Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC BHARALICHUK DHEMAJI ASSAM | DHEMAJI | DHEMAJI | ASSAM | ₹1.5 Cr | 1 | Accepted-AOC AOC AWARDED |
| 2 | 2₹1.5 Cr+₹4,532.77 (0.03%)Rejected-AOC WARD NO 1 DHEMAJI TOWN DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | ₹1.5 Cr+₹4,532.77 (0.03%) | 2 | Rejected-AOC REJECTED |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
10 Jan 2024, 11:00 amClosed
Superintending Engineer
North Lakhimpur
Construction of Full Fledged Skill Training Institute for Construction Sector CSTI, Gogamukh, Dhemaji, Assam
2023_PWBNH_34797_1
LBCNL/2023-24/Dhemaji/D-1/11O5
Open Tender
Civil Works - Building
Item Rate
360 days
LAKHIMPUR BUILDING CIRCLE, NORTH LAKHIMPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
₹3.0 L
Yes
11 Jan 2024
19 Dec 2023
10 Jan 2024
19 Dec 2023
10 Jan 2024
19 Dec 2023
Amount
Earth work in evacuation by mechanical means (Hydraulic excavator) / manual means in foundation treanches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S (non Modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and stuttering - All work up to plinth level : 4.1.5 1:3:6 ( 1 cement : coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4 Hot rolled deformed bars
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footing, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girdens, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, piers, Abutments, Posts and Struts
Providing snd lsying in podition specified grade of reinforced cement concrete, excluding the cost of centeribg, shuttering, finishing and reinforcement - All work upto plinth level :5.1.2 1:1.5:3 ( 1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural souces
Reinforced cement concrete work in walls (any thickness0, including attached pilasters, buttresses, plinth and string cources, fillets, columns, pillars , piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttrering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) dedrived from natural sources ; 3 graded stone aggregate 20mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non Modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1. Cement mortar 1:4 (1 Cement: 4 Coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete
Half brick masonry with common burst clay F.P.S> (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 Cement :4 Coarse sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes
Providing & Fxing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimension as per IS code 2767 with Code Description Unit Rate No.271SUB HEAD : 12.0 ROOFING characteristics of good formability and corrosion nresistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex Cap headed self fdrilling/tapping Stainless steel screws M6, 50mm long with 3mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. 9Cost of truss/frame work shall be paid separately). 12.65.1 0.56 mm, Aluminium color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overrall profile width 1092 mm, cover width 1000mm.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertyical frains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary Screws
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of fequired size with necessary screws. 9.9.1.1 35mm thick sqm 4458.40
15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : 13.60.1 Two or more coats on new work
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.2.4 Hot rolled deformed bars
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 :- 1:2:4 ( 1 cement : 2 coarse sand (zone III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources)
Earth work in evacuation by mechanical means (Hydraulic excavator) / manual means in foundation treanches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m 2.8.1 All kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S (non Modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and stuttering - All work up to plinth level : 4.1.5 1:3:6 ( 1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nomial size derived from natural sources)
Brick work with common burnt clay F.P.S. (non Modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1. Cement mortar 1:4 (1 Cement: 4 Coarse sand)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.2.4 Hot rolled deformed bars
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.2 :- 1:4 (1 cement: 4 find sand )
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) for sluice valve, with C.L. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design bricks of class designation 7.5
Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device ( handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 17.1.1 White Vitreous chine Orissa pattern W.C pan of size 580x 440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fitting and brackets, cutting and making good the walls and floors wherever required: 17.4.1 one urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C. I. brackets, 15 mm CP Brass pillars taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous Chine Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing soil, waste and vent pipes 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S & S pipe as per IS: 1729
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.38.1 100 mm dia 17.38.1.1 Sand cast iron S&S as per IS - 1729
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.43.1 100x100x100 mm 17.43.1.1 Sand cast iron S&S as per IS - 1729
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.9.3 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.9.1 :- 15mm Dia
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 18.53.1 15mm nominal bore
Earth work in evacuation by mechanical means (Hydraulic excavator) / manual means in foundation treanches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S (non Modular) bricks of class designation 7.5
Proving and laying in position cement concrete of specified grade excluding the cost of centering and stuttering - All work up to plinth level : 4.1.5 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources )
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.22.4 Hot rolled deformed bars
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footing, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girdens, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, piers, Abutments, Posts and Struts
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2. 1:1.5:3 ( 1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string cources, fillets, columns, pillars , piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Brick work witrh common burnt clay F.P.S. ( non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Half Brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand)
Steel work in built up tubular (round, sqaure or rectangular hollow tubes etc. ) trusses etc, including cutting, hoisting, fixing in positrion and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes
Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing shets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with Code Description Unit Rate No.271SUB HEAD : 12.0 ROOFING characteristics of good formality and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, t&P and sundries etc. complete as per directions of the Engineer-in-charge. (Cost of truss/frame work shall be paid separately). 12.65.1 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width 1092 mm, cover width 1000mm.
Providing wood work in frames of door, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fasteners shall be paid fro separately).
Providing and fixing M.S. grills of required pattern I frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings / wooden frames with rawl plugs screws etc.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I0 decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.9.1.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.9.1.1 35 mm thick sqm 4458.40
15 mm cement plaster on rough side of single or half brick wall of mix : 13.5.1 1:4 ( 1 cemment : 4 coarse sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : 13.60.1 Two or more coats on new work
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4:- Hot rolled deformed bar
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 :- 1;2;4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5:- 1:3:6 ( 1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources )
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4:- Hot rolled deformed bar
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.2 :- 1:4 ( 1 cemment : 4 fine sand)
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) for sluice valve, with C.L. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design bricks of class designation 7.5
Providing and fixing water closet squatting pan ( Indian type W.C pan) with 100 mm sand cast Iron P or s trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 17.1.1 white Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests `
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherver required : 17.4.1 One urinal basin with 5 litre white P.V.C automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.7.1 white Vitreous China wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing whitte vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S as per IS - 1729
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.38.1 100 mm dia 17.38.1.1 sand cast iron S&S as per IS - 1729
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.43.1 100x100x100 mm 17.43.1.1 sand cast iron S&S as per IS -1729
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.9.3 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.9.1 :- 15 mm Dia
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 : 18.53.1 15mm nominal bore
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m 2.8.1 Al kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5:- 1:3:6 ( 1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4:- Hot rolled deformed bar
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footing, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girdens, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, piers, Abutments, Posts and Struts
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 ( 1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls ( any thickness), including attached pilasters, buttresses, plinth and string cources, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth levele up to floor five level, excluding cost of centering, shuttering, fisnishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Half Brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand)
Steel work in built up tubular (round, sqaure or rectangular hollow tubes etc. ) trusses etc, including cutting, hoisting, fixing in positrion and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 10.16.1 Hot finished welded type tubes
Providing & Fxing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimension as per IS code 2767 with Code Description Unit Rate No.271SUB HEAD : 12.0 ROOFING characteristics of good formability and corrosion nresistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex Cap headed self fdrilling/tapping Stainless steel screws M6, 50mm long with 3mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. 9Cost of truss/frame work shall be paid separately). 12.65.1 0.56 mm, Aluminium color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overrall profile width 1092 mm, cover width 1000mm.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for seperately) 9.1.2 Sal wood
Providing and fixing M.S. grills of required pattern I frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings / wooden frames with rawl plugs screws etc.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I0 decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necesssary screws
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.9.1.1 35 mm thick sqm 4458.40
15 mm cement plaster on rough side of sigle or half brick wall of mix : 13.5.1 1:4 9 1 cement : 4 coarse sand
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : 13.60.1 Two or more coats on new work
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4:- Hot rolled deformed bar
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 :- 1;2;4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a laed of 50 m. 2.8.1 All kinds of soil.
Dry brick pitching half brick thick I drains including supply of bricks an preparing the surface complete : 16.12.1 with common burnt clay F.P.S (non modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5:- 1:3:6 ( 1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4:- Hot rolled deformed bar
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footing, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girdens, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, piers, Abutments, Posts and Struts
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.1.2:- 1:1.5:3 ( 1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string cources, fillets, columns, pillars , piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone-III) derived from natural sorces : 3 graded stone aggregate 20 mm nominal size derive from natural sorces)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Half Brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand)
Steel work in built up tubular (round, sqaure or rectangular hollow tubes etc. ) trusses etc, including cutting, hoisting, fixing in positrion and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 10.16.1 Hot finished welded type tubes
Providing & Fxing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimension as per IS code 2767 with Code Description Unit Rate No.271SUB HEAD : 12.0 ROOFING characteristics of good formability and corrosion nresistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex Cap headed self fdrilling/tapping Stainless steel screws M6, 50mm long with 3mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. 9Cost of truss/frame work shall be paid separately). 12.65.1 0.56 mm, Aluminium color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overrall profile width 1092 mm, cover width 1000mm.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for seperately) 9.1.2 sal wood
Providing and fixing M.S. grills of required pattern I frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings / wooden frames with rawl plugs screws etc.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I0 decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.9.1.1 35 mm thick sqm 4458.40
15 mm cement plaster on rough side of single or half brick wall of mix : 13.5.1 1:4 ( 1 cemment : 4 coarse sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surfaces : 13.43.1 Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : 13.60.1 Two or more coats on new work
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4:- Hot rolled deformed bar
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing nd reinforcement - All work up to plinth level : 5.1.3 : - 1:24 ( 1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
BALURAM DIHINGIA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .