Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LQualified A 42 JAI AMBEY NAGAR TONK ROAD JAIPUR RAJASTHAN 302018 | JAIPUR | RAJASTHAN | 302018 | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹33.8 L+₹3,960 (0.12%)Qualified NO 121 6 SATHANUR MAIN ROAD SATHANUR BANGALORE KARNATAKA 560064 | BENGALURU URBAN | KARNATAKA | 560064 | L2 | Qualified MSE, MII, Category: General | |
| 3 | L3₹45.2 L+₹11.5 L (34.0%)Qualified | L3 | Qualified MSE, MII, Category: General | |
| 4 | Disqualified 21B FIRST FLOOR SHYAM NAGAR BEHIND CHANDIWALA NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | - | Disqualified MII | |
| 5 | Disqualified RZ 15B BLOCK A ROSHAN VIHAR PHASE 2ND NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | - | Disqualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
19 Feb 2026, 4:00 pmClosed
C23640002987 SITC of 3 phase
30 KVA UPS along with 1 set for each UPS
sealed maintenance free batteries
12V 100AH - Refer si no 1 of Table no 3 page no 8 of ANNEXURE- III
100000000001 SITC of following size of unsheathed flexible four core multi-strand copper cable with copper lugs
Brass compression glands - Refer si no 2 of Table no 3 page no 8 of ANNEXURE- III
100000000002 SITC of 25X5 mm electrolytic grade Copper Earth strip with insulation sleeves complete in all respect for connections etc. as required- Refer si no 3 of Table no 3 page 8 ANNEXURE- III
100000000006 Comprehensive AMC charges for 1 years for 02 no 30 kva UPS- Refer si no 1 of Table no 4 page no 9 of ANNEXURE-IV
100000000007 Comprehensive AMC charges for 2 years for 04 no 30 kva UPS- Refer si no 2 of Table no 4 page no 9 of ANNEXURE-IV
100000000008 Comprehensive AMC charges for 2 years for 04 no 30 kva UPS- Refer si no 3 of Table no 4 page no 9 of ANNEXURE-IV
100000000009 Comprehensive AMC charges for 4 years for 04 no 30 kva UPS- Refer si no 4 of Table no 4 page no 9 ANNEXURE-IV
100000000010 Comprehensive AMC charges for 5 years for 04 no 30 kva UPS- Refer si no 5 of Table no 4 page no 9 ANNEXURE-IV
8955377
GEM/2026/B/7212125
Two Packet Bid
C23640002987 SITC of 3 phase, 30 KVA UPS along with 1 set for each UPS, sealed maintenance free bat
Uttar Pradesh; Ghaziabad, Uttar Pradesh; Ghaziabad; Ghaziabad
Total value wise evaluation
BOQ
1 document required · 1 mandatory
GHAZIABAD, GAD CENTRAL, Department of Defence Production, Bharat Electronics Limited (BEL), Ministry of Defence, (Bharat Electronics Limited)
Exempted
Yes
21 Mar 2026
9 Feb 2026
19 Feb 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | C23640002987 SITC of 3 phase, 30 KVA UPS along with 1 set for each UPS, sealed maintenance free batteries, 12V 100AH - Refer si no 1 of Table no 3 page no 8 of ANNEXURE- III | SITC of 3 phase UPS 10KVA along with 1 set for each UPS sealed maintenance free batteries 12V 42AH - Refer si no 1 of Table no 3 page no 8 of ANNEXURE- III | 4 | NO | con5.bel.gzb | 90 |
| 2 | 100000000001 SITC of following size of unsheathed flexible four core multi-strand copper cable with copper lugs, Brass compression glands - Refer si no 2 of Table no 3 page no 8 of ANNEXURE- III | SITC of following size of unsheathed flexible four core multistrand copper cable with copper lugs Brass compression glands - Refer si no 2 of Table no 3 page no 8 of ANNEXURE- III | 200 | MTR | con5.bel.gzb | 90 |
| 3 | 100000000002 SITC of 25X5 mm electrolytic grade Copper Earth strip with insulation sleeves complete in all respect for connections etc. as required- Refer si no 3 of Table no 3 page 8 ANNEXURE- III | SITC of 25X5 mm electrolytic grade Copper Earth strip with insulation sleeves complete in all respect for connections etc. as required.- Refer si no 3 of Table no 3 page 8 ANNEXURE- III | 200 | MTR | con5.bel.gzb | 90 |
| 4 | 100000000006 Comprehensive AMC charges for 1 years for 02 no 30 kva UPS- Refer si no 1 of Table no 4 page no 9 of ANNEXURE-IV | Comprehensive AMC charges for 1 years for 02 no 30 kva UPS- Refer si no 1 of Table no 4 page no 9 of ANNEXURE-IV | 1 | NO | con5.bel.gzb | 90 |
| 5 | 100000000007 Comprehensive AMC charges for 2 years for 04 no 30 kva UPS- Refer si no 2 of Table no 4 page no 9 of ANNEXURE-IV | Comprehensive AMC charges for 2 years for 04 no 30 kva UPS- Refer si no 2 of Table no 4 page no 9 of ANNEXURE-IV | 1 | NO | con5.bel.gzb | 90 |
| 6 | 100000000008 Comprehensive AMC charges for 2 years for 04 no 30 kva UPS- Refer si no 3 of Table no 4 page no 9 of ANNEXURE-IV | Comprehensive Comprehensive AMC charges for 2 years for 04 no 30 kva UPS- Refer si no 3 of Table no 4 page no 9 of ANNEXURE-IV | 1 | NO | con5.bel.gzb | 90 |
| 7 | 100000000009 Comprehensive AMC charges for 4 years for 04 no 30 kva UPS- Refer si no 4 of Table no 4 page no 9 ANNEXURE-IV | Comprehensive AMC charges for 4 years for 04 no 30 kva UPS- Refer si no 4 of Table no 4 page no 9 ANNEXURE-IV | 1 | NO | con5.bel.gzb | 90 |
| 8 | 100000000010 Comprehensive AMC charges for 5 years for 04 no 30 kva UPS- Refer si no 5 of Table no 4 page no 9 ANNEXURE-IV | Comprehensive Comprehensive AMC charges for 5 years for 04 no 30 kva UPS- Refer si no 5 of Table no 4 page no 9 ANNEXURE-IV | 1 | NO | con5.bel.gzb | 90 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8955377.pdf
GEM_BID
30kvaupsts_2026-02-09-14-52-32_3ea67d91522c976162f29dcc922de5e2.pdf
BOQ
boq_item_sample_file_20260209084335501_x_2026-02-09-14-52-32_15eacb0a7a4776bfb1b6364e3a11cbc3.csv
BOQ
30KVAUPSTS_184fa073-9ff7-4da3-b5291770629208647_buyer6.bel.gzb.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .