| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.6 LAccepted-AOC | ₹8.6 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹8.7 L+₹9,280.02 (1.08%)Rejected-AOC | ₹8.7 L+₹9,280.02 (1.08%) | L-2 | Rejected-AOC Being L -2 |
| 3 | L-3₹8.8 L+₹17,957.18 (2.09%)Rejected-AOC 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | ₹8.8 L+₹17,957.18 (2.09%) | L-3 | Rejected-AOC Being L-3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical As the firm failed to submit valid electrical registration certificate as Contractor with CPWD, MES, NBCC, BRO, Other Central Govt. Department, Concerned State PWD of Electrical Department in Composite/Electrical Category, hence Disqualified. |
| 5 | Rejected-Technical | - | - | Rejected-Technical As the firm failed to submit valid electrical registration certificate as Contractor with CPWD, MES, NBCC, BRO, Other Central Govt. Department, Concerned State PWD of Electrical Department in Composite/Electrical Category, hence Disqualified. |
Tender Value
₹8.9 L
EMD Value
₹17,742
Closing Date
7 Nov 2023, 12:00 pmClosed
Commandant (Engineer)
CONTRACT CELL, CENTRAL ZONE HQR, CRPF, H.C. BLOCK, SECTOR-III, SALT LAKE, KOLKATA (W.B.) PIN-700106
Repair and maintenance of faulty UG Cables, Borewell, 2 HP Submersible and Ceiling Fans
2023_CRPF_768451_3
B.V(205 CoBRA Bn.)/2023-24-CZ-C/Cell(NIT-79)
Open Tender
Electrical Works
Works
45 days
205 CoBRA Bn, At-Barwadih, Gaya (Bihar)
As pretender Enquiry
16 documents required · 16 mandatory
₹0
₹17,742
26 Dec 2023
2 Nov 2023
8 Nov 2023
2 Nov 2023
7 Nov 2023
2 Nov 2023
Amount
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia
Rocky strata including Boulders 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in borewell, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of150 mm dia:
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia
2 Inch PVC Column Pipe 10 ft per pics.
2 Hp Submersible pump
3 Core 2.5 sq mm Copper Wire
2 Hp Starter(with load safety relay)
Mild Steel Clamp 50mm.
50 mm GI Nipple(2inch)
50 mm GI flange
50 mm GI Coupling Socket.
50 mm GI Long Pipe bend
50 mm GI long Tee
10 mm Iron rope
1 Inch Pvc Pipe
Unskilled Labour
Semi-Skilled labour
Skilled Labour
Coil Rewinding and total repair of Ceiling fans by replacement of damaged parts and greasing fitted at various residential and non-residential structures.
Coil Rewinding and total repair of exhaust fans heavy duty by replacement of damaged parts and greasing fitted at various residential and non-residential structures.
Repairing of damaged street lights by replacement of new street lights (65 Watt)
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : 240 sq. mm
K.DAS AND CO.
DAS ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .