Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Accepted-AOC work order has been awarded | |
| 2 | L2₹18.3 L+₹94,722 (5.47%)Rejected-Finance H 50 C SHAKARPUR DELHI 110092 | SHAHDARA | DELHI | 110092 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹18.5 L+₹1.1 L (6.61%)Rejected-Finance 5A 24 ANSARI ROAD DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | L3 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | Iluminators And Circuiteers L2 | M/S. A.K. Electricals L1 | ACE ENGINEERS BUREAU L3 |
|---|---|---|---|---|---|---|
| 1.00DSR | ||||||
| 1.00 | OD24983/2023-2024:DSR22 14.15.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) | 148 | metre | 10 ₹1,480 Lowest | 10 ₹1,480 Lowest | 65 ₹9,620 |
| 1.00 | OD24993/2023-2024:DSR22 14.16.3 S & L of following size DWC HDPE pipe ISI marked along with all accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal. | 102 | metre | 50 ₹5,100 | 10 ₹1,020 Lowest | 80 ₹8,160 |
| 1.00 | OD24984/2023-2024:1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm | 100 | metre | 10 ₹1,000 | 2 ₹200 Lowest | 60 ₹6,000 |
| 1.00 | OD25058/2023-2024:DSR22 12.13Supplying and erection of galvanised D iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc.as required. | 16 | each | 1 ₹16 Lowest | 2 ₹32 | 250 ₹4,000 |
| 1.00 | OD24985/2023-2024:7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm | 320 | metre | 1 ₹320 Lowest | 2 ₹640 | 13 ₹4,160 |
| 1.01 | OD24986/2023-2024:7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm | 300 | metre | 1 ₹300 Lowest | 2 ₹600 | 13 ₹3,900 |
| 1.01 | OD24987/2023-2024:5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 44 | metre | 1 ₹44 Lowest | 2 ₹88 | 13 ₹572 |
| 1.01 | OD24988/2023-2024:5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. | 22 | each | 1,500 ₹33,000 Lowest | 3,000 ₹66,000 | 4,100 ₹90,200 |
| 2.00AR | ||||||
Tender Value
₹22.9 L
EMD Value
₹45,748
Closing Date
22 Feb 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-II
MUNICIPAL CORPORATION OF DELHI OFFICE OF THE Ex. ENGINEER (ELECT)-II 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Installation of SHML pole with fittings at Gagan Vihar in ward no. 204 under Shahdara South Zone
2024_MCD_186874_1
EEE-II/SSZ/2023-24/41.1
Open Tender
Electrical Works
Works
120 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹45,748
19 Sept 2025
17 Feb 2024
23 Feb 2024
17 Feb 2024
22 Feb 2024
17 Feb 2024
Amount
OD24983/2023-2024:DSR22 14.15.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
OD24993/2023-2024:DSR22 14.16.3 S & L of following size DWC HDPE pipe ISI marked along with all accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal.
OD24984/2023-2024:1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
OD25058/2023-2024:DSR22 12.13Supplying and erection of galvanised D iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc.as required.
OD24985/2023-2024:7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
OD24986/2023-2024:7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
OD24987/2023-2024:5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
OD24988/2023-2024:5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
122.2.25:Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
122.2.26:Providing and fixing FRP Fencing at Electrical Installations with necessary concreting for grounding vertical post, hardware. Accessories, fitting, etc of 2000 mm height above the ground and 300 mm grounding in ground minimum along with fencing 1 number of FRP gate with necessary hardware, accessories, brass/stainless steel metal lock fittings etc of suitable length, width & height, width & height i.e. 1 number gate as per site requirement.
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.7: Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB 'C' characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick
122.2.10.a:Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
122.2.14:Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
122.2.16:Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipes with tightening bolts complete as required.
122.2.33:SITC of 60W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
Iluminators And Circuiteers
ACE ENGINEERS BUREAU
Bidder Name
ACE ENGINEERS BUREAU
Iluminators And Circuiteers
M/S. A.K. Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .