Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹1.0 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.2 Cr+₹15.8 L (15.6%)Rejected-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹1.2 Cr+₹15.8 L (15.6%) | L2 | Rejected-Finance Higher Rate |
| 3 | L3₹1.9 Cr+₹91.0 L (90.1%)Rejected-Finance | ₹1.9 Cr+₹91.0 L (90.1%) | L3 | Rejected-Finance Highest Rate |
Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
29 Jan 2019, 3:00 pmClosed
SE,HEC,PWD
SUPERINTENDING ENGINEER (P.W.D) Health Electrical Circle KIT Annex Building, 5th FLOOR, KOLKATA 700073
Renovation of 3rd floor, 4th floor and Eastern side of 5th floor of Chest Cancer Block for relocation of Department of ENT within the campus of IPGMER - SSKM Hospital ------ SITC of Air Conditioning System.
2018_WBPWD_201762_1
WBPWD/SEHEC/SKHED/NIQ43/18-19
Open Tender
ELECTRICAL WORKS ORG
Item Rate
150 days
SSKM Hospital
Please refer Tender documents.
6 documents required · 6 mandatory
₹3.2 L
Office of the SE,HEC,PWD
10 Feb 2021
14 Dec 2018
31 Jan 2019
15 Dec 2018
29 Jan 2019
28 Dec 2018
19 Dec 2018
Amount
SUB-HEAD A - CHILLER
Supply, Positioning, Starting, Testing & Commsioning of AHRI / Eurovent certified Air Cooled Screw Chiller of capacity stated below at operating condition mentioned below having single/multiple screw compressor driven by suitably rated hermetic / semi hermetic motor complete with VFD and with all standard accessories. Air cooled condenser with factory coating against corrosion, insulated flooded / Dx chiller, flow switch at chiller outlet, interconnecting insulated refrigerant piping, refrigerant & oil (first charged), micro processor based control panel, 1" deflection screen isolator of suitable capacity all mounted on MS baseplate. Motor shall be suitable for 415V ±10%, 50 Hz ± 5%, 3-Ph AC supply. Variable speed drive shall have suitable harmonic filter. Operating conditions are furnished below:
Minimum Refrigeration Capacity - 85 TR (Actual) at the following operating conition and AHRI condition (1 Working + 1 Standby)
Refrigerant - 134 A
Chilled Water Inlet Temp - 14.5 °C
Chilled Water Outlet Temp - 6.5°C
Fouling factor Evaporator & condenser as per ASHREE and AHRI
IPLV as per latest BEE circular for ECBC buildings.
Ambient Temparature : 45 °C
IKW/TR at design condition shall be as specified by AHRI
Required cushy foot mounting & flexible below arrangement
[Make - As per Approved Make]
SUB-HEAD B- CHILLED WATER PUMP
Supply, Installation, Testing and Commissioning of Back - Pullout Casing Chilled water pump set capable of delivering 255 USGPM of water . duly insulated with 32mm thick Nitrite Rubber , Each comprising of Suitable HP, TEFC Squirrel Cage Induction Motor with class "B" insulation, 1440 rpm synchronous speed, suitable for operation on 415 ± 10% volts, 3 phase, 50 Hz A.C. supply. The Pump / Motor shall confirm to IE2 Standard and 81.4% Efficiency. 150 mm dia dial type pressure gauges for inlet & outlet, mounted on common MS base plate, complete as per specifications etc. as required. (1 Working + 1 Standby) , The pump shall have IP65, all weather proof, isolator with lockable arrangement.
The item included suitable cush foot mounting arrangement with rubber flexible below.
[Make - As per Approved Make]
SUB-HEAD C - AHU
FLOR MOUNTED AHU
SITC of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of preplasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6/8 row deep (as given below) , filter section with 50 mm thick metal viscous/ washable synthetic
pre-filter (90% down to 10 micron) and fine filter (95% down to 5 micron), belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications including SITC of suitable VFD (Make as per approved Make list) drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following Capacities [Make - As per Approved Make]
8 row deep cooling coil and 125 MM total Static Pressure
1600CFM outdoor type AHU with 43±2mm thick panel with thermal break profile.
6 row deep cooling coil and 70 MM total Static Pressure
CEILING SUSPENDED AHU
SITC of factory built ceiling suspended type double skinned chilled water air handling units fabricated out of extruded aluminium section with 0.6mm pre-plasticized / pre coated galvanised steel sheet outside & 0.6mm plane galvanised steel sheet inside with farward curved blower, blower section and blower motor TEFC type suitable for operation on 415 ± 10% V, 50Hz± 5% , 3 Phase AC supply, 6 row cooling coil made of Aluminium finned copper tube with coil section, pre filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% and fine filter 95% down to 5 micron (fine filter for 70 TSP AHU), polished stainless steel drain pan made out of 22SWG sheet duly insulated complete with motor , direct / belt drive as mentioned below etc. without face and bypass dampers. All direct driven fan motor shall be sourced from fan manufacturer & factory fitted only.
The AHU panel shall be insulated with 23mm thick & 36 kg/m3 density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 152 MPM maximum. The supply blower motor shall be VFD operated including SITC of suitable VFD & their necessary control etc as required. The capacity of Air handlers shall be as follows : [Make - As per Approved Make]
40 MM total Static Pressure
70 MM total Static Pressure
UVC EMITTER.
a) SITC of UVC EMITTER for the above AHU's for prevention of fungus in the chilled water cooling coils. The minimum UV intensity in the coils shall be greater than 1000 UW-SEC/CM2 for OTs. The unit shall be UL Listed (UL-1995) [Make - As per Approved Make]
b) SITC of UVC EMITTER for the above AHU's for prevention of fungus in the chilled water cooling coils. The minimum UV intensity in the coils shall be between 600 to 700 UW-SEC/CM2 for Ots. The unit shall be UL Listed (UL-1995) [Make - As per Approved Make]
SUB-HEAD D - CHILLED WATER PIPING SECTION [Make - As per Approved Make]
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. [ Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
150 mm dia. (32 mm thick insulation)
125 mm dia. (32 mm thick insulation)
100 mm dia. (32 mm thick insulation)
80 mm dia. (32 mm thick insulation)
65 mm dia. (32 mm thick insulation)
50 mm dia. (32 mm thick insulation)
40 mm dia. (32 mm thick insulation)
32 mm dia. (19 mm thick insulation)
SUB-HEAD D - CHILLED WATER PIPING VALVES & FITTINGS [Make - As per Approved Make]
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot heater circulation as specified
150 mm dia.
125 mm dia.
100 mm dia.
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
Ball Valve
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
150 mm dia
125 mm dia
100 mm dia.
80 mm dia.
65 mm dia
50 mm dia.
40 mm dia
32 mm dia
Auto Air Vent with Ball Valve
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
125 mm dia Each
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
125 mm dia
S&F of water Flow switch
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometres.
Supply, Installation, Testing and Commissioning of following sizes electronic, 3 way modulating control valve with thermostat. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
SUB - HEAD E - DUCT WORKS INCLD ALL ACESSORIES [Material Make - As per Approved Make]
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Fire damper
Actuator
Supplying, fixing, testing & commissioning of Variable air volume box to control the air delivery volume complete with actuator, thermostat, corded remote and linkages. [Make - Honeywell / Systemair / JCI / Trane/Diakin/Trox/Johnson].
DUCT THERMAL & ACOUSTIC INSULATION
Supply and fixing of acoustic lining of supply air duct and plenumn with Supplying & fixing of 10mm thick open cell nitrile rubber (class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
32mm (FOR NON ac ZONE)
Supply & fixing of underdeck insulation with 50mm thick TF quality Expanded polysterene slab.
DUCT THERMAL INSULATION FOR DUCT FOR NON-AC ZONE
Supply and fixing of Opposed blade GI Duct Damper of 18 G GI sheet and frame.
Supplying, fixing, testing & commissioning of powder coated extruded aluminium section fresh air grill in AHU room with aluminium volume control dampers, bird screen etc complete as required.
a) 4.5 kw in 3 Banks
S & F of HEPA Filter with efficiency of 99.99% down to 0.3 microns of size 600 mm x 600 mm x 150 mm (Thk) as per actual site requirement for OT area and to accommodate inside the laminar bench chamber as per approved drawing.
SITC of Aluminium laminar bench with perforated sheet cover to accommodate inside HEPA filter bank along with necessary support as per standard of minium 6 ft X 8 ft dimension for OT Area as per approved drawing.
DRAIN PIPE FOR CHILLED WATER SYSTEM WITH INSULATION:-
SITC of Drain piping with GI B Class pipes with fittings duly insulated with 25 MM THICK "TF" qulaity (16 Kg/CuM density) EPS section, Vapour barrier and covered with sand, cement and plaster with GI chicken wire mesh along with necessary quantities of supports, flanges, bends, elbows, fittings, nutbolts,gaskets etc:
a) 50 mm NB
b) 40 mm NB
Supply and installation of 1000 L HDPE Expansion Tank (Mk.Patton/Syntex) along with 1 No Float Valve and 3 Nos isolation valves for necessary connections including thermal insulation work by 75 mm thick Expanded Polystyrene covered with GI Chicken wire mesh, vapour barrier and 12 mm thick sand cement plaster cover [ Make - As per Approved Make]
SITC of Inline fan for OT exhaust as per actual site requirement for successful performance. [ Make - As per Approved Make]
a) Exhaust Fan of Capacity - 175 CFM 10 mm WC
b) Exhaust Fan of Capacity - 850 CFM 10 mm WC
DUCTABLE SPLIT:
SITC of Air-cooled Ductable split units comprising of Indoor & Outdoor units with micrprocessor based controls a complete in all respects inclusive of 10 mts of refrigerant piping, insulation and cabling, thermostat and operating switches as required and of following capacities suitabel to run with R407c refrigerant incl S&F of MS structure for outdoor unit . Make- [Hitachi/Carrier/ Voltas/Blue star].
a) 3TR (For male cabin 2 & voice clinic at western side of 4th floor).
ELECTRICAL PANEL
Design, Manufacture, testing, supply, installation and commissioning of Double door outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable for short circuit fault of 31 MVA at 415 Volts, fabricated as per size, design & drawing to be approved by EIC. The Enclosure shall provide Degree of protection IP -54 in accordance with IS : 2147 -1962 with its latest ammendmentThe feeder pillar box will be fabricated by CPRI approved fabricator as per detail specification attached ( uploaded in the specification section).
VFD Bypass AHU Starter Panel for other than OT Area [ Make - As per Approved Make]
Supply, installation, testing and commissioning of wall mounted cubical type LT distribution control panel, VFD Bypass Starter Electrical Panel Board fabricated from sheet steel comprising with following accessories incl. internal wiring earthing & painting.
a) MCCB suitable rating as incomer & MCBs as outgoing per the ratings of AHU motor and Heater
b) DOL / SD starter as per HP ratings
c) VFD Bypass Starter as per HP ratings
d) Terminal block for power distribution.
e) Contactor, auxilary contractor, over load relay, with inbuilt single phasing protection.
f) Phase indicating lights and indicating light for ON , OFF & TRIP status.
g) Wiring for microswitch for stopping the fan when fire damper closes.
h) Panel mounted digital Ammeter in 96x96 mm² ) [0 - 50 Amp.]
(i) Panel mounted digital Voltmeter in 96x96 mm² [0 - 500 V]
(j) One no DC Relay for sensing Fire Detection system.
(k) Danger Board.
VFD Bypass AHU Starter Panel for OT AREA [ Make - As per Approved Make]
Supply, installation, testing and commissioning of wall mounted cubical type LT distribution control panel ,VFD Bypass Starter & exhaust fan control Electrical Panel Board fabricated from sheet steel comprising with following accessories incl. internal wiring earthing & painting. (For OT areas).
a) MCCB suitable rating as incomer & MCBs as outgoing as per the ratings of AHU motor and Heater
b) DOL / SD starter as per HP ratings
c) VFD Bypass Starter as per HP ratings
d) Terminal block for power distribution.
e) Contactor, auxilary contractor, over load relay, with inbuilt single phasing protection.
f) Phase indicating lights and indicating light for ON , OFF & TRIP status.
g) Wiring for microswitch for stopping the fan when fire damper closes.
h) Panel mounted digital Ammeter in 96x96 mm² ) [0 - 50 Amp.]
i) Panel mounted digital Voltmeter in 96x96 mm² [0 - 500 V]
j) One no DC Relay for sensing Fire Detection system.
k) Danger Board.
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) Al cable conforming to IS: 7098 / 1988 with its latest amendment of following size.
4Core 240 Sq. mm
3Core 16 Sq. mm
3Core 10 Sq. mm
3Core 6 Sq. mm
Supplying of one number 1.1 KV Grade XLPE insulated unarmoured Cu cable
7 core 2.5 sq.mm
3 core 2.5 sq.mm
Laying of cable as below, through existing cable tray/surface on wall as per direction of the EIC.
4Core 240 Sq. mm
3Core 16 Sq. mm
3Core 10 Sq. mm
3Core 6 Sq. mm
7 core 2.5 sq.mm
3 core 2.5 sq.mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured/unarmoured cables as below including finishing the end of following XLPE/PVC armoured/ unarmoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4Core 240 Sq. mm
3Core 16 Sq. mm
3Core 10 Sq. mm
3Core 6 Sq. mm
7 core 2.5 sq.mm
3 core 2.5 sq.mm
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support With S&F 25x25x3mm angle iron support
Charges for cutting wall / floor for entry of different sizes duct & pipe lines including mending good the damages and removal of rubbish as per direction of EIC.
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
VOLTAS LIMITED
Ingersoll Rand Climate Solutions Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .