Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
14 Aug 2023, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
CERTAIN MAINT OF INTERNAL ELECTRIFICATION SYSTEM CEILING FANS EXHAUST FANS VENTILATION FANS OF OTM MD ACCN AT DHANGU AND BHADORIYA COMPLEX AREA UNDER GE SOUTH PATHANKOT
2023_MES_609178_1
GES/PKT/T-14/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹99,800
Yes
14 Nov 2023
15 Jul 2023
16 Aug 2023
15 Jul 2023
14 Aug 2023
31 Jul 2023
Amount
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1400mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same(Note - (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Replacement of old unserviceable gun metal bush of ceiling fan complete all as spd and directed.
Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd ISI marked complete all as spd.
All as per Srl item no.4 above but 3.15mfd complete all as spd.
Replacement of old unserviceable ball bearing suitable for 1200/1400 mm sweep complete. (bearing with 8 balls shall only be used) complete all as spd.
Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/ 1400mm sweep complete all as specified and directed.
Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as spd.
Repalcement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as spd.
S & F Canopy for ceiling fan as per existing sample complete all as specified and as directed.
S & F PVC Two way connector for ceiling fan complete all as specified and directed.
Replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/site requirement/ Makeof fan complete all as spd.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/ oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid seperately).
S&F cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed.
Dismantling and Re-winding of exhaust fan/industrial fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as spd and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used).(ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
All as per Srl item no. 15 above but 350mm-450mm sweep complete all as spd and directed.
Dismantling of wall/pedestal fan of any sweep, repair the same by cleaning, overhauling, necessary lathe work (grinding & polishing) etc and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning and reassembling the wall/pedestal fan after replacement of unserviceable minor parts such as frame nut, knob, regulator switch clamp of cendenser etc as required for smooth functioning of the fan and Replacement of unserviceable major parts like capacitor, bearing, bush etc and testing complete on completion and re-fixing the fan in existing position including provn of twin twisted flexible copper stranded conductor wire of size 23/0.0076 Sqmm of required length complete as directed by the Engineer-in-Charge (Note : (a) Replacement of unserviceable major parts like capacitor, bearing, bush etc shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Unit quoted rate shall deemed to be inclusive of transportation of fan to workshop form MES store yard)
S & F louver, suitable for exhaust fan of any make and size upto 300-350 mm, fixed in repair complete all as specified and as directed.
All as per itemNo. 18 above but of size 400 mm-450 mm
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to exhaust fan/wall mounting fan/ Padestial Fan of any sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
S&F in repair ceiling fans 1200 mm Sweep Ceiling Fan, Energy Saving, BLDC Motor without romote complete with regulator, canopy, blades, down rod, split pin etc complete of approx wattage 30 to 32 Watt rated suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard.
S&F in repair Ventilation fan AC sinlge phase 230/240 volts of size 200 to 250 mm sweep PVC body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 450 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F in repair wall mounted fan 400 mm Sweep Energy Saving, copper wounded Motor, three speed control complete suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard.
Disconnecting the inlet/outlet water connections and electric connections of Storage storage type electric water heater of capacity 25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceablity/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacemeny shall be measured and paid under relevant Schedule items of Sch here-in-after.
Supply only internal SS tank of storage type electric water heater of 25 ltr capacity complete with syphon –assembly, 1.5 KW/2.0 KW element , rubber gasket , thermostat switch , all as specified and directed for carrying out repairs under relevant item No.1 . Note :- The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed.)
Supply only syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directed for carrying out repairs under relevant item No.27.
Supply only thermostat switch ISI marked for storage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius ) for carrying out repairs under relevant item No.27
Supply only cup/triangular type storage type electric water heater element AC 230 volt, of rating 1500/2000 watt for carrying out repairs under relevant item No.27
Supply only outer body suitable for 25 ltr storage type electric water heater made out of MS sheet factory made complete with fixing bracket matching with existing complete all as specified and directed for carrying out repairs under relevant item No.27
Supply only glass wool of 25 ltrs capacity storage type electric water heater complete all as specified and directed for carrying out repairs under relevant item No.27
Supply only indicator lamp square/round type suitable for storage type electric water heater 25 ltr all as per sample AC 230 Volt for carrying out repairs under relevant item No.27
Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 70/.0076mm.
S&F sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
De-scaling of storage type electric water heater of capacity 25 ltr after taking down the storage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of storage type electric water heater complete all as directed by Engineer-in –Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked all as specified and as directed.
Replacement of spring loaded air release valve ISI marked suitable for 25 ltrs capacity storage type electric water heaters.
Replacement of safety valve / dead wt. valve ISI marked suitable for 25 Ltrs capacity storage type electric water heaters.
Supply and replace pillar taps, cast copper alloy with capastan heads, chromium plated, screwed down high pressure with lettered ‘Hot or Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed fancy type of size 15 mm .
S&F gun metal glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm.
S&F anchor bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
Preparing the old surface by rubbing/scratching the old paint and providing the one coats of synthetic enameled paint through spray paining of 25 ltr storage type electric water heater.
Supply and replace brass non return valve suitable for 25 ltr storage type electric water heater of size 15 mm.
Supply and replace bottom cover plate of storage type electric water heater of capacity 25 ltr complete with MS screw all as per sample.
Dismantling of Insulated hot water storage tank of capacity up to 500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
Service and descaling of Solar Evacuated tube Collector/ Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity Upup 500 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
Replacement of heating element 2/3 KW suitable for stand by back up supply to solar water heater.
M & L for replacement of unserviceable stop valves and S & F stop valves , cast copper allow, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed Size 15mm ISI mark.
Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning of storage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed.(Note : Rate quoted deemds to be inclusive of anchor bolt, and pvc connetion)
Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning of storage type electric water heater of 50 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed. (Note : Rate quoted deemds to be inclusive of anchor bolt, and pvc connetion)
Supply only wiring for desert cooler including all accessories all complete diected for carrying out repairs under relevant item.
Supply only blower motor of single way shaft 240 Volts 50 c/s of suitable capacity for desert cooler of capacity 3000 CFM to 5000 CFM single way shaft 240 Volts 50 c/s complete all as specified and directed for carrying out repairs under relevant item.
Supply only water circulation pump suitable for desert cooler of capacity 3000 CFM to 5000 CFM 240 volts 50 c/s single phase complete all as specified and directed for carrying out repairs under relevant item.
Supply only Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three) complete all as specified and directed for carrying out repairs under relevant item.
Removing the old paint from the body of desert cooler making the body dust proof and preparing the surface and painting the desert cooler with one coats of synthetic enamel paint of superior quality over a coat of Red Oxide primer all as specified.
Removing the old rusted base tub of desert cooler of 3000 to 5000 cfm capacity and fabrication of base tray and top cover made of PGI sheet of minimum 0.8 mm thick sheet and fixing in position using necessary nuts, bolts and washers all as specified and directed.
S&F in replacement of existing UNSV galvanized iron top cover of minimum 0.8 mm thick sheet per and providing new one of existing size, gauge and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
S&F in replacement of existing UNSV galvanized iron side pillar of minimum 0.8 mm thick sheet as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge
S&F in replacement of existing UNSV galvanized iron side shutter of minimum 0.8 mm thick sheet as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Fan blade hub assly only for Blower motor of desert cooler made of alloy/Forged steel suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
M&L in replacement of Leg set complete for fixing blower motor for desert cooler complete with all necessary fixing/Fastening arrangements(As per sample) suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
M&L in replacement of water distributor and PVC pipe connection for water connection of desert cooler 3 piece (length not less than 35 cm each piece) (As per sample) suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
M&L in replacement of Capacitor of capacity 4mfd suitable for desert cooler complete all as specified and directed
Dismantling old defective desert cooler and depositing to MES store yard. Supply, install, test and commissioning of desert cooler electric driven, single phase of approx minimum size 575x575x800 mm made out of 0.8 mm thick GI sheet for body, with water tank of capacity 50 Ltr made out of 1 mm thick and with front grills and side direction grills, suitable for minimum air Delivery- 4000 Cum/hr,approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6Amps piano switch. Water immersed pump of suitable capacity 1300 RPM rated suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch with fan motor of minimum capacity 105 watt, 1400RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm .The pad of 3 sides shall be of honeycomb type, including stand of minimum height 900 mm made out 25mmx25mmx3mm MS angle iron , duly coated with weather proof paint of black colour
S&F plug top polycarbonate 3 pin, 5Amp all as specified and directed by Engr-in-Charge
S&F PVC insulated and PVC sheathed 3 Core copper conductor flexible round cable of 02 Sq mm all as specified and directed.
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed.
M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ ceiling roses etc) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
All as per item no. 73 above but in existing conduit and pressed steel terminal boxes
All as per srl item no. 73 above but for one light point controlled by 2 nos two way switches.
All as per items no. 75 above but in existing conduit and pressed steel terminal boxes
All as per srl item no. 73 above but for one 3 pin 5A socket outlet independent board.
All as per items no. 77 above but in existing conduit and pressed steel terminal boxes
All as per srl item no. 73 above but for one 5A socket outlet on the same board
All as per item no. 79 above but in existing conduit and pressed steel terminal boxes
All as per srl item no. 73 above but for one 5A socket outlet below the board.
All as per items 81 above but in existing conduit and pressed steel terminal boxes
All as per srl item No 73 above but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor.
All as per item no. 83 above but in existing conduit and pressed steel terminal boxes
M & L for replacement of existing un-serviceable switch with switch piano polycarbonate body flush button single pole two way 5 amps, 230 volts.
M & L for replacement of existing un-serviceable switch with switch piano polycarbonate body flush button single pole one way 15 amps, 230 volts.
M & L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 3 pin, 5 Amp and 15 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 5 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
M & L for replacement of existing old u/s bell push with bell push polycarbonate body type 5/6 Amp, 230 volts.
M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified.
M and L for replacement of existing old u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed
M and L for replacement of fan regulator suitable for BLDC fan and connecting electrically all as required or directed
M & L for replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
S & F for replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting all as directed.
M&L for Modular point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Modular inner and outer frame plate shall be included in quoted rates (b) Proper colour coding is to be followed as per IS Specification. (c) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(d) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(e) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
All as per srl item No. 97 above but for one 3 pin module socket out let 5/6 Amps on same board.
All as per srl item No. 97 above but for one module socket out let 5/6 Amps on Independent board.
All as per srl item No. 97 above but for one module socket out let 5/6 Amps on below the board.
All as per srl item No. 97 above but for 15/16 Amps socket out let independent with 4 sqmm copper conductor
M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable switch piano with Modular switch 2 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 16A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable socket outlet with Socket, 6A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable socket outlet with Socket, 16A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing un-serviceable fan regulator with modular fan regulator step type 120 watts 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
M & L for replacement of existing old u/s tube light fitting with energy saving decorative batten type fitting with LED tube rod 18/20 watt energy efficient tube light fittings LED complete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.
Supply and fixing LED Bulk head light fitting 1 X 13.5watts cool Daylight (CDL) round type premium quality diffuser for even distribution of light complete , connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
M & L for replacement of existing old u/s mirror light fittings with sleek energy efficient decorative LED mirror light 10 watts, 2 feet with diffuser complete with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.
S&F LED Lamp 230 volts,50 Hz,inverter LED 10 watt ,lumen 900 lm, Charging time 8 to 10 Hours, backup time 04 Hrs, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specififed and direccted.
M & L for replacement LED lamp 7 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
M & L for replacement LED lamp 15 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
M & L for replacement LED lamp 12 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
S&F in replacement sheet metal enclosure 4 way , with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement sheet metal enclosure 8 way, with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement sheet metal enclosure 12 way, with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement of existing old u/s MCB SPN with MCB SPN C curve ,240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
S&F in replacement existing unsv distribution board iron clad, with double door 4 way with IP-54,1K-09 protection, cemet spill prptector suitable for MCCB as incommer AC 415 Volts three pole with thermal release adjustable type (80% to 100 % ) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge.
S&F in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge.
S&F in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors, geyser, fans etc and other similar electrical items/fittings etc. including providioning of small pieces of electrical wire if required of size 1.5 sqmm to 2.5 sqmm single core and length not exceding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge. (Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch 'A' . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Entire Bhadoriya complex (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi) Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
S&F socket outlet Polycarbonate body 2 in 1, 3 pin 15 Amp flush type all as specified and directed.
S&F socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
S&F in repair of Hylum sheet 5x5 to 10 x 12 inches for fixing of switches, sockets etc including cutting for fixing on existing or new sunken box with brass screw complete all as specified and directed by Engr-in-charge
S&F in repair of pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth of size 4x4 to 10 x 12 inches for fixing bakelite sheet of suitable size complete all as specified and directed by Engr-in-charge
S&F in repair ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 2.5 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 4.0 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 6.0 sqmm , cut to size all as required at site.
S&F in replacement of old u/s service cable size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
All as per srl item 137 above but for service cable of size 10 sqmm,complete all as spd and directed.
All as per srl item 137 above but for service cable of size 16 sqmm,complete all as spd and directed.
S&F electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
JANDIAL ENTERPRISES
M/s. Aggarwal Engineers
M/S SATPAL & BROTHERS
Khurl Construction Co.
Rajinder Kumar Manhas
KULBHUSHAN AGGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .