Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance FIRST FOOR SCF 1 SECTOR 17 FARIDABAD FARIDABAD FARIDABAD HARYANA 121002 | FARIDABAD | HARYANA | 121002 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹41.7 L
EMD Value
₹83,500
Closing Date
14 Feb 2024, 3:00 pmClosed
Executive Engineer (ED-III)
DSIIDC, OFFICE OF THE EXECUTIVE ENGINEER (ED-III) Technical Centre Building, Wazirpur Industrial Area, Delhi 110052
Servicing and repairing of Air-Cooled HVAC Plant having capacity of 2X150TR (in all respect) installed at PSK, Laxmi Nagar, Delhi.
2024_DSIDC_253302_1
NIT No.- 01/23-24(Recall)
Open Tender
Miscellaneous Works
Works
90 days
PSK, Laxmi Nagar
As per tender document
12 documents required · 12 mandatory
₹0
₹83,500
23 Feb 2024
6 Feb 2024
14 Feb 2024
6 Feb 2024
14 Feb 2024
6 Feb 2024
Amount
Supply installation testing and commissioning of LG make Air cooled Screw chiller plant part. material below mentioned for Air Cooled Screw Chiller Plant No- 1. i) 6/8 Copper & 1 1/8 Copper Pipe
ii) Header of 2 nos Condenser Coil
iii) Drier Core
iv) Drier Filter 1/2
v) Oil Filter
vi) Compressor Oil
vii) Condenser Coil Service
viii) Refrigerant R134
Supply installation testing and commissioning of LG make Air cooled Screw chiller plant part material below mentioned for Air Cooled Screw Chiller Plant No- 2. i) Condenser Coil (Unit model - MCAW018CA21)
ii) 6/8 Copper & 1 1/8 Copper Pipe
iii) Header of 2 nos Condenser Coil
iv) Drier Core
v) Drier Filter 1/2
vi) Oil Filter
vii) Compressor Oil
viii) Condenser Coil Service
ix) Refrigerant R134
Supply Installation testing and commissitoning of pump Motor 15HP (Make ABB/ Bharat Bijli). i) Chilled water Pump Motor, 15 HP 1435 RPM, IE-2 or IE-3 Type.
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handing units made of 25mm thick panels consisting of per plasticized G.I. casing of thickness 0.8 mm outside layer and 0.8 mm inside layer with polyurethance foam (PUF) insulation factory injected between them by injection moulding machine, completed with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep. fitter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415+_ 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia, dial type pressure gauges (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge value wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. i) 28900 CMH
Double Skinned Vertical Floor Mounted, Air Handling Units :- Part Material as below. Make Of Coil - ZECO (AHRI certified as per test standard ARI – 410 & UL certified for safety). Coil Casing / Blank offs - GI Material Of Tube/Cooling Coil- Copper Tube Diameter (mm / inch) - 12.7 mm / ½” O.D. Thickness of tube/ Cooling Coil (SWG / mm) - 25 SWG / 0.50 mm and cooling coil section is of 6 row deep. Header Material - Copper Header with MS adaptor Thickness & M aterial of fins -0.15 mm Plain Aluminum No. of Fins per inch (FPI) - 11/12 AIR FLOW (CFM) - 16000 /Coil, Cooling Coil Size- Fin Height-1524mm, Fin Length-1950mm approx.
AIR FLOW (CFM) - 4000/Coil, Cooling Coil Size- Fin Height-635mm, Fin Length-1171mm approx.
AIR FLOW (CFM) - 7500/Coil, Cooling Coil Size- Fin Height-952.5mm, Fin Length-1464mm approx.
AIR FLOW (CFM) - 10000/Coil, Cooling Coil Size- Fin Height-1206.5mm, Fin Length-1540mm approx.
AIR FLOW (CFM) - 12000/Coil, Cooling Coil Size- Fin Height-1206.5mm, Fin Length-1850mm approx.
AIR FLOW (CFM) - 30000/Coil, Cooling Coil Size- Fin Height-1016mm, Fin Length-2744 mm approx.
AHU Motor - 7.5KW, IE-2 or IE-3 Type
AHU Motor - 1.5KW, IE-2 or IE-3 Type
AHU Motor - 3.7KW, IE-2 or IE-3 Type
AHU Motor - 5.5KW , IE-2 or IE-3 Type
AHU Motor - 11KW, IE-2 or IE-3 Type
S K Engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .