| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC AT KARGALI BAZAR BERMO DIST BOKARO PIN NO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | - | Rejected-Technical Bid not be opened as per NIT terms | |
| 3 | Rejected-Technical AT BALU BANKER COLONY PO DHORI BERMO DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹9.7 L
EMD Value
₹12,100
Closing Date
7 Sept 2024, 9:00 amClosed
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Laying of PVC cable for backup power of different offices under GM unit, G.M. Bunglow and electrical wiring at Area Accounts Office under G.M. unit, Dhori Area
2024_CCL_315836_3
GM(D)/SO(EnM)/DA/2024-25/28
Open Tender
Electrical and Maintenance Works
Item Wise
21 days
GM Unit, Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹12,100
23 Sept 2024
26 Aug 2024
9 Sept 2024
27 Aug 2024
7 Sept 2024
27 Aug 2024
27 Aug 2024 - 30 Aug 2024
Amount
Part A
Supply of PVC insulated cable 2 x 10 sq.mm + 1 x 6 sq.mm earth wire (For A.A.O. & G. M. Bunglow)
Laying of PVC insulated cable 2 x 10 sq.mm + 1 x 6 sq.mm earth wire (For A.A.O. & G. M. Bunglow)
Supply and fixing of 200A bus-bar , 4 way.
Supplying and fixing of following sizes of medium class PVC conduit, along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. : 40 mm
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, ‘’C’’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator). : 2 + 4 way/ 6 way, double door.
Part B: Electrical wiring at AAO
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required : 2 x 10 sq.mm + 1 x 6 sqmm for computer system and AC line
Supply and fixing of changeover switch 200 Amp.
Making switch board (M.S. angle 50 x 50 x 6mm)
Supply of wooden board 4’ x 2’ = 8 sft. x 2 nos.
Supply of G.I. nuts & bolts
Supply of lugs 150 Amp
Fixing of sl no. 1.16, 1.17, 1.18
Total impact of GST for the purpose of CTC
M/S KUMAR ENTERPRISES
M/S UPENDRA ELECTRICAL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .