| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-Finance | L1 | Accepted-Finance Inline with the NIT | |
| 2 | L2₹5.9 L+₹61,955.90 (11.8%)Accepted-Finance | L2 | Accepted-Finance Inline with the NIT |
Tender Value
₹5.1 L
EMD Value
₹10,292
Closing Date
5 Nov 2022, 4:00 pmClosed
Executive Engineer (E), BSNL, ED-I, Hyderabad
EXECUTIVE ENGINEER (E), BSNL Electrical Division-I, 6th floor, NW wing, BSNL Bhavan, 5-9-25, Hill Fort Road, Adarsh Nagar, Hyderabad. -500063
Providing EI Fans
2022_BSNL_133502_1
NIT NO 78/ BED-I/ HYD/ 2022-23 dated25 10 2022
Open Tender
Electrical Works
Item Rate
60 days
Mahabubnagar
Please refer Tender documents.
16 documents required · 16 mandatory
₹590
Accounts Officer(Cash),O/o GMTD, BSNL,Sangareddy
₹10,292
20 May 2023
27 Oct 2022
7 Nov 2022
27 Oct 2022
5 Nov 2022
27 Oct 2022
Amount
SH-I :- Supplying and Installation. Wiring for circuit / sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, etc. as reqd. (for UPS points & AC units) a) 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
b) 4 x 1.5 Sq.mm + 2 x 1.5 Sq.mm earth wire
c) 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire
d) 4 x 2.5 Sq.mm + 2 x 2.5 Sq.mm earth wire
e) 2 x 4.0 Sq.mm + 1 x 4.0 Sq.mm earth wire
f) 4 x 4.0 Sq.mm + 2 x 4.0 Sq.mm earth wire
Supplying and fixing of 5 Amps to 32 Amps rating 240/415Volts, "C" Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc., as required. (Make: Havells / Indokopp /MDS Legrand/ other BSNL approved make) (for UPS points) a) Single pole MCBs
b) 32A SPN MCB
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. a) Group 'B'
b) Group 'C'
Supplying and fixinig of 4 feet 18/20W LED tube fitting having luminous flux 1600 lumens minimum suitable for ceiling / wall mounting as read. (M/s Crompton smart Linea/ SS make)
Supplying and fixing of metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc., as required. a) 300mm x 100 mm x 60 mm
b) 100mm x 100 mm x 60 mm
Supplying and fixing of following piano type switch/ socket on the existing switch box/ cover including connections etc., as required. a) 15/16 amps switch
b) 6 pin 15/16 amps socket outlet
c)Electronic step type Ceiling Fan Regulators
d) Supplying and fixing of ceiling Fan Hooks
e) Ceiling fan condenser
Supplying and fixing of 36W lamps in the existing 2x36W recessed CFL fitting etc., as required.
Supplying and fixing of 8 SWG dia GI wire on surface or recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable etc., as required
Supplying and fixing metal box of 180 x 100 x 60 mm deep (Nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in the front including providing and fixing 3 pin 15 amps socket outlet and 15A tumbler/ piano type switch connecting painting etc., as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 1 x 1.5 sq. mm
b) 2 x 1.5 sq. mm
c) 3 x 1.5 sq. mm
d) 6 x 1.5 sq. mm
e) 2 x 2.5 sq. mm
f) 3 x 2.5 sq. mm
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing extra conduit down rod of 120 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450 mm sweep
Supplying of CAT-5 LAN cable in the existing pipe or open surface etc., as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. a) 1 run of cable
b) 2 run of cable
c) 3 run of cable
d) 4 run of cable
e) 5 run of cable
Providing end termination for the existing CAT 5 and CAT 6 wires with RJ45 end termination including crimping with tool, marking etc., as req, M/s Dlink or similar superior make.
Supplying and laying of 2 core 16 Sq Mm weatherproof aluminium wire, PVC sheathed PVC insulated, including providing interconnections at the main distribution panel in power room, near the DB, for extending the supply from quarter 1 to 5, providing aluminium clips/ PVC tags along with GI wire for mechanical strength wherever required, making good the damages done etc as required.
SH-II :- Dismantling works. Dismantling of following type air conditioning units, indoor and outdoor unit in case of split units, from conference hall, DGM chamber, GM chamber, DGM finance, DGM admin section etc. including shifting all the units to ground floor, a) Split type AC units
b) Window type AC units
c) Industrial plug and socket
d) 4kVA voltage stabilizer
Dismantling of the following type of fittings/ switch boards from the ceiling/ surface of wall etc. including disconnecting the supply removing the component, providing tape to the wires etc as required. (UPS boards shall contain 4 switches, 4 socket, and switch board shall contain ceiling fan regulator, 1 socket and control switches
Dismantling of all UPS DB's from 1st, 2nd, 3rd floors, UPS room, including disconnecting the power supply, removing the DB, insulating the open cable, shifting the same to ground floor.
Dismantling of old cash counter table power supply by removing all switch boards, power supply cables, LAN wires etc in main telephone exchange, etc as required
Removal of LAN switch mounting rack from the surface of wall, removing of all installed switches, routers, disconnecting the power supply, LAN wires, handing over the same to the JTO computers etc as required
Dismantling, shifting and re fixing as per site conditions of existing computer power supply boxes consisting of 3Nos switches & 3Nos sockets including testing and commissioning etc., as required.
Dismantling of all the ceiling fans in all the floors from ground to 3rd floor and shifting the same to the telephone exchange, etc as required.
Dismantling all the fittings from the celing / on the surface of wall and shifting the same to the main telephone exchange etc as required.
Dismantling and removing of exhaust fan from the ventilators/ window grills, disconnecting the power supply, removal of nuts and bolts, shifting all the material to ground floor etc., as required. a) 18" Exhaust fan
b) 12" Exhaust fan
Dismantling of audio system along with mic, power supply cords, LAN cables, HDMI cables, removing speakers, amplifiers and handing over the same to the incharge etc as required.
Removal of 2No of DC cables of size 90 Sqmm single core from the CM section room, the route of the cable is from first floor -> planning section -> BDM room -> Ground floor -> battery room ->Power plant room, the cable is to be removed from the cable trays and hand over the cable to the exchange incharge in good working condition.
Removal of all old recovered LAN cables from the planning section room, disconnecting the power supply from power cables etc. handing over the wires to JTO incharge etc., as required
Tansport of material from the ground floor to the main telephone exchange 2nd and 1st floor including hiring labour for transport, loading and unloading and vehicle for transport etc., as required the work is to be carried out in two phases. (Office will be shifted in 2 phases, ground and first and later 2nd and third as the material is recovered in two phases)
SH-III :- ITC of recovered Items. Installation testing and commissioning of old recovered switch boards consisting of 1No socket along with control switch, ceiling fan regulator and control switchs, on the existing wall / partition including making good etc as required.
Installation testing and commissioning of old recovered switch rack suitable for mounting the router, switch, including extending power supply to the rack, making holes for mouting the same, making good the damages done etc as required.
ITC of ceiling fan including wiring the down rods of standard length (up to 30 cm) with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc., as required.
Fixing of existing 20 W retrofit LED tube in the existing T8 FL Tube fitting including modifying the internal wiring of the fitting etc., as required.
Fixing of old recovered single phase DB on the surface of wall including making hole for mounting the same, making good the damages done etc., a required.
SH-IV :- ITC of Split AC units. Installation testing and commissioning of 1.5TR Split type AC units in suitable location including fixing of indoor unit on wall/ existing angle iron stand, out-door unit on the wall/ existing angle iron frame, laying of existing copper pipe lines, leak testing, gas releasing, interconnections, making opening in wall, making good the damages, etc, as required. (Conference hall-5Nos, GM Chamber-2Nos, DGM Chamber-1 No.)
Supplying and fixing extra copper pipe line both 1/4" for liquid line and 5/8" for vapour line with PVC flexible pipe including providing foaming along the gas line necessary clamping etc, as required.
Providing and fixing of 25mm PVC pipe for drain of AC unit including clamping etc., as required.
Supplying and laying 3Core 2.5Sqmm flexible copper wire along with refrigerant pipe etc, as required.
Supplying and fixing of 2" dia steel reinforced flexible pipe for mechanical protection of the copper refrigerant pipe provided along with the split ac unit etc., as required.
V S ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .