Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
13 Dec 2023, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
jyoti
Providing electrification for Samuday Bhavan in Navalur Gram in Ward no 24 Dharwad Division.
DMA/2023-24/EL/WORK_INDENT7760
DMA/2023-24/EL/WORK_INDENT7760
Open
Electrical
Electronic Documents, First(One Cover)
DMA City Corporation Hubballi-Dharawada
7 documents required · 7 mandatory
₹1,000
₹80,000
6 Dec 2023
6 Dec 2023
13 Dec 2023
Providing electrification for Samuday Bhavan in Navalur Gram in Ward no 24 Dharwad Division.
Open Conduit System
Supplying heavy gauge PVC conduit pipe . dia . mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in ca...
Open Conduit System
Supplying heavy gauge PVC conduit pipe . dia . mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in ca...
Supplying heavy gauge PVC conduit pipe …mm dia .mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The con...
Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The ...
supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement...
Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (c...
Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (c...
Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (c...
Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealedsystem of wiring with specified IS-69...
Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealedsystem of wiring with specified IS-69...
Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealedsystem of wiring with specified IS-69...
Wiring for lighting/power circuit using one of FRLS PVC Insulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealedsystem of wiring with specified IS-6...
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall 3.4....
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall 3.4....
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall 3.4....
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall 3.4....
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall 3.4....
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall 3.4....
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing met...
supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing met...
Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing me...
Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing me...
Supplying and fixing superior quality modular switch mounting polycar bonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing me...
Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing me...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293. 3.6.1)6Amps one way. PWD,Elct, SR-2023-24 Page No. 9 Item code 3.6.1
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293. 3.6.1)6Amps Two way. PWD,Elct, SR-2023-24 Page No. 9 Item code 3.6.2
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293.3.6. 10)6/16Amps universal socket PWD, Elct, SR-2023-24 Page No. 9 Item code 3...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293. 3.6.3)6Amps 3way socket PWD,Elct, SR-2023-24 Page No.9 Item code 3.6.3
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293.3.6.7)16Amps one way Switch PWD, Elct, SR-2023-24 Page No. 9 Item code 3.6.7
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854and IS 1293.3.6.6)600 W Dimmer. PWD,Elct, SR-2023-24 Page No. 9 Item code 3.6.7
Supplying and fixing/replacing of 6/16/32Amps electricalaccessories on existing switch board. 3.14.5) 6A Bakelite Ceiling Rose PWD,Elct, SR-2023-24 Page No. 10 Item code 3.14.5
Supplying and fixing/replacing of 6/16/32Amps electricalaccessories on existing switch board. 3.14.6) 6 Amps Batten holderPWD,Elct, SR-2023-24 Page No. 10 Item code 3.14.7
Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V @ 50/60Hz & Power fact...
Supplying of recess mounting non integral type .LED. W luminaire comprising of pressure decast/extrudedaluminium housing, with spring loaded fase ceiling clamps,Power LEDs with CCT 6500 degree K, CRI ...
Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires...
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double bal...
Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23...
Supplying and fixing of Metal fan hook 1.12) Metal Fan BoxPWD,Elct, SR-2023-24 Page No. 4 Item code 1.13
Supplying of 1440rpm heavy duty exhaust fan with bracketblades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300 mm)PWD,Elct, SR-2023-24 Page No. 30 Item code 6.2.1
Fixing one exhaust fan in the nitch already left in the wall withbolts and nuts and 5 A. ceiling rose with sufficient length of23/0.0076 inch PVC insulated twin core wire.PWD,Elct, SR-2023-24 Page No....
Extra length of GI pipe of class B 19mm dia for down rod PWD,Elct, SR-2023-24 Page No. 57 Item code 13.12
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 5.7.3)63Amps PWD,Elct, SR-2023-24 Page No. 14 Item code 5.7.3
Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.5.20.8)32-40 A 4 pole PWD,Elct, SR-2023-24 Page No. 18 Item code 5.20....
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ca...
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ca...
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ca...
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ca...
Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 ...
Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 ...
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyca...
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 5....
MS box Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, ...
Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which a...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 5.11.2) 100APWD,Elct, SR-2023-24 Page No.15 Item code 5.11.2
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. 5.38 PWD,Elct, SR-2023-24 Page No.19 Item code 5.38
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.5.34 PWD,Elct, SR-2023-24 Page No.19 Item code 5.34
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with ...
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage curr...
LEDLamps Supplying & fixing retrofit type -PL- LED Lamp .WLED linear source with CCT 6500 degree K, CRI greater than 70%.efficacy greater than80 lumen per watt, life greater than 25000 burning hoursan...
Fixing Charges Supplying and Fixing of.mm dia class A GI pipe bracketup to 2 Mtrs long bent at suitable angle and fixing to thisbracket 1x40/2x40 watts fluorescent tube street light fittingof all capa...
Grounding Material Pipe Grounding
GI grounding Pipe,B-class,42mm dia,2.5mtr long 3.2mm thick with bolt,nut,GI strips and washer compleete.Minimum weight of GI pipe:7.3kg
Good Quality well burnt charcoal for grounding purposes packed in non returnable gunny bag of 30 kg each .
Good Quality salt for grounding purposes packed in 50kg gunny bag .
Rod type of earthing using 40mm dia 3 mtr long M.S rod as ground rod,in earth pit of 300mm width and 3300mm depth and using 50X6 mm flat welded to ground rod as terminal is connected to e...
1.1Kv XLPE or Heat resistant PVC insulated,PVC Extruded Inner sheath Armoured LT UG cable as per IS-1554(part-1 )or IS-7098 Part 1,Armouring strip thickness and resistivity as per IS-3975 50...
1.1Kv XLPE or Heat resistant PVC insulated,PVC Extruded Inner sheath Armoured LT UG cable as per IS-1554(part-1 )or IS-7098 Part 1,Armouring strip thickness and resistivity as per IS-3975 10...
GI Pipe B - Class as per IS-1239GI Pipe - 63 mm Dia BESCOM part iii SR, SR2021-22 Sl No 410 Item No 49.06
Heavy Duty Copper Terminal Long Barrel , 50Sqmm Copper Terminal, Apprx Wt: 26 Gm
Brass Cable Gland 25 mm
Brass Cable Gland 45 mm
PVC Pipe as per IS-2509 A. Pipe PVC Pipe - 63 mm Dia
Double Pole TC Set for erection ofTransformer on RCC/PSCC 9 Mtr LongPoles as per IS-1977
For25/63 100 kVA 4/5 Star Rated Transformer on
RCC Pole - 9 Mtr Long, 145 Kg WL - M
H - Frame Set for fixing 11 kV, 200 Amps Single Break
GOS - (For DP structure for providing New GOS for
sectionalisation) - MS
Insulator as per IS-1445 for Ceremic, IS7935 for GI Pin, IEC-61109 for PolymericDISC Insulator 45 kN Porcelain
Insulator as per IS-1445 for Ceremic, IS 7935 for GI Pin, IEC-61109 for Polymeric , 11 kV, 45 kN Polymeric Insulator
nsulator as per IS-1445 for Ceremic, IS 7935 for GI Pin, IEC-61109 for Polymeric ,11 kV, 70 kN Composite/Polymeric Insulator
Turn Buckle (GI) (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)
Anchor Rod using 12 mm rounds/Guy Rod - GI
Guy Wire & GI Wire as per IS-2141 7/10 SWG GuyWire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM
11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018)
11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)
Transparent Alkathine tube 19 mm dia, 2 mm thick in
coils of 30 Mtr
Distribution Transformer - 3 Phase,11kV/433V - Stacked CRGO Core with Oilas per IS-1180 (Part-1): 2014 63 kVA, Aluminum Wdg, Star 2 (5 Star)
LT Distribution Box for Transformer a) LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal)
LT Protection Kit for 63 kVA
1.1 KV Class HR (Heat Resistant) PVC Insulated & UnSheathed Aluminium Wires Multistrand Single Core Lead wires as per IS-694: 2010 PVC Wire - 95 Sqmm
Al Wt: 25 Kg, Total Wt: 36 Kg/100 Mtr Coil
Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm
PG Clamps - Rabbit to Rabbit
For TC Wiring (Dwg No. BESCOM/GM/QS&S/38 Dtd 24.11.2018)
Fish Plate with necessary Clamps,bolts & nuts etc complete (Galvanised)
LT 3 Phase 4 Wire 5-30 Amps Thread Through Type
composite Meter Housing Box consisting of ETV Meter
with AMR comply and LTCT with built in GSM/GPRS
Modem (as per technical specification) upto 100 k...
Anti Climbing Device GI Barbed wire (12 Mtr/Kg)
Lightning Arrester as per IEC-60099-4, 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type
with GROUND DISCONNECTOR(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)
Caution/Danger Board.
Cross Arms (MS & GI) as per IS-1977 ,11 kV, Special 3 Pin Cross Arm - GI
Clamps A Type (MS & GI) as per IS-1977, RCC Pole Clamp - MS(Dwg No. BESCOM/GM/QS&S/30 Dtd 24.11.2018)
49.04 GI Pipe - 40 mm Dia
BESCOM SR2021-22 BESCOM Part IV, Sl No 409 Item No 49.04
DP Set (2 Pole Strucrure Kit) as per IS-1977, For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9
Mtr Long, 300Kg WL - GI
Spiral Earth Electrodes .
ACSR Conductor as per IS-398 (Part - 2/1996), Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 ...
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing , Hard Soil
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth
Digging of Pit for GUY SET ,Hard Soil
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) but us...
Digging Digging of Pit for providing GI Pipe type Earthing
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transform...
Erection of H-Frame.
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring
Erection of 25 to 63 kVA Transformer on Transformer Structure
Fixing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring)
Fixing of LT Protection Kit
Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter & wiring for DTC 25/63 kVA TC
Fixing of GI Barbed Wire (12 Mtr)
Fixing of 3 Nos Lightning Arrestor including wiring
Fixing Danger Board
Erection of 2 Pole Structure using RCC/PSCC Pole 9 to 10 Mtr long
Providing Spiral Earth Electrode type earthing (without charcoal, salt etc.,)
Stringing of conductor Rabbit binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direct...
11 kV, 3x95 Sqmm XLPE UG Cable
Cable Termination Kit Outdoor HS Type Suitable for 95 Sqmm Cable
Cable Termination Kit Outdoor HS Type Suitable for 95 Sqmm Cable
Cable Termination Kit Outdoor HS Type Suitable for 95 Sqmm Cable
Manufactured Sand
RCC Hume Pipe, 2000 mm Long, 150 mm Dia
Collars for RCC Hume Pipe
GI Pipe, 100 mm Dia for drain crossing, cable raising etc.
Route and Joint Indicating Stones
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Laying of cable in trench
11 kV AB Cable Termination installation for 3 Core
Covering the cable with tile
Spreading Sand and forming with Sand round the cable
Laying and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortor complete
Laying of GI Pipe
Fixing of Route Joint Indicating Slab
Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, includ...
Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Single Arm Bracket with 1000 mm Standa...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as p...
Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved ...
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including ro...
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50...
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyca...
1.1Kv XLPE or Heat resistant PVC insulated,PVC Extruded Inner sheath Armoured LT UG cable as per IS-1554(part-1 )or IS-7098 Part 1,Armouring strip thickness and resistivity as per IS-3975 10...
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Laying of cable in Existing Trench/GI pipe/Stoneware/RCC Hume pipe using wooden/Aluminium Rollers as directed by department staff. 2.5 to 25Sqmm. BESCOM SR 2021-22 BESCOM Part IV 11kv Labour Sl No 230...
PVC Pipe 40mm Dia 2.5mm thick PWD Electrical SR 2022-23 [Pg.No:1, I.No: 1.1.4]
49.04 GI Pipe - 40 mm Dia
BESCOM SR2021-22 BESCOM Part IV, Sl No 409 Item No 49.04
Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (Virgin) PVC insulation and she...
Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI / GI or any other pipe using required size of reducer, wiring using suitable wires.PWD Electrical SR 2022-23 [Pg.No:45, I.No: 1...
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equippe...
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - ...
Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which ...
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.5.7.1)16A PWD Electrical SR 2022-23 [Pg.No:10, I.No: 5.7.1]
Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.
Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. PWD Electrical SR 2022-23 [Pg.No:16, I.No:...
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz12/24v D.C. PWD Electrical SR 2022-23 [Pg.No:14, I.No: 5.38]
Supplying and fixing hylum plastic sheet 3mm thick withnecessary nitches for fixing switches, regulators etc., andfixing on existing wood or metal box using N. F. screws
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NAVLUR SAMUDAY.doc
Tender Document • 1.05 MB
format LOC.pdf
Instructions to Tenderers • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .