| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.3 Cr | 1 | Accepted-AOC Being lowest |
| 2 | 2₹1.3 Cr+₹1.5 L (1.09%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹1.3 Cr+₹1.5 L (1.09%) | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹1.4 Cr+₹2.4 L (1.80%)Rejected-Finance | ₹1.4 Cr+₹2.4 L (1.80%) | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹1.4 Cr+₹4.7 L (3.53%)Rejected-Finance | ₹1.4 Cr+₹4.7 L (3.53%) | 4 | Rejected-Finance Not being lowest |
| 5 | 5₹1.4 Cr+₹10.7 L (8.02%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | ₹1.4 Cr+₹10.7 L (8.02%) | 5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | M/s SCHOLASTIC ENTERPRISES L5 | BHARAT ELECTRICAL TRADERS L2 | R D Bansal L1 | M/s Trade Linker Associates L3 | JAZZCON ENGINEERS PVT LTD L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking out power transformer of capacity 3150 KVA, 33/11 KV from its position for replacement, on plinth /2pole / 4pole or any other structure by disconnecting & opening HV, LV Electrical connection, earthing connection along with following other works :-
(a) Transportation of transformer from site to GE(East) office yard by making necessary arrangement of T&P (Crane, recovery vehicle, tripoid to be arranged by the contractor as directed). | 2 | Each Job | 12,000 ₹24,000 | 5,000 ₹10,000 | 4,000 ₹8,000 Lowest | 20,000 ₹40,000 | 10,000 ₹20,000 |
| 2.00 | Supply and installation of copper wound transformer step down, outdoor type complete with first filling of IS:335 ISI marked filtered & dehydrated transformer oil and another standard fittings/accessories HT 33 KV, secondary 11 KV, 3 phase, all as per IS: 2026 of capacity 3150 KVA and following item included-
(a) 17 position on load tap changer (OLTC) (tapping range +5% to -15% in steps of 1.25 % each) with remote tap cubical changer (RTCC) panel & automatic voltage regulator (AVR) with Vector group Dyn-11, with standard fittings - 01 set
(b) HV bare bushing
(c) LV cable box
(d) Buchholz relay (having contacts for trip)
(e) Oil temperature indicator (having contacts for trip)
(f) Winding temperature indicator (having contacts for trip)
(g) Marshalling box (having TTB, heater, lamp, door switch & MCB)
(k) pressure release valve (having contacts for trip) complete all as specified and directed. The following standard fittings/accessories are included as- | 2 | Each Job | 70,00,000 ₹1,40,00,000 | 65,30,000 ₹1,30,60,000 | 64,30,000 ₹1,28,60,000 Lowest | 66,50,000 ₹1,33,00,000 | 67,75,000 ₹1,35,50,000 |
| 2.01(a) Fitting alonwith Transformer 01. NAME, RATING & DIAGRAM PLATE 1 No. 02. EARTHING TERMINALS 2 Nos. 03. LIFTING LUGS 04 Nos. 04. OIL LEVEL INDICATOR (FLUSH TUBE) 1No. 05. OIL DRAIN VALVE WITH PLUG 1 No. 06. OIL FILTER VALVE WITH PLUG (on & above 160 KVA) 1 No. 07. CONSERVATOR WITH OIL FILLING HOLE WITH CAP 1 No. 08. THERMOMETER POCKET 1 No. 09. OIL TEMPERATURE INDICATOR (HAVING CONTRACT FORM ALARM & TRIP) -01 No. 10. WINDING TEMPERATURE INDICATOR (HAVING CONTRACT FOR ALARM & TRIP) - 1 No. 11. SILICAGEL BREATHER 1 No. 12. REMOVABLE INSPECTION OPENING ON COVER - 1 No. 13. EXPLOSION VENT (If PRV Not Opted) 1 No. 14. BIDIRECTIONAL C.I. ROLLERS - 4 Nos. 15. ARCHING HORN SET (Only for HV Bare Bushing Type Transformer) 3 Nos. | ||||||||
| 2.02(b) Fittings alongwith OLTC- 01. NAME, RATING & DIAGRAM PLATE 1 No. 02.ON LOAD TAP CHANGER (OLTC) 1 No. 03. EARTHING TERMINAL 2 Nos. 04. LIFTING EYE BOLTS 3 Nos. 05. AIR RELEASE PLUG 1 No. 06. WINDOW FOR TAP NUMBER 1 No. 07. OIL DRAIN CUM FILTERING VALVE WITH PLUG 1 No. 08. OIL FILLING CUM FILTERING VALVE WITH PLUG 1 No. 09. CONSERVATOR WITH OIL FILLING HOLE WITH CAP 1 No. 10. SILICAGEL BREATHER 1 No. 11. REMOVABLE MANUAL CRANK HANDLE TO OPERATE OLTC 1 No. 12. REMOVABLE INSPECTION OPENING WITH COVER 1 No. 13. OIL SUREGE RELAY 1 No. Note :- (i) Stand by transformer will be provided by the contractor within 24 hour of failure by his own arrangement to regularize the electric supply. Cost of transportation, replacement, refixing, rent charges and necessary operrational requirements for stand by transformer are deemed to be inclusive of quoted rates by the contractor. No extra will be paid to contractor to make such stand by arrangements. (ii) The contractor alongwith OEM must ensure the serviceability of the tripping system and safety for the transformer before installation. (iii) Stand by transformer will be provided by the contractor within 24 hour of failure by his own arrangement (iv) If the contractor failed to provide standby transformer, then recovery of Rs.30000.00 per day and max of Rs.200000.00 for one month. | ||||||||
| 3.00 | M&L for earthing complete with galvanized iron earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 4.00 M below normal ground level ) with top edge of the plate not less than 3.00 M below normal ground level , connected to and including galvanised iron strip 32x6mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. | 8 | Each Set | 4,500 ₹36,000 Lowest | 6,000 ₹48,000 | 4,500 ₹36,000 Lowest | 6,000 ₹48,000 | 6,800 ₹54,400 |
| 4.00 | Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified and directed. | 2 | Each | 3,500 ₹7,000 | 4,000 ₹8,000 | 2,200 ₹4,400 Lowest | 5,000 ₹10,000 | 7,200 ₹14,400 |
| 5.00 | Supply and fix cable jointing kit for 11 KV grade cable for out door termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified and directed. | 2 | Each | 4,000 ₹8,000 | 4,000 ₹8,000 | 2,200 ₹4,400 Lowest | 5,000 ₹10,000 | 7,600 ₹15,200 |
| 6.00 | M&L for chemical earthing with copper earth plate electrode 900x600x5mm burried directly in earth pit not less than 4.7 mtr below normal ground level and complete size of pit 1.6 mtr x 0.60 m , earth plate connected to copper strip 50x6 mm by means of copper/brass nut, bolt duly brazed earth strip protected with 65 mm bore light grade GI pipe from electrode and upto and including the earth test point of gun metal/ phosphorous bronze of size 75x75x25 mm, 20 mm bore watering pipe, medium grade GI pipe including funnel , wiremess providing alternate layer of 15 cm each charcoal salt and magnesium suplhate layer upto 1.20mtr and including excavation , returning in filling , removal of surplus oil to a distance not exceeding 50m , PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate RCC Cover 40 mm thick in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm dia MS deformed bars @ 100 mm CYC both ways including MS handle of 12 mm dia round bar etc to be placed on and including angle iron frame made of section 40x40x3 mm of angle iron complete all as specified.NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. | 4 | Each Job | 70,000 ₹2,80,000 | 75,000 ₹3,00,000 | 94,000 ₹3,76,000 | 30,000 ₹1,20,000 | 26,000 ₹1,04,000 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
1 Dec 2025, 6:00 pmClosed
HQ CWE Agra
112, Taj Road, Agra Cantt
SPL REPAIR / REPLACEMENT AGAINST BER POWER TRANSFORMER 3150 KVA, 33/11 KV WITH CONNECTED ACCESSORIES UNDER GE (EAST) AGRA
2025_MES_736685_1
84408/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Agra
MES contractors enlisted for Class B and above and category b(iii) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE EAST AGRA
₹2.2 L
21 Jan 2026
3 Nov 2025
8 Dec 2025
3 Nov 2025
1 Dec 2025
24 Nov 2025
3 Nov 2025 - 10 Nov 2025
Amount
Dismantling and taking out power transformer of capacity 3150 KVA, 33/11 KV from its position for replacement, on plinth /2pole / 4pole or any other structure by disconnecting & opening HV, LV Electrical connection, earthing connection along with following other works :- (a) Transportation of transformer from site to GE(East) office yard by making necessary arrangement of T&P (Crane, recovery vehicle, tripoid to be arranged by the contractor as directed).
Supply and installation of copper wound transformer step down, outdoor type complete with first filling of IS:335 ISI marked filtered & dehydrated transformer oil and another standard fittings/accessories HT 33 KV, secondary 11 KV, 3 phase, all as per IS: 2026 of capacity 3150 KVA and following item included- (a) 17 position on load tap changer (OLTC) (tapping range +5% to -15% in steps of 1.25 % each) with remote tap cubical changer (RTCC) panel & automatic voltage regulator (AVR) with Vector group Dyn-11, with standard fittings - 01 set (b) HV bare bushing (c) LV cable box (d) Buchholz relay (having contacts for trip) (e) Oil temperature indicator (having contacts for trip) (f) Winding temperature indicator (having contacts for trip) (g) Marshalling box (having TTB, heater, lamp, door switch & MCB) (k) pressure release valve (having contacts for trip) complete all as specified and directed. The following standard fittings/accessories are included as-
(a) Fitting alonwith Transformer 01. NAME, RATING & DIAGRAM PLATE 1 No. 02. EARTHING TERMINALS 2 Nos. 03. LIFTING LUGS 04 Nos. 04. OIL LEVEL INDICATOR (FLUSH TUBE) 1No. 05. OIL DRAIN VALVE WITH PLUG 1 No. 06. OIL FILTER VALVE WITH PLUG (on & above 160 KVA) 1 No. 07. CONSERVATOR WITH OIL FILLING HOLE WITH CAP 1 No. 08. THERMOMETER POCKET 1 No. 09. OIL TEMPERATURE INDICATOR (HAVING CONTRACT FORM ALARM & TRIP) -01 No. 10. WINDING TEMPERATURE INDICATOR (HAVING CONTRACT FOR ALARM & TRIP) - 1 No. 11. SILICAGEL BREATHER 1 No. 12. REMOVABLE INSPECTION OPENING ON COVER - 1 No. 13. EXPLOSION VENT (If PRV Not Opted) 1 No. 14. BIDIRECTIONAL C.I. ROLLERS - 4 Nos. 15. ARCHING HORN SET (Only for HV Bare Bushing Type Transformer) 3 Nos.
(b) Fittings alongwith OLTC- 01. NAME, RATING & DIAGRAM PLATE 1 No. 02.ON LOAD TAP CHANGER (OLTC) 1 No. 03. EARTHING TERMINAL 2 Nos. 04. LIFTING EYE BOLTS 3 Nos. 05. AIR RELEASE PLUG 1 No. 06. WINDOW FOR TAP NUMBER 1 No. 07. OIL DRAIN CUM FILTERING VALVE WITH PLUG 1 No. 08. OIL FILLING CUM FILTERING VALVE WITH PLUG 1 No. 09. CONSERVATOR WITH OIL FILLING HOLE WITH CAP 1 No. 10. SILICAGEL BREATHER 1 No. 11. REMOVABLE MANUAL CRANK HANDLE TO OPERATE OLTC 1 No. 12. REMOVABLE INSPECTION OPENING WITH COVER 1 No. 13. OIL SUREGE RELAY 1 No. Note :- (i) Stand by transformer will be provided by the contractor within 24 hour of failure by his own arrangement to regularize the electric supply. Cost of transportation, replacement, refixing, rent charges and necessary operrational requirements for stand by transformer are deemed to be inclusive of quoted rates by the contractor. No extra will be paid to contractor to make such stand by arrangements. (ii) The contractor alongwith OEM must ensure the serviceability of the tripping system and safety for the transformer before installation. (iii) Stand by transformer will be provided by the contractor within 24 hour of failure by his own arrangement (iv) If the contractor failed to provide standby transformer, then recovery of Rs.30000.00 per day and max of Rs.200000.00 for one month.
M&L for earthing complete with galvanized iron earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 4.00 M below normal ground level ) with top edge of the plate not less than 3.00 M below normal ground level , connected to and including galvanised iron strip 32x6mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for out door termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified and directed.
M&L for chemical earthing with copper earth plate electrode 900x600x5mm burried directly in earth pit not less than 4.7 mtr below normal ground level and complete size of pit 1.6 mtr x 0.60 m , earth plate connected to copper strip 50x6 mm by means of copper/brass nut, bolt duly brazed earth strip protected with 65 mm bore light grade GI pipe from electrode and upto and including the earth test point of gun metal/ phosphorous bronze of size 75x75x25 mm, 20 mm bore watering pipe, medium grade GI pipe including funnel , wiremess providing alternate layer of 15 cm each charcoal salt and magnesium suplhate layer upto 1.20mtr and including excavation , returning in filling , removal of surplus oil to a distance not exceeding 50m , PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate RCC Cover 40 mm thick in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm dia MS deformed bars @ 100 mm CYC both ways including MS handle of 12 mm dia round bar etc to be placed on and including angle iron frame made of section 40x40x3 mm of angle iron complete all as specified.NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
BHARAT ELECTRICAL TRADERS (BID ID -3486210)
M/s Trade Linker Associates (BID ID -3486872)
JAZZCON ENGINEERS PVT LTD (BID ID -3486945)
M/s SCHOLASTIC ENTERPRISES (BID ID -3483953)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.12 MB
TENDERDOC.pdf
Tender Documents • 0.47 MB
AppxG.pdf
Additional Documents • 0.06 MB
BOQ_824860.xls
BOQ • 8.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .