| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.9 L+₹39,558.50 (1.93%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L2 | Rejected-Finance L2 | |
| 3 | L3₹22.5 L+₹1.9 L (9.37%)Rejected-Finance 296 SECTOR 15 PANCHKULA HARYANA | L3 | Rejected-Finance L3 | |
| 4 | L4₹24.6 L+₹4.0 L (19.6%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹26.2 L+₹5.7 L (27.7%)Rejected-Finance SANTOKH VILA 81 1ST FLOOR PHASE XI MOHALI PUNJAB 160082 | 160082 | L5 | Rejected-Finance L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
26 Jun 2024, 6:00 pmClosed
Garrison Engineer Chandimandir
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-15/2024-2025 REPAIR OF CEILING FANS, EXHAUST FANS, WALL MOUNTING FANS IN MD / OTM AT CHANDIMANDIR MIL STN
2024_MES_656460_1
GE/CHM-15/2024-2025
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹50,000
Yes
6 Nov 2024
29 May 2024
29 Jun 2024
29 May 2024
26 Jun 2024
12 Jun 2024
Amount
Taking down existing Ceiling fan, exhaust fan, cabin fan of any type carefully from any differnt location for repair and kept safely and refixing the same after repair, complete all as specified and directed. Note :- Necessary T&P such as ladder, helper etc shall be arranged by the contractor. (Repairs & spares shall be measured and paid separately under respective item of BoQ)
Winding of motor of 1200/1400mm sweep ceiling fan of any make with super enameled copper winding wire of existing gauge (Approx wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.5 Sqmm of length not more than one meter with each fan including white synthetic enamel spray painting of fan and blade after rewinding complete all as specified and directed. Make of winding wire : New India/ Jindal/ Devidyal/ HTP Make of varnish : Doctor brand or equivalent. Make of Copper flexible wire : Plaza/Finolex/Kalinga Notes : (i) Other spares shall be measured and paid separately under respective item of Sch ‘A’. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (iii) All repair/rewinding work will be carried out in MES Store yard/work shop only and mark the CA No with repair/rewinding date on the fan before handing over to the department and maintain the proper handing/taking record with date. Any fan repair/rewinding by contractor and found defective within waranty period i.e one year from the date of repair/rewinding the contractor will repair/ rewinding the same without any extra cost. (iv) Contractor will return the fan after rewinding and testing within 4 days from the date of taken over, if not a panelty @ rate of Rs 50/ fan per day will be charged.
All as per item 2 here-in-before but for exhaust fan 300 mm sweep.
All as per item 2 here-in-before but for exhaust fan 380 mm sweep.
All as per item 2 here-in-before but for exhaust fan 450 mm sweep.
All as per item 2 here-in-before but for cabin fan 400mm sweep.
All as per item 2 here-in-before but for Pedelstal fan any sweep
Spray painting of ceiling fan complete with one coat of synthetic enamel paint (white) after taking down from the position, cleaning, washing , rubbing including filling cavities with filler etc and testing complete all as specified and directed.
Capacitor AC 220/230 volts 2.5 / 3.0 mfd fixed as in repair complete all as specified and directed. MAKE : USHA / EPCOS/HAVELLS
All as per item 9 here-in-before but 4 mfd.
Stepped type fan regulator flush type on the exisiting laminated sheet as required, fixed as in repair complete all as specified and directed.
Step type modular fan regulator 02 module, 120 watts , fixed as in repair complete all as specified and directed.
Rubber bush with split pin , fixed as in repair complete all as specified and directed.
Armature shaft for ceiling fans of 1200/1400 mm sweep of any make, fixed as in repair complete all as specified and directed.
Ball bearing No. 6202 fixed as in repair complete all as specified and directed. Make : NBC /SKF (bearing with 8 balls shall only be used)
All as per item No 15 here-in-before but No. 6203
All as per item No 15 here-in-before but No. 6204
Gun metal bushes of ceiling fan/ exhaust fan cabin fan of any make and any model and any sweep, fixed as in repair complete all as specified and directed.
Fan blades (Set ot three) for 1200mm sweep ceiling fan made out of Aluminium suitable for any make with existing colour for one ceiiling fan with set of screws fixed as in repair complete all as specified and directed. MAKE : BAJAJ/USHA/CROMPTON GREAVE
Fan blades (Set ot three) for 1400mm sweep ceiling fan made out of Aluminium suitable for any make with existing colour for one ceiiling fan with set of screws fixed as in repair complete all as specified and directed. MAKE : BAJAJ/USHA/CROMPTON GREAVE
Exhaust fan blades for 300/350/450mm sweep made out of metal suitable for any make / type with existing colour complete all as specified and directed.
Wall mounted fan blades for 450mm sweep made out of metal suitable for any make / type with existing colour complete all as specified and directed.
Louver shutter of metal body for exhaust fan complete suitable for 300-380mm sweep including fixing with nuts, bolts and washer, fixed as in repair compelte all as specified and directed. MAKE : KHAITAN/USHA/Crompton Greave
All as per item 23 here-in-before but for 450mm sweep
15mm down rod of length 45cm made out of heavy grade M. S. pipe with necessary threading at both ends, holes as required painted to match with existing colour with hanging clamp for ceiling fan 1200/ 1400mm sweep fixed as in repair complete all as specified and directed.
15mm down rod of length 60cm made out of heavy grade M. S. pipe with necessary threading at both ends, holes as required painted to match with existing colour with hanging clamp for ceiling fan 1200/ 1400mm sweep fixed as in repair complete all as specified and directed.
15mm down rod of length 90cm made out of heavy grade M. S. pipe with necessary threading at both ends, holes as required painted to match with existing colour with hanging clamp for ceiling fan 1200/ 1400mm sweep fixed as in repair complete all as specified and directed.
Taking down old rusted frame of exhaust fan of 380/ 400mm sweep, supply and fix new frame of same capacity with MS flats of suitable size with nuts, bolts and washer as required at site complete all as speicifed and directed.
Upper & lower canopy (set of two) made of good quality PVC with tightening screws of required size for any make of ceiling fan fixed as in repair complete all as specified and directed.
Rubber reel of fan with MS split clamp, two Nos nuts,bolts and washer complete set of appropriate size for hanging of ceiling fan, fixed as in repair complete all as specified and directed .
Mohinder Pal and Sons
KAPOOR ENGINEERS
M/s Prakash Enterprises
chahalbuilders
M/S Gupta and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .