Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹46.3 L+₹28,148 (0.61%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹46.5 L+₹49,314 (1.07%)Rejected-Finance NO 650 3RD CROSS MATHIKERE BANGALORE 560 054 | BENGALURU URBAN | KARNATAKA | 560054 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹47.1 L+₹1.1 L (2.38%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹49.8 L+₹3.8 L (8.25%)Rejected-Finance SHOP NO 48 HOSANNA LAXMI VENKETESWARA LAYOUT 2ND CROSS MARAGONDANAHALLI K R PURAM POST BANGALORE 560036 | BENGALURU URBAN | KARNATAKA | 560036 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹58.5 L
EMD Value
₹1.1 L
Closing Date
20 Nov 2023, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIRS TO WASHROOMS OF 4 (T) MESS AT AFS JALAHALLI, BANGALORE
2023_MES_623764_1
85265/E8
Open Tender
Civil Works
Item Rate
180 days
GE (M) (AF) Jalahalli
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE(M) AF JALAHALLI
₹1.1 L
5 Jan 2024
17 Oct 2023
27 Nov 2023
17 Oct 2023
20 Nov 2023
7 Nov 2023
17 Oct 2023 - 24 Oct 2023
Amount
Taking down cement plaster including raking out joints hacking for key, scrubbing down with water etc, all as specified & directed.
M&L 10mm thick rendering in CM (1:6) on fair face of brick or concrete wall surface finished even & fair without using extra cement, all as specified & directed.
M&L 5mm thick rendering in CM (1:3) on concrete surface on ceiling, finished even & fair without using extra cement, all as specified & directed.
M&L three coats of white washing on ceiling including preparation of new plastered surface, all as specified & directed.
M&L for three coats of white washing on walls including preparation of new plastered surface, all as specified & directed.
Taking down chowkhats or frames with shutters area exceeding 1.5 Sqm and not exceeding 4 sqm each and removing from the site, all as specified & directed.
Taking down chowkhats or frames with shutters area not exceeding. 1.5 Sqm each and removing from the site, all as specified & directed.
M & L for 2nd class HW Plain, solid, straight in chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, all as specified & directed.
S&F for 35 mm thick 2nd class HW factory made panelled shutters with panel of 12 mm thick veneered commercial plywood kiln seasoned chemically treated with 15 x 6 mm teak wood edging all around the panels, all as specified & directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
S&F Factory made PVC choawkats or frames of size 50x 47mm with wall thickness made out of extruded 5 mm rigid PVC foam sheet mitered at corner and jointed with 2 Nos of 150mm long brackets of 15mm x MS square tube the vertical door prattles to be reinforced with 19 x 19 mm MS square tube of 19 gauge EPDM rubber gasket door frame to be fixed to wall using MS screws of 65/100mm size complete as per manufacture’s specification, all as specified & directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, all as specified and directed.
S&F MS butt hinges medium weight cold rolled 100 mm size, all as specified & directed.
S&F MS butt hinges medium weight cold rolled 75 mm size, all as specified & directed.
S& F Aluminium anoldised handle 150 mm long, all as specified & directed.
S& F Aluminium anoldised handle 125 mm long, all as specified & directed.
S&F Aluminium anoldised barrel tower bolt 125 mm long, all as specified & directed..
S&F 300 mm (length of bolt) mild steel sliding door bolt (bolt type) above enameled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, all as specified & directed.
M&L two coats of synthitic enamel paint over a priming coat of pink primer including preparation of untreated surfaces of wood or wood based material exc 10 cm width or girth, all as specified & directed.
S&F for sheet glass 3 mm thick ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane, all as specified & directed.
Taking down Steel Ventilator Frame (without taking off Shutter from the Frame) of any description including Guard Bars/ Grill, not exceeding 1.00 Square Metre Each, complete all as specified and as directed.
Taking down Steel Window frame (without taking off Shutter from the Frame) of any description including Guard Bars/ Grill, exceeding 1.00 Square metre but not exceeding 2.00 Square metre each, complete all as specified and as directed.
M&L Steel Window/Ventilator Box type using ERW ‘P’ Section comprising double frame for Gauged and Glazed Skeleton Shutters, having outer frame of Section 50x25mm and Inner Frame of Section 40x20mm, jointed internally with Mild Steel flat Iron 40x3mm complete with Stainless Steel tower Bolts, hinges, handles, stops, lugs, stays, etc. including Stainless Steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, incl steel painting and making good surface of wall by applying rendering to jambs and cills, etc., complete all as specified and as directed. NOTE :- (a) For the purpose of Measurement and Payment Double Shutters with Frame shall be considered as ONE UNIT. (b) Unit Rate quoted shall deem to be include all the Stainless Steel Builders & Hardware as required/directed at Site. (c) Quoted Unit Rate shall also deem to be include Mild Steel Guard Bars of 10mm Square Bar, spacing at 10 Cm centre to centre on both Vertical & Horizontal directions. (d) Sheet Glass shall be Measured and Paid for separately under appropriate Item.
Demolition and bracking up drain pipes 100 mm dia (salt glazed ware, AC or PVC, reinforced concrete) set in cement mortar incl bend and dimension piece etc, all as specified & directed.
Demolition and bracking up drain pipes 75 mm dia (salt glazed ware, AC or PVC, reinforced concrete) set in cement mortar incl bend and dimension piece etc. Complete.
S&F 110mm bore PVC pipe (SWR) single socketed in any length with rubber ring joints fixed to wall complete, all as specified & directed.
S&F 75mm bore PVC pipe (SWR) single socketed in any length with rubber ring joints fixed to wall/floors complete, all as specified & directed.
S & F for PVC (SWR) bends of 110mm bore of pipe provide with or without access door
S & F for PVC (SWR) branch piece,single (single Y) equal or unequal bore of pipe 110mm.
S & F for PVC (SWR) bends of 75mm bore of pipe provide with access door
S & F for PVC (SWR) branch piece,single (single Y) equal or unequal bore of pipe 75mm.
M&L in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement of dia of outlet 75mm and all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but incl screed bed and plaster.
S/F non skid tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc. set and jointed in neat cement sullery out pointed in white cement to match including screed or bedding layer of 15 mm thick in cement mortar 1:4 in floor finishes, all as specified & directed.
S/F for non skid tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc. set and jointed in neat cement sullery out pointed in white cement to match incl screed or bedding layer of 15 mm thick cement mortar 1:4 in floor finishes, all as specified & directed.
M&L glazed ceramic designer coloured tiles of size 450 x 350 x 7 mm thick as in vertical surfaces, set, jointed in neat cement slurry and pointed in white cement using pigment to match colour of tiles incl 10 mm thick cement plaster as backing coat in CM 1:4 complete all as specified & directed
Taking up or down steel tubing and connector 15 mm bore in wall, floor or ceiling, all as specified & directed.
Supply and laying of CPVC 16mm dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls, ceiling or laying in floors complete , all as specified & directed.
Cutting grooves in brick/stone wall for 15mm/20mm dia pipe, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, complete, all as specified & directed. .
S&F in repairs for 15mm bore stop value of PTMT of any colour, screwed for iron/UPVC pipes, all as specified & directed.
S&F for in repairs 15mm bore stop valves cast copper alloy fancy type chromium plate with long shank & cup (concealed type), all as specified & directed.
S&F in repairs PVC connections 15mm bore & 45 cm long with fly nuts on both ends complete, all as specified & directed.
supply and fixing In repairs 10 liter capacity PVC low cistern syphonic action type including inlet ball valve float, including brackets including all connections & flush pipes for EWC & indian type WC.
S&F in repair vitreous china wash down water closet, padestal pattern, white in colour including white seat cover ISI marked 'P' or 'S' trap, fixing bolt and jointing, all as specified & directed.
S&F in repairs for PTMT shower rose 75 mm dia, all as specified & directed.
S&F in repairs for push tap 15mm dia of any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms), all as specified & directed.
S & F in repair, Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
M & L for 2000 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including removing the dismantled water tank to MES store, all as specified & directed.
M & L for 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including removing the dismantled water tank to MES store, all as specified & directed.
M&L for taking down of existing sunken slab treatment from the sunken portion and removing of existing filling of sunken, cleaning the surfaces washing down with water and rubbish off the primises, cleaning and filling cracks with sealing compound and appling followong applications :- (a) brushing neat cement slurry @ 3.00kg/sqm and grouting 25mm thick cement concrete type B-0 (1:2:4) (using 12.5mm graded stone aggregate) on sunken slab portion including filling of brick bats and finishing the top surfaces even and smooth without using extra cement . (b) M&L for two coat of acrylic cementitious water proofing coating (Dr FIXIT pidfin 2K manufactured by M/S Pidilite industries Ltd or equivalent) and followed by a overlay protective screed 15mm thick CM(1:3) alongwith liquid water proofing as per manufacturer instructions on top surfaces of sunken slab after prepration as mentioned above method of application for acrylic cementitious water proofing coating (c) applying APP based polymeric membrane minimum weighing 4kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application is followed as per manufacturers instructions
M&L complete removal of old decorated wall surfaces of any description , cleaning the drops in the floor/shutters after treatment and applying three coats of white wash on walls all as specfied and directed.
M&L complete removal of old decorated ceiling surfaces of any description ,cleaning the drops in the floor/shutters after treatment and applying three coats of white wash on ceiling all as specfied and directed.
S&F Bib Tap 15mm bore, Chromium Plated, fancy type, Short/long Body with Capstan Head, screwed down, screwed for Iron Pipe or for Brass Ferrule , complete all as specified and as directed.
S&F Stop Cock 15mm bore, Cast Copper alloy, Chromium Plated, Fancy type with long Shank and Cup, screwed down, high pressure, with Crutch or Butter-fly Handle, screwed Both Ends for Iron Pipe or for Unions, complete all as specified and as directed.
S&F Tubular Towel Rail 20mm dia, Brass Chromium Plated, D-type, 60 Cm long between Flanges with Bracket (one Pair) , complete all as specified and as directed.
S&F for CP soap dish fixed to wall with chromium plated brass screws , all as specified and as directed.
S&F in repair waste coupling 32mm dia of PTMT (half or full thread) minimum weight 45 gram, removing the dismantled water tank to MES store, all as specified & directed.
S&F in repairs PVC waste pipe 32mm bore for WHB/urinal and all as specified and directed.
Taking down copper/aluminum point wiring (light fan, socket or power) complete including fittings such as switch, sockets, c/rose, pendents, regulators, sockets, light fittings, wooden boards, bell push, call bell, regulators etc (credit scheduled for above items should be made as per condition separately) and making good to disturbed wall and surface complete all as specified.
M&L for surface Point wiring using approved colour coding as per IS ( Red, black and green for single phase circuit ), with 1.5 Sq mm cross sectional area, single core, multi stranded copper conductor (FRLS) PVC insulated and unsheathed electrical cable ISI Marked and including medium grade PVC conduit of dia not less than 20 mm and conduit accessories surface including mild steel/pressed steel sunkun boxes (with earth dolly) dully painted with two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socktes etc including PVC insulated multi-stranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr in Charge at site for the following:-
Light point controlled by one piano type 5 amp switch complete all as specified
One Fan (Ceiling/Exhaust/Wall) point controlled by one piano type 5 amp switch and fan regulator complete.
One 3 pin socket outlet, 5 Amps independent board complete all as specified & as directed. (Switch, socket shall be measured separately).
One socket outlet 3 pin 5 Amps on the same board controlled by separate switch. (Switch, socket shall be measured separately).
All as per item No 61 here-in-before but with 2.50 Sq mm un-sheathed multistranded cable for one socket outlet 15 Amps independent including continuous copper earth wire, PVC insulated of 2.50 Sq mm size (Switch, Socket shall be measured and paid separately).
Note for item No 62 & 63:- Cost of cutting chassing and making good of disturbed surface all to match with existing surface deemed to quoted rates. (ii) Switch ,socket and regulator to be measured and paid separately in respective items.
M & L for switch piano flush type 6 Amps 240 volts single pole one way complete all as specified & as directed.
M&L for socket outlet 2 in 1 , 5 pin, 6 Amps flush type 240 volts complete all as specified & as directed.
M&L for switch piano flush type single pole one way 16 Amps, 240 volts
M&L for Socket outlet 2 in 1 ,5 pin 6/16 Amps, 2 in 1, flush type 240 volts complete all as specified & as directed.
M&L for ceiling rose surface bakelite, 3 terminal complete all as specified & as directed.
Supply and fix in repair the sub main wiring with 2 single core PVC insulated, unsheathed copper conductor stranded 1100 volt grade cable of size 2.5 sqmm (FRLS) drawn in and incl PVC rigid conduit medium grade of size not less than 20 mm dia ISI marked ivory white with all accessories such as tee, bend, joint cover etc PVC insulated,one run of unsheathed copper conductor stranded 1100 volt grade cable of size 2.5 sqmm (FRLS) cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete as specified and as directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Taking down of existing ceiling/Exhaust Fan from any height, opening and dismantling /rewinding greasing and painting of fans complete with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust, writting the MES with black paint etc and refixing of fans at same location including connecting up including provision of extension rod for rehanging and cable from ceiling rose to fan complete all as specified .
M & L for Replacement of Shutter / louver for exhaust fan 300 mm sweep made of metal Heavy duty type and Outer frame polish by grey paints and making good , matching with existing surface.
VARGHESECHACKO AND CO
Maruthi constructions
SRI MARUTHI BUILDERS
AURA ENTERPRISES
PRACHANIVA CONSTRUCTIONS
SAI MAX INFRAPROJECTS
K. VENKATESH NAIDU
D NAGI REDDY
SREE BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .