Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹13.8 L+₹47,285 (3.56%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹14.1 L+₹83,065 (6.25%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹14.2 L+₹87,733 (6.60%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹14.2 L+₹90,840 (6.84%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹26,600
Closing Date
4 Jan 2021, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
SPECIAL REPAIR TO BLDG NO P-23 AT LGJ MIL STN
2020_MES_397933_2
8931-42/20-21
Open Tender
Civil Works
Item Rate
GE Lalgarh Jattan
Class E Cat (a)(i),(b)(I)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹26,600
Yes
30 Jan 2021
12 Dec 2020
7 Jan 2021
12 Dec 2020
4 Jan 2021
21 Dec 2020
Amount
B/R Portion Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer - in Charge..
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed by Engineer - in Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcment cut as required to faciliate demolition) complete all as specified and directed by Engineer - in Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer - in Charge.
M&L for brickwork with fly ash bricks, straight or curved exc. 6 m mean radius built in cm 1:6 complete all as specified and directed by Engineer - in Charge.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) light shed polished, area of each tiles exceeding 0.36 sqm,but not exceeding 0.42 sqm in floors etc. over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and directed by Engineer - in Charge.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) light shed polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm,on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and directed by Engineer - in Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer - in Charge.
M&L for glazed ceramic coloured tiles of size 350 X 250 X 7 mm / 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer - in Charge.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer - in Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer - in Charge.
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
M&L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregrate in Chajjas. complete all as specified and directed by Engineer - in Charge.. Note : Reinforcement shall be measured and paid seperately.
S&F mild steel TMT bars (fe-500D) 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip complete all as specified and directed by Engineer - in Charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and directed by Engineer - in Charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 on wall finished even and fair complete all as specified and directed by Engineer - in Charge.
M&L for two coats of oil bound distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty over a coat of primer including preparation of surfaces complete all as specified and directed by Engineer - in Charge..
M&L for complete removal of existing treatment and two coats of oil bound distemper over 3 mm thick wall care putty on plastered surfaces of walls over a coat of primer including preparation of surfaces complete all as specified and directed by Engineer - in Charge..
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc.complete all as specified and directed by Engineer - in Charge.
M&L for two coats of cement base paint on newly / old plastered surfaces over a coat of primer incl preparation etc. complete all as specified and directed by Engineer - in Charge.
Dismantling of brick tiles in floor laid dry and pointed in cement morter complete all as specified and as directed by engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and directed by Engineer - in Charge.
M&L PCC (1:7:12) using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified and directed by Engineer - in Charge.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 and finished fair and even including mixing of WPC in mortarcomplete all as specified and directed by Engineer - in Charge.
Supply only integrated water proofing compound complete all as specified and directed by Engineer - in Charge. Make:- Dr Fixit/Fosroc/BASF/STP
M&L For roof treatment to RCC Roof as follows:- (a) Cleaning the roof surfaces throughly using wire brushes to ramove sharp projections,cleaning joints,washing,drying and removing all dirt/dust to receive concrete padding plaster etc. (b) Providing 15mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Provide one coat of approved bituminus primer @ 100 gms per sqm over dried plastered surface. (d) Laying 3mm thick APP membrane (mineral finish) reinforced with non woven polyster fabric by torch application. the overlapping while torching shall be 75mm on longitudnal direction and 100mm on the transverse direction complete all as sppecified and directed by engineer in charge. Make:- STP, Dr fixit/pidilite,Texca india ltd/Tikitar Dansona /Bengal Bitumen Notes:-(I)all joints and change in direction should be covered with cement mortar (1:3) mixed with SBR latex @ 200ml/bag of cement as per site requirment and cured well before laying membrane by torching. (II) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised aplicator of manufacturer only. the name of firm shall be got approved from GE before carring out the work . (iv) The independent testing of membrane for technical parameters given in perticular specifications shall be carried out from Govt approved labs having facilities for testing of membrane. (v) The guarntee of treatment shall be for minimum 10 yrs reckoned from date of complition of whole work.
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work etc complete all as specified & directed by Engr-in-Charge.
S&F Framed work such as grills,gratings,etc. With ends of bar shouldered or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings frame work of watertanks and similar works conforming to fe. 290 Gde-E-165 complete all as specified and directed by Engineer - in Charge.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. complete all as specified and directed by Engineer - in Charge.
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer - in Charge.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer - in Charge.
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed by Engineer - in Charge.
S&F framed work as in chowkats of doors windows of angle iron ,gates or other section with gusset plates, rails, braces etc conforming to Gde Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S&F hold fast of flat iron 25 x 3 mm conforming to Fe-290 or Fe 330 including preparing the surfaces & treated with two coats for coaltar & sanded with clean sharp sand complete all as specified and directed by Engineer - in Charge.
S&F powder coated aluminium frame/shutter for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of poweder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete in all respect all as specified & directed by Engr-in-Charge. Make of Al Section : Jindal / Hindalco / NALCO
S&F powder coated anodised aluminium fully glazed window & ventilator door shutters side hung type, aluminium section weighing exc. 0.55 kg/ m (1.50 to1.80mm th) including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws etc. long handles 2 Nos, hinges type B-21 100 mm long (4 Nos), Al door stopper, PVC door chock in each door shutter and necessary accessary as required complete all as specified and directed by Engir-in-Charge (Note : Glass/grill will measured and paid separately) Make of Al Section : Jindal / Hindalco / NALCO
M&L 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 Sq. m in each pane with solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed by Engineer - in Charge.
M&L for Cement concrete 1:3:6 type C–1 (using 20mm graded crushed stone aggregate) as in coping, hold fast, bed blocks or similar block etc complete all as specified and directed by Engineer - in - Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing all as specified and directed.
S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded both side Prelam PVC `C' channel having a PVC sheet strip of 20 mm width stuck and both side Prelam PVC sheets for top rail and bottom rail, panelling of both side Prelam PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame complete all as specified and directed by Engineer - in Charge.
S&F 100 mm long butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anosied and fixed type B-21 complete all as specified and directed by Engineer - in Charge.
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and directed by Engineer - in Charge.
S&F 150 mm long aluminium anodised handle, cast type complete all as specified and directed by Engineer - in Charge.
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and directed by Engineer - in Charge. (Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.)
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in Charge.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer - in Charge.
S&F flush shutter 25mm thick solid core construction with block board core and plywood face panels; commercial type on both sides as cupboard and kitchen shutters complete all as specified & directed by Engineer-in- charge.
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified and directed by Engineer - in Charge.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engineer - in Charge.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt type not less than 16mm dia fixed complete all as specified and directed by Engineer - in Charge.
S&F as 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed by Engr-in-Charge.
M&L Block board, 19/20mm thick, grade 1 quality, exterior grade, decorative type with decorative face veneer on both face, fixed with screws to timber frame work complete all as specified and directed by Engineer - in Charge.
M&L plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3 & n.exc 6 Sq.cm of 2nd class hard wood complete all as specified and directed by Engineer - in Charge.
S&F continous (piano) hinges, mild steel, bright finish or electrogalvanised (width of flaps 30mm ) complete all as specified and directed by Engineer - in Charge.
S&F 125mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer - in Charge.
S&F 125 mm long aluminium anodised handle, cast type complete all as specified and directed by Engineer - in Charge.
S&F Stainless steel wire cltoth 0.63mm nominal dia of wire and average width of of aperture 1.40mm and fixed with stain less steel wire staples complete all as specified and directed by Engineer - in Charge.
.---- ditto---- all as per serial item No 58 above but fixed in repairs complete all as specified and directed by Engineer - in Charge.
M&L 12 mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engineer - in Charge.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer - in Charge.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer - in Charge.
S&F drapery rods, coloured, standrad quality, powder coated not less than 25mm dia with heads at both ends and middle support, rings, etc.complete all as specified and directed by Engineer - in Charge.
S&F in repair stainless steel grating round or square 150mm size (minimum weight 100gms) complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
S&F in repairs vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests (excl flushing cistern) but including CI 'P' trap set in and including concrete fixed complete all as specified and directed by Engineer - in Charge.
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed by Engineer - in Charge.
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in 1:3 CM including 32mm dia chromium plated waste coupling/trap complete all as specified and directed by Engineer - in Charge.
S&F pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed by Engineer - in Charge. Wt not less than 450 gms
S&F in repair bib tap, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule & fixed suitable for 15mm bore iron pipe complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS.
S&F in repair angle valve/stop cock/stop valve fancy type, cast copper alloy, chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union, size 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS.
S&F in repair 15mm Concealed stop cock fancy type, cast copper alloy, chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union, size 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of concealed stop valve shall be as given in SSR or in relevant IS.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer - in Charge.
Disconnecting existing of water tanks of capacity exc 500 and n.exc 1000 ltrs, setting aside (or lowering if reqd) for repair cleannig, etc and hoisting if reqd reconnecting and re-fixing in position and removing from site complete all as specified and directed by Engineer - in Charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair all as specified and as approved by GE/Engineer-in-Charge.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engineer - in Charge.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipecomplete all as specified and directed by Engineer - in Charge.
.-- ditto--- all as per serial item No 77 above but for 20mm dia pipe complete all as specified and directed by Engineer - in Charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer - in Charge.
.-- ditto--- all as per serial item No 79 above but for 15mm dia pipe fixing only complete all as specified and directed by Engineer - in Charge.
.-- ditto--- all as per serial item No 79 above but for 20mm dia pipe complete all as specified and directed by Engineer - in Charge.
.-- ditto--- all as per serial item No 79 above but for 20mm dia pipe fixing only complete all as specified and directed by Engineer - in Charge..
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required upto 100mm dia complete all as specified and as directed by engineer-in-Charge.
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required 75mm dia complete all as specified and as directed by engineer-in-Charge.
Supply & fixing 100 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in Charge.
Supply & fixing 75 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in Charge.
Fixing only 100 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in Charge.
Fixing only 75 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in Charge.
M&L in repairs 75mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F in repairs branch pieces single (equal or unequal) ordinary or inverted (spring or socket type) or with paralled branch 100mm dia but with oval access door. complete all as specified and directed by Engineer - in Charge.
S&F in repairs branch pieces single (equal or unequal) ordinary or inverted (spring or socket type) or with paralled branch 75mm dia but with oval access door. complete all as specified and directed by Engineer - in Charge.
S&F in repairs 75mm cast iron sanitary connections-short connections pipe of length upto 300mm with socket fixed complete all as specified and directed by Engineer - in Charge.
S&F in repairs 100mm cast iron sanitary connections-short connections pipe of length upto 300mm with socket fixed complete all as specified and directed by Engineer - in Charge.
S&F in repairs 75mm bore cast iron bends (any radius) dimining pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engineer-in-Charge
S&F in repairs 100mm bore cast iron bends (any radius) dimining pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engineer-in-Charge
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overalll as fixed along the cente line over fittings and accessories) complete all as specified and directed by Engineer - in Charge.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer - in Charge.
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer - in Charge.
S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal complete all as specified and directed by Engineer - in Charge.
S&F 110 mm dia PVC (SWR) bend any radius complete all as specified and directed by Engineer - in Charge.
S&F 75 mm dia PVC (SWR) bend with access door any radius complete all as specified and directed by Engineer - in Charge.
S&F PVC (SWR) floor trap, 75 mm dia with grating including jointing with solvent cement etc complete all as specified and directed by Engineer - in Charge..
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer - in Charge.
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer - in Charge.
E/M Portion Taking down carefully copper/aluminum point wiring (light, socket or power) complete (fittings such as switches, ceiling rose, pendent, regulator, sockets etc to be measured separately), and making good disturbed surfaces of wall, floors etc to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer-in- Charge
M&L for concealed point wiring with two single core PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 Sqmm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 Sqmm (FRLS) including MS shunk sheet metal box with 3 mm thick hylam sheet top cover of required size for mounting switches, sockets etc for one light/fan point controlled by one, one way switch complete all as specified and directed by Engineer-in-Charge Note - Quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour. Note :- Additional point wiring other than the existing.
.--- ditto--- all as per serial item No 107 above but for one 3 pin switch socket outlet, 5 Am on the same board with other switches complete all as specified and directed by Engineer - in Charge.
.--- ditto--- all as per serial item No 107 above but for one 3 pin 5 Amps switch socket outlet point on independent board complete all as specified and directed by Engineer - in Charge.
.--- ditto--- all as per serial item No 107 above but for two way point controlled by two way switch complete all as specified and directed by Engineer - in Charge.
.--- ditto--- all as per serial item No 107 above but wiring with 4 sqmm multistranded cable and earth wire with copper conductor of size 4 sqmm for 15 amps power point complete all as specified and directed by Engineer - in Charge.
Supply and fix piano switch flush button single pole one way 5 Amps complete all as specified and directed by Engineer-in- Charge
Supply and fix piano socket 2 in 1, 2/3 pin 6 Amp flush type 250 volts AC complete all as specified and directed by Engineer -in Charge
Supply and fix piano socket 2 in 1, 3 pin 5 Amp and 15 Amp flush type 240 volts AC complete all as specified and directed by Engineer -in Charge
Supply and fix piano switch 15 Amp flush type 240 volts AC complete all as specified and directed by Engineer -in Charge
S&F LED light fitting 1x20W, 230 V integral sleek polycarbonateLED Composite batten PVC, not less than 100 luman/Watt acrylic cover incl making connection complete all as specified and directed by Engineer -in Charge
S&F ceiling rose surface bakelite two to three terminals/plate 5 amp complete all as specified and directed by Engineer -in Charge
S&F sheet metal enclosures DB single pole and neutral for 230 Volts AC supply 6 way with 200 Amps rated busbar concealed mounting double door complete all as specified and directed by Engineer -in Charge
S&F vertical MCB DB distribution box 3 phase TPN 4 ways double door as and including MCCB 125 Amp 16 KA , 415 volts as incommer with bus bar rating 200 Amps vertical type dust and vermin proof complete all as specified and directed by Engineer -in Charge
S&F MCB single pole 240 Volt 6-32 amps 10 KA complete all as specified and directed by Engineer -in Charge
S&F MCB SPN 240 Volts 32 Amp 10 KA complete all as specified and directed by Engineer -in Charge
M & L for Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers complete including earthing pit, chemical compound, earthing lead up to 7.5 mtr, 20 mm dia medium grade GI watering pipe, GI protection pipe 40mm dia eath pit in PCC 1:2:4 type B-1 using 20 mm graded stone agggragate RCC pit cover including earth work complete all as shown Electrical Plate No - 5 of SSR-2009 (Part-I). Note : The unit rate shall include for excavation & earth work in any type of soil/strata, PCC 1:2:4 type B-I for pit & RCC 1:2:4 type B-I for cover with 8mm dia CTD Bar @150mm C/C both way, funnel with watering pipe 20 mm dia medium grade, 15mm dia light grade GI pipe up to 7.5 mtr long wiremesh complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in and including PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6 Sqmm & one run of 6 Sqmm & one run of PVC conduit with accessories shall be measured as one length.
M&L Exhaust/fresh air fan 300mm sweep, 240V, 50 Hz, Polycarbonate body in window, ventilator, wall (including providing square hole and making good surfaces with louvers including grouting with fasteners, nuts/bolts etc complete all as specified and directed by Engineer-in- Charge
supply and laying or fixing or passing through pipe in repairs, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated 16 sqmm 4 core nominal cross section alumiium stranded conductor in service connection complete all as specified and directed by Engineer-in- Charge
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
GOYAL ENTERPRISES
M/s Tarun Traders
Aggarwal brothers and company
J K ENGINEERS
PAREEK AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .