Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.0 LAccepted-AOC 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | L1 | Accepted-AOC ACCEPT | |
| 2 | L2₹97.6 L+₹11.4 L (13.2%)Rejected-Finance 01 DUDWAN KUPWARA DUDWAN KUPWARA JAMMU KASHMIR 193222 UDYAM JK 12 0031214 | KUPWARA | JAMMU AND KASHMIR | 193222 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹97.8 L+₹11.5 L (13.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹98.8 L+₹12.6 L (14.6%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹1.2 Cr+₹34.2 L (39.6%)Rejected-Finance BANPURA BATWARA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
11 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SRINAGAR
CWE AF SRINAGAR
IMPROVEMENT TO CERTAIN SMQs AT AF STATION SRINAGAR PHASE-II
2023_MES_630287_1
CWE(AF)SGR/SGR-34/2023-24
Open Tender
Civil Works
Item Rate
180 days
AF STN SRINAGAR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE AF SRINAGAR
₹2.0 L
Yes
19 Mar 2024
29 Nov 2023
13 Jan 2024
29 Nov 2023
11 Jan 2024
28 Dec 2023
Amount
BUILDING
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) n exc. 1.5 sqm and credited to the contractor all as specified and directed by Engineer-in-Charge Note: The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but n exc 4 Sqm each and credited to the contractor all as specified and directed by Engineer-in-Charge Note: The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface.
Taking down shutters of any description size of shutter exc 1 sqm but n.exc 2 sqm and removing from site complete all as specified and directed.
Supply and fixing for 125x60mm size of pressed steel frame for door with one or more rebates including necessary fixing lugs, lock striking plates, hinges, hold fast (40x3mm) etc. complete size /profile of frame as per IS complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing for 105x60mm size of pressed steel frame for door with one or more rebates including necessary fixing lugs, lock striking plates, hinges, hold fast (40x3mm) etc. complete size /profile of frame as per IScomplete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in back filling of pressed steel frame etc complete all as specified and directed.
Material and labour for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to new steel surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and as directed.
Material and labour for applying one coat of synthetic enamal paint on steel surface of any description over 10cm widht or girth including preparation of old painted surfaces complete all as specified and as directed.
Supply and fixing for Factory made 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, in second class hardwood, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Factory made 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated in second class hardwood, complete all as specified and directed by Engineer-in-Charge.
Material and labour for two coats of synthetic enamel paint over a coat of pink primer to new wooden surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and as directed.
Supply and fixing in repair 18mm thick plywood,grage BWR, type BB, fixed wih screws to timber frame woork, asin kitchen drawers, cupboard shutters etc.
Supply and fixing for 0.90 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions.
Supply and fixing for 30mm width of flaps Continuous (piano) hinges, Stainless steel, bright finish or electrogalvanised, Complete all as specified and directed by Engineer-in-Charge.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel heaving a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet fore tip rail, lock rail & bottom rail on either side and as gap insert fir top rail, lock on either side and as gap insert fir tip rail & bottom raill, paneling of plain colour PVC sheet to be filled in MS frame welded/sealed to the stiles and rails with suitable PVC shet beading and jointing together with solvent cement, supplying & fixing of frame at site all as directed.
Supply and fixing for Aluminium alloy, anodised, sliding door bolt 300mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 150 mm long Aluminium anodised,handle of extruded section fabricated type anodised and fixed complete all as specified and directed.
Supply and fixing for Aluminium, anodised, barrel tower bolts 150mm size of extruded section, complete all as specified and directed by Engineer-in-Charge.
Supply & Fix 125 mm long Aluminium anodised,handle of extruded section fabricated type anodised and fixed complete all as specified and directed.
Supply and fixing for Aluminium, anodised, barrel tower bolts 125mm size of extruded section, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Butt hinges, medium weight, cold rolled mild steel 100mm size, complete all as specified and directed by Engineer-in-Charge.
Floor door stopper of aluminium alloy body 140mm cover plate and tounge, anodised with harde drawn steel spring fixed in floor, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for door strip comprising of aluminium holds & rubber strip fixed at bottom of door shutter with screws, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for Powder Coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for powder coated of any colour (Thickness or powder coating not less than 50 micron) aluminium window and ventilator shutters, side hung type without sash bars/ Sliding windows, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified.
Supply and fixing for sheet glass 4mm thick, ordinary quality and glazing with oil putty, wooden beads and aluminium beading in square or rectangular in section n exc 0.5 sq.m in each pane complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.
Supply and fixing for Figured Glass pin head type 4mm thick n exc 0.5 Sqm and glazing with oil putty, Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
Material and labour for Anodised aluminium snap grid frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specifiedcomplete all as specified and directed by Engineer-in-Charge.
Material and labour for 08 mm thick Non asbestos fibre cement building boards one side aluminium foil coated fixed or laid/ inserted to aluminium frame work with screws including taking down complete all as specified.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Pre- painted (In camouflage pattern) galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Supply and fixing for Pre-painted (In camouflage pattern) galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Supply and fixing for mild Steel ordinary rat tail rod pattern springs including roller and roller plate complete 300mm length, complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for, Complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for fair finished surface; not exceeding 200m thick (Horizontal or sloping), complete all as specified and directed by Engineer-in-Charge.
Material and labour for RCC, Type B1 1:2:4 (20 mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
MS TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooking for columns, hooking ends and binding with and including mils steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Hasp & Staple, 125 size, safety type aluminium anodised with mild steel hinge pin including bolt, to hinge plate and fixed with screws, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for in repair drapory rod 25mm dia fency type mild steel plastic coated inculding wooden funnel and wooden brackets, Complete all as specified and directed by Engineer-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors aprons etc laid in cement mortar of any thicknes, complete all as specified and directed by Engineer-in-Charge.
Material and labour for granite (of any type) work (table rubbed and polished) 20mm thick as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cm 1:4, complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour for Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6.
Material and labour for Coloured Glazed ceramic tiles in vertical surface 450X300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as backing coat.
Material and labour for for machine cut kota stone slab flooring 20-25 mm thick over screed bed or bedding layer 20 mm thick in CM 1:6, and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing & polishing complete all as specified and directed.
Material and labour for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as per item 13014 including backing coat 10mm thick in CM 1:4 .
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. Complete all as specified and directed by Engineer-in-Charge.
Material and labour for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, except brick all as specified and directed by Engineer-in-Charge.
Material and labour for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, Complete all as specified and directed by Engineer-in-Charge.
Material and labour for brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 Complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 5 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing new plastered surfaces and applying two coats of distemper oil emulsion including Thin layer (1mm thick) of wall care putty and priming coat preparatory to distempering on surfaces of wall, , complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing of new surface of plaster and applying three coats of white wash on ceiling.
Material and labour for Preparing of new surface of wall and applying two coats of cement base paint over one coat of primer.
Taking up or down steel water tubing 15mm bore and connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for GI tubes 15 mm bore 'medium grade' with all fittings and fixed complete to walls and ceilings or laid in trenches or cutting chases in wall and making good to disturbed portion of wall complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing and connection complete 20 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Steel water tubing galvenised 20mm bore medium grade with all fittings and fixed to walls, ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
Refixing old GI tubing and connections, 20 mm dia, in old or new position. (Walls, ceiling, floors, etc.) completed all as specified and directed.
Material and labour for Lagging to pipes 15mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25mm gauge 20mm mesh complete all as specified and directed by Engineer-in-Charge.
Material and labour for Lagging to pipes 20mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25mm gauge 20mm mesh complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs vitreous china ware wash hand basin white flat back, size 550x400 mm including brackets complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.Make: Cera/Prayag.
Supply and fixing in repair PVC waste pipe flexible for WHB of 32mm size complete all as specified and directed by Engineer-in-Charge. Make: Cera/Prayag.
S & F in repair, Vitreous china squating pan, orissa pattern size 580 x 440mm and making good, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc., including trap set in and including concrete Complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC valveless, syphonic action type, flushing cistern (Twin fush type), low level 10 ltr capacity, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm .
Supply and fixing in repair, Kitchen plate rack made of stainless steel 1 mm thick with plugs washers as overall size of 75cm x 75 cm including fixing to wall and all assessaries Complete all as specified and directed by Engineer-in-Charge Make: Neelkantha/Jaina
Supply and fixing in repairs 15 mm bib tap CP, cast copper alloy with capstain head screwed down screwed for iron pipe or for brass ferrule fancy type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs CP angle/stop valve of cast copper alloy screwed down high pressure with capstain head screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and directed by Engineer-in-Charge. Make: Cera/Prayag/Jaquar
Supply and fixing in repairs CP shower roses with CP Arms, 15mm bore, complete all as specified and directed by Engineer-in-Charge. Make: Cera/Prayag/Jaquar
Shelf of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleates (minimum weight300gms)
Supply and fixing Brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
Supply and fixing in repairs 15mm dia Brass CP wall mixer for mixing hot & cold water fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15mm dia Brass CP Sink mixer (wall mounted) for mixing hot & cold water complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15mm dia Brass CP central hole basin mixer with 450mm braided connection pipe (without pop-up) for mixing hot & cold water, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs Soap dish, brass CP any type, fixed to plugs with chromium plated brass screws Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs, PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints laid in trenches, floors or fixed to wall, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs, PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints laid in trenches, floors or fixed to wall complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore dia PVC floor trap(SWR) plain with grating including jointing with solvent cement to waste pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore PVC(SWR) door bends any radius complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 110 mm bore PVC(SWR) door bends any radius provided with access door complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 110mm bore PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 110mm bore PVC (SWR) 'P’ trap complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore PVC (SWR) vent cowl, complete all as specified and directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment of walls and applying thin layer of wall care putty and prepare the smooth surface with sand paper and applying two coats of distemper oil emulsion (OBD) paint on walls complete all as specified and as directed by Engineer-in-Charge
Material and labour for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (plastered or unplastered surfaces) and applying two coats of white (lime) wash complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 500 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks and removing from site including 20 mm Ball brass valves, high pressure, with polythene float and flynut complete.
Material and labour for Complete removal of existing treatment from brick walls or concrete surfaces including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or un plastered surfaces) and applying two coat of cement based paint over a coat of primer including preparation of surfaces on walls as specified and directed.
Dismantling Framed timber scantling, 40 Sqcm and over in section in any position including rafters and purlins, wooden planks
Material and labour for Second Class hard wood and scantling timber framed and fixed wrought
Dismantling boarding, any description, fixed in any position with nails in existing wooden slab complete all as spercifed.
Material and labour for Second class hard wood clean sawn planks,width n exc. 20 cm and 40mm thick fixed in existing wooden slab complete all as spercifed.
Material and labour for Filler coat with grey filler or liquid wood filler, transparent, and bringing gringing of existing wooden surfaces to smooth even finish complete all as specified and directed by Engineer in Charge
Material and labour for French polishing on surfaces of any description,width or girth including cleaning and preparing the surface including a coat of wood filler on new wooden works surfaces with two or more coats finish complete all as specified and directed by Engineer in Charge
Material and labour for French polishing on surfaces of any description,width or girth including cleaning and preparing the surface including a coat of wood filler but one or more coats on old wooden work surface complete all as specified and directed by Engineer in Charge
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, Complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded aggregate) as in pavement/plinth protection,plinth protection shall be laid in alternate bays and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen mixed with 3 part of sand) finishing surface even and smooth without extra cement complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY
Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point including fixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces as per existing complete all as specified and directed.
M & L for Concealed Point wiring for one light/fan/Exhausr fan controlled by one switch on Independent board with 1.5 sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded copper cable confirming to IS:694(2010) using approved colour code for phase and neutral as per IS code drawn through non metallic PVC rigid concealed conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked) including conduit accessories like bends, tees, junction boxes etc with all accessories suitable for modular/conventional type fitment,provision for fixing of modular flush boxes of appropriate size and dimensions for fixing of piano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 1.5 sqmm multi stranded copper conductor cable (green color) as continous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engr-in-Charge. Note: (i) For concealed point wiring cutting chases for conduit shall be measured and paid seperately (ii) For sinking boxes cutting chases for conduit shall be measured and paid seperately.
Description all as per ser item No 02 but for one light point controlled by two 2 way switches on independent board complete all as specified and directed.
Description all as per item No 02 above bit for One bell /Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent
Description all as per ser item No 02 but for 05 amp socket outlets point controlled by one switch on Independent board complete all as specified and directed.
Description all as per ser item No 02 but for 05 amp socket outlets point controlled by one switch on same board with other switches complete all as specified and directed.
Description all as per ser item No 02 but for 15 amp socket outlets point controlled by one switch on Independent socket outlet using 2.5sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded copper cable confirming to IS:694(2010) using approved colour code for phase and neutral as per IS code drawn through non metallic PVC rigid surface conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked) including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories suitable for modular type fitment,provision for fixing of modular flush boxes of appropriate size and dimensions for fixing of piano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 2.5 sqmm multi stranded copper conductor cable (green color) as continous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engr-in-Charge.
M & L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-charge
Description all as per item no.08 above for exc 10 cm but not exc 20 cm girth complete all as specified and directed by Engr-in-charge
M & L for Point wiring for one light/fan controlled by one switch on Independent board with 1.5 sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded copper cable confirming to IS:694(2010) using approved colour code for phase and neutral as per IS code drawn through PVC casing capping of suitable size in accordance with IS:14927 (Part II) having wall thickness not less than 1.2 mm thick and minimum 20x12 mm (WxH) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked) including accessories like bends, tees, junction boxes etc with all accessories suitable for modular type fitment,provision for fixing of modular flush boxes of appropriate size and dimensions for fixing of piano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 1.5 sqmm multi stranded copper conductor cable (green color) as continous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engr-in-Charge. Note: (i) For sinking boxes cutting chases shall be measured and paid seperately
Description all as per ser item No 10 but for one light point controlled by two 2 way switches on independent board complete all as specified and directed.
Description all as per item No 10 above bit for One bell /Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent
Description all as per ser item No 10 but for 05 amp socket outlets point controlled by one switch on Independent board complete all as specified and directed.
Description all as per ser item No 10 but for 05 amp socket outlets point controlled by one switch on same board with other switches complete all as specified and directed.
Description all as per ser item No 10 but for 15 amp socket outlets point controlled by one switch on Independent socket outlet using 2.5sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded copper cable confirming to IS:694(2010) using approved colour code for phase and neutral as per IS code drawn through PVC casing capping of suitable size in accordance with IS:14927 (Part II) having wall thickness not less than 1.2 mm thick and minimum size 20x12 mm (WxH) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked) including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories suitable for modular type fitment,provision for fixing of modular flush boxes of appropriate size and dimensions for fixing of piano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 2.5 sqmm multi stranded copper conductor cable (green color) as continous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engr-in-Charge.
M & L for module cover plate with frame as per site requirement for following module (a) 1 module
(b) 2 module
(b) 3 module
(d) 4 module
(e) 8 module
M & L for Modular metal Flush box as per site requirement. (a) 1/2 module
(b) 3 module
(b) 4 module
(d) 6 module
M & L for modular switch 1 way 6 Amp,230 volts ,1 Module complete all as specified and as directed by Engr-in-charge.
M & L for modular switch 2 way 6 Amp,230 volts, 1 Module complete all as specified and as directed by Engr-in-charge.
M & L for Modular Switch 1 way 16/20 Amp,230 volts, 1 Module complete all as specified and as directed by Engr-in-charge.
M &L for Modular Socket 6A, 230 volts, 2/3 Pin universal 2 module complete all as specified and as directed by Engr-in-charge.
M &L for Modular Socket 16A, 230 volts, 2/3 Pin combined 2 module complete all as specified and as directed by Engr-in-charge.
M &L for Modular fan step regulator 100 watt 2 module complete all as specified and as directed by Engr-in-charge.
M & L for Modular Bell push 6A, 230 volts, 1 way, 1 Module , complete all as specified and as directed by Engr-in-charge.
S&F Ceiling rose, surface bakelite 65 x 50 mm, 3 terminals fixed on PVC Round Block, complete all as specified and directed by Engr-in-Charge.
Supply and fix bell electric AC,230V, single phase ,ding dong type complete all as specified and as directed including connecting complete
Supply and fix Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete.
Supply and fix LED lamp 5 watt cap ,450 lumen complete all as specified and directed
S&F energy efficient LED integrated batten type luminaires suitable for wall or ceiling mounting with built in LED Chip & integral LED driver 20 watt,Aluminium channel housing & Polycarbonate diffuser of length 1200 mm (approx.),Color temperature 6500 K or as directed,Luminaire efficacy not less 100 lm/W with all accessories, fixing arrangement internally pre-wired, making all connection using 1.5 sqmm copper conductor multistarnd PVC insulated cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5 sqmm copper conductor multistarnd PVC insulated cable from ceiling rose to fitting drawn through PVC flexible conduit complete all as specified and directed.
Supply and fixing LED Bulk Head type with high out put , 10 watt ,220 V AC,Color temperature 6500 K or as directed,Lumens 1000 lm with all accessories ,IP 65 protection dust and water resistant ,surge protection up to 2.5kV, PC opal high efficiency diffuser ,LM 80 tested made die cast aluminium housing with complete assembly, suitable for surface/wall mounted with driver holder including connecting up using 1.5 sqmm copper conductor multistarnd PVC insulated cable of suitable size complete all as specified and directed.
M &L for Disconnecting all water and electric connections of geysers and taking down carefully installed storage type electric geysers of any capacity of any make/type/size (horizontal/vertical) lowering and place at site , examine the parts including preparing inventory for each geyser separately in presence of Engineer-in-Charge and cleaning and de-scaling of deposited material from inner tank, outer tank and heating elements by HCL or aqua clear pedilite solution,checking electrical connection for thermostat and indicator lamp, repair to minor leaking by soldering/brazing of the inner copper tank if noticed and and painting of geyser of any capacity after scraping, cleaning, knotting and stopping including preparation of surface of geyser and rubbing with emery paper for painting with one coat of duco paint by spray painting of approved make first quality and re write MES No. on the body of geyser with black synthetic enamel paint (letters and figures 2cm high ) &reassembling and re-fixing of geyser in its original location including hoisting, connecting to water & electric connection and testing for proper functioning of geysers including earthing to the entire satisfaction of the Engineer-in-Charge
Supply only Fiber reinforced PVC nylon pipe heavy duty size 450 mm long 15mm bore with brass coupling chromium plated with rubber washers as both ends as per IS complete all as specified.
M & L taking down carefully ceiling fan any type, sweep and make for overhauling including dismantling of blades frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts complete all as specified and as directed by Engr-in-charge.
M & L for Hanging only ceiling fan (M.D. supply) incl replacement of rubber real insulator,split pin,nut,bolt, washer and connecting up including provision of cable 3 core flexible from ceiling rose or connector to fan complete all as specified and as directed.
M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and marking MES No. with black paint complete all as specified and as directed by Engr-in-charge.
Supply and fixing ceiling fan complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with servioce value 6.00 BEE. Five star rated with brushless direct current motor and as directed by Engr-in-charge
M & L taking down carefully Exhaust fan 300mm sweep, or overhauling including dismantling of blades frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts complete all as specified and as directed by Engr-in-charge. complete all as specified and directed .
M & L for Fixing only exhaust fan (M.D.supply) and connecting up including provision of cable 3 core flexible from ceiling rose or connector to fan complete all as specified and as directed.
S&F of Exhaust fan 250mm sweep, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding, including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose, including outside louvers with proper hole, and necessary fixing arrangment and making good to disturbed surface complete all as specified and directed .
S&F LED Street Light fitting 35 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt,PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and as directed by Engr-in-charge.
Supply & Fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 50mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified and as directed by Engr-in-charge.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size 200 amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification
M & L for distribution board (DB), double door type, as per IEC 61439-3 made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 4 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 125 Amps, 16KA, 2 neutral bar and 2 earth bar IP 54 protection,cable ties for cable management(Fully insulated busbar and shrouded neutral bars),reversible door for IP 43 & IP 54 ,flush mounted to wall complete all as specified and directed. Note : Rates are inclusive for flush(Concealed ) mounting of DB and MCCB 160Amp TPN is included under respected items.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 40-63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed. Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
M&L Sub main wiring using PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded copper cable confirming to IS:694(2010) using approved colour code for phase and neutral as per IS code drawn through non metallic PVC rigid conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and external dia as under but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked) including conduit accessories like bends, tees, junction boxes etc with all accessories complete all as specified and as directed by Engr-in-charge of the following sizes of cables as under . (a) Using two single core PVC insulated FRLSH cable 4.0 sqmm copper conductor multi stranded ( Phase and neutral) and 4.0 sqmm copper conductor PVC insulated FRLSH cable as earth wire drawing in and including concealed PVC conduit not less than 2.00 mm thick ,25 mm outer dia (ISI marked) with all accessories Note :2 runs of 4.0 sqmm copper cable & 1 run of 4.0 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit
(b) Using two single core PVC insulated FRLSH cable 6 sqmm copper conductor multi stranded ( Phase and neutral) and 6 sqmm copper conductor PVC insulated FRLSH cable as earth wire drawing in and including concealed PVC conduit not less than 2.00 mm thick ,25 mm outer dia (ISI marked) with all accessories Note :2 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit
ROAD/PATH
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, Complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in hard standing/pavings/plinth protections, finished even and smooth without using extra cement, Complete all as specified and directed by Engineer-in-Charge.
Material and labour for Providing, cement concrete Type B-0 1:2:4 (12.5mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed, complete all as specified and directed by Engineer-in-Charge
Material and labour for sand filling under interlocking paver block including watering and cosolidation, complete all as specified and directed by Engr-in-Charge.
Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment, complete all as specified and directed by Engineer-in-Charge
EXTERNAL WATER SUPPLY
Excavation in trenches in soft loose soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed.
Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
Disconnecting and taking up or down old unserviceable 15 mm bore GI tubing from trenches / wall including fittings etc complete all as specified and directed.
All as per Item No 4 above but 20 mm bore GI tubing
All as per Item No 4 above but 50 mm bore GI tubing
Supply laying, jointing and testing 15 mm bore tubes, 'medium grade', galvanised, with all fitting, such as bends, elbows, tees, short pieces, connectors, unions etc and laid in trenches complete all as specified. Note :- (i) Excavation & earthwork will be measured & paid separately under appropriate item. (ii) All fittings required for laying / fixing shall be brought by the contractor and cost there of shall deemed to be included in the quoted rates.
All as per Item No 11 above but 20 mm bore GI tubing
All as per Item No 11 above but 50 mm bore GI tubing
M&L for Refixing/relaying of 15 mm bore old steel tubing and connections in new or old position, laid in trenches after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrieved from item No 4 above). Note :- (i) Excavation & earthwork will be measured & paid separately under appropriate item. (ii) All fittings required for laying / fixing shall be brought by the contractor and cost there of shall deemed to be included in the quoted rates.
All as per Item No 10 above but 20 mm bore GI tubing (using old steel tubing retrieved from item No 05 above).
All as per Item No 10 above but 50 mm bore GI tubing (using old steel tubing retrieved from item No 06 above).
M&L for Lagging to pipes 15 mm bore used in external water supply or plumbing all around with 50 mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge 20 mm mesh complete including taking down of old lagging all as specified and directed by Engineer-in-Charge
M&L for Lagging to pipes 20 mm bore used in external water supply or plumbing all around with 50 mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge 20 mm mesh complete including taking down of old lagging all as specified and directed by Engineer-in-Charge
S&F gun metal/bronze gate valve for 20 mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed.
S&F gun metal/bronze gate valve for 50mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed.
EXTERNAL ELECTRIFICATION
M & L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting it out in soft/loose soil including forming bottom surface to required level for laying of cables/pipes/poles complete all as specified and as ditrected.
M&L for returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm deep as in soil complete as specified
M&L for removing the excavated material n.exc 50M to a distance and depositing where directed at a level n.exc 1.5 M above the starting point.
M&L for sand cushioning to underground cable with dry sand locally available 8cm thick before laying of the cable and 15cm thick after laying and strectching the cable below the bricks/PCC cover, punning of sand using suitable T&P as per site condition, complete all as specified and as directed by Engr-in-Charge. Note : Punned thickness of sand to be consider for measurement purpose.
Supply and laying un-reinforced pre cast concrete cable cover confirming to IS:5820 with minimum average breaking load capacity 200 kgs for unreinforced covers , class LV Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Engr-in-Charge.
S & F GI pipe light grade 40 mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos(Flat iron 50x6mm) with ,nuts and bolts for fixing on pole complete all as specified and as directed.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 4 core 25sqmm confirming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge.
M & L for taking out old unsv LT cable of size 25 sqmm 4 core and placed at site for replacement complete all as specified and as directed.
SEWAGE DISPOSAL
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil, complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone / boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Demolition of Precast cast RCC manhole cover of any descreption set in Cement mortar including removal of debries, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description in any position complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster of any description on brick or stone wall / ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up 150 mm dia bore salt glazed stone were drain pipe including PCC packing under hunching against the sides of pipe bed and complete PCC bedding and removal of debries all specified and directed.
Supply and fixing 150 mm bore, HDPE Double Wall Corrugated Pipe in any length with rubber ring joints, laid in trenches for sewage pipe complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Concrete bed to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:3:6 (Nominal mix) type C-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
Material and labour for cutting & removing 150 / 200 mm dia drain pipe from existing manhole and inserting new drain pipe of dia 150 / 200 mm, making good disturbed surface & benching with cement concrete 1:2:4 type B-1, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
All as per item No 20 above here-in-before but except bricks. Note:- Old brick retrieved vide item No 04 above shall be reused.
Material and labour for Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching /coping and the like including weathering, slightly rounded or chamfered angles as directed including form work and finishing all exposed surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labourfor Rendering 15 mm thick on brick masonary wall surfaces in cement mortar 1:4, finished even and smooth without using extra cement including mixing only intergral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound of approved manufacturer complete all as specified and directed by Engineer-in-Charge.
Material and labour for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls and set in cement mortar 1:4 complete, complete all as specified and directed by Engineer-in-Charge. Note:- Reinforcement steel will be measured & paid separately
Material and labour for TMT steel bars 8 mm to 10 mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia all as specified. Complete all as specified and directed by Engineer-in-Charge.
AREA DRAINAGE
Excavation in trenches n. exc.1.5mtr deep for foundation manholels etc. and getting out in soft/loose soil complete and all as directed by Engr -in-Charge.
Material and labour for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation,filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6
Material and labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in surface chanel and drain finished even and smooth as directed complete.
Material and labour for PCC type B-1 1:2:4 (using 20mm graded stone aggregate ) as in coping etc all as specified.
Material and labour for rendring 15mm thick in CM (1:4) on fair faces of brick/ Concrete surface finished fair and even complete all as speciefied and directed by Engr-in-Charge .
Removing excavated material n exc 50m depositing where directed at a level exc 1.5m above the stating point all as directed by Engr in Charge .
Returning, filling of soft/loose soil in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
M/S WANI AND SONS
M/S BASHIR AHMAD TANTARY
M/S RATHER CONSTRUCTION CO
M/S SUHEEL CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .