| Sl No | Description | Qty | Unit | KULBHUSHAN AGGARWAL L3 | Vijay Kumar Contractor and Engineers L1 | M/S Vijay Punj Constructions L4 | Ashoka Engineers L2 | dinesh enterprises L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type soil n. exc. 1.5 Mtr in width and not exceeding 1.5 Mtr in depth, n.exc 10 Sqm on plan and getting out all as required for laying of cable/ poles complete all as specified and directed. | 729 | Cum | 75 ₹54,675 | 60 ₹43,740 | 80 ₹58,320 | 80 ₹58,320 | 50 ₹36,450 |
| 2.00 | Excavation in trenches in soft/hard soil n. exc. 1.5 Mtr in width and exc. 1.5 m in depth but not exc. 3.00 m in depth and getting out all as required for laying of cable/ poles complete all as specified and directed. | 0.5 | Cum | 200 ₹100 | 100 ₹50 | 80 ₹40 | 140 ₹70 | 60 ₹30 |
| 3.00 | Excavating in trenches in chequered tiles/ Interlocking tiles/ Hard rock, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n. exc 1.5 m in depth and getting out complete all as specified and directed. | 5.4 | Cum | 120 ₹648 | 120 ₹648 | 80 ₹432 | 70 ₹378 | 60 ₹324 |
| 4.00 | Excavation in Road/ floor/ wall cutting of size width 20 CM and depth 30 CM for inserting of GI/RCC pipe for protection of cable including making good the disturbed surface as existing surface | 90 | RM | 100 ₹9,000 | 200 ₹18,000 | 100 ₹9,000 | 70 ₹6,300 | 60 ₹5,400 |
| 5.00 | Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required complete all as specified and directed. | 476 | Cum | 25 ₹11,900 | 20 ₹9,520 | 5 ₹2,380 | 30 ₹14,280 | 5 ₹2,380 |
| 6.00 | Removing excavated material to a distance not exceeding 50 m and deposting where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. | 252 | Cum | 25 ₹6,300 | 20 ₹5,040 | 5 ₹1,260 | 30 ₹7,560 | 5 ₹1,260 |
| 7.00 | Supply and laying unreinforced precast cement concrete cable cover, class HV, type 1 with peak, size 300mm x 180mmx 40mm for protection of cable abutting each laid dry flat width equal to the length of cable cover complete all as specified and directed. | 194 | Each | 42 ₹8,148 | 25 ₹4,850 | 25 ₹4,850 | 22 ₹4,268 | 14 ₹2,716 |
| 8.00 | M&L for brick, sub class 'B' old size well burnt laid flat & dry, for cable protection, abutting each other with width of protection equal to length of brick complete all as specified and directed. | 20,400 | Each | 3.5 ₹71,400 | 4 ₹81,600 | 3.88 ₹79,152 | 4 ₹81,600 | 3.5 ₹71,400 |
| 9.00 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Note:- Volume of pole/strut embedded shall be deducted for the purpose of payment. | 3.5 | Cum | 2,500 ₹8,750 | 3,000 ₹10,500 | 680 ₹2,380 | 2,300 ₹8,050 | 2,200 ₹7,700 |
| 10.00 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed.
Note:- Volume of pole/strut embedded shall be deducted for the purpose of payment. | 1.25 | Cum | 4,000 ₹5,000 | 3,200 ₹4,000 | 680 ₹850 | 2,300 ₹2,875 | 2,300 ₹2,875 |
Updated dates
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
23 Oct 2025, 6:00 pmClosed
GE (South) Mamun
GE (South) Mamun, MES Complex, Mamun Cantt, Pathankot
As specified in BOQ and Tender Documents
2025_MES_732563_1
GE(S)/M-56/2025-26
Open Tender
Civil Works
180 days
GE (South) Mamun, MES Complex, Mamun Cantt, Pathan
As per NIT
10 documents required · 10 mandatory
₹500
Yes
GE (South) Mamun
₹87,000
Yes
19 Jan 2026
25 Sept 2025
31 Oct 2025
25 Sept 2025
23 Oct 2025
9 Oct 2025
Amount
Excavation in trenches in any type soil n. exc. 1.5 Mtr in width and not exceeding 1.5 Mtr in depth, n.exc 10 Sqm on plan and getting out all as required for laying of cable/ poles complete all as specified and directed.
Excavation in trenches in soft/hard soil n. exc. 1.5 Mtr in width and exc. 1.5 m in depth but not exc. 3.00 m in depth and getting out all as required for laying of cable/ poles complete all as specified and directed.
Excavating in trenches in chequered tiles/ Interlocking tiles/ Hard rock, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n. exc 1.5 m in depth and getting out complete all as specified and directed.
Excavation in Road/ floor/ wall cutting of size width 20 CM and depth 30 CM for inserting of GI/RCC pipe for protection of cable including making good the disturbed surface as existing surface
Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 m and deposting where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Supply and laying unreinforced precast cement concrete cable cover, class HV, type 1 with peak, size 300mm x 180mmx 40mm for protection of cable abutting each laid dry flat width equal to the length of cable cover complete all as specified and directed.
M&L for brick, sub class 'B' old size well burnt laid flat & dry, for cable protection, abutting each other with width of protection equal to length of brick complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed. Note:- Volume of pole/strut embedded shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed. Note:- Volume of pole/strut embedded shall be deducted for the purpose of payment.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
Taking out old unservicable under ground LT/HT XLPE/ PVC cable of any size from trenches/ wall/ roof/ pipe/ DB including taking out of brick layer of cable protection complete all as specified and as directed. Note : Excavation and earth work shall be inlcuded in this item.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 16 Sqmm x 4 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 25 Sqmm x 3.5 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 35 Sqmm x 3.5 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 50 Sqmm x 3.5 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 70 Sqmm x 3.5 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 95 Sqmm x 3.5 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 120 Sqmm x 3.5 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable, with aluminium conductor of size 240 Sqmm x 3.5 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed. Note : Excavation & Earth work shall be measured and paid separately.
Supply and laying in trenches or fixed to wall/pole or passing through pipe or road crossing, testing and commissioning of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty ) with aluminium conductor, 11KV (Earthed) grade, suitable for earthed system, with aluminium conductor of size 185 Sqmm 3 Core including taking down unserviceable HT cable of any type/size/description, etc complete all specified and directed (Note : Excavation & Earth work shall be measured and paid separately).
Supply only plug receptacle connector (ESSMA) suitable for 5KW, 6 sqmm copper conductor cable etc, complete all as specified and directed.
Supplying, jointing and connecting cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 240 sqmm to 300 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting straight through joint, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 240 sqmm to 300 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Material and labour for cable termination outdoor, heat shrinkable type suitable for XLPE cable of size 120 Sqmm to 185 sqmm 3 core with working voltage 11000 volts (Earthed) with jointing material and accessories including testing complete all as specified and directed.
Supply and laying 40 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with complete all as specified and directed.
Supply and laying 50 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with complete all as specified and directed.
Supply and laying 80 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with complete all as specified and directed.
Supply, installation, commissioning and testing outdoor type LT Panel dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size. All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement,all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgear compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 1000 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size not less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates, suitable for complete and including the following:-
(i) MCCB 4 pole, 415 volts, 250 amp rating, Adjustastable Thermal Magnetic (TM) type with rupturing capacity 36 KA - 01 No. as incomer (ii) MCCB 4 pole, 415 volts,fixed type, 200 amp rating with rupturing capacity 25 KA - 02 Nos. for outgoing (iii) Indicator set RYB -01 Set of 3 pcs only (iv) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio. (v) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, commissioning and testing outdoor type LT Panel dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size. All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement,all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgear compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 600 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size not less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates, suitable for complete and including the following:-
(i) MCCB 4 pole, 415 volts, 400 amp rating, Adjustastable Thermal Magnetic (TM) type with rupturing capacity 36 KA - 01 No. as incomer (ii) MCCB 4 pole, 415 volts, fixed type, 160 amp rating with rupturing capacity 25 KA - 01 No. for outgoing (iii) Manual change over switch of capacity 400Amps, 4 Pole, 415 Volts with front handle operating in ON position, OFF position and other source ON position (Three Positions) incl electrical connnections complete. - 01 No. (iv) Indicator set RYB -01 Set of 3 pcs only (v) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio. (vi) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, commissioning and testing outdoor type LT Panel dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size. All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement,all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgear compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 600 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size not less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregatesd, suitable for and complete and including the following :-
(i) MCCB 4 pole, 415 volts, Adjustastable Thermal Magnetic (TM) type, 400 amp rating, rupturing capacity 36 KA - 01 No. as income. (ii) MCCB 4 pole, 415 volts, fixed type 315 amp rating, microprecesser based energy with rupturing capacity 25 KA - 01 No. for outgoing (iii) MCCB 4 pole, 415 volts, fixed type, 200 amp rating, microprecesser based energy with rupturing capacity 25 KA - 02 No. for outgoing (iv) MCCB 4 pole, 415 volts, fixed type, 100 amp rating, microprecesser based energy with rupturing capacity 25 KA - 01 No. for outgoing (v) Indicator set RYB -01 Set of 3 pcs only (vi) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio. (vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
S&F industrial switchgear aluminium busbar chambers of 2000 A alongwith sheet metal enclosure of required size with (IP-65 protection) with CRCA sheet of size 3.15mm, 6 way for LT cable 300 Sqmm including Indicator for three phase, 440 Volt inlcuding clamp, cable gland & angle iron stand 50x50x6 mm size with PCC work etc complete with connected items and accessories all as specified and directed.
S&F industrial switchgear aluminium busbar chamber 800 A alongwith sheet metal enclosure of required size with (IP-65 protection) with CRCA sheet of size 3.15mm with MCCB fixed type, 400 amp rating with rupturing capacity 25 KA - 03 No as Incoming, indicator for 3 phase, 440 Volt, 6 way LT Cable any size inlcuding clamp, cable gland & angle iron stand 50x50x6 mm size with PCC work etc complete with connected items and accessories all as specified and directed.
S&F in repairs industrial switchgear busbar chambers of 200 A, of size 600x600x150mm, 6 way for LT cable any size including Indicator for three phase, necessary PCC/Wall mounted work, cable gland, complete all as specified and directed.
M&L for ACSR conductor (Weasel conductor 6 x 2.59 + 1(Al) x 2.59 Steel), drawn straight horizontal as over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables, complete all as specified and directed. Note:- 3% for sag shall be considered for measurement and payment purpose.
Supply and erecting in repairs in true vertical position steel tubular swaged poles of 9.0 metres long, type 410 SP-31 9mtr complete with cast iron base plate, goose neck bracket, finial taper plug, bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting upto 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer, including demolition of PCC, complete all as specified and directed. Note:-Excavation & earth work and concrete in foundation and pedestal shall be measured and paid for separately.
S&F sub main wiring with 10 sqmm copper conductor cable multistrand, FRLS PVC sheathed two run (as phase and neutral) and run 10 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in and including rigid non metalic PVC conduit complete all as specified and directed. Note:- The rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete all as specified and as directed.
Dismantling cross-arms of mild steel channel or angle sections etc. complete all as specified and as directed.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Dismantling stay assembly with connecting items etc. complete all as specified and as directed.
S&F stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 20mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 2009 or directed. Note: Excavation, PCC, safety wire and loop type insulators will be measured separately.
Material and labour for galvanized stay strand of size 7/4 mm, complete all as specified and directed.
S&F loop type insulator large size with overall dimensions (90 x140) mm with clearance of hole 25.5 mm vitreous white brown or green complete all as required at site or directed.
S&F Shackle insulators porcelain, vitreous, white, brown of green insulator including one set of glavanized mild steel section of straps 31x3mm dia of bolt 12mm alongwith iron washers and one galvanized iron nut 75mm height, 95mm dia for 1100 volts grade all as specified and directed
Dismantling of Earthings of any type after disconnection of Transformer/ LT panels/ DG Set complete all as specified and as directed.
Material and labour for earthing with copper plate electrode of size 60cmx60cmx3.15mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to copper earth lead strip of size 20x3mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI medium grade watering pipe with funnel and wire mesh, PCC pit 1:3:6 type C1 in chamber with precast RCC cover 50mm thick in cement concrete 1:2:4 Type B1 reinforced with welded steel wire fabric or XPM (wt not less than Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe light grade protection pipe upto 7.5m and adequate qty of charcoal dust and salt in each layers of 15cm all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-in-Charge. Note: Item includes the cost of earth lead and GI protection pipe upto 7.5m. Copper strip beyong 7.5m shall be measured and paid separately.
Dismantling of old PCC Platform of transformer/ DG Set of any size after removing of connections of Earthings of transformer or DG Set and shifting of transformer or DG Set etc complete all as specified and as directed.
Material and labour for construction of platform for transformer of size 3.00m X 2.50m X1.20 m high from natural ground level with PCC (1:4:8) in foundation, 100mm thick PCC (1:2:4) type B1 at top portion of platform, brick work with cement mortar (1:4) and complete 15mm thick rendering in CM (1:4) for exposed surface including neccessary MS work (i.e chain link fencing and gate fixed on angle iron post) on the top of platform around transformer up to height 1.2 m and one coat of white wash on plastered surface shown on drawing No CEPZ/TD/350/08 sheet 1/2, complete all as specified and directed.
Material and labour for anti-climbing device; spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole including one coat of primer and under coat and one finishing coat of aluminium paint including preparation of surface complete all as specified and directed.
Supply and fixing of danger notice board with pressed vitreous painted plate fabricated out of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamp bolts and nuts of approved size for HT 25X20cm size complete all as specified and directed.
Material and labour for dismantling of old PCC Poles 11 mtr after unbinding of HT Cable, HT lightening arrestor, GOD etc. complete all as specified and as directed.
Supply and erection in vertical position steel tubular swaged Poles, type 410, SP-55 (11.0 meter) with 300mm x 300mm x 6mm with cast iron plate continuously welded to pole all as specified including factory painted with two coats black bituminous paint internally through out and externaly for embeded portion and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surfaces after errection complete with synthetic enamel paint of black and yellow alternate strips of 30cm upto 1.5 mtr from the top of coping complete all as specified and directed . NOTE : PCC in foundation, coping, excavation and earth work shall be measured and paid separately under respective items.
S&F HT lightening arrestor metal oxide type (gap less) heavy duty single pole suitable for rated system voltage of 12 KV and working rated arrestor voltage of 9 KV with normal discharge current of 10 KA complete with all fitting transmission class, discharge capacity 10 kilo Amp all as per IEC 99.4 effectively connected with earthy system complete all as specified and directed by Engr-in-Charge. Note:- Test certificate for lighting arrestor shall be supplied without which no separate payment shall be made.
S&F Switch air break, gang operated, triple pole with drop out fuses and 12 insulators for outdoors, mechanically operated mounted on insulator and MS channels frame, with operating mechanism 25 mm dia G.I medium grade pipe worked from ground level with locking arrangement for current rating 400 Amps, 11 KV including electrical connection complete all as specified and directed by Engr-in-charge.
Dismaintling unserviceable DG Set 250 KVA Engine from alternator installed at site, loading in the vehicle by crane and sent to the local work shop at Pathankot area for check the engine and connected parts of DG Set and replacement of the following spare parts as listed at Srl 63.01 to 63.21 (to be measured as Supply only) after repairing the said DG set, re-loading and installing at site as directed including testing and commissioning the DG set all as specified and directed.
Supply only piston assembly
Supply only piston Pin
Supply only piston Bearing
Supply only Main Bearing
Supply only Oil Pump Repair
Supply only Connecting Rod Bearing
Supply only Crank Shaft Repair
Supply only Cam Shaft Repair
Supply only Head Grinding
Supply only Block Grinding
Supply only Jain Kit
Supply only Cylinder Liner
Supply only Valve Guide
Supply only Valve Inlet
Supply only Valve Exhaust
Supply only Valve Spring
Supply only Push Rod
Supply only Rocker Arm
Supply only Timing Gear
Supply only Piston Bearing
Supply only Main Bearing
Disconnecting and dismantling of DG set of 250 KVA alongwith LT Panel/AMF Panel carefully without damaging any parts and move it to the another site with in 1 km range and making all necessary connections like earth connections, electric supply wire connection, battery charging connections etc complete for fully functioning and testing the DG set complete all specified and directed.
Disconnecting and dismantling of Transformer 200 KVA alongwith LT Panels/APFC Panels carefully without damaging any parts and move it to the another site with in 1 km range and making all necessary connections like earth connections, LT/ HT Cable connections etc complete for fully functioning and testing the transformer complete all specified and directed.
Surface excavation n. exceeding 30 cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified and directed.
M& L for Cement concrete, Type B-2, 1:2:4 (Using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed
Use and Waste of form work to sides of concrete foundation, footing base of columns and raft beams sides and soffits (if any) of plinth beams for rough finished flat surfaces complete all as specified and directed.
Ashoka Engineers (BID ID -3457263)
KULBHUSHAN AGGARWAL (BID ID -3450833)
M/S Vijay Punj Constructions (BID ID -3452675)
dinesh enterprises (BID ID -3451797)
Bidder Name
KULBHUSHAN AGGARWAL
Vijay Kumar Contractor and Engineers
Ashoka Engineers
M/S Vijay Punj Constructions
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
56TENDERDOCUMENT.pdf
Tender Documents • 0.84 MB
BOQ_820219.xls
BOQ • 4.25 MB
Download all tender documents and submit your bid