Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC 221 KHU WALI GALI GONIANA MANDI BATHINDA | BATHINDA | BATHINDA | PUNJAB | ₹1.3 Cr | 1 | Accepted-AOC ist lowest |
| 2 | 2₹1.3 CrRejected-AOC | ₹1.3 Cr | 2 | Rejected-AOC 2nd lowest |
| 3 | 3₹1.3 CrRejected-AOC 30 HOME LAND ENCLAVE BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.3 Cr | 3 | Rejected-AOC 3rd lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
3 Mar 2026, 10:00 amClosed
ER ONKAR SINGH
EXECUTIVE ENGINEER PROVL DIV PWD BR BATHINDA
CONSTRUCTION OF URBAN PRIMARY HEALTH CENTRE NEAR REHABLITATION CENTRE BATHINDA
2026_CEPW_160502_1
PB/BTI/120
Open Tender
Civil Works - Buildings
180 days
DISTT BATHINDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.8 L
Yes
13 Apr 2026
17 Feb 2026
3 Mar 2026
17 Feb 2026
3 Mar 2026
17 Feb 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: EXECUTIVE ENGINEER PROVINCIAL DIVISION, BATHINDA
NAME OF WORK:- CONSTRUCTION OF URBAN PRIMARY HEALTH CENTRE ( NON 24X7) NEAR REHABILITATION CENTRE BATHINDA (PUNJAB)
Contract No: Civil Work only
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work Name Item Code / Make Quantity Unit Rate Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. Sqm Full Conversion INR
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type cum Full Conversion INR
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth cum Full Conversion INR
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) Sqm Full Conversion INR
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth cum Full Conversion INR
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. cum Full Conversion INR
Extra Rate for First Floor cum Full Conversion INR
Extra Rate for Second Floor cum Full Conversion INR
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Centering and shuttering for columns (Square or rectangular or poly gonal in plain) Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Extra Rate for Second Floor Sqm Full Conversion INR
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Extra Rate for Second Floor Sqm Full Conversion INR
Centring and shuttering for stair cases with sloping with soffits including risers and stringers. Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Extra Rate for Second Floor Sqm Full Conversion INR
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete QTL Full Conversion INR
Extra Rate for First Floor QTL Full Conversion INR
Extra Rate for Second Floor QTL Full Conversion INR
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. Cum Full Conversion INR
Extra Rate for First Floor Cum Full Conversion INR
Extra Rate for Second Floor Cum Full Conversion INR
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
12.5 mm thick cement plaster 1:5 in two coats work. Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Extra Rate for Second Floor Sqm Full Conversion INR
20 mm thick cement plaster 1:5. Sqm Full Conversion INR
Extra rate for First Floor Sqm Full Conversion INR
Extra rate for Second Floor Sqm Full Conversion INR
12.5 mm thick cement plaster 1:4 in two coat work. Sqm Full Conversion INR
Extra rate for First Floor Sqm Full Conversion INR
Extra rate for Second Floor Sqm Full Conversion INR
20 mm thick cement plaster 1:4 in two coat work. Sqm Full Conversion INR
Extra rate for First Floor Sqm Full Conversion INR
Extra rate for Second Floor Sqm Full Conversion INR
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. Sqm Full Conversion INR
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia. rmtr Full Conversion INR
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in- charge. UPVC 110 mm bend nos Full Conversion INR
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets nos Full Conversion INR
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. nos Full Conversion INR
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating nos Full Conversion INR
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. nos Full Conversion INR
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg./Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing Sqm Full Conversion INR
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. rmtr Full Conversion INR
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead cum Full Conversion INR
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres cum Full Conversion INR
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material Sqm Full Conversion INR
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material Sqm Full Conversion INR
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects. rmtr Full Conversion INR
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) Sqm Full Conversion INR
Extra Rate for First Floor Sqm Full Conversion INR
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. Sqm Full Conversion INR
Extra labour for projected nosing of stair case of any shape and design Rmtr Full Conversion INR
Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. Sqm Full Conversion INR
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
Door and window frame of size 113mmx60mmx with 35mm wide single rebate rmtr Full Conversion INR
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. rmtr Full Conversion INR
Supplying and fixing of glass panes 4mm thick 0.599 Sqm Full Conversion INR
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer- in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) kg Full Conversion INR
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. Sqm Full Conversion INR
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4) QTL Full Conversion INR
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick Sqm Full Conversion INR
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm Sqm Full Conversion INR
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm nos Full Conversion INR
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. rmtr Full Conversion INR
Providing and fixing of 30mm thick factory made Polyvinyl Chloride (PVC) door shutter (without chowkhat) made of styles and rails of a UPVC Plug profile section of size 30mm x 60mm and wall thickness 2mm ±0.2mm with inbuilt decorative molding edging on one side. The styles and rails with plastic brackets of size 75x220mm meter and welded at the corners. The- stiles of the shutter reinforced by inserting galvanized MS tube of size 25x20mm and 1mm ± 0.1mm wall thickness. The lock rail made up of ‘H’ section, a UPVC Plug profile section of size 30mm x 100mm and 2mm±0.2mm wall thickness welded to the shutter style with a UPVC Plug profile section single panel of size not less than 620mm, having overall thickness of 20 mm and 1 mm±0.1 mm wall thickness with 20 mm panel beading of suitable size /Glass(4mm thick plain glass)/louver section, louver frame of suitable size, as per manufactures specification and direction of Engineering- charge. (For WC and bathroom door Shutter) Sqm Full Conversion INR
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish Sqm Full Conversion INR
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade Sqm Full Conversion INR
Finishingwallswith acrylic smooth exterior paint of requiredshadewithtwoormorecoats applied @ 1.67 litre/10Sqm over and including base coat of waterproofing Cement Paint applied @ 2.20 Kg/10 Sqm Sqm Full Conversion INR
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete. Sqm Full Conversion INR
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. Sqm Full Conversion INR
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. Sqm Full Conversion INR
Applying priming coat with metal primer on new steel or iron work including preparation of surface. Sqm Full Conversion INR
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre- Sqm Full Conversion INR
Construction of Plinth protection complete Full Conversion INR
Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer In-Charge. cum Full Conversion INR
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer. (10.6 b ii) cum Full Conversion INR
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 (i)) cum Full Conversion INR
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material (14.3) Sqm Full Conversion INR
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). Sqm Full Conversion INR
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. (15.10) Sqm Full Conversion INR
Electrical Services
Providing Electrical Installation
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Full Conversion INR
Wiring fan point (With fan box) Each Full Conversion INR
Wiring light point Each Full Conversion INR
Wiring call-bell point Each Full Conversion INR
Wiring 6 Amp. wall socket point Each Full Conversion INR
Wiring 6 Amp. Plug control comprising wall socket point Each Full Conversion INR
Wiring 16/20 amp. power plug control point Each Full Conversion INR
Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Full Conversion INR
Wiring Computer terminal point having 2 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered) and 2Nos. 16/20Amp. switch with indicator (Modular accessories). 9 Each Full Conversion INR
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Full Conversion INR
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 9 Each Full Conversion INR
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Full Conversion INR
Wiring Networking socket point RJ45 (one module) 9 Each Full Conversion INR
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Full Conversion INR
Overall size 1.5sq.mm (Un-sheathed) 725 Mtr Full Conversion INR
Overall size 2.5sq.mm (Un-sheathed) 710 Mtr Full Conversion INR
Overall size 4sq.mm (Un-sheathed) 270 Mtr Full Conversion INR
Overall size 6sq.mm (Un-sheathed) 50 Mtr Full Conversion INR
Overall size 10sq.mm (Un-sheathed) 40 Mtr Full Conversion INR
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Full Conversion INR
Overall size 1.5sq.mm (48/0.20mm), 3Core 100 Mtr Full Conversion INR
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Full Conversion INR
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. 30 Mtr Full Conversion INR
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Full Conversion INR
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed 460 Mtr Full Conversion INR
Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed 60 Mtr Full Conversion INR
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- Full Conversion INR
PVC flexible pipe 25mm dia. 20 Mtr Full Conversion INR
PVC flexible pipe 40mm dia. 15 Mtr Full Conversion INR
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Full Conversion INR
Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- Full Conversion INR
Ceiling Rose (Flush Piano type) 8 Each Full Conversion INR
Call Bell 220/230 volts AC Ding Dong 4 Each Full Conversion INR
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- Full Conversion INR
MCB Single Pole 6-32amp. (10kA, Curve-C) 68 Each Full Conversion INR
MCB Double Pole 40amp. (10kA, Curve-C) 10 Each Full Conversion INR
MCB Four Pole 50, 63amp. (10kA, Curve-C) 2 Each Full Conversion INR
MCB Triple Pole 50, 63amp. (10kA, Curve-C) 2 Each Full Conversion INR
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- Full Conversion INR
SP&N Double Door Distribution Board 12 way each 2 Each Full Conversion INR
TP&N Horizontal Double Door Distribution Board 8 way each 2 Each Full Conversion INR
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). Full Conversion INR
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) 6 Each Full Conversion INR
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- Full Conversion INR
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) 20 Mtr Full Conversion INR
COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Full Conversion INR
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long 2 Mtr Full Conversion INR
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- Full Conversion INR
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) 10 Mtr Full Conversion INR
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Full Conversion INR
Overall size 35sq.mm (3½ Core) Un-armoured (Loose) 70 Each Full Conversion INR
MCCB's (MOULDED CASE CIRCUIT BREAKER): Full Conversion INR
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- Full Conversion INR
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 1 Each Full Conversion INR
Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- Full Conversion INR
IC Four Pole Changeover Switch 100amp., 415volts 1 Each Full Conversion INR
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- Full Conversion INR
TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB 125amp.) 1 Each Full Conversion INR
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Full Conversion INR
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) 70 Mtr Full Conversion INR
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- Full Conversion INR
Aluminium thimble cable Core size 4 - 6sq.mm 20 nos Full Conversion INR
Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:- Full Conversion INR
Copper thimble cable Core size 4 - 6sq.mm 50 nos Full Conversion INR
Copper thimble cable Core size 10 - 16sq.mm 30 nos Full Conversion INR
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 28 Each Full Conversion INR
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 19 Each Full Conversion INR
Supply and Erection of LED surface mounted 36/40watt 1'X4' (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) serge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary 16 Each Full Conversion INR
Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. 25 Each Full Conversion INR
Supply and erection of Wall Fan Plastic Body 400MM, 16" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 3 Each Full Conversion INR
Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with aluminium louver shutter, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. 8 Each Full Conversion INR
Supply and Erection of LED Flood Light 50 Watt (including BIS certified potted single driver with screen or laser printing logo LED Driver), with pressure die cast aluminium housing with control gear (IP 65/66 protection), THD<10%, CRI Minimum 70, HIgh power LED (with wattage 1 to 5 watt), mandatory secondary lenses, toughned glass fitting,surge protection 10KV Efficacy of Led fixture minimum 120 lumens per watt, 5 years warranty including their diver complete in all respects as approved and desired by the Engineer in-charge at site. LED fittings as per specifications approved by Hon'ble Techncial Advisor to Punjab Govt. Vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufacturer should have in house NABL accredited LAB. 4 Each Full Conversion INR
Providing Networking Services Full Conversion INR
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: Full Conversion INR
Supply and erection of CAT 6 with 23 AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Full Conversion INR
CAT 6 LAN cable 360 mtr Full Conversion INR
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Full Conversion INR
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed 250 mtr Full Conversion INR
Supply, Installation, Testing & Commissioning of 16-Port Gigabit Unmanaged Switch ,10/100/1000Mbps Gigibit Ethernet ,16 ,76W ,External Input 54V 3.7A(200W) Input 54V 2.4A(130W) Input 54V 1.66A(90W) ,Metal ,Desktop, wall & rack mount ,Power, Link/Activity ,Fanless ,Yes ,Yes ,Yes ,4K ,1MB ,32Gbps ,IEEE 802.3az complaint ,2,088,514 hours ,Yes ,Yes ,1:3:5:7:8:10:12:15 Weighted Fair Queue (WFQ) ,Input 54V 1.66A (90W) External ,90W ,0 dBA (Fanless) ,0° to 40°C (32° to 104°F) ,Class A ,11.26 x 4.02 x 1.06 in ,0.88 kg (1.94 lb) ,47 CFR FCC Part 15, SubpartB, Class A ICES-003:2016 Issue 6, Class A ANSI C63.4:2014 ,55032:2012+AC:2013, Class A EN 55024:2010 EN 61000-3-2:2014, Class A EN 61000-3-3:2013 ,AS/NZS CISPR 32:2015, Class A ,VCCI-CISPR 32:2016, Class A ,CNS 13438 ,CB. IEC 60950-1:2005(ed.2) + A1:2009 + A2:2013 ,UL/cUL Listed; UL60950-1, 2nd Ed. 2014; CAN/CSA C22.2 No. 60950-1-07, 2nd Ed. 2014 ,EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 ,AS/NZS 60950.1:2015 ,Lifetime Hardware Warranty ,90 Day's Free remote configuration support ,Replacement with new box product. complete in all respects as desired by the Engineer in charge of work at site. 1 Each Full Conversion INR
SITC of CAT 6, 16 Port Fully loaded Patch Panel, Rack Mountable for cable termination complete in all respects as desired by the Engineer in charge of work at site. 1 Each Full Conversion INR
SITC of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 9 Each Full Conversion INR
SITC of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 9 Each Full Conversion INR
Supply & Erection of POE Powered Indoor Wi-Fi Access Point 1 Gbps Speed having 2.4Ghz and 5Ghz network, omni directional antenna, 01 No. Giga WAN port and, Password Protection, Wide Area Range, Ceiling /Wall Mount Flow Control, App Controlled, IEEE 802.3at PoE, Up to 100 Wi-Fi Users, Security Protocol WPA/WPA2/WPA3™ Personal/ Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control Power Supply Connect 12 V / 2.5 A (optional power adapter not included), IEEE 802.3at PoE, Support Port Forwarding, NAT Etc complete in all respects as desired by the Engineer in charge of work at site. 1 Each Full Conversion INR
SITC of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle, Power 5 W, Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital, Cash counter, Tehsil, Courts etc, Warranty 1 Year,220 VAC Operating Voltage character Capacity 3 Character, Power Consumption, Rectangular Metal body complete in all respects as desired by the Engineer in charge of work at site.. 1 Each Full Conversion INR
Supply & installation of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks complete in all respects as desired by the Engineer in charge of work at site. 1 Each Full Conversion INR
Supply, Installation, Testing & Commissionning of ExiLED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code, complete in all respects as desired by the Engineer in charge of work at site. 8 Each Full Conversion INR
Supply & installation of 1KVA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 1 Each Full Conversion INR
Suppy and Erection of RJ45 Connector complete in all respects as desired by the Engineer in charge of work at site. 1 Each Full Conversion INR
Supply, Erection, Testing and Commissioning of 3 KVA Double Conversion Online UPS System including Batteries 12V 65ah Amp hrs. True Online Pure Sine wave DSP Controlled online UPS with single phase AC input and single phase AC output with inbuilt Isolation Transformer of same OEM make at Input Including installation & 2 years warranty. Along with battery rack, interconnection cables & 5/7-meter DC wire from UPS to battery bank and other standard accessories of UPS & Battery Bank. UPS is with inbuilt Phase sequence correction & protection feature , TVSS & Cold start feature and emergency power off (EPO) feature & dust filters, manual & automatic bypass inbuilt and UPS should be capable for Parallel operation up to 4 same units with additional optional PRS kit. UPS Rating : KVA 3, Load Power Factor: PF 0.8, Efficiency: 0.9, Nominal DC Voltage: VDC 12Vx no of batteries 8, No of Batteries: 8, End Cell Voltage: 1.75x6: 10.5, DC Watts: = (KVA X 1000 X PF) / (Inv Eff X No. of batt) Watts, DC watts: UPS load DC wattage 444, Backup time: in mins 60, AH Offered: AH rating of SMF battery: 65AH, No of cells/Batteries: 1string of 8 no. of 65AH, Min VAH of bank for 60 min: 1 set of 8 no. of 12V-65AH 10080, Battery AH Wattage: 65AH battery gives Backup calculation: Backup Achieved in min = battery AH wattage x 60 Min / UPS load DC watts: 33.14 min, Backup achieved more than 60 min backup achieved: on SMF battery bank with 10080VAH on 0.8LPF for 3KVA UPS. This 3kVA double-conversion on-line 2U rackmount UPS provides pure sine wave power to support critical electronics during power disruptions, with IEC 320 C20 input, 6x IEC 320 C13 and 1x IEC 320 C19 outlets. The On-Line UPS has a intelligent card slot for optional Network Management Card that enables network-based UPS monitoring and management. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The Built-in automatic and manual bypass provide seamless power to the load even in the event of an internal detected fault or error in UPS. The UPS is compatible with replacement battery cartridge APCRBCV202. The UPS is compatible with rail kit sold separately. The UPS and the built-in lead-acid battery has a 2-year warranty. Ideal for small data centers, manufacturing facilities, computer rooms, network storage devices, telecommunication, and healthcare IT. Complete in all respects as desire by the Engineer in-charge of work at site. 1 Each Full Conversion INR
Supply, Installation, Testing & Commissionning of AgoraLED NM LED IP42 230V 2X6W 1h/3h/8h. The luminiare comes in plastic housing. Mounting bracket is not required for this luminaire, IP42/NA 0 Non -Maintained Self Testing 12V / 7Ah Pb, LED based for anti-panic area, surface assembly Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch High lumen output – 1h = 360lm / 3h = 170lm / 8h = 70lm Simple and quick assembly and maintenance Technical lifetime of LED > 100 000 hours • IP42 – dust and waterproof luminaire, Voltage 220-240VAC / 50-60Hz Power consumption 11.4W / 11.8VA Battery 12V / 7Ah Pb Battery protection Over charge protection /deep discharge protection Charging Time 23 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source LED 2x6, Technical lifetime (light source) >100 000 hours, Lumen output, emergency (1h / 3h / 8h) 3200 / 1600 / 800 lm, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IP rating IP42, Dimensions 302 x 94 x 210 mm, Weight 4200 / 4420 gr, Materials PC/ABS, PC, Aluminium, Mounting method Wall mounting complete in all respects as approved and desired by the Engineer in-charge at site. 4 Each Full Conversion INR
Public Health Services
Sub Work-1 Internal Water Supply, Sewerage, Sanitation Full Conversion INR
Sub Head-1 Internal Sewerage System Full Conversion INR
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B Full Conversion INR
110mm o/d single socket SWR UPVC pipe lines laid complete 65.24 mtr Full Conversion INR
90mm o/d SWR UPVC pipe lines laid complete 92.07 mtr Full Conversion INR
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. Full Conversion INR
For 110mm i/d pipes Full Conversion INR
Elbow 90 Degree (All side socketed) 12 each Full Conversion INR
Vent Cowls 5 each Full Conversion INR
Coupler 21 each Full Conversion INR
Single Tee With Door 5 each Full Conversion INR
For 90mm o/d pipes Full Conversion INR
Elbow 90 degree (all side socket) 4 each Full Conversion INR
Vent Cowls 4 each Full Conversion INR
Single Tee 8 each Full Conversion INR
Coupler 20 each Full Conversion INR
Single Tee With Door 4 each Full Conversion INR
P Trap/Floor Trap 110mm x 110mm 18 each Full Conversion INR
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) Full Conversion INR
110mm o/d 133 each Full Conversion INR
90mm o/d 79 each Full Conversion INR
Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge. 2 each Full Conversion INR
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. Full Conversion INR
M.S. Holder bats clamps for 100mm i/d H.C.I. pipes 15 each Full Conversion INR
M.S. Holder bats clamps for 90mm o/d as per table-1 12 each Full Conversion INR
Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge. 2 each Full Conversion INR
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. Full Conversion INR
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm as per table-1 15 each Full Conversion INR
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. Full Conversion INR
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal 14 each Full Conversion INR
Sub Head-2 Internal Water Supply System Full Conversion INR
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. Full Conversion INR
SDR 11 CPVC pipes & fittings 20mm o/d 51.81 mtr Full Conversion INR
CPVC SDR 11 Pipe & fitting 25mm o/d 91.44 mtr Full Conversion INR
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm Full Conversion INR
qty same as CPVC 16mm o/d to 40 mm 143.25 mtr Full Conversion INR
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. Full Conversion INR
Through wall 11.43 cm thick 2 each Full Conversion INR
Through wall 22.86 cm thick 8 each Full Conversion INR
Providing, fixing and jointing Upvc Union Couplings with Upvc Pipes complete in all respect. Full Conversion INR
25mm i/d CPVC Union 8 Each Full Conversion INR
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball Full Conversion INR
Brass Ball Cock with rod and Plastic Ball 25mm i/d 8 Nos Full Conversion INR
Providing, fixing and jointing Upvc Tank Nipple with Upvc Pipes complete in all respect. Full Conversion INR
25mm i/d CPVC tank nipple 12 Each Full Conversion INR
Sub Head - 3 Sanitary Installation Full Conversion INR
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 5 each Full Conversion INR
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Detail attached as per Table-3 Full Conversion INR
Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect Detail attached as per Table-3 2 Each Full Conversion INR
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut 7 each Full Conversion INR
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. 7 each Full Conversion INR
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. 2 each Full Conversion INR
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Full Conversion INR
Size 49 cm dia (above counter round) 7 each Full Conversion INR
Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 8 each Full Conversion INR
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. Full Conversion INR
Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling 1 each Full Conversion INR
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut 16 each Full Conversion INR
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. 11 each Full Conversion INR
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. Full Conversion INR
C.P brass towel ring 8 each Full Conversion INR
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. 8 each Full Conversion INR
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) 7 Nos Full Conversion INR
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. Full Conversion INR
C.P Brass bib cock foam flow without flange 8 each Full Conversion INR
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. Full Conversion INR
C.P.brass 15mm Angle valve without flange 16 each Full Conversion INR
C.P.brass 15mm Concealed stop cock with flange 7 each Full Conversion INR
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. 15 each Full Conversion INR
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long 7 each Full Conversion INR
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long 15 each Full Conversion INR
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories: Full Conversion INR
C.P. brass toilet roll holder with flap 2 Nos Full Conversion INR
Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. Full Conversion INR
35mm dia 900mm (36”) long 2 Nos Full Conversion INR
35mm dia 1200mm (48”) long 2 Nos Full Conversion INR
Foldable U Type 762mm long 2 Nos Full Conversion INR
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks 5000 ltr Full Conversion INR
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 6 pegs 2 each Full Conversion INR
Construction of Plateform complete as per specification & as desired by Enginer-in-charge Full Conversion INR
For 2000 ltr Water Tank 2 Nos Full Conversion INR
For 1000 ltr Water Tank 1 Nos Full Conversion INR
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. 18 Nos Full Conversion INR
Sub Head-4 Flooring and Wall Tile Full Conversion INR
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material 21.79 Sqm. Full Conversion INR
Screed of 50mm thick cement concrete 1:8:16 with stone aggregateto be laid below the topping using mechanical mixer for mixing of material Full Conversion INR
Total First Floor 234.44 sqm Full Conversion INR
Extra rate for First Floor 21.78 sqm Full Conversion INR
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . Full Conversion INR
Total all Floors 43.57 sqm Full Conversion INR
Extra rate for First Floor 21.78 sqm Full Conversion INR
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm). 21.78 sqm Full Conversion INR
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Full Conversion INR
Total all Floors 145.38 sqm Full Conversion INR
Extra rate for First Floor 69.26 sqm Full Conversion INR
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. 6.62 sqm Full Conversion INR
Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means 3.4856 cum Full Conversion INR
Sub Head -5 Water Cooler & Air Conditioning Full Conversion INR
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Full Conversion INR
Water Cooler Full Steel Body 150/150 ltr without Stablizer Detail as per Table-3 1 Each Full Conversion INR
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge) including carriage and fixing in position complete in all respect. 1 Each Full Conversion INR
Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Full Conversion INR
Automatic Voltage Stablizer 2 KVA For Drinking Water Cooler 1 Each Full Conversion INR
Supplying,errection, testing & commissioning of split type air-conditioners Rating four star rating Cap.1.50 TR confirming to IS:1391 (Part-2)-1992 with amendments No.1& 2 fitted with Rotary compressor operating on Refrigerant R-32 suitable for wall mounting of reputed make such as Carrier/Toshiba/Diakin/Mitsubishi or equivalent make with 4.00 KVA voltage stablizer, MCB arrangement & installing OD units on terrace/as per site requirement including inlet and outlet copper tubes with proper insulation,drainage arrangement,cable link between ID unit and OD units,MS stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 3 Each Full Conversion INR
Supplying,errection, testing & commissioning of split type air-conditioners Rating four star rating Cap.1.0 TR confirming to IS:1391 (Part-2)-1992 with amendments No.1& 2 fitted with Rotary compressor operating on Refrigerant R-32 suitable for wall mounting of reputed make such as Carrier/Toshiba/Diakin/Mitsubishi or equivalent make with 4.00 KVA voltage stablizer, MCB arrangement & installing OD units on terrace/as per site requirement including inlet and outlet copper tubes with proper insulation,drainage arrangement,cable link between ID unit and OD units,MS stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 4 Each Full Conversion INR
Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. 42 mtr Full Conversion INR
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. B) uPVC Pipe 6 Kgf/cm2 Full Conversion INR
40mm i/d 42 mtr Full Conversion INR
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm 42 mtr Full Conversion INR
Sub Work-2 Full Conversion INR
Sub Head -1 Estate Water Supply Full Conversion INR
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Full Conversion INR
Earth work upto 1.5 m. Depth All classes of soil except rocky 46.47 cum Full Conversion INR
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. uPVC Pipe 10 Kgf/cm2 Full Conversion INR
25mm i/d 99.97 mtr Full Conversion INR
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge. Full Conversion INR
CPVC SDR 11 pipes & fittings 40mm o/d 116.58 mtr Full Conversion INR
Providing, fixing and jointing ISI marked Non Return Valve of reputed make complete in all respect. Full Conversion INR
40mm i/d Brass Non Return Valve 4 nos Full Conversion INR
Providing, fixing and jointing Cpvc Union Couplings with Upvc Pipes complete in all respect. Full Conversion INR
25mm i/d Union 1 nos Full Conversion INR
40mm i/d Union 3 nos Full Conversion INR
Providing and installing water pump for pumping water Cap. 2.00 HP alongwith assembly, Electrical control panel including electrical connections complete in all respects. 1 Each Full Conversion INR
Providing & fixing 4.0mm Cable Water proof complete in all respect 75 mtr Full Conversion INR
Providing house hold connection laying, jointing, fixing, testing MDPE Pipes (as approved by Engineer-in-charge) including cost of excavation, CI bib cock as per IS : 210 with stainless steel spindle, 15mm i/d MDPE Pipe 2.00 mtr. 15mm i/d GI Pipe 2.50 mtr.(length on average basis) 3" o/d clamp, GM Ferrule ISI marked connection of 10 mm i/d ferrule medium specials such as tees, bends, sockets, elbows, nipples (100 mm & 150 mm) union couplings, GI hooks etc. MDPE Pipe lines laid in the ground or inside buildings, cutting, threading, making hole in wall and testing in trenches in the ground, all materials should be approved make (to the approval of Engineer-in-charge) Complete Job in all respects including cost of carriage.(Analysis Attached) 1 Each Full Conversion INR
Sub Head-2 Submersible Pump Full Conversion INR
Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. Full Conversion INR
Boring with 125mm id Housing Pipe Upto 150 mtr depth BGL 70 MTR Full Conversion INR
Supplying, assembling, lowering and fixing in vertical position in bore well PVC pipe of required dia, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in-charge. Full Conversion INR
110mm o/d pipe of 6 Kgf. / sqcm 56 Mtr Full Conversion INR
Supplying, assembling, lowering and fixing in vertical position in bore well PVC screen pipes including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. Full Conversion INR
110mm o/d pipe of 6 Kgf. / sqcm 10 Mtr Full Conversion INR
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. Full Conversion INR
100mm internal diameter 1 Each Full Conversion INR
Providing & Fixing of PVC Bail Plug complete 4 mtr Full Conversion INR
Providing and installing submersible motor 2.00 HP alongwith assembly, Electrical control panel including electrical connections complete in all respects. 1 Job Full Conversion INR
Submersible Cable 4.0mm Cable Water proof complete in all respect 90 mtr Full Conversion INR
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge. Full Conversion INR
CPVC SDR 11 pipe & fittings 32mm o/d 45 mtr Full Conversion INR
Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. 2 hrs Full Conversion INR
Supplying & fixing of M.S Clamp of size 100mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect 1 each Full Conversion INR
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. 2 each Full Conversion INR
Sub Work-3 Full Conversion INR
Estate Sewerage Full Conversion INR
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. Full Conversion INR
110 mm o/d pipes 75 mtr. Full Conversion INR
160mm o/d pipe 84 mtr. Full Conversion INR
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. Full Conversion INR
Depth not exceeding 3 m. BGL. All kinds of soil except rocky 79.6 cum Full Conversion INR
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 71.78 cum Full Conversion INR
Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. With F.P.S. bricks 1 1 soak pit Full Conversion INR
Costruction of Septic Tank Size 3.23 x 1.25x 1.80 mtr (Detail attached) 1 each Full Conversion INR
Costruction of Inlet Haudi Size 1.52 x x 0.91 x 1.83 mtr (Detail attached) 1 each Full Conversion INR
Sub Work-4 Full Conversion INR
Fire Fighting Arrangements as per NBC Code Note Full Conversion INR
Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 4 each Full Conversion INR
Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity 4 each Full Conversion INR
Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved make complete in all respect. 4 each Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_325812.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
SBD120.pdf
Tender Documents • 20.82 MB
BOQ_325812.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid