Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹40.5 LAdmitted-Finance | -38.99% | ₹40.5 L | L1 | Admitted-Finance |
| 2 | L2₹44.5 LAdmitted-Finance GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | -32.99% | ₹44.5 L | L2 | Admitted-Finance |
| 3 | L3₹47.4 LAdmitted-Finance C 344 GALI NO 2 BLOCK C WEST KARAWAL NAGAR DELHI 110094 | NORTH EAST | DELHI | 110094 | -28.70% | ₹47.4 L | L3 | Admitted-Finance |
| 4 | L4₹53.1 LAdmitted-Finance | -20.02% | ₹53.1 L | L4 | Admitted-Finance |
Tender Value
₹66.4 L
EMD Value
₹1.3 L
Closing Date
23 Feb 2026, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Electrical Renovation/repair work at the office of District Magistrate, Old Delhi Erstwhile Central , 14 Daryaganj, New Delhi-110002
2026_PWD_287113_1
235/EEE/PWDDHC,NDC2025-26
Open Tender
Electrical Works
90 days
New Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹1.3 L
27 Feb 2026
17 Feb 2026
23 Feb 2026
17 Feb 2026
23 Feb 2026
17 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 1.01) Group C
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit etc as required a) 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a)25 mm
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 3 Module (100 mmX75 mm)
b) 6 Module (150 mmX75 mm)
c) 8 Module (125 mmX125 mm)
d) 12 Module (200 mmX150 mm)
Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etcas required. a) 5/6 Ampers switch
b) 15/16 Ampers switch
c) 3 pin 5/6 Ampers socket outlet
d) 6 pin 15/16 A socket outlet
e) Bell push
f) Telephone socket outlet
Supplying and fixing of 5 Ampers to 32 Ampers rating, 240/415 Volts, 10 kA, breaking capacity “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required a) Single pole
b) Double pole
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 9.01) 6 way (4 + 18), Double door
9.02) 8 way (4 + 24), Double door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required. (a) 40 A
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 12 way (4 + 36), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required. A) 63A
Supplying, installation, testing & commissioning of 400mm sweep size Oscillating type wall fan of with fan regulator and fixing with the help of dash fasteners including connections etc as required.
Supplying, installation, testing & commissioning of energy efficient 1200 mm sweep size ceiling fan, including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on fan box etc. as required.
Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
Supplying, Installation, Testing and Commissioning of 300 mm sweep size, 1400 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
Supplying, Installation, Testing & Commissioning of double door Refrigerator Top Mount Freezer with Digital Inverter Technology of 327 litres capacity minimum 3 Star operating at 230v, 50 HZ eco friendly refrigerant gas etc as required
Supplying, Installation, Testing & Commissioning of Single door Refrigerator of 192L 4 Star Single Door Refrigerator With Base Drawer minimum 4 Star operating at 220-230v, 50 HZ eco friendly refrigerant gas etc as required
Supplying, Installation, Testing & Commissioning of following sizes (Screen size) 4K Ultra HD Smart QLED TV, having Wifi& Bluetooth connectivity with inbuilt speaker of 20 watt (Record, Pause, Rewinding, Live Shows), connectivity minimum 2 HDMI port & 1 USB Port,with heavy duty MS type fixed stand with complete all accessories etc as required. (a) 43” Inch. QLED Display
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim a) 8 - 10 watt
b) 12 -15 watt
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) 21.01) 18-22 watt
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 150 watt
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 23.01) 36 watt
Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on Wall/surface etc complete as required. (a) 3 X 10 Sq.mm
24.01) 3 X 16 Sq.mm
24.02) 4 X 25 Sq.mm
24.03) 3.5 X 35 Sq.mm
24.04) 3.5 X 120 Sq.mm
24.05) 3.5 X 150 Sq.mm
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: FCC, CE marked, UL/EN, RoHS and relevent MTCTE (TEC)/BIS compliance/certification as applicable, etc complete as required. 25.01) (a) 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min.
Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. (a) Copper Patch Cords of length 1m (3ft)
b) Copper Patch Cords of length 3m (10ft)
Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required.
Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D.
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. a) 1 run of cable.
b) 2 run of cable.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.a) 9U Rack
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 32.01) 1.5 TR with 5 Star BEE Rating
32.02) 2 TR with 5 Star BEE Rating
Providing & Laying of refrigerant copper piping of size 1/4" or 3/8" & 5/8" diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc all as per Direction of Engineer-in-charge .
Supplying & Drawing of 3x4 sqmm size of PVC insulated &pvc sheathed copper conductor round multicore flexible cable for indoor to outdoor and upto nearest power point i/c providing suitable copper lugs connection etc as required.
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB completewith connections, testing and commissioning etc. as required.
Supplying and fixing of following capacity automatic voltage stabilizer suitable for above said units complete as reqd. (a) 5 KVA [Input-165 - 280 V] [ Output- 195-245 V]
Providing and fixing of M.S. outdoor, floor/ wall mounting powder coated stand suitable for 2.0 Ton capacity STAC/Cassette type AC outdoor unit complete as reqd.
Providing & fixing of PVC drain pipe of size 25 mm dia medium gauge drain pipe with necessary fitting such as nipple, reducer, clamp on surface / recess i/c cutting the wall and making good the same complete as reqd.
Supplying, Installation, Testing & Commissioning of WiFi 7 Router | 4K/8K Streaming 6.5 Gbps | 1× 2.5 Gbps WAN/LAN + 3× 1 Gbps LAN Ports etc as required
CENTRAL CONTROL SERVERSupplying Installation Testing Commissioning of Central Control Server System comprising of Intel® Xeon® CPU E5-2640 x64 (or better) compatible with dual and quad core processors, Windows 11(Professional, Enterprise, Ultimate, 64 bit), Windows Server 2013 R2 (Standard, Enterprise, 64 bit) 16 GB or more, Video card and monitor capable of displaying at 1024 x 768 resolution or better, Latest Microsoft Licence Version Operating System Loaded with MSOFFICE 2019 Professional, Word, EXCEL, Power Point, Outlook Express, Microsoft Team official version lifetime licences suitable for running BMS software complete etc. as required.
Supplying, Installation, Testing & Commissioning of All-in-One computer system having followingspecifications:- Processor:- Intel® Core™ i7- 13th, Generation processor Memory :- 16 GB DDR5-3200 MHz RAM(2X8GB) Storage :- 1TB PCIe NVMe M.2 SSD Display :- 27'' inch (68.58cm) diagonal FHD(1920X1080) etc complete as required.
Supplying, installation, testing and commissioning of Laser Jet multifunction A4 Printer i.e., print, scan, copier, autoduplex printing , Wireless Printing etc complete as required.
Supplying, installation, testing and commissioning of 650VA/360 Watt UPS with 12V 7Ah battery operating at 230V, 50Hz etc complete as required.
Supplying, Installation, Testing & Commissioning of Wireless Keyboard and Mouse etc complete as required.
SITC of Video Conference systems Panasonic make having 12X optical/10X Digital Zoom PTZ camera with complete accessories etc as required.
Supplying and fixing of PVC cable management system / wall trunking with cover of following sizes including internal, external, flat single cover and T- cover , end cap and other accessories on the wall so as to make complete etc as required. 46.01) 100 mmx50mm
46.02 50 mm X 50mm
Supplying, Installation, Testing and Commissioning of indoor type LT panel with single door in front suitable for 415 V, 3 Phase, 50 Hz, AC supply fabricated out of 2.0 mm thick CRCA sheet steel for frame work and covers, 3.0 mm thick for gland plates i/c clearing & finishing complete with 7 tank process for powder coating in approved shade having suitable capacity extensible type TPN electrolytic grade aluminium bus bars 500 A of high conductivity, DMC/ SMC bus bar supports, etc complete as required with following switchgear and accessories.size not less than 1875mm H X 2300 mm W X 700 mm deep.Make RS controls and switchgears pvt ltd/Adlec/Tricolite/Core metal krafts. Incoming 1 400A FP MCCB 36KA MICRO PROCESSOR BASED RELEASE WITH SPREADER LINK AND EXTENDED ROTARY HANDLE - 1 nos Incoming 2 250A FP MCCB 36KA MICRO PROCESSOR BASED RELEASE WITH SPREADER LINK AND EXTENDED ROTARY HANDLE - 1 nos changeover switich 400A CHANGEOVER SWITCH - 1 nos Metering VAF meter - 2 nos Led phase indication lamp - 6 nos 06A SP MCB - 6 nos CT 400/5 - 6 nos Main Bus Bar 500 Amp, TPN Aluminium Bus bar Outgoing 125A FP MCCB 25KA THERMAL MAGNETIC BASED RELEASE WITH SPREADER LINK AND EXTENDED ROTARY HANDLE - 4 nos 100A FP MCCB 25KA THERMAL MAGNETIC BASED RELEASE WITH SPREADER LINK AND EXTENDED ROTARY HANDLE - 4 nos 63A FP MCCB 25KA THERMAL MAGNETIC BASED RELEASE WITH SPREADER LINK AND EXTENDED ROTARY HANDLE - 6 nos
Supply, installation, testing and commisioning of 3D (three dimensional) backlit IP 65, letter forms display of approved signage of approved artwork and aspect ratio and minimum 12 swg protruded letter forms cutting to be made by CNC router as per approved size of letters in 04 languages. translucent ISI marked acrylic sheet used for letters fabrication to be of minimum 12 SWG thickness and base sheet to be of minimum 03mm thick ACP sheet suitable to glow with horizontal line array of LED modules fixed at equidistant on suitable spacing firmly on mm thick sunboard sheet. ACP sheet is to be used for boxing up and properly supported by MS pipe structure of size not less than 50x25 mm of minimum 17 SWG thickness. The board should be supported with the MS pipe horizontal member from inside centrally. LED modules must be in conformity to prevailing BIS codes and buld technology SMD LED, lumens output per watt should not be less than 100 Im per watt,CRI>80, life 50000 hrs. color temperature 6500k, light effect cool daylight, startup time<0.5s, IP 65, voltage withstand 190 V-305 V, 50/60 Hz, independent driver with 2.5 Kv surge protection and drver/ power supply unit to be housed in cubicle made outside on signage board on back side with opening or easy maintenance and replacement of power supply daily programmable electronic timer switch minimum 2 KW etc asn reqd. frame 4 feet width 60mm deep 25 mm x 25 mm having thickness not less than 24 SWG SS 304 grade angle iron cladding all around the board as per drawing approved by engineer-incharge.
Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Aluminium lugs for 10 sq. mm cable
Aluminium lugs for 16 sq. mm cable
Aluminium lugs for 25 sq. mm cable
Aluminium lugs for 70 sq. mm cable
Aluminium lugs for 120 sq. mm cable
HDPE PIPE, 63 mm dia
HDPE PIPE COUPLER, 63 mm dia
Aluminium lugs for 150 sq. mm cable
Supplying and fixing of 20Ltrs capacity floor mounted water dispenser having three types of water outlet i.e., Hot, Cold and normal. The cooling capacity of the dispenser shall be 2.5 LPH with cool tank capacity 3.2 ltrs. The refrigerate should be R134, the hot water capacity of the dispenser should be atleast 1 ltr and the dispenser should be operate at 230 Volt, 50 Hz with complete connection as required at site.
Less credit of following unserviceable/Burntout electrical accessories etc. complete as required. (a) Assorted Panel
b) Assorted Cable
c) Assorted Luminaries
d) Assorted DB's
e) Assorted Wire/Conduit
f) Assorted Switch/Socket etc.
g) old rusted assorted size MS Pipe
h) STAC/WTAC
i) Assorted Dispenser
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.95 MB
BOQ_380354.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid