| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM PIN 786191 | DIBRUGARH | ASSAM | 786191 | ₹19.2 L Quoted ₹19.9 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹21.8 LRejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹21.8 L | L2 | Rejected-Finance Being other than Lowest |
| 3 | L3₹22.0 LRejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹22.0 L | L3 | Rejected-Finance Being other than Lowest |
| 4 | L4₹22.1 LRejected-Finance | ₹22.1 L | L4 | Rejected-Finance Being other than Lowest |
| 5 | L5₹22.1 LRejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹22.1 L | L5 | Rejected-Finance Being other than Lowest |
| Sl No | Description | Qty | Unit | M/s PRABIR ENTERPRISE L5 | M/S SINGH TRADERS L1 | M/s Singh enterprises L3 | MAA COMMUNICATION L2 | M/S. UDDUG CONSTRUCTION L6 | ASTRA INFRACON L7 | M H KHAN L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive periodical servicing, repair , maint on monthly basis (minimum twice in a month) visting the site of AFS Mohanbari for smooth proper functioning of the street / flood / High bay lights / Post Top lamp / wellglass fittings/Perimeter light located at any height of pole / walls/ any location including checking, dismanteling, servicing, cleaning, removing dust or dirt and repairing of fittings by replacing defective parts for the trouble free and efficient functioning and testing complete all as specified and directed.
Note:
(i) LED Drivers, Surge protection device, FR PVC cable for connection, GI brackets etc shall be measured and paid seperately under relevant items of this schedule.
(ii) Minor parts like insulation tape, cotton waste, nuts, screw etc shall be deemed to be included in the item quoted rates. | 9 | Each Job | 45,000 ₹4,05,000 | 36,000 ₹3,24,000 | 40,000 ₹3,60,000 | 38,000 ₹3,42,000 | 48,000 ₹4,32,000 | 47,520 ₹4,27,680 | 41,000 ₹3,69,000 |
| 2.00 | Supply only 10 KV surge protection device for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures higher capacity for fixing in repairs complete all as specified and directed. | 4 | Each | 900 ₹3,600 | 850 ₹3,400 | 950 ₹3,800 | 900 ₹3,600 | 980 ₹3,920 | 1,200 ₹4,800 | 990 ₹3,960 |
| 3.00 | Supply only 5 KV surge protection device for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures for fixing in repairs complete all as specified and directed. | 10 | Each | 800 ₹8,000 | 800 ₹8,000 | 900 ₹9,000 | 800 ₹8,000 | 900 ₹9,000 | 1,000 ₹10,000 | 900 ₹9,000 |
| 4.00 | Supply only Drivers for LED street lights / well glass fitting 35W to 60 W, 230 Volts, 50 HZ complete all as specified and directed. | 15 | Each | 950 ₹14,250 | 900 ₹13,500 | 1,100 ₹16,500 | 1,200 ₹18,000 | 950 ₹14,250 | 950 ₹14,250 | 950 ₹14,250 |
| 5.00 | Supply only Drivers for LED Flood light fitting / High Bay light 70W/80W, 230 Volts, 50 HZ complete all as specified and directed. | 4 | Each | 1,400 ₹5,600 | 1,200 ₹4,800 | 1,400 ₹5,600 | 1,400 ₹5,600 | 1,400 ₹5,600 | 1,400 ₹5,600 | 1,400 ₹5,600 |
| 6.00 | Supply only Drivers for LED street lights / Flood light fitting 90W/100W, 230 Volts, 50 HZ complete all as specified and directed. | 4 | Each | 3,800 ₹15,200 | 3,740 ₹14,960 | 4,000 ₹16,000 | 4,000 ₹16,000 | 4,000 ₹16,000 | 4,500 ₹18,000 | 3,850 ₹15,400 |
| 7.00 | Supply only Drivers for LED Street light fitting / High Bay light, 120W / 150 W, 230 Volts, 50 HZ complete all as specified and directed. | 4 | Each | 4,500 ₹18,000 | 4,230 ₹16,920 | 4,500 ₹18,000 | 4,500 ₹18,000 | 4,500 ₹18,000 | 4,800 ₹19,200 | 4,500 ₹18,000 |
| 8.00 | Supply only Drivers for LED Flood light fitting 120W, 230 Volts, 50 HZ complete all as specified and directed. | 2 | Each | 4,600 ₹9,200 | 4,420 ₹8,840 | 4,700 ₹9,400 | 4,600 ₹9,200 | 4,800 ₹9,600 | 4,900 ₹9,800 | 4,600 ₹9,200 |
| 9.00 | Supply only Drivers for LED Post Top Lantern 40W, 230 Volts, 50 HZ complete all as specified and directed. | 1 | Each | 900 ₹900 | 1,500 ₹1,500 | 990 ₹990 | 900 ₹900 | 900 ₹900 | 900 ₹900 | 900 ₹900 |
| 10.00 | Supply only GI Bracket for mounting of Street lights made out of 40 mm GI pipe medium grade 1.5 meters in length bend in shape as required including necessary MS flat iron clamps, nuts and bolts etc complete all as specified and directed. | 8 | Each | 1,700 ₹13,600 | 1,550 ₹12,400 | 1,600 ₹12,800 | 1,700 ₹13,600 | 1,650 ₹13,200 | 1,700 ₹13,600 | 1,600 ₹12,800 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 May 2026, 6:00 pmClosed
GE (AF) Mohanbari
Garrison Engineer (AF) Mohanbari Mohanbari Post Dibrugarh Assam 786012
REPAIR, MAINT AND REPLACEMENT OF PERIMETER LIGHT, STREET LIGHT, FLOOD LIGHT, HIGH MAST LANTERN, HIGHBAY LIGHTS, FLP LIGHTS, NATURE SWITCH AND MISC CONNECTED WORKS AT AF STN MOHANBARI
2026_MES_759534_1
8001/780/E8
Open Tender
Civil Works
270 days
Mohanbari
Class E, category b(i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (AF) Mohanbari
₹40,000
Yes
1 Jun 2026
8 Apr 2026
14 May 2026
8 Apr 2026
13 May 2026
29 Apr 2026
Comprehensive periodical servicing, repair , maint on monthly basis (minimum twice in a month) visting the site of AFS Mohanbari for smooth proper functioning of the street / flood / High bay lights / Post Top lamp / wellglass fittings/Perimeter light located at any height of pole / walls/ any location including checking, dismanteling, servicing, cleaning, removing dust or dirt and repairing of fittings by replacing defective parts for the trouble free and efficient functioning and testing complete all as specified and directed. Note: (i) LED Drivers, Surge protection device, FR PVC cable for connection, GI brackets etc shall be measured and paid seperately under relevant items of this schedule. (ii) Minor parts like insulation tape, cotton waste, nuts, screw etc shall be deemed to be included in the item quoted rates.
Supply only 10 KV surge protection device for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures higher capacity for fixing in repairs complete all as specified and directed.
Supply only 5 KV surge protection device for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures for fixing in repairs complete all as specified and directed.
Supply only Drivers for LED street lights / well glass fitting 35W to 60 W, 230 Volts, 50 HZ complete all as specified and directed.
Supply only Drivers for LED Flood light fitting / High Bay light 70W/80W, 230 Volts, 50 HZ complete all as specified and directed.
Supply only Drivers for LED street lights / Flood light fitting 90W/100W, 230 Volts, 50 HZ complete all as specified and directed.
Supply only Drivers for LED Street light fitting / High Bay light, 120W / 150 W, 230 Volts, 50 HZ complete all as specified and directed.
Supply only Drivers for LED Flood light fitting 120W, 230 Volts, 50 HZ complete all as specified and directed.
Supply only Drivers for LED Post Top Lantern 40W, 230 Volts, 50 HZ complete all as specified and directed.
Supply only GI Bracket for mounting of Street lights made out of 40 mm GI pipe medium grade 1.5 meters in length bend in shape as required including necessary MS flat iron clamps, nuts and bolts etc complete all as specified and directed.
Supply only GI Bracket for mounting of Street lights made out of 25 mm GI pipe medium grade 1.5 meters in length bend in shape as required including necessary MS flat iron clamps, nuts and bolts etc complete all as specified and directed.
Supply only 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 1.5 Sqmm for electrical connections to the street lights fittings ccomplete all as specified and directed.
Supply only 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 2.5 Sqmm for electrical connections to the street lights fittings complete all as specified and directed.
Supply only 1100 Volts heavy duty round sheathed multistranded Five core bright annealed bare copper conductor cable of size 2.5 Sqmm for electrical connections to the high mast lights fittings complete all as specified and directed.
S&F in repair of LED street light fitting 35 / 36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed.
S&F in repair of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed.
S&F in repair of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed.
S&F in repair of LED flood light 50 watt 230 V AC outdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.
S&F in repair of LED flood light 100 watt 230 V AC outdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.
S&F in repair of LED flood light 150 watt 230 V AC outdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.
S&F in repair of LED flood light 200 watt 230 V AC outdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.
S&F in repair of LED Post Top lantern 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.
Supply and fixing in repairs of polycarbonate globe light 12 watt, 230 volts AC, unbreakable with B-22 type holder, IP-65 protection with & including 12W, B-22 type warm white LED bulb complete all as specified and directed.
M&L for repairing and rewinding of High mast motor of capacity upto 3 HP/2.4 KW of any make/model, including removal of existing burnt windings completely and carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete including dismantling and re-assembling of starter, rotor, blades etc all as complete all as specified and directed. Note:- Rate is inclusive of transportation to and fro from MES store/site to civil workshop.
S&F in repair of MCCBs 63/100 Amps 4 pole, 415 V breaking capacity 16 kA , thermal magnetic release including spreader terminals for easy operation and connection complete all as specified and directed.
S&F in repair of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and capacity 10 to 32 Amp complete all as specified and directed.
S&F in repair of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and neutral and capacity 10 to 32 Amp complete all as specified and directed.
S&F in repair of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of Triple pole and capacity 40 to 63 Amp complete all as specified and directed.
S&F in repair power contactor 40 Amps 3 pole ( 1 NO + 1 NC) , 415 Volts AC 50Hz,including connecting with existing system complete all as specified and directed.
S&F in repair of Digital Time switch (5-40) Amps , 240 Volts , AC , Singlephase complete all as specified and directed.
S&F in repair of LED Aviation light luminaire having die-cast aluminium housing with polycarbonate enclosure, driver and LEDs connected in series and parallel combination with better heat dissipation 240 Volts, IP -65 with all accessories complete all as specified and directed.
S&F in repair of LED round Highbay luminaire 80 watt 230 volts with high efficiency, IP 66 in PDC housing suitable for induastrial applications including prewired and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.
S&F in repair of LED round Highbay luminaire 120 watt 230 volts with high efficiency, IP 66 in PDC housing suitable for induastrial applications including prewired and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.
M&L for cleaning the swaged steel tubural street light pole 9 / 11 meters height including GI pipe of street light fitting and prepare surfaces cleaning including scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of aluminium paint and marking of zebra crossings up to a height of 1.5m above the coping with blue and white strips of synthetic enamel paint including writing of pole numbers and two coats colour washing of PCC coping complete all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for trenches for laying underground cables, poles, stay assemblies,pipes and getting out in soft/ loose Soil complete all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for trenches for laying GI pipes, cables, pole, stay used for cable protection and getting out in hard/ dense Soil complete all as specified and directed.
Returning/ filling including spreading, levelling and well ramming in layers not exc 25cm in thick complete all as specified and directed.
Removal of surplus soil to a distance n.exc 50 m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 40 mm bore complete all as specified and directed.
Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and directed. Note:- Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and laying burnt brick sub class 'B' of size 230 x115 x75mm for protection of cable, laying in trenches including taking out old complete all as specified and directed.
Supply and laying Pipes in repairs galvanized iron Light grade for cable protection of size 25 mm bore complete all as specified and directed.
Supply and laying Pipes in repairs galvanized iron Light grade for cable protection of size 40 mm bore complete all as specified and directed.
Taking out old serviceable/ unserviceable cable of size 2/4 core, up to 16 sqmm of any make/ type and keeping aside for the purpose of rerouting/ relaying in new location/ for requisite replacement/ further disposal complete including taking out bricks complete all as specified and directed. Note: Earth work shall be measured & paid separately.
M&L in repair LT UG cable of size 2 core 10 Sqmm aluminium conductor XLPE insulated and sheathed armoured, heavy duty 1100 volts in trenches/poles/surface and connecting with all accessories complete all as specified and directed.
M&L in repair LT UG cable of size 4 core 16 Sqmm aluminium conductor XLPE insulated and sheathed armoured, heavy duty 1100 volts in trenches/poles/surface and connecting with all accessories complete all as specified and directed.
Re-laying of serviceable (as obtained from taking out) cable of size 2/4 core up to 16 sqmm of any make/ type inclung making electrical complete all as specified and directed. Note: Earth work shall be measured & paid separately.
M&L for Straight through joint suitable for cable size 4 core 6 sqmm to 16 sqmm LT UG cable with necessary jointing materials and ferrule including cutting unserviceable portion of cable complete all as specified and directed.
S&F in repair of Rigid non metallic PVC conduit of dia 20 mm including of all tee, bends, elbows, reducers, and fixing such as couplers lock nuts, saddles, pipe hooks ccomplete all as specified and directed.
S&F in repair of HOT moulded (FRP) SMC jucntion box for street light pole with locking arrangementt hinged door with IP -65 protection of size 205 x 255 X 112 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and directed.
M&L for sub main wiring 2 runs of 1.5 Sqmm PVC insulated FRLS cable multistranded copper conductor 1100 V grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed on wall/ ceiling/floors for flameproof application connected upto DB and 1.5 sqmm copper earth wire for earth continuity conductor and connecting to common earth dolly including taking down old complete all as specified and directed. Note :- 3 runs of 1.5 sqmm cable and one length of MS conduit shall be measured as one length.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender.pdf
Tender Documents • 1.48 MB
BOQ_850742.xls
BOQ • 0.91 MB
Amnt.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid