Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | ₹36.9 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹37.0 LRejected-AOC | ₹37.0 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹37.3 LRejected-AOC | ₹37.3 L | L3 | Rejected-AOC Rejected |
Tender Value
₹37.0 L
EMD Value
₹73,979
Closing Date
17 Jan 2026, 6:00 pmClosed
Executive Engineer, DED, GTA
Executive Engineer, DED Landal House, Lalkothi Complex, GTA
Construction of Alternative approach Road (RCC) including Retaining Wall and Entrance Gate of District Hospital (EDEN), Darjeeling, GTA
2025_GTA_979803_1
GTA/ED/Engg/HFW/EE/DED(ES-I)/ NIeT- 71/2(1st Call)/e-Tender/2025-26
Open Tender
CIVIL WORKS
90 days
Darjeeling
As per NIeT
4 documents required · 4 mandatory
₹0
₹73,979
Office of the Executive Engineer, DED, GTA
9 Mar 2026
26 Dec 2025
20 Jan 2026
27 Dec 2025
17 Jan 2026
29 Dec 2025
29 Dec 2025
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.
Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1.500 mm.
Dry Rubble Flooring Construction of dry rubble flooring at cross drainage works for relatively less important works.
Cement concrete with 30mm down graded shingles excluding shuttering.a) Stone metal (N.B) variety. a) (1:3:6) proportion
Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or staight including fitting fixing and striking out after complection of works. (upto roof of ground floor).(a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of the Engineer-in-charge.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix ormula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4m.(i) Tor steel/Mild steel.SAIL/TATA/RINL
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification A) Granular material.
Dry Rubble Flooring Construction of dry rubble flooring at cross drainage works for relatively less important works.
Cement concrete with 30mm down graded shingles excluding shuttering.a) Stone metal (N.B) variety. a) (1:3:6) proportion
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix ormula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(b) River bazree
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4m.(i) Tor steel/Mild steel.SAIL/TATA/RINL
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.
Dry Rubble Flooring Construction of dry rubble flooring at cross drainage works for relatively less important works.
Cement concrete with 30mm down graded shingles excluding shuttering.a) Stone metal (N.B) variety. a) (1:3:6) proportion
Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or staight including fitting fixing and striking out after complection of works. (upto roof of ground floor).(a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of the Engineer-in-charge.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix ormula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4m.(i) Tor steel/Mild steel.SAIL/TATA/RINL
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. Area of each Granite slab > 0.6 upto 1.0 square metre. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]
Add 18% GST
Add 1% Cess
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_2388641.xls
BOQ • 0.35 MB
WBF-2911.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid