Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹31.3 L+₹2.3 L (7.97%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹31.6 L+₹2.7 L (9.20%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹32.4 L+₹3.4 L (11.7%)Rejected-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹38.7 L+₹9.7 L (33.4%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC REJECTED |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Aug 2022, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR C/O 56 APO GARHI
GE S U 24 2022 23 DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIFICATION AT CERTAIN LOCATIONS AND MAINTENANCE OF CERTAIN PARTS OF GEYSERS AND ALLIED WORK AT CERTAIN LOCATIONS UNDER AGE EM OF GE SOUTH UDHAMPUR
2022_MES_539345_2
GE/S(U)-24/2022-23
Open Tender
Civil Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT documents
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹96,000
1 Oct 2022
5 Aug 2022
20 Aug 2022
5 Aug 2022
19 Aug 2022
6 Aug 2022
5 Aug 2022 - 6 Aug 2022
Amount
Repairing of unserviceable light point, Fan point, socket point 5A/15A, switches, sockets or regulator, light fixtures any type, any type MCBs, DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires upto 2.5 sqmm single core (not more than 50 cm), adhesive tape and other connected accessories like screws & washers etc. Work shall also include to check & removal of breakages in service connection /sub main of houses as and when directed. The scope of work shall also include cutting of existing Bakelite sheet to accommodate new wiring accessories like switches, sockets, fan regulators etc complete all as specified and as directed. (Note: Any major items required to be replaced for this job will be measured and paid under Relevant items.
(a) Contractors representative/engineer will report to JE E/M/Engr-in-charge daily at forenoon and afternoon to collect routine/urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(b) The penalty shall be applicable to the contractor if the delay is noticed by the EIC more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge/ JE E/M shall handover the slip containing specification of work to the contractor. The contractor shall attend the job immediately and report to Engr-in-Charge within 12hrs. The contractor will keep his tradesmen in stand by for attending any routine/urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 20 per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW –2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regard shall be final and binding.
(c) One Complaints slip to be treated as One Complaint irrespective of No. of Repairs mentioned in the same.
(d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours ( 0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs ) Other than the Regular complaints during working Hrs ( 0900 Hrs to 1700 Hrs )
(e) Procurement of Security gate passes of the Electrician will be sole responsibility of the Contractor
(f) If the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the govt.
Switch piano flush type SP, one way 5 Amps including taking down old one complete all as specified and as directed.
Switch piano flush type SP, one way 15 Amps including taking down old one complete all as specified and as directed.
Switch -Socket combination 2-in-1, 5 Amps, flush type including taking down old one complete all as specified and as directed.
Switch - socket combination 5A/16 Amps, 5 in 1 including taking down old one complete all as specified and as directed.
Socket outlet 2-in-1, 5 pin, 5 Amps including taking down old one complete all as specified and as directed.
Socket outlet, 2-in-1, 5 pin, 5 and 15 Amps flush type combined including taking down old one complete all as specified and as directed.
Two way switch 5 Amps, 230 volts including taking down old one complete all as specified and as directed.
Ceiling rose, surface bakelite 65mm x 50mm, 3 terminals fixed on PVC Round Block including complete all as specified and as directed.
Angle lamp holder PVC/Polycarbonate with back plate suitable for fittings including taking down old one complete all as specified and as directed.
Bell push 230 volts, AC including taking down old one complete all as specified and as directed.
Call bell ding-dong 230 volts including taking down old one complete all as specified and as directed.
Switch modular type, 1 module, 6 Amps one way including taking down old one complete all as specified and as directed.
Switch modular type, 1 module, 16 Amps one way including taking down old one complete all as specified and as directed.
Socket outlet modular type, 2 module, 3 pin, 6 Amps combined including taking down old one complete all as specified and as directed.
Socket outlet, modular type, 2 module, 2-in-1, 6/16 Amps combined including taking down old one complete all as specified and as directed.
Two way switch modular type, 1 module, 6 Amps including taking down old one complete all as specified and as directed.
Bell push with indicator modular type, 1 module, 6A, including taking down old one complete all as specified and as directed.
Fan regulator modular type, 2 module, step type,120 watts complete all as specified and as directed.
Fan electronic dimmers/ Socket type 450W, 250V flush type on the existing laminated sheet complete all as specified and as directed.
Switch - socket combination 5 Amps,5 pin multi purpose with PVC Box, 4 holes complete all as specified and as directed.
Switch - socket combination 15 Amps, 6 pin multi purpose with PVC Box, 4 Holes complete all as specified and as directed.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way double door complete with appropriate size bus bar,neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note-MCBs will be measured separately.)
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note-MCBs will be measured separately.)
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note-MCBs will be measured separately.)
Sheet metal enclousers, TPN Distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note-MCBs will be measured separately.)
VTPN MCCB DB Double Door (Including 100 Amp MCCB) 16 KA (as Incommer) 4 way double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
MCB Single Pole, 230 Volt, C-Series, Raiting 6 to 32 Amps complete all as specified and as directed.
MCB Single Pole and Neutral, 230 Volt, C-Series, Rating 40A as incoming in MCB SPN DB complete all as specified and as directed.
MCB Single Pole and Neutral , 230 Volt, C-Series,Rating 63A as incoming in MCB SPN DB complete all as specified and as directed.
MCB Thriple Pole and Neutral, 230 Volt, rating 63A as incoming in MCB TPN DB complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick as earth electrode burried directly in ground earth plate not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5 m below ground level connected to and including galvnised steel earth lead wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board / panel , watering pipe 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of characoal dust and salt all around the earth plate , earth work in any type of soil, remaning surplus excavated material all as required at site and specified in electrical plate EP no 3 of relevant SSR complete all as specified and as directed.
LED tube light fitting Garnet 20W Batten LED, Housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED tube light fitting Garnet 10W Batten LED, Housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED tube light fitting Garnet 5W Batten LED, Housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED 10 watt Bulk Head Light energy saving with IP65 with opal diffuser , pressure die cast aluminium housing and making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED Panel light 2' x 2' capacity 36 Watt extruded aluminium housing with milky diffuser recess mounting ultra modern desinged architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstron/Grid ceiling including driver 36 Watt capacity complete making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one all as per the directions complete all as specified and as directed.
LED Panel light 2' x 2' capacity 36 Watt, extruded aluminium housing with milky diffuser surface mounting ultra modern desinged architectural LED luminaire which provides soft-light and glare free symmetrical illumination including driver 36 Watt Capacity complete making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Driver for 2 'x 2' LED Panel with all necessary fixing arrangement including taking down old one complete all as specified and as directed.
Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and as directed.
Point wiring for one light /fan/ Bell point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade in and including not less than 2.00 mm thick and 20 mm dia Non metallic Rigid PVC surface/Concealed Conduit (ISI marked) and 1.5 mm thick mild steel terminal boxes concealed on walls, painting the same inside and out side with one coat of black bitumen paint with 3mm thick hylam brand bakelite sheet cover for fixing of piano switches/sockets/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable (green color) as earth lead, & connected to common earth and earth dolly, making good the disturbed surface to match with the existing specification complete all as specified and as directed.
All as per Item No.41 above, but for one light point controlled by two nos two way switches on independent Board with 1.5 sqmm size of copper cable complete all as specified and as directed.
All as per Item No. 41 above, but for 3 pin 5 Amp Socket outlets point controlled by one switch 5A piano type on Same board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No. 41 above, but for 3 pin 5 Amp Socket outlets point controlled by one switch 5A piano Type on Independent board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No. 41 above, but for 3 pin 15A socket outlet point controlled by one switch 15A on the independent Board with 2.5 Sqmm size of copper cable complete all as specified and as directed.
All as per ser item No 41 above, but for 3 pin 20 A socket outlet point controlled by one modular switch 20A on the independent board with 4 sqmm size of copper cable as main and 2.5 sqmm copper cable as earth lead complete all as specified and as directed.
Point wiring for one light /fan/ Bell point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade in and including not less than 2.00 mm thick and 20 mm dia Non metallic Rigid PVC surface/Concealed Conduit ( ISI marked ) and 1.25 mm thick mild steel terminal boxes (Modular Type) concealed in wallsfor fixing of modular switches/sockets/ regulator etc along with PVC insulated and unsheathed FRLS 1.5sqmm multi stranded copper conductor cable (green color) as earth lead, & connected to common earth and earthdolly, making good the disturbed surface to match with the existing specification complete all as specified and as directed.
All as per Item No. 47 above, but for one light point control by two nos two way modular switches on independent Board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.47 above, but for 3 pin 5 Amp Socket outlets point controlled by one modular switch 6A piano type on Same board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.47 above, but for 3 pin 5 Amp Socket outlets point controlled by one modular switch 6A piano Type on Independent board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.47 above, but for 3 pin 15A socket outlet point controlled by one modular switch 16A on the independent Board with 2.5 Sqmm size of copper cable complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm drawing through existing surface / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 6 Sqmm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm drawing through existing surfacce / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 2.5 Sqmm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with four single core PVC insulated with copper conductor cable stranded of size 6 Sqmm drawing through existing surface / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 4 Sq mm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed.
Fan Capacitor 2.5/3.15 mfd AC, 415 volt complete all as specified and as directed.
Supply and Laying or Fixing or passing through pipe 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 2 core 6 sqmm nomial cross section in service connection including taking down of old u/s service connection from pole to DB complete all as specified and as directed.
Supply and fixing GI tubing light grade 25 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
LED street light fitting 25W Garnet with single piece deep drawn aluminium housing with side reflectors and acrylic cover including fixing arregement in existing bracket complete all as specified and as directed.
Modular plate 1 module including taking down old u/s one complete all as specified and as directed.
Modular plate 2 module including taking down old u/s one complete all as specified and as directed.
Modular plate 3 module including taking down old u/s one complete all as specified and as directed.
Modular plate 4 module including taking down old u/s one complete all as specified and as directed.
Modular plate 6 module including taking down old u/s one complete all as specified and as directed.
Modular plate 8 module including taking down old u/s one complete all as specified and as directed.
1.5 Sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and as directed.
2.5 Sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and as directed.
4.0 Sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and as directed.
2.5 Sqmm PVC insulated FRLS unsheathed copper conductor round three core flexible copper cable 1100V grade complete all as specified and as directed.
PVC casing caping of size 20/25mm including all accessories i.e. Nail, tee, elbow etc complete all as specified and as directed.
PVC conduit of size 20/25mm including all accessories ie Nail, tee, elbow etc complete all as specified and as directed.
PVC flexible cable twisted two core wire of size 40/0.0076 complete all as specified and as directed.
LED Lamp 0.5 watt for Engagement light Red/Green base cap B22 with all necessary fixing arrangement including taking down old one complete all as specified and as directed.
LED 15 Watt Surface Mounting fitting round/squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED 15Watt Recess Mounting fitting Round/Square type, Housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED City 3 decorative wall light fixture made up of polycarbonate and including LED 15W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Venza decorative wall mounting light fitting, SS finish fixture with opal glass diffuser including 12W retrofit LED bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Decorative wall light (SANA) made up of high grade engineering plastic material including retrofit LED Bulb 10 watt and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Decorative wall light (STYLO) fitting, Champagne gold finish fixture with plastic body including 12Watt retrofit LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Decorative wall light (APPLE) fiiting, fixture made up of polycarbonate, including 12 Watt retrofit LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
MCB Three Pole and neutral capacity 100 Amp as incoming in MCB TPN DB complete all as specified and as directed.
Fan regulator stepped type electronic fan regulator flush type on the existing laminated sheet complete all as specified and as directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed.
PVC box two holes best quality (ISI marked) for use MCB SPN complete all as specified and as directed.
LED Bulb capacity 10 Watt Warn white model No B-22/E27 complete all as specified and as directed.
LED 06 Watt Recess mounting fitting round/squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED 12 Watt Recess mounting fitting round/squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Taking out geyser carefully from its location of any make & capacity 25/35/50Ltr and dismantling the same for replacement of parts described under items here-in-below and installed with complete repair and re-assembling and installation of complete set to work complete all as specified and directed. Note :- Labour for taking down and re-fixing all type of spare parts included in this items & all type of Defective parts/glass wool will be measured and paid saparately under respective items of BOQ as supply only complete all as specified and as directed.
Supply of PVC connection with two Nos of adapter and washer of size 300 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply of PVC connection with two Nos of adapter and washer of size 450 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply of SS connection heavy duty (steel type) connecting with two Nos of adapter and washer of size 300 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply of 6/9 holes Head assy assy/Apparatus plate heavy duty 18 SWG with rubber gasket of suitable size for 25/35/50 Ltr cap geyser of any make complete all as specified and as directed.
Supply of Heating element any type (i.e Cup/ threaded/triangular) 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply of Heating element complete set for Havells geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply of Heating element complete set for Bajaj Calanta geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply of Heating element complete set for Racold geyser of 2.0 KW, vertical plate type/horizontal triangular type 220/230 volts (ISI marked) complete all as specified and as directed.
Supply of Instant Water heating coil for Geyser, Coil Type, (ISI Marked) 3KW, suitable for 1 ltr to 5 ltr instant geysers complete all as specified and as directed.
Supply of thermostat ranging 25 degree to 75 degree adjustable type, long, Operative on 250 Volts complete all as specified and as directed.
Supply of Safety Plug "Brass" (ISI marked) complete all as specified and as directed.
Supply of Rubber gasket for apparatus plate suitable for any 25/35/50 ltr cap geyser complete all as specified and as directed.
Supply of Element holding clamp suitable for geyser of cap 25/35/50 ltr complete all as specified and as directed.
Supply of stainless steel inner tank Capacity 25 Ltr heavy duty (Approx height 304 mm) with SS 304 Grade complete all as specified and as directed.
Suppply of stainless steel inner tank capacity 35 ltr heavy duty (Approx height 396 mm) with SS 304 Grade complete all as specified and as directed.
Supply of stainless steel inner tank capacity 50 Ltr (Approx height 507 mm) with SS 304 Grade complete all as specified and as directed.
Supply of indicator lamp, round/square, green /red as per requirement complete all as specified and as directed.
Supply of PVC insulated Top plug 3 pin 15 Amp (ISI Marked) complete all as specified and as directed.
Supply of Steel sheet outer body of Geyser suitable for 25/35/50 ltrs capacity complete all as specified and as directed.
Supply of glass wool for Geyser of any Make for capacity 25/35/50 ltr complete all as specified and as directed.
Taking up or down steel water tubing 15 mm/20 mm dia with fitting and for cleaning including refixing/remove from the site complete all as specified and as directed.
Steel water tubing 15 mm dia (medium grade) galvanised with all fittings including short lengths, fixed to wall and ceiling or laid in floor complete with all fitting (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed.
Pressure release valve, dead weight type, (ISI marked) complete all as specified and as directed.
Non return valve 15 mm dia pipe brass made (ISI marked) complete all as specified and as directed.
15 mm brass angle valve (ISI marked) complete all as specified and as directed.
15 mm bib tap (ISI marked) complete all as specified and as directed.
GI Fastner bolts including nuts washer off sizes 4/6 Inch suitable for fixing of any capacitty geysers as required at site to the entire satisfaction of Engineer-in-Charge.
PVC Copper cable flexible 3 core round heavy duty size 40/0.0076 suitable for geyser any capacity to the entire satisfaction of Engineer-in-Charge.
Taking down Geysers (cap 25/35/50 ltr), cleaning its dust particles, one coat of synthetic enamel white spray painting ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to socket etc complete after completing the wiring complete all as specified and as directed.
Supply of bolts, nut and washers for Geysers complete all as specified and as directed.
Sheet metal enclosures for DBs when MCBs to be used Single door DB SPN 2 way 240 volts with 200 amps rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 2 way with Single door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and directed.
De-scaling of geysers tank 25/35/50 ltrs capacity complete all as specified and as directed.
Solar water heating element for any type solar heater of any capacity 3 Kw as required on ground complete all as specified and as directed.
Repairing the geyser in situ at its location including replacement of spare parts like heating element, thermostat, indicator, fusible safety vent plug, NRV, GI nipple, PVC connection, stop valve, plug top etc. of any make & capacity 25/35/50 Ltrs geyser and testing complete all as specified and as directed. Note :- Spare parts like heating element, thermostat, indicator, fusible safety plug, NRV, GI nipple, PVC connection, stop valve, plug top, 15 Amp S/s combined shall be measured and paid saperately under respective items of BOQ as supply only.
Note for Srl Item No 122 above :- (a) Contractors representative/engineer will report to JE E/M/Engr-in-Charge Daily at forenoon and afternoon to collect routine/urgent works related to geyser complaints till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, screws, nuts, bolts, washers etc. required to accomplish the job. The contractor will also ensure as availability of every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24 hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty.
(b) The penalty shall be applicable to the contractor if the delay is noticed by Engr-in-Charge more than 12 hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge/JE E/M shall handover the slip containing specifications of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the job immediately and shall report to Engr-in-Charge within 12 hrs. The contractor will keep his tradesman in stand by for attending any routine/Urgent works from the executive If the nature of job is such that the workcannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the EE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 20 per job shall be deducted from the dues of the contractor. Please note that this penalty ois exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the deptt. the decision of the Accepting Officer is this regard shall be final and binding.
(c) One loged Complaints slip, is to be treated as One Complaint in irrespective of No. of Repairs mentioned in the same. (d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours (0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs) Other than the Regular complaints during working Hrs (0900 Hrs to 1700 Hrs) (e) Procurement of Security gate passes of the Electrician, will be sole responsibility of the Contractor as per CA provision.
NOTE - (i) Replacement of unserviceable parts shall be measured and paid for separately under respective items as Supply Only. (ii) On testing after completion of repair, if the proper functioning without leak, not obtained at Engr-in-Charge satisfoactory level, the reapiring will be re-done by the contractor at his own costs and the cost for the same shall be deemed to be included in the quoted rates. (iii) The contractor shall maintain/open a Workshop and keep his electrician ready during working Hrs (0900 Hrs to 1700 Hrs) for geyser repair, inside MES store Yard so that all the repairing/Descaling/changing parts of geysers will be done in proper manner, MES authorities will not be issued any Geysers/winter appliances, any type, for repaire puropse to the contractor for his outside workshop.
ARNABH ASSOCIATES
DEV RAJ MAGOTRA
FANGALIA TRADERS
SINGH CONST CO
Hi Tech Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .