Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 CrAccepted-AOC | ₹9.9 Cr Quoted ₹8.7 Cr | L1 | Accepted-AOC LOWEST TENDERER |
| 2 | L2₹9.2 CrRejected-AOC NO 93 KADAL THOTTAM VADAPALANI KUMARAPALAYAM POST NATHAKADAIYUR VIA ERODE 638 108 | ERODE | TAMIL NADU | 638108 | ₹9.2 Cr | L2 | Rejected-AOC SECOND LOWEST TENDERER |
| 3 | L3₹9.5 CrRejected-AOC SAKTHI MAHAL NO 63 PERUNDURAI ROAD ERODE 638 011 | ERODE | TAMIL NADU | 638011 | ₹9.5 Cr | L3 | Rejected-AOC THIRD LOWEST TENDERER |
| Sl No | Description | Qty | Unit | kadal constructions L2 | R R THULASI BUILDERS INDIA P LTD L3 | KARTHIKEYAN ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00Cat (A) -Items to be supply and installation | ||||||
| 1.01 | SCHEDULE – A - Enhancement of existing Transformer by "providing 500KVA Trasformer inculding all allied works and electrification in TNCSC MRM campus" at Manamadurai in Sivagangai District.
Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100Vgrade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with MS switch box in flush with wall with 5AFT switch with 3mm thick hylem sheet cover MS switch box with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion for concealed light point / fan point (for electronic regulator) etc, Complete complying with Standard Specification and as directed. | 11 | POINTS | 5,100 ₹56,100 | 5,110 ₹56,210 | 5,000 ₹55,000 |
| 1.02 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed. | 2 | POINTS | 2,500 ₹5,000 | 2,510 ₹5,020 | 2,500 ₹5,000 |
| 1.03 | Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed. | 1 | RM | 3,050 ₹3,050 | 3,060 ₹3,060 | 3,000 ₹3,000 |
| 1.04 | Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed. | 2 | NOS | 1,200 ₹2,400 | 1,220 ₹2,440 | 1,080 ₹2,160 |
| 1.05 | supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed. | 1 | NO | 2,700 ₹2,700 | 2,750 ₹2,750 | 2,700 ₹2,700 |
| 1.06 | supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed. | 6 | NOS | 6,150 ₹36,900 | 6,200 ₹37,200 | 6,100 ₹36,600 |
| 1.07 | Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed. | 2 | NOS | 2,500 ₹5,000 | 2,550 ₹5,100 | 2,470 ₹4,940 |
| 1.08 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed. | 1 | NO | 5,100 ₹5,100 | 5,120 ₹5,120 | 5,050 ₹5,050 |
| 1.09 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed. | 10 | NOS | 3,150 ₹31,500 | 3,180 ₹31,800 | 3,100 ₹31,000 |
Tender Value
Refer Docs
EMD Value
₹5.1 L
Closing Date
29 Dec 2025, 2:00 pmClosed
MANAGING DIRECTOR
Head Office, Koyambedu, Chennai-107
Enhancement of existing Transformers by Providing 500KVA Transformer incl all ectrification in TNCSC MRM at Manamadurai, Kadachanendhal, Adavathur, Ammanpettai, Sundarakottai, Thimmavaram, Thirukovilur, ThirunageswarErukkur1,2, Pattukottai and Polur.
2025_TCSC_631898_1
40/CE/DB/DOE/077715/2025
Open Tender
Electrical Works
365 days
THANJAVUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹5.1 L
20 Feb 2026
15 Dec 2025
30 Dec 2025
15 Dec 2025
29 Dec 2025
15 Dec 2025
Cat (A) -Items to be supply and installation
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Supply and Laying of 3. Runs of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Runs of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Runs of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 2 runs of 3½ x 400 sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Repairing and supply of fixing RCC road cross machine cutting in cable trench 18"x9"thikness removing and refilling in site RCC works good condition etc, Complete complying with Standard Specification and as directed.
Supply and laying of 3 1/2 x 240 sq.mm PVC aluminum armored LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 240 sq.mm. aluminum armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and Clamping of 3 Core 4 Sqmm LTUG copper cable on post or on wall with MS Clamp etc, Complete complying with Standard Specification and as directed.
POINTS
Supply, erection, testing & Commissioning of 500 kVA, 22 kV / 433 V Outdoor Oil Cooled Transformer with On load tap changer suitable HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, etc. (As per IS-Level 1) Losses PWD XIII PART "M"1- TRANSFORMERS/ S NO; B. distribution transformer confirming to relevant Is continuously rated for full load with neutral brought out on secondary sid with first filling of oil inculding the accessories such as conservator tank ,tap changer drain out let , sillca gel breather,thermometer pocket earthing and earthing terminals ,name plate,fillte valve ,lifting hook, oil level gauge, air reease device, oil filling hole, explosion,yent, inspection cover ect. with HT/LT busing box suitable for providing 3 runs of 31/2x400Sq mm LTUG aluminium cable on secondary side all removable covers shall be provided with wether proof hot oil resistant,resistance gaskets to prevent leakage of water in to core and oilfrom the tank with low no load loss. providing stopper block at the bottam with necessary test certificate and connection to earth pipes as per IE rule and regulation and with secification suitable for parallel operation in the future and loading and un loading charges including. (Make - Kirloskar, Crompton Greaves, Voltech) etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed .
Supply, and fixing of Installation , Testing and Commissioning of sheet steel clad dust and vermin proof of Cubicle type, Indoor type, floor mounting, free standing, extendible type Main 1. 630A TPN SWITCH MAIN - 1 No 2. 400A TPN SWITCH MAIN- 3 Nos 3. 250A TPN SWITCH MAIN - 6 Nos BUS BAR RATING : ONE SET COPPER BUS BAR with colour with DME ,SME bus bar supports and suitable earth bus (0.8 Alu) PH: 200Amps,. NOTE: All MCCB's and HRC fuse cubical DP type shall have rotary handle Mechanism and spreader wherever necessary. and cable entry Top/Bottom etc, Complete complying with Standard Specification and as directed.
Supply and erection of 800A ACB on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed.
Rectification of 22 KV 2 pole structure with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 22KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as per I.E rules and CEIG rules and a) 1 sets 22KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 22KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 22 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rules) 1Set of 3Nos 22 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
e Entries .Each Gate is Fabricated using 2" Gi Pipe as Outer Frame with Weld Mesh with Necessary Support. Earthing the fencing by using No 8 SWG Copper Wire all Around the Fencing etc, Complete complying with Standard Specification and as directed.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
Supply and erection of 250A TPN Main on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Removal of the Worn out Cables, Old Panel Boards, and Condemn Materials such as Pvc Pipes, GI Clamps,Old Light Fittings, lugs, Glands and with 1No 30Years old Transformers of 200KVA/250KVA/315KVA.We Quote our best price below. The rate includes cost of Loading, Unloading and Transport to take materials to outside the premises in TNCSC MRM campus" at Erukkur phase -2 in Mayiladuthurai District.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Dismantling of Existing 315KVA rated transformer & shifted to designated location, Body Earth flats & Neutral flats from Existing 315KVA rated transformer, and termination of 11 KV(E) HT XLPE 3 x 185 sq.mm Al. Ar. cable - indoor Joint kit, Fence & gate, Control cable & its terminations,315KVA Transformer Body Earth Electrode,315KVA Transformer outgoing LT cable termination, Excavation & backfilling for remove the HT & LT Cable inside the factory premises etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3. Runs of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3. Runs of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and laying of 3 1/2 x 240 sq.mm PVC aluminum armored LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 240 sq.mm. aluminum armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Repairing and supply of fixing RCC road cross machine cutting in cable trench 18"x9"thikness removing and refilling in site RCC works good condition etc, Complete complying with Standard Specification and as directed.
Supply and Clamping of 3 Core 4 Sqmm LTUG copper cable on post or on wall with MS Clamp etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. aluminum armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and erection of 630A MCCB on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed .
Dismantling, Supply, erection, testing & Commissioning of 500 kVA, 11kV / 433 V Outdoor Oil Cooled Transformer with On load tap changer suitable HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, etc. (As per IS-Level 1) Losses PWD XIII PART "M"1- TRANSFORMERS/ S NO; B. distribution transformer confirming to relevant Is continuously rated for full load with neutral brought out on secondary sid with first filling of oil inculding the accessories such as conservator tank ,tap changer drain out let , sillca gel breather,thermometer pocket earthing and earthing terminals ,name plate,fillte valve ,lifting hook, oil level gauge, air reease device, oil filling hole, explosion,yent, inspection cover ect. with HT/LT busing box suitable for providing 2 runs of 31/2x400Sq mm LTUG aluminium cable on secondary side all removable covers shall be provided with wether proof hot oil resistant,resistance gaskets to prevent leakage of water in to core and oilfrom the tank with low no load loss. providing stopper block at the bottam with necessary test certificate and connection to earth pipes as per IE rule and regulation and with secification suitable for parallel operation in the future and loading and un loading charges including (Make - Kirloskar, Crompton Greaves, Voltech), etc, Complete complying with Standard Specification and as directed.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
Towards Charges for Trench Excavation of 450mm with 1000 mm depth for HT cable Laying and re filling with M.sand height of 150mm protection for bedding above 11 KV UG cables with cover slab RCC size 30"x120'' etc, Complete complying with Standard Specification and as directed
uides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure etc., complete with colour coding.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Towards Charges for Trench Excavation of 450mm with 1000 mm depth for HT cable Laying and re filling with M.sand height of 150mm protection for bedding above 11 KV UG cables with cover slab RCC size 30"x120'' etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Supply and Laying of 3. Runs of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Danger Board as required by the Electrical Authorities
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Runs of 3-1/2 x 240sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 240 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Runs of 3-1/2 x 150 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 2 runs of 3½ x 150 sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Runs of 3-1/2 x 150sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Repairing and supply of fixing RCC road cross machine cutting in cable trench 18"x9"thikness removing and refilling in site RCC works good condition etc, Complete complying with Standard Specification and as directed.
Supply and Clamping of 3 Core 4 Sqmm LTUG copper cable on post or on wall with MS Clamp etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 150 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed .
Supply and providing cable end termination of 3-1/2 x 150 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and erection of 4Way 7 Segment 3 Phase DB with 100A FP Isolator as incoming 3 Nos. 40A Double Pole RCCB and 12 Nos. 6 A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed .
Renewal by Supply and Fixing of 250A TPN in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
uides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure etc., complete with colour coding.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation.
Supply and Laying of 3. Runs of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3. Runs of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3-1/2 x 400sq.mm sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Supply and Laying of 3-1/2 x 240sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3Core 4 sq.mm armored LTUG Copper cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed .
Design, supply, erection of 150 KVAR, 8 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with su
pply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalized out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming- DPX 800A FP MCCB with rotary handle. Outgoing: 8 stage capacitor bank Contactors: Bharatia Cuttler Hammer/L&T Heavy Duty contactors. Relays: World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 8 stage from 1 KVAR to 150 KVAR 1.stage-5KVAR 2.stage-10KVAR 3.stage-15KVAR 4.stage-20KVAR 5.stage-25X2KVAR 6.stage-25x2KVAR BUS BAR 2 runs of 52mmx6mm tinned copper Metering: 1-500A Ammeter with CT coil 2) 0- 500V voltmeter 3) Advance micro controller based intelligent power factor controller with self diagnostic sensing and digital net work analyses with software for monitory and saving para meter of a suitable multi function meter.Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection etc, Complete complying with Standard Specification and as directed.
Supply and erection of 12Way 7 Segment 3 Phase DB with 100A FP Isolator as incoming 3 Nos. 40A Double Pole RCCB and 36 Nos. 6 A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection etc, Complete complying with Standard Specification and as directed.
Supply, and fixing of Installation , Testing and Commissioning of sheet steel clad dust and vermin proof 1. 400A TPN SWITCH MAIN- 1 No. 2. 250A TPN SWITCH MAIN- 3 Nos.3. 200A TPN SWITCH MAIN- 1 No. 4. 120A TPN SWITCH MAIN- 4 Nos. BUS BAR RATING : ONE SET COPPER BUS BAR with colour with DME, SME bus bar supports and suitable earth bus (0.8 Alu) PH: 200Amps. NOTE: All MCCB's and HRC fuse cubical DP type shall have rotary handle Mechanism and sepreader wherever neccssary. and cable entry Top/Bottom etc, Complete complying with Standard Specification and as directed.
Supply, and fixing of Installation , Testing and Commissioning of sheet steel clad dust and vermin proof 1. 250A TPN SWITCH MAIN- 1 No. 2. 100A TPN SWITCH MAIN-3 Nos. 3. 63A TPN SWITCH MAIN- 2No. BUS BAR RATING : ONE SET COPPER BUS BAR with colour with DME, SME bus bar supports and suitable earth bus (0.8 Alu) PH: 200Amps,. NOTE: All MCCB's and HRC fuse cubical DP type shall have rotary handle Mechanism and sepreader wherever neccssary. and cable entry Top/Bottom etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation.
Renewal by Supply and Fixing of 250A TPN in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3. Runs of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Supply and Laying of 3-1/2 x 240sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3Core 4 sq.mm armored LTUG Copper cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed .
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 150 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Repairing and supply of fixing RCC road cros machine cutting in cable trench 18"x9"thik ness removing and refilling in site RCC works good condition etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed .
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
Design, supply, erection of 150 KVAR, 8 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalized out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming- DPX 800A FP MCCB with rotary handle. Outgoing: 8 stage capacitor bank Contactors: Bharatia Cuttler Hammer/L&T Heavy Dut
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3Core 4 sq.mm armored LTUG Copper cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and erection of 800A ACB on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed .
Supply and erection of 250A TPN Main on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed .
Supply and Laying of 2. Run of 3-1/2 x 240sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 2. Run of 3-1/2 x 240 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Run of 3-1/2 x 240 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 240 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Supply and clamping of 3-1/2 x 400sq.mm sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3-1/2 x 95 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Comple
Supply and clamping of 3Core 4 sq.mm armored LTUG Copper cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
te complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 150 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Design, supply, erection of 150 KVAR, 8 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalized out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming- DPX 800A FP MCCB with rotary handle. Outgoing: 8 stage capacitor bank Contactors: Bharatia Cuttler Hammer/L&T Heavy Duty contactors. Relays: World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 8 stage from 1 KVAR to 150 KVAR 1.stage-5KVAR 2.stage-10KVAR 3.stage-15KVAR 4.stage-20KVAR 5.stage-25X2KVAR 6.stage-25x2KVAR BUS BAR 2 runs of 52mmx6mm tinned copper Metering: 1-500A Ammeter with CT coil 2) 0- 500V voltmeter 3) Advance micro controller based intelligent power factor controller with self diagnostic sensing and digital net work analyses with software for monitory and saving para meter of a suitable multi function meter.Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed .
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet. iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
y contactors. Relays: World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 8 stage from 1 KVAR to 150 KVAR 1.stage-5KVAR 2.stage-10KVAR 3.stage-15KVAR 4.stage-20KVAR 5.stage-25X2KVAR 6.stage-25x2KVAR BUS BAR 2 runs of 52mmx6mm tinned copper Metering: 1-500A Ammeter with CT coil 2) 0- 500V voltmeter 3) Advance micro controller based intelligent power factor controller with self diagnostic sensing and digital net work analyses with software for monitory and saving para meter of a suitable multi function meter. Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection etc, Complete complying with Standard Specification and as directed.
uides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure etc., complete with colour coding.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3Core 4 sq.mm armored LTUG Copper cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Run of 3-1/2 x 240sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Supply and clamping of 3-1/2 x 400sq.mm sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply, erection, testing & Commissioning of 500 kVA, 22 kV / 433 V Outdoor Oil Cooled Transformer with On load tap changer suitable HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, etc. (As per IS-Level 1) Losses PWD XIII PART "M"1- TRANSFORMERS/ S NO; B. distribution transformer confirming to relevant Is continuously rated for full load with neutral brought out on secondary sid with first filling of oil inculding the accessories such as conservator tank ,tap changer drain out let , sillca gel breather,thermometer pocket earthing and earthing terminals ,name plate,fillte valve ,lifting hook, oil level gauge, air reease device, oil filling hole, explosion,yent, inspection cover ect. with HT/LT busing box suitable for providing 3 runs of 31/2x400Sq mm LTUG aluminium cable on secondary side all removable covers shall be provided with wether proof hot oil resistant,resistance gaskets to prevent leakage of water in to core and oilfrom the tank with low no load loss. providing stopper block at the bottam with necessary test certificate and connection to earth pipes as per IE rule and regulation and with secification suitable for parallel operation in the future and loading and un loading charges including. (Make - Kirloskar, Crompton Greaves, Voltech) etc, Complete complying with Standard Specification and as directed.
Supply and erection of 8Way 7 Segment 3 Phase DB with 100A FP Isolator as incoming 3 Nos. 40A Double Pole RCCB and 24 Nos. 6 A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Fixing of 250A TPN in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed .
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Renewal by Supply and fixing of 400 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with PWD Earthing etc, Complete complying with Standard Specification and as directed .
Supply and erection of 250A TPN Main on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
Supply, erection, testing & Commissioning of 500 kVA, 11kV / 433 V Outdoor Oil Cooled Transformer with On load tap changer suitable HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, etc. (As per IS-Level 1) Losses PWD XIII PART "M"1- TRANSFORMERS/ S NO; B. distribution transformer confirming to relevant Is continuously rated for full load with neutral brought out on secondary sid with first filling of oil inculding the accessories such as conservator tank ,tap changer drain out let , sillca gel breather,thermometer pocket earthing and earthing terminals ,name plate,fillte valve ,lifting hook, oil level gauge, air reease device, oil filling hole, explosion,yent, inspection cover ect. with HT/LT busing box suitable for providing 2 runs of 31/2x400Sq mm LTUG aluminium cable on secondary side all removable covers shall be provided with wether proof hot oil resistant,resistance gaskets to prevent leakage of water in to core and oilfrom the tank with low no load loss. providing stopper block at the bottam with necessary test certificate and connection to earth pipes as per IE rule and regulation and with secification suitable for parallel operation in the future and loading and un loading charges including (Make - Kirloskar, Crompton Greaves, Voltech), etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Draw out type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos,
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Run of 3-1/2 x 240sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet. iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed.
Rectification of 22 KV 2 pole structure with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 22KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat each as per engineer in charge with supply and erection of following HT accessories as per I.E rules and CEIG rules and a) 1 sets 22KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 22KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 22 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 22 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary Connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Design, supply, erection of 150 KVAR, 8 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalized out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming- DPX 800A FP MCCB with rotary handle. Outgoing: 8 stage capacitor bank Contactors: Bharatia Cuttler Hammer/L&T Heavy Duty contactors. Relays: World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 8 stage from 1 KVAR to 150 KVAR 1.stage-5KVAR 2.stage-10KVAR 3.stage-15KVAR 4.stage-20KVAR 5.stage-25X2KVAR 6.stage-25x2KVAR BUS BAR 2 runs of 52mmx6mm tinned copper Metering: 1-500A Ammeter with CT coil 2) 0- 500V voltmeter 3) Advance micro controller based intelligent power factor controller with self diagnostic sensing and digital net work analyses with software for monitory and saving para meter of a suitable multi function meter. Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection etc, Complete complying with Standard Specification and as directed.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 150 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3. Runs of 3-1/2 x 400 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed .
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Renewal by Supply and fixing of 400 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with PWD Earthing etc, Complete complying with Standard Specification and as directed .
Supply and Laying of 3. Runs of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable in suitable size 4” dia class HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
SCHEDULE – A - Enhancement of existing Transformer by "providing 500KVA Trasformer inculding all allied works and electrification in TNCSC MRM campus" at Manamadurai in Sivagangai District. Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100Vgrade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with MS switch box in flush with wall with 5AFT switch with 3mm thick hylem sheet cover MS switch box with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion for concealed light point / fan point (for electronic regulator) etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Repairing and supply of fixing RCC road cros machine cutting in cable trench 18"x9"thik ness removing and refilling in site RCC works good condition etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and erection of 800A ACB on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed
Supply and clamping of 2. Run of 3-1/2 x 240 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 2. Run of 3-1/2 x 240 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 240 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Supply and clamping of 3-1/2 x 400sq.mm sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3-1/2 x 95 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Comple
Supply and Laying of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet. iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
SCHEDULE – B - Enhancement of existing Transformer by "providing 500KVA Transformer including all allied works and electrification in TNCSC MRM campus" at Kadachanendal in Madurai District. Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100Vgrade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with MS switch box in flush with wall with 5AFT switch with 3mm thick hylem sheet cover MS switch box with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion for concealed light point / fan point (for electronic regulator) etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Supply and clamping of 3-1/2 x 400 sq.mm armored LTUG PVC Aluminum cable on post or on wall with
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and fixing of Higher end Philips / Havells make or Eq single box type 4feet-20 W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20 W LED tube with PVC unsheathed copper leads from terminals to the fitting etc, Complete complying with Standard Specification and as directed.
MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
ification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Supply and clamping of 3-1/2 x 400sq.mm sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3-1/2 x 95 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Comple
Supply and Laying of 3. Run of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3-1/2 x 400 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed .
Renewal by Supply and fixing of 400 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with PWD Earthing etc, Complete complying with Standard Specification and as directed .
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
SCHEDULE – C - Enhancement of existing Transformer by "providing 500KVA Transformer including all allied works and electrification in TNCSC MRM campus" at Adavathur in Thanjavur District. Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100Vgrade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with MS switch box in flush with wall with 5AFT switch with 3mm thick hylem sheet cover MS switch box with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion for concealed light point / fan point (for electronic regulator) etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Supply and clamping of 3-1/2 x 400 sq.mm armored LTUG PVC Aluminum cable on post or on wall with
Supply and Laying of 3-1/2 x 240 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 185 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Supply and clamping of 3-1/2 x 400sq.mm sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3-1/2 x 95 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Comple
Renewal by Supply and Fixing of 630A TPN Switch in the Existing Panel Board with Copper Bus fair Inter Connection Earth Connection with Suitable adopter Boxes etc, Complete complying with Standard Specification and as directed .
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet. iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Drawing approval and safety certificate from CEIG officer i) Part A. Drawing approval ii) Preparation of following documents iii) Site plan iv) Substation layout v) Physical layout of Machinery - 1 vi) Physical layout of Machinery - 2 vii) Electrical schematic diagram viii) Submission of drawings to CEIG office ix) Co-ordination with CEIG officials x) Obtaining drawing approval from CEIG office xi) Part: B Arranging inspection and safety certificate xii) Submission of completion report xiii) Arranging R-63 inspection by CEIG/EI xiv) Getting defects report xv) Submission of rectification report xvi) obtaining safety certificate from CEIG office xvii) drawing approval & completion report signing charges. xviii) Liaisoning with the chief Electrical Inspector to government of Tamilnadu for issue of safety certification approval for energisation
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
SCHEDULE – D - Enhancement of existing Transformer by "providing 500KVA Transformer including all allied works and electrification in TNCSC MRM campus" at Ammanpettai in Thanjavur District. Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100Vgrade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with MS switch box in flush with wall with 5AFT switch with 3mm thick hylem sheet cover MS switch box w
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion for concealed power plug point etc, Complete complying with Standard Specification and as directed.
Repair of Power room in /out and of Transformer plinth with suitable construction work with painting etc, Complete complying with Standard Specification and as directed.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp etc, Complete complying with Standard Specification and as directed.
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete with necessary wall opening and making of the wall etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc, Complete complying with Standard Specification and as directed.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc, Complete complying with Standard Specification and as directed.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
Dismantling of Existing 315KVA rated transformer & shifted to designated location, Body Earth flats & Neutral flats from Existing 315KVA rated transformer, and termination of 11 KV(E) HT XLPE 3 x 185 sq.mm Al. Ar. cable - indoor Joint kit, Fence & gate, Control cable & its terminations,315KVA Transformer Body Earth Electrode,315KVA Transformer outgoing LT cable termination, Excavation & backfilling for remove the HT & LT Cable inside the factory premises etc, Complete complying with Standard Specification and as directed.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection etc, Complete complying with Standard Specification and as directed.
AC Chargeable Emergency Lamp 2x11W Pl Lamp with all connected accessories etc, Complete complying with Standard Specification and as directed.
Supply and laying of 11KV insulation confirming to IS 6 mm thick marked rubber of size 2000 mm x 1000 mm in front of the LT Panel Boards .(5Nos one set) etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts, nuts etc. the extinguisher shall be suitable for all types of fire(A,B&C) properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of etc, Complete complying with Standard Specification and as directed.
Supply, erecting and connecting a 40x40x6 mm capacity of 3 Nos Fire Bucket painted with red oxide outside and white inside with handle hanged in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with red paint etc, Complete complying with Standard Specification and as directed.
Shock Treatment char fixed in glass frame.
Earth Discharge rod.
Supply of 11 KV Tested Gloves one set
Danger Board as required by the Electrical Authorities.
Supply and fixing of 22 KV Al Danger Boards of size 6" x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
Supply and fixing of 440V Al Danger Boards of size 6"x 4" both in Tamil and English etc, Complete complying with Standard Specification and as directed.
First Aid Kit.
Supply and clamping of 3-1/2 x 400 sq.mm armored LTUG PVC Aluminum cable on post or on wall with
Repairing and supply of fixing RCC road cros machine cutting in cable trench 18"x9"thik ness removing and refilling in site RCC works good condition etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Supply, and fixing of Installation, Testing and Commissioning of sheet steel clad dust and vermin proof of Cubicle type, Indoor type, floor mounting, free standing, extendible type Main 1. 630A TPN SWITCH MAIN - 1 No 2. 400A TPN SWITCH MAIN- 3 Nos 3. 250A TPN SWITCH MAIN - 6 Nos BUS BAR RATING : ONE SET COPPER BUS BAR with colour with DME ,SME bus bar supports and suitable earth bus (0.8 Alu) PH: 200Amps,. NOTE: All MCCB's and HRC fuse cubical DP type shall have rotary handle Mechanism and spreader wherever necessary. and cable entry Top/Bottom etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armored LTUG cable with earth connection etc, Complete complying with Standard Specification and as directed.
Supply and providing cable end termination of 3-1/2 x 240 sq.mm. PVC LTUG aluminum armored cable with necessary aluminum cable sockets by crimping etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Supply and clamping of 3-1/2 x 400sq.mm sq.mm PVC aluminum armored LTUG cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Renewal by Supply and Providing HT Yard size 6000mmx9000mm Link Fencing with fixing of 8 feet Height by MS Angle size 75mmx75mmx6mm Excavated Earth with depth of 2 ft Putting and Concrete Filling the earth to make good and Fixing of Chain Link Fencing with size of( 2 " X 2") X10SWG Galvanized iron wire all around the HT Yard with Necessary Binding Wire for Separate the EB Yard and Consumer Supply Yard Places HT Yard is Provided with 2 Gat
Supply and Laying of 3-1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3-1/2 x 95 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Comple
Supply and erection of 800A ACB on suitable angle iron frame work with adopter boxes and giving connection etc, Complete complying with Standard Specification and as directed.
Supply and clamping of 3. Run of 3-1/2 x 400 sq.mm armored LTUG PVC Aluminum cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
MAIN MV PANEL, Supply Installation, testing and commissioning of 800A incoming ACB, 440 Volt, 3 Phase, 50 HZ, 4 wire A.C system Sheet steel clad dust and vermin proof of cubicle type, indoor type floor mounting, free standing , extendible made of 2mm CRCA sheet steel for doors and covers and MS channel (75 x 40 mm) and removable Gland plate at bottom entries for cable, single bus bar system interconnections, cable chamber, powder coated painting earthling etc. EB INCOMMER, 800 Amps – 4 pole – 50 kA ACB, MDO Drawout type with Adjustable CL and SC Protection. i) . LED type RYB indication lamp with control MCBs - 1 set ii) . Digital Multi function meters with 3 Nos LED pilot lamps Earth pit Relay. iii) . Terminal Connector with MCBs – 1 set. 1. 630A TPN SWITCH MAIN - 2 Nos, 2. 400A TPN SWITCH MAIN - 2 Nos, 3. 250A TPN SWITCH MAIN - 2 Nos,4. i). Cable entry : bottom ii). Cable gland plate: 3 mm thick Al Sheet. iii). One set COPPER BUS BAR COLOUR WITH DMC/SMC INSULATION Necessary hardware and civil works related to this work all are by the scope of contractor etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Supply and Laying of 3. Run of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable through 4” Dia HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, g
Cat (B) - Buy Back Items
Supply and Laying of 3-1/2 x 240 sq.mm. PVC armoured LTUG cable in suitable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and Laying of 3-1/2 x 400 sq.mm. PVC armoured LTUG cable Suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc, Complete complying with Standard Specification and as directed.
Supply and clamping 3-1/2 x 400 sq.mm. PVC armoured cable on post or on wall with MS Clamps etc, Complete complying with Standard Specification and as directed.
Supply, and fixing of Installation , Testing and Commissioning of sheet steel clad dust and vermin proof of Cubicle type, Indoor type, floor mounting, free standing, extendible type Main 1. 630A TPN SWITCH MAIN - 1 No 2. 400A TPN SWITCH MAIN- 3 Nos 3. 250A TPN SWITCH MAIN - 6 Nos BUS BAR RATING: ONE SET COPPER BUS BAR with colour with DME ,SME bus bar supports and suitable earth bus (0.8 Alu) PH: 200Amps,. NOTE: All MCCB's and HRC fuse cubical DP type shall have rotary handle Mechanism and sepreader wherever neccssary. and cable entry Top/Bottom etc, Complete complying with Standard Specification and as directed.
Rectification of 11 KV 2 pole stucture with requisite heavy duty clamps, bolts and nuts to support the switch gears, insulators, 0 copper jumpers and accessories to receive and distribute the 11 KV 2 pole structure of consumer side and painting of all metal parts with base coat of red oxide and approved paint one coat eash as per engineer in charge with supply and erection of following HT accessories as mper I.E rules and CEIG rules and a) 1 sets 11 KV gang operated double break AB Switch complete connecting rod, operating handle, guides, etc., on 100x50 mm channel frame. b) 3 nos lighting arrestor for 11 KV system channel frame. c) 1 set(each with 3 nos) DO/HG fuse assembly on channel frame d) 6 nos Sufficient number 11 KV pin insulators with metal pars on channel frame to maintain sufficient clearance for
jumpers as per rulese) 1Set of 3Nos 11 KV strain disc insulators with Metal parts on suitable top channel 100mm x 50mm x6mm to receive the EB supply and to feed 2 Pole structure. Supply and fixing of required cross bracing made of size 50x50x6mm MS angle to keep the structure in stable condition. Providing necessary HT connection and jumper Connection from TNEB structure to consumer 2Pole structure with ACSR conductors "O" HDBC Copper conductor for giving necessary connection and jumpering from stain disc insulators, AB switch, lighting arrestor, HG fuse Through pin insulators and to transformer Bushing etc., complete with colour coding.
Dismantling of Existing 315KVA rated transformer & shifted to designated location, Body Earth flats & Neutral flats from Existing 315KVA rated transformer, and termination of 11 KV(E) HT XLPE 3 x 185 sq.mm Al. Ar. cable - indoor Joint kit, Fence & gate, Control cable & its terminations,315KVA Transformer Body Earth Electrode,315KVA Transformer outgoing LT cable termination, Excavation & backfilling for remove the HT & LT Cable inside the factory premises etc, Complete complying with Standard Specification and as directed. ONE SET COPPER BUS BAR with colour with DME ,SME bus bar supports and suitable earth bus (0.8 Alu) PH: 200Amps,. NOTE: All MCCB's and HRC fuse cubical DP type shall have rotary handle Mechanism and sepreader wherever neccssary. and cable entry Top/Bottom etc, Complete complying with Standard Specification and as directed.
Removal of the Worn out Cables, Old Panel Boards, and Condemn Materials such as Pvc Pipes, GI Clamps,Old Light Fittings, lugs, Glands and with 1No 30Years old Transformers of 200KVA/250KVA/315KVA.We Quote our best price below. The rate includes cost of Loading, Unloading and Transport to take materials to outside the premises in TNCSC MRM campus" at Manamadurai in Sivagangai District
Removal of the Worn out Cables, Old Panel Boards, and Condemn Materials such as Pvc Pipes, GI Clamps,Old Light Fittings, lugs, Glands and with 1No 30Years old Transformers of 200KVA/250KVA/315KVA.We Quote our best price below. The rate includes cost of Loading, Unloading and Transport to take materials to outside the premises in TNCSC MRM campus" at Kadachanendal in Madurai District.
Removal of the Worn out Cables, Old Panel Boards, and Condemn Materials such as Pvc Pipes, GI Clamps,Old Light Fittings, lugs, Glands and with 1No 30Years old Transformers of 200KVA/250KVA/315KVA.We Quote our best price below. The rate includes cost of Loading, Unloading and Transport to take materials to outside the premises in TNCSC MRM campus" at Adavathur in Thanjavur District.
Removal of the Worn out Cables, Old Panel Boards, and Condemn Materials such as Pvc Pipes, GI Clamps,Old Light Fittings, lugs, Glands and with 1No 30Years old Transformers of 200KVA/250KVA/315KVA.We Quote our best price below. The rate includes cost of Loading, Unloading and Transport to take materials to outside the premises in TNCSC MRM campus" at Ammanpettai in Thanjavur District.
Removal of the Worn out Cables, Old Panel Boards, and Condemn Materials such as Pvc Pipes, GI Clamps,Old Light Fittings, lugs, Glands and with 1No 30Years old Transformers of 200KVA/250KVA/315KVA.We Quote our best price below. The rate includes cost of Loading, Unloading and Transport to take materials to outside the premises in TNCSC MRM campus" at Sundarakottai in Thiruvarur District.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tendernotice_2.pdf
PDF • 1.27 MB
BOQ_755863.xls
BOQ • 1.01 MB
Download all tender documents and submit your bid