolts, washers, gasket of suitable size all as specified and directed. Note:(i) The cost inclusive of necessary T&P of lowering vertical turbine/submersible pumpset carefully without any damages to pump, motor, shaft, column pipe and casing. Any damages shall be beared by the Contractor at his own cost. (ii) The rate inclusive of re-connection of motor of Vertical turbine pump set.
Strip opening of 3 phase AC submersible motor, taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including PVC seal (water proof compound) and thrust bearing as per requirement of existing size and make, re-assembling the motor and testing complete of capacity 20 to 50 HP motor.
Taking out worn out bearing/ bush sleeves from the submersible motor of capacity 30 to 50 HP and providing new stainless steel, turning and polishing of bushes complete including checking of allingment complete in all respect all as specified and directed.
Strip opening of 3 phase AC turbine pump set, taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including PVC seal (water proof compound) and thrust bearing as per requirement of existing size and make, re-assembling the motor and testing complete of capacity 20 to 50 HP motor.
Taking out worn out bearing/ bush sleeves from the turbine pump of capacity 20 to 50 HP and providing new stainless steel, turning and polishing of bushes complete including checking of allingment complete in all respect all as specified and directed.
S&F in replacement of thrust bearing plate along with disc of motor of capacity 20 HP to 50 HP
S&F in replacement of oil seal of motor of capacity 20 HP to 50 HP.
Dismantling the submersible pumping set bowl assembly/motor of any make for carrying out repair and replacement of worn out parts by strip opening with all parts such as bowl casing, impellers, pump shaft, bushes neck ring etc.and machine work such as welding, turing, re-facing where required and replacing of parts of pump of 4 to 9 stages, size 150mm, of capacity 20 HP to 50 HP capacity. Note: - Spares parts and their fixing shall be paid separately under the respective item of schedule 'A'
S&F in replacement of pump shaft of stainless steel suitable for submersible pump set up to 9 stages including threading, cutting to required size all as specified and directed.
S & F in replacement of gun metal/Stainless Steel impellers of suitable size for bowl assembly of submersible pumping set as per site requirement for suction, discharge and intermediate bowls complete all as specified and directed.
S & F in replacement of cast iron casing suction/discharge/ intermediate with studs.
S & F in replacement of shaft seal of rubber all as specified.
S & F in replacement neck ring of bowls suction/discharge/ intermediate
S & F in treplacement of gun metal bush of bowls all as specified
S & F in replacement of rubber bushes of bowls assembly of suitable, make and model as per existing for suction and discharge bowls.
S & F in replacemnt of shaft coupling with key stainless steel of suitable sizes, type, make and model as per existing all as specified and directed.
S & F in replacemnt of stainless steel middle/ distance bush of suitable size all as required at site and directed.
S & F in replacemnt of stainless steel impeller key all as specified and directed.
S & F in replacement of studs with nuts all as directed.
Supply and fixing of mild steel column pipe coupling 100 mm dia, heavy duty threaded or flanged all as specified and directed.
Supply and fixing line shaft bearing retainer of gun metal with rubber bushes for column pipe 150 mm dia all as specified and directed.
Cutting and removing worn out threaded portion of mild steel column pipe heavy duty and re threading the same up to specified length to match with socket of size 150 mm dia.
Cutting and removing worn out threaded portion mild steel/stainless steel line shaft of any dia, length and rethreading the same up to specified length to match with existing coupling all as specified and directed.
S & F new bolts,nuts and washers in places of existing worn out/unserviceable bowl bolts.
S & F Mild steel column pipe for submersible pump set, 125 mm dia, 5 mm thick and 3 mtr. Long duly screwed/welded flanged on both sides with bolts & nuts to mild steel flange including rubber joints all as specified and directed.
Supply and fixing submersible cable 16 Sqmm copper 3 core all as specified and directed by Engr-in-charge.
Suppply only chlorination treatment with high stable Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) packing in 45 kg drum complete all as specified and directed by Engr-in-Charge.
S&F in repairs submersible pump controller type in sheet enclosure for maximum motor output 50 HP/37.5 KW with suitable size relay for AC -3 duty, 415 V 50 Hz, 3 Phase AC supply with overload, Single Phasing, Phase reversal, Phase imbalance, auto restart features, IP 54 enclosure complete with Voltmeter & Ammeter , LED indication lamps, push buttons etc complete.
S&F in repairs submersible pump starter oil immersed type in sheet enclosure for maximum motor output 30 HP/24 KW with relay max range 30 to 50 Amps suitable for AC -3 duty, 415 V 50 Hz, 3 Phase AC supply with ,IP 54 enclosure complete with, push buttons etc complete.
S&F in repairs submersible pump starter oil immersed type in sheet enclosure for maximum motor output 50 HP/37.5 KW with suitable size relay for AC -3 duty, 415 V 50 Hz, 3 Phase AC supply with ,IP 54 enclosure complete with , push buttons etc complete.
S&F in repair single phase preventor relay with timer for auto restart option with protection features against single phasing, phase reversal, phase unbalance etc complete with control wiring all as directed.
M&L for rewinding of existing unsv 3 Phase, 5 HP/ 3.75 KW , 50 Hz, 2800 RPM induction motor any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading and making all electric connections including taking out and refixing at site all as specified and directed.
S&F in repair electronic timers suitable for fully automatic star delta starter panel suitable for 240/360/415 V AC supply operation with timer range 3 to 30 Sec, 12 to 120 Sec complete with control wiring all as directed.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
All as per Item No. 98 above but exceeding depth 1.5 mtr and n exceeding 3 mtrs
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Laying only old bricks retrieved from item No.105 of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
All as per Item No. 105 above but of size 16 x 04 core
All as per Item No. 105 above but of size 25 Sqmm 4 core
All as per Item No. 105 above but of size 35 Sqmm 3.5 core
All as per Item No. 105 above but of size 50 Sqmm 3.5 core
All as per Item No. 105 above but of size 70 Sqmm 3.5 core
All as per Item No. 105 above but of size 95 Sqmm 3.5 core
All as per Item No. 105 above but of size 120 Sqmm 3.5 core
Supply and Repair/Replacement of laying/ jointing GI Pipe light grade 40mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
Supply and Repair/Replacement of laying/ jointing GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
M&L for Horizontal Boring/ Cutting of Road/Foot Path for using through 40/80mm bore pipe for cable protection and finishing PCC after Boring/Cutting of road/Foot path, complete all as specified and as directed.
Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.
Supply and Repair/Replacement for weather proof flat twin core 10 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.
Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 63 AMP MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate.
Supply and Repair/Replacement of MCB SPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement of MCB TPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge
Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 25 Sqmm to 50 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 70 Sqmm to 120 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 10 Sqmm to 95 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 120 Sqmm to 400 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply only Alumunium thimble(lugs) for stright through joint of size suitable for connecting cable of size 10 Sqmm to 95 Sqmm complete all as specifed and directed by Engr-in-Charge.
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 40 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 50 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.
Disconnectiong, dismentling and taking down carefully single pointed air termination copper/ aluminium rod incl GI Pipe any size incl nuts & bolts and seggregating U/s or serviceable parts incl removing from site or setting aside for reuse
Disconnecting, dismentiling and taking down carefully aluminium strip of any size up to 32 x 6 mm complete with saddles, GI tubing insulators and seggregating U/s or serviceable parts incl removing from site or setting aside for reuse
Disconnecting, dismentiling and taking down carefully copper strip of any size up to 20 x 3.15 mm complete with saddles, GI tubing insulators and seggregating U/s or serviceable parts incl removing from site or setting aside for reuse
Fixing only aluminium strip retrived from item No 02 above
Fixing only serviceable aluminium termination rod retrived from item No 01 above
Fixing only serviceable copper termination rod retrived from item No 01 above
S&F in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated location for loop earthing etc. with GI strip 32x6mm including dismantling old ones.
S&F air termination single pointed aluminium rod 12mm dia and 300 mm long for fixing on GI pipe medium grade 20mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
M&L for plain Cement concrete 1:2:4 type B-1, (Using 20 mm graded aggregate) as in foundation block for fixing GI pipe for installation of air termination rod etc. complete all as specified Note:- Unit rates includes for provn of form work for rough finished surfaces and finishing the exposed surfaces with 5 mm thick rendering in CM 1:3 all specified.
S&F GI pipe medium grade 20 mm dia for fixing Aluminium strip 25x3.15 mm on roof for lightening protection duly drilling 2 Nos holes on Aluminum strip and GI pipe on one end and fixing with screws/suitable size of bolts & nuts complete all as specified. Note: GI Strip required will measured and paid separately.
M&L earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of GI and GI strip protected by provision of GI medium grade pipe 40mm bore, 20mm dia GI medium grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Disconnicting and taking down old unserveable geyser of any size and make deposting it to MES store and Supply and fix water heater storage vertical type, SS tank, polycarbonate body electrical operated, capacity 25 litres.BEE 5 star rated duly fixed on wall through proper anchoring, grouting with the help of suitable nuts and bolts, and making good all the disturbed surface all as specifed and directed by the Engr In charge.
Supply and fixing sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
Supply and draw sub main wiring in repairs of two run 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 2.5 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
M&L for GI tubing medium grade of 15 mm dia complete all as specified and directed.
Cutting existing steel tubing for alteration including screwing in position for branch connecting size 15/20/25mm bore complete.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm suitable for hot and cold water all as specified and directed
S&F brass angle valve, cromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm dia.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15 mm dia all as specified and directed
S&F in replacement iron clad, with double door 4 way IP-54, 1K-09 protection, cement sprill prptector sutable for MCCB as incommmer AC 415 Volts three pole with thermal release adjustable type (80% to 100%) and MCB as outgoing complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 ple 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at sit or directed. ( Outgoing MCB will be measured speparately)
S&F SPN 40 to 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
S&F GI tubing light grade ISI marked with requisite fittings laid in trenches or crossing roads/paths/culverts/along poles/walls complete all as specified and directed for 50 mm dia size.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Material, labour , testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 10 Sqmm to 25 sqmm 3½ or 4 core with working voltage 1100 volts.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
VIRAT CONSTRUCTIONS
VIJAY KUMAR LAKHNI
M/S SHRI RAM BUILDERS
Jay Ann Construction Company
satpal and brothers
M/S SHAKTI ELECTRIC WORKS
JAI DURGA CONSTRUCTION CO
M/S CHAMAN LAL GUPTA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .