Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-Finance 9 C 8 SECTOR 07 ROHINI NEW DELHI 110085 | NEW DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-Finance The Quoted Amount is inclusive of Taxes as per NABI MOHALI. | |
| 2 | L2₹4.5 L+₹22,067.18 (5.11%)Accepted-Finance MOHALI PUNJAB 140308 | S A S NAGAR | PUNJAB | 140308 | L2 | Accepted-Finance The Quoted Amount is inclusive of Taxes as per NABI MOHALI. | |
| 3 | L3₹4.6 L+₹23,339.22 (5.40%)Accepted-Finance Y 51 GF OKHLA INDUSTRIAL AREA PHASE II DELHI 110020 | DELHI | SOUTH DELHI | DELHI | 110020 | L3 | Accepted-Finance The Quoted Amount is inclusive of Taxes as per NABI MOHALI. | |
| 4 | L4₹4.6 L+₹24,143.98 (5.59%)Accepted-Finance | L4 | Accepted-Finance The Quoted Amount is inclusive of Taxes as per NABI MOHALI. | |
| 5 | L5₹5.3 L+₹99,948.01 (23.1%)Accepted-Finance SCO 47 2ND FLOOR SECTOR 11 134109 | PANCHKULA | HARYANA | 134109 | L5 | Accepted-Finance The Quoted Amount is inclusive of Taxes as per NABI MOHALI. |
Tender Value
Refer Docs
EMD Value
₹9,241
Closing Date
19 Jul 2019, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MANAGER - ADMIN
KNOWLEDGE CITY SECTOR 81 MOHALI
SITC of Gas Supression System
2019_NABI_484037_1
NABI/7(190)/2019-WORKS
Open Tender
Electrical Works
Item Rate
42 days
NABI CAMPUS
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
NABI
₹9,241
Yes
9 Dec 2020
8 Jul 2019
22 Jul 2019
8 Jul 2019
19 Jul 2019
8 Jul 2019
120 days
Supply, Installation, Testing & Commissioning of NOVEC 1230 Gas CCOE approved cylinder assembly of 67.5/80ltr. capacity complete with valve, pressure gauge, syphon tube etc. as per the approved technical specifications and site requirement. The System should be pressurized at 42 bar with Dry Nitrogen.
Supply and filling of NOVEC 1230 clean agent Gas in the cylinder as per the approved technical specifications and site requirement
Supply, Installation, Testing & Commissioning of UL/ EN /VDS approved Electrical Solenoid actuator-24V DC, Local Manual Actuator, Discharge Hose, Manifold Check valve, Supervisory pressure switch and all other allied accessories complete as per the approved technical specifications and site requirement
Supply and Fixing of 80ltrs. capacity cylinder mounting bracket with clamps, bolts, fastener etc. complete as per the approved technical specifications and site requirement
Supply and Fixing of MS seamless pipe of suitable size with necessary fittings and accessories etc. complete as per the approved technical specifications and site requirement
Supply, Installation, Testing & Commissioning of NOVEC 1230 Clean agent gas Brass discharge nozzles of suitable size and 360deg. NPT complete as per the approved technical specifications and site requirement
Supply and fixing of UL/ EN / VDS approved Gas release push button unit to release the gas manually as per the approved technical specifications and site requirement
Supply and fixing of UL/ EN / VDS approved Gas Inhibit push button unit to abort gas release and to shift system from auto to manual as per the approved technical specifications and site requirement
Supply and fixing of Smoke/Heat/Multi detector with base and hardware for mounting complete as per the approved technical specifications and site requirement
Supply and Fixing of UL/ EN / VDS approved Electronic hooters complete as per the approved technical specifications and site requirement
Supplying, laying, testing and commissioning of following sizes of Low Smoke Zero Halogen Silicon Insulated Fire Survival Cable with Drain Wire, solid copper conducter cable approved by LPCB as per BSEN 50200:2015 PH 120 (Fire, Mech Shock & Water 120 Minutes @ 830 deg Celcius, Fire & Mech Shock every 5 Min for 2 Hours- Both test conducted on same sample) and BS-6387 CWZ The cable shall sustain 950 deg. C. For 3 hours approved . The cable shall be BS EN 60332-1-2:2004 for Bunched Flame Retardancy (installed as a single or bunched cable self extinguishes leaving the upper cable sheath unaffected showing the cable does not propagate fire). Cable shall be guaranteed for 10 years from the date of manufacture marked on the cable.(Size : 2C X 1.5sqmm)
Supply, Installation, Testing & Commissioning of Microprocessor based 02 zone fire alarm control panel with LCD display and inbuilt functions for fire detection, fire alarming, gas release, gas inhibit function with SMF battery and battery charger etc. complete as per the site requirement
Supply of Warning plates, caution sign boards etc. complete as per the site requirement
Fair Deal Engineers
M/S ADVENT ELECTRIC TECHNOLOGIES PVT LTD
S.S. CONSULTANTS
Damia Global Services Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .