Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.8 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹69.8 L Quoted ₹70.7 L | L1 | Accepted-AOC lowest tenderer |
| 2 | L2₹71.1 L+₹37,102.65 (0.52%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹71.1 L+₹37,102.65 (0.52%) | L2 | Rejected-Finance Being not lowest bidder |
| 3 | L3₹73.3 L+₹2.5 L (3.57%)Rejected-Finance A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | ₹73.3 L+₹2.5 L (3.57%) | L3 | Rejected-Finance Being not lowest bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not meeting eligibility criteria. Please refer technical evaluation summary uploaded herewith for details. |
| Sl No | Description | Qty | Unit | mayur enterprises L2 | Commercial Traders L1 | Deepak Electricals L3 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location including disconnection of existing electric incomming and outgoing cable and dismantling of PCC platform and make good with existing surface complete all as directed by the Engr-in-Charge. | 2 | Each Job | 2,000 ₹4,000 | 1,500 ₹3,000 Lowest | 5,000 ₹10,000 |
| 2.00 | Disconnecting / taking down carefully existing unserviceable DG Set of capacity 200& 250 KVA with complete connected items including all control switches, fitting and fixtures from existing location and deposited to MES Salvage yard complete all as directed by the Engr-in-Charge. | 2 | Each Job | 5,000 ₹10,000 Lowest | 5,000 ₹10,000 Lowest | 8,000 ₹16,000 |
| 3.00 | Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors of not less than 200 KVA /160 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lag , 243.3 HP minimum Required Power for Rated KVA (hp) along with AMF system with as per OEM recommendation Acoustic Enclosure exhaust silencer Hospital Grade in line, as per the noise emmission standards (CPCB-IV) laid down by MoEF / CPCB Norms, | 1 | Each | 29,00,000 ₹29,00,000 | 26,50,000 ₹26,50,000 Lowest | 28,50,000 ₹28,50,000 |
| 3.01(A) Engine comprising of the following: The 200 kVA diesel engine genset (BS-5514) is designed for prime duty operation with an output of 200 kVA / 160 kWe. It is powered It is powered by engine power of 178 kW (approximately 243.3 HP), 6-cylinder, inline, turbocharged aftercooled (TCAC) engine with a displacement of 7.31 litres and bore × stroke of 108 × 133 mm. The radiator liquid cooled and operates at a compression ratio of 16.8:1. It runs at a rated speed of 1500 RPM with an overspeed trip at 1650 RPM and is equipped with an electronic/CRS G3 governor, ensuring isochronous frequency regulation for stable performance. The exhaust system is designed to handle a maximum back pressure of 13 kPa with an exhaust gas temperature of around 530°C and includes an after-treatment system comprising DOC, SCR, and ASC. The engine electrical system consists of a 12V, 35A charging alternator and a 2X12V, 150 Ah battery for starting. It operates on High Speed Diesel (HSD) as per IS 1460 standards, with a fuel tank capacity of 320 litres. The fuel consumption is approximately 44.3 LPH at full load and about 33 LPH at 75% load. The lubrication system has a sump capacity of 17.5 litres with an oil change interval of 500 hours. The engine uses 15W40 grade lubricating oil (API CI4+) with oil consumption limited to ≤0.06% of specific fuel consumption. It is equipped with spin-on type oil filters (single unit), ensuring efficient filtration and reliable engine operation. (B) Alternator comprising of the following: The alternator of 200 KVA genset is designed ( IS- 13364) part-II for three-phase operation at a voltage of 415 V and a frequency of 50 Hz. It delivers a rated current of 278.24 amps and is of 4-pole, rotating field type construction. The alternator is equipped with an automatic voltage regulator (AVR) ensuring voltage regulation within ±1%, providing stable and reliable output. The insulation class of the alternator is Class H, suitable for high-temperature operation, with a permissible temperature rise of up to 125°C. It is fitted with a single sealed bearing for durability and requires minimal maintenance. The alternator is coupled to the engine through a flex disc coupling, ensuring smooth transmission of power and reduced vibration. Additionally, it has the capability to handle unbalanced loads up to 25% of the rated current, making it suitable for varying load conditions. | ||||||
| 3.02Control Panel comprising of the following: (C) AMF / Control panel is manufactured with 16/18 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts of makes as per OEM recommendation: microprocessor based generator set monitoring and control system. AMF Functionality is inbuilt and this control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running', Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and short circuit protections. along with motorised change overs /on load power contactors with copper busbars, cables and protective accessories with load / bypass arrangements. Critical/Hospital Grade silencer with Rain Cap suitably optimized to meet stringent noise emission standards laid down by MoEF/ CPCB along with MS supporting structures .along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12") | ||||||
| 3.03(D) Controller should be compatable to the following specifications: (i) AMF Functionality controllers of Makes from the OEM : (ii) Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft-switches. Indications - Generator set, Utility Status Lamp. (iii) Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours (iv) AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), KVA (phase and total) and Frequency. kwh, Total & per phase (kw & KVA), PF, Utility Voltage and Freq. (v) Engine Protection: Low lube oil pressure, High/Low coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level. (vi) AC Alternator Protection: Over/Under Voltage, Over/Under Frequency, Loss of AC sensing. Over speed, Over Current. (vii) Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii)Configurable glow plug control, Cycle Cranking (ix) 24 Volt DC operation, Sleep mode, Modbus interface (RS485 RTU),In Power compatible (PC based service tool), Certifications - meets the requirement of relevant ISO, EN, Mil Std. and CE standards (e) Maintenance due alarm based on Engine Run Time and duedate, Exercisor scheduler (f) Remote HMI, Digital electronic governor with temperature compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring. | ||||||
| 3.04(g) All pipe line connections, valves etc. required for the lube oils, fuel and cooling system (h) Battery & Battery charger of rated capacity as per the alternator/ Engine compatibility. (j) Mounting Arrangement shall be of the following: (i) Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. (ii) Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning. (k) Fuel Tank of capacity 12 hrs running capacity along with Fuel pipe MS C class 25mm ID with bends , flanges , valves, tees and bends. (l) Control / service cables shall be of 4cx 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables ,pvc insulated copper armoured, control panel for auxiliaries with starters for pumps, heaters etc. (m) RCC foundation with necessary earth work ,PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work/ TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia securing with clips / 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6),even and smooth without using extra cement/ Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions. (n) Acoustic Enclosure shall comprise of the following (i)Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions (ii) The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munsel green shade and a structural/ sheet metal base frame painted in black. or any other standard colour as specified by the OEM (iii) High quality noise absorbent and fire-retardant grade acoustic insulation material (P.U. Foam) complying to IS-8183 designed to have optimum serviceability (iv) Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship (v) 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling arrangement inside the enclosure. | ||||||
| 3.05Note :- (i) Rate quoted shall include the necessary T&P , RCC foundation , structural works required to support the accessories of Dg set such as AMF panels, control cables, Radiators / cooling tower, Exhaust mufflers and water circulation system / cooling System (ii) rate quoted includes the cost of All fuel ( high speed diesel) , lubes and coolant required to carry out the no load and full load test of not less than 12 hrs as directed by the accepting officer (iii) Rate quoted includes the cost of B check for the DG set such as replacement of lube oil, oil/ fuel filters /belts, O rings consumables after the test run of the DG set during the warranty period first 250 hrs/ 1 st year which ever is earlier after the date of commissioning. | ||||||
| 4.00 | Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors of not less than 250 KVA /200 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lag , 303.4 HP minimum Required Power for Rated kVA (hp) along with AMF system with Acoustic Enclosure exhaust silencer Hospital Grade in line, as per the noise emmission standards (CPCB-IV) laid down by MoEF / CPCB Norms, | 1 | Each | 30,80,000 ₹30,80,000 | 29,70,000 ₹29,70,000 Lowest | 33,50,000 ₹33,50,000 |
| 4.01(A) Engine comprising of the following: The 250 kVA diesel engine genset (BS-5514) is designed for prime operation with an output of 250 kVA / 200 kWe. It is powered by engine power of 223 kW (approximately 303.4 HP), 6-cylinder, inline type with turbocharged aftercooled (TCAC) aspiration, having a displacement of 7.31 litres and bore × stroke of 108 × 133 mm and radiator liquid cooled. It operates at a compression ratio of 16.8:1 with a rated speed of 1500 RPM and an overspeed trip at 1650 RPM. The engine is equipped with a CRS/G3 governor and provides isochronous frequency regulation, ensuring stable performance. The exhaust system allows a maximum back pressure of 17 kPa with an exhaust gas temperature of about 550°C and is fitted with an after-treatment system comprising DOC, SCR, and ASC. The engine electrical system includes a 12V, 35A charging alternator and a 2x12V, 180 Ah battery for starting. It runs on High Speed Diesel (HSD) as per IS 1460 standards, with a fuel tank capacity of 385 litres. The fuel consumption is approximately 53.5 LPH at full load and 39 LPH at 75% load. The lubrication system has a sump capacity of 25 litres with an oil change interval of 500 hours. It uses 15W40 grade lubricating oil (API CI4+) with oil consumption limited to ≤0.06% of specific fuel consumption. The system is equipped with spin-on type oil filters (2 numbers), ensuring efficient filtration and reliable engine performance. | ||||||
Tender Value
₹74.0 L
EMD Value
₹1.4 L
Closing Date
7 Aug 2026, 6:00 pmClosed
CWE (AF) TUGHLAKABAD
Headquarters CWE AF Tughlakabad, Air Force Station, Tughlakabad, PO Sangam Vihar, New Delhi 110 080
SPL REPAIR/ REPLACEMENT OF BER DG SET AT 13 BRD AND 16 BRD OF TECH AREA UNDER GE (AF) GURGAON NO. 1
2026_MES_776059_1
CWE/TKD/GUR/TOKEN-03 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PALAM UNDER GE AF GURGAON NO 1
As per NIT.
7 documents required · 7 mandatory
₹1,000
GE (AF) GURGAON NO. 1
₹1.4 L
Yes
15 Sept 2026
2 Jul 2026
10 Aug 2026
2 Jul 2026
7 Aug 2026
24 Jul 2026
3 Jul 2026 - 14 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location including disconnection of existing electric incomming and outgoing cable and dismantling of PCC platform and make good with existing surface complete all as directed by the Engr-in-Charge. | 2 | Each Job | - | - |
| 2 | Disconnecting / taking down carefully existing unserviceable DG Set of capacity 200& 250 KVA with complete connected items including all control switches, fitting and fixtures from existing location and deposited to MES Salvage yard complete all as directed by the Engr-in-Charge. | 2 | Each Job | - | - |
| 3 | Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors of not less than 200 KVA /160 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lag , 243.3 HP minimum Required Power for Rated KVA (hp) along with AMF system with as per OEM recommendation Acoustic Enclosure exhaust silencer Hospital Grade in line, as per the noise emmission standards (CPCB-IV) laid down by MoEF / CPCB Norms, | 1 | Each | - | - |
| 3.01 | (A) Engine comprising of the following:
The 200 kVA diesel engine genset (BS-5514) is designed for prime duty operation with an output of 200 kVA / 160 kWe. It is powered It is powered by engine power of 178 kW (approximately 243.3 HP), 6-cylinder, inline, turbocharged aftercooled (TCAC) engine with a displacement of 7.31 litres and bore × stroke of 108 × 133 mm. The radiator liquid cooled and operates at a compression ratio of 16.8:1. It runs at a rated speed of 1500 RPM with an overspeed trip at 1650 RPM and is equipped with an electronic/CRS G3 governor, ensuring isochronous frequency regulation for stable performance.
The exhaust system is designed to handle a maximum back pressure of 13 kPa with an exhaust gas temperature of around 530°C and includes an after-treatment system comprising DOC, SCR, and ASC. The engine electrical system consists of a 12V, 35A charging alternator and a 2X12V, 150 Ah battery for starting. It operates on High Speed Diesel (HSD) as per IS 1460 standards, with a fuel tank capacity of 320 litres. The fuel consumption is approximately 44.3 LPH at full load and about 33 LPH at 75% load.
The lubrication system has a sump capacity of 17.5 litres with an oil change interval of 500 hours. The engine uses 15W40 grade lubricating oil (API CI4+) with oil consumption limited to ≤0.06% of specific fuel consumption. It is equipped with spin-on type oil filters (single unit), ensuring efficient filtration and reliable engine operation.
(B) Alternator comprising of the following:
The alternator of 200 KVA genset is designed ( IS- 13364) part-II for three-phase operation at a voltage of 415 V and a frequency of 50 Hz. It delivers a rated current of 278.24 amps and is of 4-pole, rotating field type construction. The alternator is equipped with an automatic voltage regulator (AVR) ensuring voltage regulation within ±1%, providing stable and reliable output.
The insulation class of the alternator is Class H, suitable for high-temperature operation, with a permissible temperature rise of up to 125°C. It is fitted with a single sealed bearing for durability and requires minimal maintenance. The alternator is coupled to the engine through a flex disc coupling, ensuring smooth transmission of power and reduced vibration. Additionally, it has the capability to handle unbalanced loads up to 25% of the rated current, making it suitable for varying load conditions. | - | - | - | - |
| 3.02 | Control Panel comprising of the following:
(C) AMF / Control panel is manufactured with 16/18 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts of makes as per OEM recommendation: microprocessor based generator set monitoring and control system. AMF Functionality is inbuilt and this control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running', Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and short circuit protections. along with motorised change overs /on load power contactors with copper busbars, cables and protective accessories with load / bypass arrangements.
Critical/Hospital Grade silencer with Rain Cap suitably optimized to meet stringent noise emission standards laid down by MoEF/ CPCB along with MS supporting structures .along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12") | - | - | - | - |
| 3.03 | (D) Controller should be compatable to the following specifications:
(i) AMF Functionality controllers of Makes from the OEM :
(ii) Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft-switches. Indications - Generator set, Utility Status Lamp.
(iii) Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours
(iv) AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), KVA (phase and total) and Frequency. kwh, Total & per phase (kw & KVA), PF, Utility Voltage and Freq.
(v) Engine Protection: Low lube oil pressure, High/Low coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level.
(vi) AC Alternator Protection: Over/Under Voltage, Over/Under Frequency, Loss of AC sensing. Over speed, Over Current.
(vii) Data Logging: Engine hours, Control hours and upto 5 recent fault codes
(viii)Configurable glow plug control, Cycle Cranking
(ix) 24 Volt DC operation, Sleep mode, Modbus interface (RS485 RTU),In Power compatible (PC based service tool), Certifications - meets the requirement of relevant ISO, EN, Mil Std. and CE standards
(e) Maintenance due alarm based on Engine Run Time and duedate, Exercisor scheduler
(f) Remote HMI, Digital electronic governor with temperature compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring. | - | - | - | - |
| 3.04 | (g) All pipe line connections, valves etc. required for the lube oils, fuel and cooling system
(h) Battery & Battery charger of rated capacity as per the alternator/ Engine compatibility.
(j) Mounting Arrangement shall be of the following:
(i) Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.
(ii) Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning.
(k) Fuel Tank of capacity 12 hrs running capacity along with Fuel pipe MS C class 25mm ID with bends , flanges , valves, tees and bends.
(l) Control / service cables shall be of 4cx 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables ,pvc insulated copper armoured, control panel for auxiliaries with starters for pumps, heaters etc.
(m) RCC foundation with necessary earth work ,PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work/ TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia securing with clips / 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6),even and smooth without using extra cement/ Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions.
(n) Acoustic Enclosure shall comprise of the following
(i)Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions
(ii) The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munsel green shade and a structural/ sheet metal base frame painted in black. or any other standard colour as specified by the OEM
(iii) High quality noise absorbent and fire-retardant grade acoustic insulation material (P.U. Foam) complying to IS-8183 designed to have optimum serviceability
(iv) Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship
(v) 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling arrangement inside the enclosure. | - | - | - | - |
| 4 | Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors of not less than 250 KVA /200 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lag , 303.4 HP minimum Required Power for Rated kVA (hp) along with AMF system with Acoustic Enclosure exhaust silencer Hospital Grade in line, as per the noise emmission standards (CPCB-IV) laid down by MoEF / CPCB Norms, | 1 | Each | - | - |
| 4.01 | (A) Engine comprising of the following:
The 250 kVA diesel engine genset (BS-5514) is designed for prime operation with an output of 250 kVA / 200 kWe. It is powered by engine power of 223 kW (approximately 303.4 HP), 6-cylinder, inline type with turbocharged aftercooled (TCAC) aspiration, having a displacement of 7.31 litres and bore × stroke of 108 × 133 mm and radiator liquid cooled. It operates at a compression ratio of 16.8:1 with a rated speed of 1500 RPM and an overspeed trip at 1650 RPM. The engine is equipped with a CRS/G3 governor and provides isochronous frequency regulation, ensuring stable performance.
The exhaust system allows a maximum back pressure of 17 kPa with an exhaust gas temperature of about 550°C and is fitted with an after-treatment system comprising DOC, SCR, and ASC. The engine electrical system includes a 12V, 35A charging alternator and a 2x12V, 180 Ah battery for starting. It runs on High Speed Diesel (HSD) as per IS 1460 standards, with a fuel tank capacity of 385 litres. The fuel consumption is approximately 53.5 LPH at full load and 39 LPH at 75% load.
The lubrication system has a sump capacity of 25 litres with an oil change interval of 500 hours. It uses 15W40 grade lubricating oil (API CI4+) with oil consumption limited to ≤0.06% of specific fuel consumption. The system is equipped with spin-on type oil filters (2 numbers), ensuring efficient filtration and reliable engine performance. | - | - | - | - |
| 4.02 | (B) Alternator comprising of the following:
The alternator of 250 KVA genset is designed ( IS- 13364) part-II for three-phase operation at 415 V and 50 Hz. The alternator delivers a rated current of 347.8 amps and is of 4-pole, rotating field type construction, ensuring efficient and reliable power generation. It is fitted with an automatic voltage regulator (AVR), maintaining voltage regulation within ±1% for stable output under varying load conditions.
The alternator is built with Class H insulation, capable of withstanding high temperatures, with a permissible temperature rise of up to 125°C. It is provided with a single sealed bearing, ensuring long service life with minimal maintenance. The alternator is coupled to the engine through a flex disc coupling, which helps in smooth power transmission and reduces vibration. Additionally, it is capable of handling unbalanced loads up to 25% of the rated current, making it suitable for practical site conditions and varying load distributions. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
CompleteTenderDocuments.pdf
Tender Documents • 0.71 MB
BOQ_869041.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .