Loading…
Loading…
Tender ID
Tender Value
₹3.5 L
EMD Value
₹3,500
Closing Date
13 Apr 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER EDC-BAGHPAT
Fault Location pin point work under EDD-I Baraut
2026_PVVNL_1125131_2
57/2025-26/EDC-BPT
Open Tender
Electrical Works
Lump-sum
EDD-I BARAUT
as per tender doucments
2 documents required · 2 mandatory
₹1,180
Yes
SUPERINTENDING ENGINEER
₹3,500
Yes
12 Jun 2026
6 Apr 2026
13 Apr 2026
6 Apr 2026
13 Apr 2026
6 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | To locate the 33 KV and 11KV fault & digging of trench with the help of road cutter/digging machine/tractor etc. (ideal size of trench 4 m length & 1.5 m width) & Road restoration after rectification of fault as per Norms. | 15 | Nos. | - | - |
| 2 | Providing, fixing and commissioning of 33 KV Straight through Box with jointer per 33KV Cable joint for filling and complete connection/work in all respect. (33 KV 3x300/400/185 Sq.mm./as per site requirement straight through box of Raychem/3M/ Denson make shall be provided by the contractor). | 3 | Nos. | - | - |
| 3 | Providing, fixing and commissioning of 33 KV Outdoor/Indoor Termination Jointing Kit with jointer per 33 KV Cable joint for filling and complete connection/work in all respect. (33 KV 3x300/400/185 Sq.mm./as per site requirement Outdoor/Indoor jointing Kit of Raychem/ 3M/ Denson make shall be provided by the contractor). | 4 | Nos. | - | - |
| 4 | Providing, fixing and commissioning of 11 KV Straight through box with jointer per 11KV Cable joint for filling and complete connection/work in all respect. (11 KV 3x185/240/300/120 Sq.mm./as per site requirement straight through box of Raychem/ 3M/ Denson make shall be provided by the contractor). | 3 | Nos. | - | - |
| 5 | Providing, fixing and commissioning of 11 KV Outdoor/Indoor Termination Jointing Kit with jointer per 11 KV Cable joint for filling and complete connection/work in all respect. (11 KV 3x185/240/300/120 Sq.mm./as per site requirement Outdoor/Indoor Termination jointing Kit of Raychem/ 3M/ Denson make shall be provided by the contractor). | 5 | Nos. | - | - |
| 6 | Providing Experienced jointer per 33 KV and 11 KV joint for filling of 33 KV and 11KV straight through box and complete work in all respect as per Norms. (33 KV and 11KV 3x300/400/185/120 Sq.mm./As per Site Requirement straight through box shall be provided by the department). Carriage of above Straight Through Box from any store of PVVNL Discom to work site in the scope of Contractor. | 3 | Nos. | - | - |
| 7 | Providing Experienced jointer per 33 KV and 11 KVjoint for filling of 33 KV and 11KV Indoor/Outdoor Termination Kit and complete work in all respect as per Norms. (33 KV and 11KV 3x300/400/185/120 Sq.mm./As per Site Requirement Termination Kits shall be provided by the department). Carriage of above Straight Through Box from any store of PVVNL Discom to work site in the scope of Contractor. | 5 | Nos. | - | - |
| 8 | Replacement of 33KV and 11KV damaged cable (approx 5 Mtrs. in each case) and Laying and proper commissioning of cable in trench after making joint and filling of sand/brick/soil as per site requirement.
(cable shall be provided by the department). | 15 | Nos. | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.14 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.58 MB
T_C2.pdf
Tender Documents • 1.46 MB
BOQ_2116262.xls
BOQ • 0.28 MB
57DateExt.pdf
PDF • 0.53 MB
dateextension57.pdf
PDF • 0.47 MB
57dateextension.pdf
PDF • 0.16 MB
ext57.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .